• 제목/요약/키워드: IT activity

검색결과 20,278건 처리시간 0.052초

화학분석(化學分析)을 통(通)한 수도(水稻)의 가리적량(加里適量) 추정(推定)에 관한 연구(硏究) (Studies on the Estimation of K2O Requirement for rice through the Chemical Test Data of Paddy Top Soil)

  • 김문규
    • 농업과학연구
    • /
    • 제2권1호
    • /
    • pp.61-100
    • /
    • 1975
  • 수도재배(水稻栽培)에 있어 작중토(作中土)의 유효규산함량(有效珪酸含量), ppm과 유기물함량(有機物含量)% 비(比) $SiO_2$/O.M. 근거(根據)한 N 적량(適量) 추정식(推定式) $Nkg/10a=(4.2+0.096\;SiO_2/O.M.).F$에서 N시비량(施肥量)을 추정(推定) 시용(施用)할 때의 적정(滴定) 가리(加里) 시용량(施用量) 추정식(推定式) $K_2Okg/10a=(K_O/\sqrt{Ca+Mg}-Ks/\sqrt{Ca+Mg})\sqrt{Ca+Mg}{\cdot}47{\cdot}BD$ 단 (但) $K_O/\sqrt{Ca+Mg}=0.03158+0.0007658\;SiO_2/O.M.$ $K_S/\sqrt{Ca+Mg}=Kme/100g/\sqrt{(Ca+Mg)}me/100g$의 타당성(妥當性) 여부(如否)를 판단(判斷)하기 위하여 3수준(水準)의 규회석처리(珪灰石處理)를 주구(主區)로하여 작토중(作土中)의 $SiO_2$/O.M. 비(比)를 증대(增大) 시키고 각주구별(各主區別)로 적정가리시용량(適正加里施用量) 추정식(推定式)에서 추정(推定)한 $K_2O$ 시용량(施用量)과 이에30%를 증비(增肥)하는구(區) 및 적정가리시용추정치(適正加里施用推定値)와는 관계(關係)없이 $K_2O\;8kg/10a$를 시용(施用)하는 3개수준(個水準)의 $K_2O$ 처리구(處理區)를 설정(設定)하여 수도품종(水稻品種) Akibare를 재배(栽培)하는 포장시험(圃場試驗)을 수행(遂行)하고 토양(土壤), 식물체분석(植物體分析) 및 수도(水稻)의 생육(生育)과 수량(收量) 및 수량구성요소(收量構成要素)들을 조사(調査)한 성적(成績)들을 종합검토(綜合檢討)한 결과(結果)를 요약(要約)하면 다음과 같다. 1. 작토중(作土中) 유효규산함량(有效珪酸含量) ppm과 유기물함량(有機物含量)%비(比), $SiO_2$/O.M.에 근거(根據)한 수도(水稻)에 대(對)한 N적량추정식(適量推定式)에서 추정(推定)한 N시용량(施用量)은 수도품종(水稻品種) Akibare의 생육(生育) 및 수량면(收量面)에서 볼 때 과량(過量)이었으며 토양(土壤) 및 식물체(植物體) 분석치(分析値)들에서 검토(檢討)한 결과(結果) $SiO_2$/O.M. 비조절(比調節)의 기본원리(基本原理)는 합당(合當)하나 그 식(式)의 상수(常數) 또는 F값은 변동(變動)되여야 한다고 판단(判斷)되였다. 2. 작토중(作土中)의 K활성도(活性度) 치환성(置換性) 염기 me/100 g비(比) $K/\sqrt{Ca+Mg}$를 조절(調節)하기 위한 $K_2O$ 시비량(施肥量) 추정식(推定式)에서 추정(推定)한 $K_2O$ 시용량(施用量)은 수도품종(水稻品種) Akibare의 생육(生育) 및 수량면(收量面)에서 과량(過量)이였으며 토양(土壤) 및 식물체(植物體) 분석치(分析値)들에서 검토(檢討)한 결과(結果) 조절기준(調節基準)되는 $K_O/\sqrt{Ca+Mg}$의 설정식(設定式) 즉(卽) $K_O/\sqrt{Ca+Mg}=0.03158+0.0007658\;SiO_2/O.M.$의 원리(原理)는 합리적(合理的)이나 기상수(其常數)의 변동(變動)이 필요(必要)하며 $K_S/\sqrt{Ca+Mg}$에 있어서도 토양(土壤)의 K공급능(供給能)을 고려(考慮)할수 있는 새로운 조절기준(調節基準)이 설정(設定)되어야 한다고 판단(判斷)되였다. 3. 수도(水滔)에 대한 $K_2O$ 시용량(施用量) 추정식중(推定式中)의 $K_S/\sqrt{Ca+Mg}$ 조절(調節) 기준(基準)은 K 공급능(供給能)을 대표(代表)할수 있는 작토중(作土中)의 치환성(置換性) Kme/100g에 근거(根據)해서 마음과 같이 설정(設定)함이 보다 합리적(合理的)임을 수도품종(水稻品種) Akibare의 천상수량 $K_2O$ 흡수량면(吸收量面)에서 밝힐수 있었다. 즉 $K_S/\sqrt{Ca+Mg}=0.037+0.78Kme/100g$.

  • PDF

성별에 따른 암환자의 통증 차이 (Gender Differences in Pain in Cancer Patients)

  • 김현숙;이소우;윤영호;유수정;허대석
    • Journal of Hospice and Palliative Care
    • /
    • 제4권1호
    • /
    • pp.14-25
    • /
    • 2001
  • 목적 : 통증에 있어서의 성별차이에 대한 연구결과에 있어서 일치하지 않고 있다. 이에 암환자를 대상으로 성별에 따른 통증정도를 살펴보고, 통증과 우울 및 활동도의 상호작용에 있어서도 성별에 따른 차이가 있는 지를 규명하기 위함이다. 방법 : 1999년 2월부터 6월까지 서울소재 S대학교 병원 혈액종양내과에 입원 또는 외래치료중인 암환자 140명(남성 78명, 여성 62명)을 대상으로 하였으며, 통증정도는 한국판 간이 통증 평가도구(BPI-K), 우울은 한국판 Beck Depression Inventory를 이용한 설문지를 통하여 수집되었고, 기타 인구학적 및 임상학적 자료는 의무기록 열람 및 주치의의 의견을 참조하여 수집되었다. 대상자를 서술하기위해 빈도, 평균, 표준편차를 구하였으며, 집단간 비교에서 불연속척도는chi-square test를 하였고, 연속척도는 t-test를 하였으며, 변인간 상관관계는 Pearson 상관계수를 구하였다. 결과 : 1) 통증의 중증도의 경우 통증정도가 24시간 동안 가장 심했을 때 통증 평균은 남성이 5.77점, 여성이 6.45점이었다. 통증으로 인한 지장정도는 남성의 경우 기분(5.49점), 인생을 즐김(5.36점), 통상적인 일(5.00점)이 순이었으나, 여성의 경우는 통상적인 일(7.48점), 인생을 즐김(7.16점), 기분6.53점) 순이었다. 2) 통증의 중증도의 경우 24시간 동안 평균 통증정도(t=-2.130, P=.035)에서 남성과 여성간에 유의한 차이가 나타났으며, 통증으로 인한 장애정도에서는 활동(t=-2.450, P=.015), 기분(t=-2,321, P=.022), 보행 능력(t=-2.762, P=.007), 통상적인 일(t=-4.946, P=.000), 대인관계(t=-2.595, P=.010), 수면(t=-2.071, P=.040), 인생을 즐김(t=-3.198, P=.001)에서 남성과 여성간에 통계적으로 유의한 차이가 나타났다. 3) 통증과 우울과의 상관관계 분석결과, 통증의 중증도에서 남성의 경우 24시간동안 가장 심했을 때 통증정도와 우울(r=0.323, P<.05), 평균 통증정도와 우울(r=.236, P<.05) 및 조사당시 바로 지금 느끼는 통증정도와 우울(r=0.248, P<.05)이 통계적으로 유의한 정적 상관관계가 나타난 반만 여성에서는 조사당시 바로 지금 느끼는 통증정도와 우울(r=.250, P<.05)만이 유의한 정적상관관계가 나타났다. 통증으로 인한 지장정도의 경우 남성은 모든 항목과 우울간 유의한 정적상관관계가 나타난 반만 여성에서는 전 항목과 우울간에 유의한 관계가 나타나지 않았다. 통증과 활동성 정도와의 상관관계 분석결과, 통증의 중증도에서 남성의 경우 24시간동안 가장 심했을 때 통증정도와 활동성 정도(r=0.378, P<.05), 평균 통증정도와 활동성 정도가(r=.330, P<.05)가 유의한 정적상관관계가 나타난 반면, 여성에서는 활동성 정도와 통증의 중증도는 유의한 관계가 없는 것으로 나타났다. 남성은 관계를 제외한 모든 항목의 통증으로 인한 지장정도와 활동성 정도가 유의한 정적상관관계가 나타난 반만 여성에서는 보행 능력, 통상적인 일, 인생을 즐김 항목과 활동성 정도간 유의한 정적 상관관계가 있었다. 결론 : 암환자의 통증정도 및 지장정도는 여성이 남성보다 높았으며, 통증과 우울 및 활동도와의 상관관계에서 차이를 보였다. 앞으로 암성통증 관리 대책 수립시 여성과 남성의 이러한 차이를 고려하여야 한다.

  • PDF

석재 서병오(1862-1936)의 1889년작 난죽석도 연구 (A Study on the 1889 'Nanjukseok' (Orchid, Bamboo and Rock) Paintings of Seo Byeong-o)

  • 최경현
    • 헤리티지:역사와 과학
    • /
    • 제51권4호
    • /
    • pp.4-23
    • /
    • 2018
  • 서병오(徐丙五, 1862-1936)는 서구적 '미술' 개념의 도입으로 일본화 내지 서양화로 기울던 일제강점기 시서화일치의 대구 문인화단이 형성되는데 중추적인 역할을 하였다. 그는 1879년 이하응(李昰應, 1820-1898)과의 만남을 계기로 서화계에 입문하였으나, 문인화가로 본격적인 활동을 시작한 것은 1910년 경술국치 이후부터이다. 그의 예술세계는 세 시기로 구분되며, 학습기인 1879년부터 1897년까지는 관직 진출을 목표로 하였던 때문인지 중국 화보를 임모하거나 이하응의 영향 아래 사군자화를 여가에 그리는 정도였다. 발전기는 1898년부터 1920년까지로 그는 애국계몽운동 등 사회적 지도자로 활동하다 1910년 경술국치 이후 삶의 방향을 문인화가로 전환하였다. 그리고 두 번째 중국 여행에서 다시 만난 민영익(閔泳翊, 1860-1914)의 운미란과 포화(蒲華, 1830-1911)의 묵죽법을 근간으로 새로운 화풍을 적극 모색함과 동시에 산수, 화훼, 기명절지 등의 화목도 다루었다. 완숙기인 1921년부터 1936년까지는 대구와 한양을 오가며 근대 한국 화단의 서화가로 왕성하게 활동하였으며, 묵란과 묵죽에서 윤묵의 호방한 필법을 특징으로 하는 개성적 화풍을 완성하였다. 특히 학습기의 경우 관련 기록이나 현전작품이 드물어 서병오의 창작활동이나 화풍 등에 관한 것은 추론의 수준을 벗어나지 못하고 있다. 이와 관련해 본고에서 집중적으로 분석한 서병오의 1889년작 난석죽도 11점은 학습기의 화풍 연원이나 수준을 가늠할 수 있는 중요한 단서라는 점에서 주목된다. 1889년작 난죽석도 가운데 묵란도는, 이하응이 1882년 7월 청군에 의해 체포되기 이전에 그린 초기 군란도와 석란도에서 영향 받았다는 사실을 확인하였다. 묵죽도는 한양에 널리 알려진 양주화파 정섭(鄭燮, 1693-1765)과 김정희의 제자 허련(許鍊, 1809-1892)의 화법을 수용했을 뿐만 아니라 이하응의 석란도 형식을 응용하여 변화를 시도했던 것으로 보인다. 괴석도의 경우 직접적인 관련성은 찾지 못하였으나, 19세기 후반 청나라의 괴석화가 주당(周棠, 1806-1876)과 여항화가 정학교(丁學敎, 1832-1914) 등에게 영향을 받았던 것으로 판단된다. 결론적으로 서병오의 1889년작 난죽석도는 학습기에 그려진 것으로 운현궁을 찾았던 허련과 정학교 같은 동시기 화가들이나, 한양에 작품이 유입되었던 정섭과 주당 등의 중국 작품을 실견하며 이들의 화풍을 수용하였다는 사실을 알려준다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

잉어 Cyprinus carpio의 먹이 섭취량과 성장에 미치는 용존산소량의 영향 (Influence of Oxygen Concentration on the Food Consumption and Growth of Common Carp, Cyprinus carpio L.)

  • 자파사이파바디;김인배
    • 한국양식학회지
    • /
    • 제2권2호
    • /
    • pp.53-90
    • /
    • 1989
  • 식욕에 부합되는 적정양의 먹이 섭취는 잉어의 성장을 증가시키고, 동시에 먹이의 허비를 막으며, 그로 인해서 사육수질의 오염을 막는 부수적인 효과도 가지게 된다. 이 목적을 달성하기 위하여 식욕 유발과 그에 따른 빠른 성장의 중요한 요인으로서 용존산소에 관한 정밀한 연구가 필요하다. 수온 $25^{\circ}C$ 하에서 잉어(이스라엘계)의 미성어, 67g, 200g, 400g, 600g 및 800g 되는 실험군으로서, 용존산소를 2.0-6mg/$\iota$ 사이에서 사료를 체중의 $1\%$부터 먹을 수 있는 양까지에 걸쳐서 사육실험연구를 하였다. 어체가 작을수록 동일한 용존산소 조건에서는 보다 높은 식욕과 보다 많은 먹이 섭취량을 나타내었다. 어체가 클수록 낮은 용존산소양에서는 생활 능력이 약해지고, 먹이 섭취량이 증가하면 내성은 더욱 줄어졌다. 성장률(일간 성장률)은 낮은 용존산소에 의해서 영향을 받지 않는 한, 먹이의 섭취량이 많을수록 증가하였다. 최고성장률은 67 g 어에서는 D.O. 5.0 mg/$\iota$에서 1일 먹이 량이 체중의 $7\%$ 일때 일간성장률 $\5.05%$였고, 200g 어에서는 D.O. 5.5/$\iota$ 에서 먹이량 $6\%$일때 1일 성장률이 $3.75\%$였다. 400g 어에서는 D.O. 6.0 mg/$\iota$에서 먹이량이 $5\%$ 일때 1일 성장률 $3.37\%$ 였으며, 600g 어에서는 D.O. 5.5 mg/$\iota$에서 먹이량이 1일 $4\%$였을 때 1일 성장률 $2.82\%$였다. 800g 어에서는 D.O. 5.0mg/$\iota$에서 먹이량이 1일 $3\%$었을 때 1일 성장율이 $1.95\%$였다. 정상적인 생활 및 성장 기능발휘 가능 D.O. 농도로부터 최고 먹이 섭취가능양에 부합되는 D.O. 농도까지 사이에서 먹이 전환효율(사료가 어체로 바뀌는 효율)은 처음 D.O.가 증가함에 따라 높아지고, 최고치에 이른 뒤, D.O.가 더욱 더 높아짐 에 따라 먹이 전환효율은 다시 감소하기 시작한다. 이 최고 사료효율은 작은 어체에서는 큰 어체 보다 높은 먹이 섭취량에서 나타난다 (물론 먹이 섭취량에 부응하는 D.O.량이 갖춰졌을때). 즉 최고 먹이 전환효율은 67g 어에서 D.O. 3.0-4.0 mg/$\iota$에서 먹이 섭취량 $4\%$때 였으며, 200g 어에서는 D.O. 3.0-4.5mg/$\iota$에서 먹이 섭취량 $3\%$때였고, 400 g 어에서는 D.O. 4.0-4.5mg/$\iota$에서 먹이 섭취량 $2\%$때였다. 600g 및 800 g 어에서는 가장 낮은 D.O.에서 먹이 섭취량 $1\%$ 때였다. 적절하지 못한 낮은 D.O. 함량에서는 정상적인 조건하의 개체보다 먹이 섭취량이 감소하며, 또 먹이가 소화관을 빨리 통과하고, 똥의 양이 증가하는 것을 관찰할 수 있었다. 그리고, 견디지 못할 만큼 낮은 D.O.하에서는 먹이를 토하고, 체색이 옅은 황색으로 변하거나, 또는 회색의 얼국진 반점으로 변하기도 했다. 이 모든 현상들이 먹이 전환효율의 감소로 이어졌다. 반면에 아주 높은 D.O.하에서는 강한 활동을 하였으며, 어체 크기가 같고 먹이의 양도 같았지만 D.O.가 약간 낮은 상에 비교하여 먹이 전환효율이 떨어지는 경향이 나타났다. 모든 크기에서 먹이량을 체중의 $1\%$만 주었을 때는 D.O. 량이 2.0-2.5mg/$\iota$ 이면 적절하였다. 먹이량을 증가시키면 어체의 정상활동을 유지시키기 위하여 보다 높은 D.O.가 필요하였다. 67g 어에서는 D.O. 2.0-2.5mg/$\iota$이면 체중의 $2\%$이상 먹이량을 충분히 지탱할 수 있었으나, 먹이를 $5\%$로 증가시키면 D.O. 3.0-4.0 mg/$\iota$일 때 식욕이 보다 왕성하고 높은 성장을 가져 왔다. 먹이량이 $5-7\%$에서는 4.0 mg/$\iota$ 이상의 D.O.라야 식욕을 유지시킬수 있다. 200g 어에서는 먹이량이 체중의 $2-3\%$ 일때는 D.O. 3.5-4.5mg/$\iota$에서 가장 높은 성장률을 보였으나 먹이량이 체중의 $3-6\%$로 올라가면 D.O. 함량이 4.5mg/$\iota$을 넘어서야만 어류의 생활기능 발휘에 부응될 수 있었다. 400 g, 600 g 및 800 g 어에서는 먹이량이 체중의 $2\%$를 넘을 때는 ($4\%$$5\%$까지 실험) 모두 D.O. 함량이 4.5 mg/$\iota$를 넘어야 했다.

  • PDF

수도저위생산력(水稻低位生産力)의 원인구명(原因究明)에 관(關)한 영양생리적연구(營養生理的硏究) (Studies on Nutrio-physiology of Low Productive Rice Plants)

  • 박준규
    • Applied Biological Chemistry
    • /
    • 제17권1호
    • /
    • pp.1-30
    • /
    • 1974
  • 수도저위(水稻低位) 생산력(生産力)의 원인구명(原因究明)에 관(關)한 영양생리학적연구(營養生理적硏究)로 여러 가지 생육조건하(生育條件下)에서 품종별(品種別) 양분흡수(養分吸收) 및 동화기능(同化機能)과 양분(養分)의 체내(體內)에서의 이행양상(移行樣相)을 추구(追究)하는 한편 고수량지(高收量地) 벼와 저수량지(低收量地) 벼에 대(對)한 생육시기별(生育時期別)로 양분(養分)의 흡수(吸收) 체내무기양분(體內無機養分)과 수량(收量) 및 수량구성요소(收量構成要素)와의 관계(關係) 등(等)을 추구(追究)하여 저수량지(低收量地) 벼의 영양생리적(營養生理的) 저수요인(低收要因)을 밝히고저 본연구(本硏究)를 수행(遂行)하였던 바 그 결과(結果)를 요약(要約)하면 다음과같다. 1. 양분(養分)의 흡수력(吸收力)은 품종(品種)에 따라 차이(差異)가 있으며 인산(燐酸) 및 가리(加里)의 흡수력(吸收力)이 강(强)한 품종(品種)은 구사부에, 진흥(振興)이며 낮은 품종(品種)은 팔달(八達)이었다. 2. 근(根)의 ${\alpha}-naphthylamine$의 산화력(酸化力)과 인산(燐酸)의 흡수력(吸收力)과는 유의적(有意的)인 상관관계(相關關係)가 있으며 산화력(酸化力)이 높으면 인산(燐酸)의 흡수(吸收)가 증대(增大)되었바. 3, 탄소동화력( 炭素同化力)은 품종(品種)에 따라 차이(差異)가 있으며 노인도(老人稻), 구대내조욱(九大耐潮組) 3호(號), 수원(水原)82호(號), 진흥(振興) 등은 강(强)하고 대구조(大脚租), 관옥(關玉), 육우(陸羽) 132호(號)가 약(弱)하였다. 4, 질소(窒素)의 증시(增施)는 소비(少肥)에 비(比)하여 동화량(同化量)은 증가(增加) 되나 등화산물(同化産物)의 이삭으로의 이전(移轉)은 적었다5. 정상(正常) 생육(生育)한 벼에 비(比)하여 인산(燐酸), 가리(加里) 및 마그네슘이 결핍(缺達)된 벼는 전탄소동화량이(全炭素同化量)이 정상(正常) 벼 100에 비(比)하여 40이하(以下)로 현저(顯著)히 낮으며 그 순서(順序)는 Mg>P>K이고, 동화물(同化物)의 이전(移轉)에 장해(障害)가 큰 것은 K>Mg>P의 순(順)이었다. 6. 고수량지(高收量地) 벼는 저수량지(低收量地) 벼에 비(比)하여 총건물(總乾物) 생산량(生産量)이 현저(顯著)하게 많고 특(特)히 유수형성기(幼穗形成期) 이후(以後)에 증가량(增加量)이 더욱 현저(顯著)하였다. 7. 고수량지(高收量地) 벼는 출수기(出穗期)에 옆면적(葉面積)이 최고(最高)에 달(達)하였다가 그 이후(以後) 완만(緩慢)하게 줄어지나 저수량지(低收量地) 벼는 출수이전(出穗以前)에 엽면적(葉面積)이 최고(最高)에 달(達)하였다가 출수이후(出穗以後)에 급격(急激)히 감소(減少)되며 그 원인(原因)은 하엽(下葉)의 조기고사(早期枯死)에 기인(起因)되었다. 8. 고수량지(高收量地) 벼는 저수량지(低收量地) 벼에 비(比)하여 생육초기(生育初期)에는 투과광율(透過光率)이 높고 생육후기(生育後期)에 낮았으나 투과광율대(透過光率對) 엽면적비(葉面積比)는 고수량지(高收量地) 벼에서 높았다. 9. 순동화량(純同化量)은 저수량지(低收量地) 벼에 비(比)하여 고수량지(高收量地)벼에서 많았으며 이는 또한 엽면적(葉面積)이 증가(增加)됨에 따라 감소(減少)되었다. .10. 고수량지(高收量地) 벼는 저수량지(低收量地) 벼에 비(比)하여 유수형성기(幼穗形成期) 이후(以後) 체내질소(體內窒素), 가리(加里) 및 규산(珪酸)의 함유율(含有率)이 높으면서 $K_2O/N$, $SiO_2/N$ 비(比)가 높았다.11. 저수량지(低收量地) 벼는 고수량지(高收量地) 벼에 비(比)하여 출수기(出穗期)에 보유(保有)된 질소(窒素), 인산(燐酸), 가리(加里) 및 마그네슘등이 출수이후(出穗以後) 이삭으로의 이행율(移行率)이 높았다. 이는 저수량지(低收量地) 벼가 생육후기(生育後期)에 양분(養分)의 흡술량(吸收量)이 부족(不足)하여 체내(體內) 저장양분(貯藏養分)이 재이동(再移動)되기 때문이며 따라서 하엽(下葉)은 양분부족(養分不足)으로 조길고사(早期桔死)가 많아지는 것으로추정(推定)되었다. 12. 고수량지(高收量地) 벼는 질소흡수(窒素吸收)가 전생육기간(全生育期間)을 통(通)하여 완만(緩慢)하며 출수이후(出穗以後)에도 흡수량(吸收量)이 많으나 저수량지(低收量總) 벼는 출수이전(出穗以前)에 많고 출수이후(出濾以後)는 거의 흡수(吸收)되지 않았다. 13. 출수기(出穗期)의 체내(體內) 질소(窒素), 가리(加里) 함유율(含有率)과 수량(收豊)과는 현저(顯著)한 정(正)의 상관(相關)이 성립(成立)되였으며 수확기(收獲期)의 가리(加里), 규산함유율(珪酸含有率) 그리고 $K_2O/N$, $SiO_2/N$과 수량(收量)과도 현저(顯著)한 정(正)의 상관관계(相關關係)가 성립(成立)되었다. 14. 출수기(出穗期)에 보유(保有)된 전분(澱粉)이 이삭으로의 이전(移轉)은 고수량지(高收量地) 벼가 약(約) 10%인데 반(反)하여 저수량지(低收量地) 벼는 약(約) 40%로 많았다. 따라서 저수량지(高收量地) 벼는 출수(出穗) 이후(以後) 동화의존도(同化依存度)가 높았다. 15. 고수량지(高收量地) 벼는 저수량지(低收量地) 벼에 비(比)하여 질소(窒素), 인산(燐酸), 가리(加里), 규산(珪酸) 및 망간의 흡수량(吸收量)이 현저(顯著)하게 많았고 생육시기별(生育時期別) 흡수량(吸收量)의 차이(差異)는 유수형성기(幼穗形成期) 전후(前後)에 현저(顯著)하였다. 16. 수확기(收穫期)의 질소(窒素), 인산(燐酸), 가리(加里), 석탄(石炭), 마그네슘, 규산(珪酸) 및 망간의 총흡수량(總吸收量)과 수량(收量)과는 고도(高度)의 정(正)의 상관관계(相關關係)가 인정(認定)되었다. 17. 수확기(收穫期)에 질소(窒素), 인산(燐酸), 가리(加里), 석탄(石炭), 마그네슘 및 규산(珪酸)의 흡수량(吸收量)과 수당입수간(穗當粒熱間)에, 질소(窒素) 및 가리(加里)의 흡수량(吸收量)과 수수(穗數)와는 유의적(有意的)인 정(正)의 상관관계(相關關係)가 성립(成立)되었다.

  • PDF

산사태발생지(山沙汰發生地)와 피해위험지(被害危險地)의 환경학적(環境學的) 해석(解析)과 예방대책(豫防對策) -평창지구(平昌地區)를 중심(中心)으로- (Environmental Interpretation on soil mass movement spot and disaster dangerous site for precautionary measures -in Peong Chang Area-)

  • 마상규
    • 한국산림과학회지
    • /
    • 제45권1호
    • /
    • pp.11-25
    • /
    • 1979
  • 1979년(年) 8월(月) 4일(日)과 5일(日)에 걸쳐 강원도 평창지구에 많은 사태(沙汰)가 발생된 바 있었다. 이 지역(地域)을 답사할 기회를 통해 산사태에 대한 조사연구(調査硏究)가 부족(不足)하고 예방대책(豫防對策)이 미약하다는 사실을 알게 되었다. 이에 현지답사시(現地踏査時) 얻었던 자료(資料)와 기 연구자들의 보고서 등을 참조로 하여 우리나라 산사태(山沙汰)의 발생조직과예방대책을 살펴본 결과는 다음과 같았다. 1. 지난 6년간(年間)의 자료(資料)로 1일(日)200mm이상(以上), 1시간당(時間當) 60mm이상(以上)의 호우지대(豪雨地帶)를 보면 횡성, 원주, 영동, 무주, 남원과 순천을 연결하는 서부지역과 경상남도의 남부해안지방(南部海岸地方)에 분포(分布)되 있다. 이 원인(原因)은 산맥(山脈)과 저기압(低氣壓)의 방향(方向)에 영향을 받은 것으로 사료(思料)된다. 2, 호우(豪雨)의 정점(頂點)의 분포(分布)는 야간에 나타나며 이 시점에서 산사태(山沙汰)를 일으키고 막대한 피해(被害)를 주는 것 같다. 3. 평창지역(平昌地域)의 산사태(山沙汰)는 화강암(花崗巖)의 조사질양토(粗砂質壤土)와 석회암(石灰巖) 정암(貞岩)의 점토질토양(粘土質土壤)에서 발생(發生)하며 토석류(土石流)는 기암면(基岩面)이나 석회암토양(石灰巖土壤)에서 나타나는 반시(盤尸)을 따라 일어나고 있었다. 4. 이들 암석(岩石)에서 유래한 토양(土壤)의 투수력(透水力)은 빠른 것 같으며 화강암토양(花崗巖土壤)은 토성(土性)의 영향으로 석회암토양(石灰岩土壤)은 토양구조(土壤構造), 폐식(廢植)의 높은 함량(含量)과 근계(根系)의 영향 때문이다. 5. 산사태발생(山沙汰發生)의 근원지의 지형(地形)은 대부분 곡두(谷頭)의 요형지(凹型地)와 산복 상부의 요형(凹型)지에서 나타나고 있다. 이는 유거수(流去水)의 집수력(集水力)때문인것 같고 이 지점의 토양단면(土壤斷面)을 보면 석회암지대(石灰岩地帶)는 혼연성토양(混淵性土壤), 화강암지대(花崗岩地帶)는 발(髮)한 심토호(深土戶)으로 되있다. 6. 산사태지(山沙汰地)의 경사도(傾斜度)는 대부분 $25^{\circ}$이상(以上)에서 나타났고 경사위치(傾斜位置)는 산복상부의 6~9부 능선에서 나타났다. 7. 산사태지(山沙汰地)의 식피(植被)는 대부분 화전(火田)경작지, 화전초지(火田草地), 화전조림지(火田造林地), 황폐지(荒廢地)의 불량임분(不良林分)과 미림목지(未林木地)이었다. 일부 성림지(成林地)(중경목지)에도 나타났으나 대개 표상(表上)에 암석시(岩石尸)이 있는 지역이다. 8. 산사태위험도(山沙汰危險度)는 몇가지 환경인자(環境因子)로 즉 식피(植被), 경사도(傾斜度), 경사형태(傾斜形態) 및 위치(位置), 기암(基岩)과 분포형태(分布形態), 토양단면(土壤斷面)의 특성(特性) 등(等)으로 추정이 가능할 것 같다. 9. 가옥피해(家屋被害)는 대부분 다음과 같은 지형(地形)에서 나타나고 있다. 충적추(沖積錐)와 선상지요형사면(扇狀地凹型斜面)의 산록, 곡간(谷間)이나 야계변(野溪邊)의 소단구(小段丘)와 붕적토지(崩積土地) 등(等)이다. 가옥피해위험지(家屋被害危險地)는 항공사진으로 가옥(家屋)주위의 지형상태(地形狀態)를 참고를 하면 판정(判定)이 가능할 것 같다. 10. 산사태(山沙汰)의 예방대책(豫防對策)으로 위험지(危險地)의 진단기술(診斷技術)의 개발(開發), 현지조사(現地調査)를 통해 가능한 조속(早速)히 예방사방(豫防砂防)이 이루어져야 할 것이다. 가옥(家屋)과 부락(部落)의 피해예방대책(被害豫防對策)이 수립(樹立) 실행(實行)하여야 되며 재해방비림(災害防備林)의 조성책(造成策)이 고려되어야 할 것이다. 11. 산사태(山沙汰)에 의한 가옥(家屋)과 부락(部落)의 피해위험도(被害危險度)를 판정(判定)하여 지도사업(指導事業)을 통해 알려 주어야 한다. 12. 사태위험지(沙汰危險地)의 계벌작업(階伐作業), 화전경작(火田耕作), 연료채취(燃料採取)를 철저히 금지(禁止)시키고 피해위험지(被害危險地)의 가옥(家屋)신축을 규제시켜야 될 것이다. 따라서 산림경영계획(山林經營計劃)의 편성시 산사태(山沙汰)여부 토양침식(土壤浸蝕)과 홍수문제(洪水問題)들이 고려되어야 하며 재해예방대책(災害豫防對策)이 포함되어야 할 것이다.

  • PDF

성조숙증 여아들의 임상적 특징 및 진단별 성선자극호르몬 분비호르몬 GnRH (Gonado Tropin Releasing Hormone) 검사결과의 비교분석평가 (Clinical Characteristics of precocious puberty girls and Comparison Analysis of GnRH Test results with Diagnosis type)

  • 김정인;권원현;문기춘;이인원
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.54-61
    • /
    • 2016
  • 1. 목적 성조숙증은 2차성징의 발달이 여아에서는 8세 이전 남아에선 9세 이전에 조기 2차성징이 출현하는 증상으로 골단의 조기 폐쇄를 일으켜 결국 최종 성인 신장의 감소를 가져오는 질환이다. 본 연구는 성조숙증으로 내원한 여아들의 GnRH(Gonado-tropin-releasing Hormone) 자극검사 결과와 의무기록을 후향 분석하여 진단별 차이를 알아보고자 하였다. 2. 방법 2015년 2월부터 2015년 12월까지 분당서울대병원 소아청소년 내분비내과를 내원한 여아 118명을 대상으로 하였다. 의무기록을 후향 분석하여 대상 환아들은 진성 성조숙증(true precocious puberty) 57명, 조기사춘기(early puberty) 39명, 유방 조기발육군(premature thelarche) 22명을 진단별로 분류하였다. 진단 당시의 신장, 체중, Tanner stage, 골연령, 역연령, 부모의 키, GnRH 검사에서 LH, FSH와 E2 (Estradiol) Basal 값도 함께 조사하였다. 성선 자극호르몬 결과값 LH (Basal,30min,45min,60min) FSH(Basal,30min,60min)을 비교하여 각 그룹별 LH, FSH Peak치 분포도와 LH 최고치/LH 기저치 비율에 대한 평균${\pm}$표준편차와 LH 최고치/FSH 최고치 비율에 대한 평균${\pm}$표준편차를 비교하여 각 3그룹 간 유의확률(P-value) 값을 구하였다. 골연령의 측정은 Greulich-Pyle법(왼쪽 수근골 X선 사진을 촬영하여 골성숙도를 평가하는 방법- 6개월 단위의 표준손목사진을 보고 비교해서 골연령을 유추하는 방식)을 이용한 소아 청소년 내분비내과 교수가 직접 판독한 결과로 사용하였고 GnRH 검사는 합성 LHRH 100 ug을 정맥 주사하여 LH는 Basal, 30분, 45분,60분 후에 채혈된 결과값과 FSH는 Basal, 30분, 60분후에 채혈된 결과값을 조사하였다. 3. 결과 진성성조숙증그룹의 평균 키는$131{\pm}14.85$, 평균체중은 $8.80{\pm}4.93$, 평균역연령은 $7.1{\pm}0.81$, 평균 골연령은 $9.9{\pm}0.9$, 조기사춘기 그룹의 평균키는 $134{\pm}5.10$, 평균체중은 $28.50{\pm}4.43$, 평균역연령은 $8.05{\pm}0.03$, 평균 골연령은 $10.0{\pm}0.62$, 유방조기발육군의 평균 키는 $129{\pm}6,01$ 평균체중은 $28.65{\pm}5.98$, 평균역연령은 $7.02{\pm}0.58$ 평균 골연령은 $8.04{\pm}1.29$로 세 그룹간에 키와 체중 비교 시 유의한 차이가 없었고 역연령(P < 0.0001), 골연령( P< 0.0001), 골연령과 역연령과의 차이(P < 0.0002 )에서는 그룹간 유의한 차이가 있었다. 각 그룹별 LH, FSH Peak치 분포도 비교시 진성성조숙증 그룹은 LH 30분-82.5%, 45분-12.3%, 60분-5.3%, FSH 30분-8.8%, 60분-91.2%로 높은 Peak치를 보였고 조기사춘기 그룹은 LH 30분-79.5%, 45분-17.9%, 60분-2.6%, FSH 30분-7.7%, 60분 -92.32%로 높은 Peak치를 나타내었다. 유방조기 발육군 그룹에서는 LH 30분-30%, 45분-59%, 60분-9.09%, FSH 30분 -0%, 60분-100%로 Peak치를 나타내었다. LH Peak/LH basal ratio 비교시 진성성조숙증 그룹은 $19.09{\pm}17.15$, 조기사춘기 그룹은 $15.23{\pm}10.88$ 유방조기 발육군 그룹은 $4.93{\pm}4.36$으로 3 그룹간 유의한 차이를 보였다(P < 0.0001). LH Peak/FSH Peak ratio 비교시 진성성조숙증 그룹은 $1.222{\pm}0.77$, 조기사춘기 그룹은 $1.34{\pm}1.23$ 유방조기 발육군 그룹은 $0.3{\pm}0.09$로 3 그룹간 유의한 차이(P < 0.0001)를 보였다. 4. 결론 여아들의 진성성조숙증을 진단하기 위한 GnRH Test 검사는 자극 후 30분과 60분 사이에 LH 최고치가 기저치에 비해 2~3배 이상 증가 되어 있거나 또는 5~10 IU/L 이상 증가되었을 때 유용한 판정 자료로 이용 될 수 있는 핵의학 연속검사라고 사료되어진다.

  • PDF

옥정호의 육수생물학적 연구 (Limno-Biological Investigation of Lake Ok-Jeong)

  • 송형호
    • 한국수산과학회지
    • /
    • 제15권1호
    • /
    • pp.1-25
    • /
    • 1982
  • 우리나라 남서부에 위치한 대표적 인공호인 옥정호에서 1980년 5월부터 1981년 8월까지 16개월 동안 매월 호소의 이화학적 요인들과 동식물 Plankton의 계절적 변동과 수직적 변동, 그리고 어류상 등을 조사하여 종합적인 육수생물학식 연구를 시행하였다. 표층수의 수온은 8월에 최고 $28.2^{\circ}C$, 1월과 2월에 최저 $3.5^{\circ}C$였다. 저층인 수신 40m 깊이의 수온은 9월이 최고 $8.5^{\circ}C$, 2월에 최저 $3.5^{\circ}C$로서 그 차이는 $5^{\circ}C$였다. 수온 만화에 따른 수온 탁층의 분포 및 수직 안정도를 보면 11월부터 3월까지 저수온기에는 완전 수직혼합이 일어나며 2월에는 표층에서 저층까지 모두 $3.5^{\circ}C$였다. 4월부터 6월까지 표층수 수온의 상승으로 인하여 표층부터 l0m 수신의 층까지에 걸쳐 양층이 형성되며, l0m 이하의 저층수는 $5.6\sim7.1^{\circ}C$의 범위로 성층이 생겼다. 고수온의 표층은 점점 깊어져 $7\sim10$월에는 $15\sim25m$ 수신에 수온탁층이 형성되어 수직 혼합이 일어나는 표층과 안정된 저층으로 구분되었다. 8월의 표층수는 $28.2^{\circ}C$, 저층수온도 상당히 상승되어 9월에는 $8.5^{\circ}C$까지 상승하여 호수의 혼합이 의외로 큰 것을 알 수 있었다. pH의 년중변화는 표층에서 6.8(1월)$\sim$9.0(8월)의 범위이며, 중층에서는 $6.5\sim7.0$, 저층에서는 $6.0\sim7.5$ 였다. DO는 년중 보화상태였고, 저수온기인 겨울철에는 약간 과보화 상태였으며, 년중 각 DO의 약층은 나타나지 않아, 저층까지 DO양은 비교적 높았다. 투명도는 최고가 2월에 4.6m 였고, 최저가 8월에 1.7m 였으며 1980년 8월의 예비조사시에도 8월에 0.9m로 조사기간중 최하였다. 이렇게 낮은 투명도는 이 때 최대로 번모한 Anabaena spiroides, Melosira granulata 등 때문인 것으로 생각된다. 염소양, 지산태 지소, COD, 인산염의 분석결과는 1980년의 값에 비하여 1931년의 값이 다소 증가된 경향을 보인다. 또 칼슘, Mg, Fe와 같은 무기물질들의 분석결과로 보아 옥정호의 수질은 연수로 평가되었고 크룸이나 수은과 같은 중금속물질들도 극히 미양 검출되었다. 조사기관신 본 호에서 채집된 Plankton의 출현종은 모두 7과 72속 107종이었다. 그 중 Phytoplankton은 Cyanophyta가 12종, Bacillariophyta 19종, Chlorophyta 23종이었고, Zooplankton은 Protozoa14종, Rotifera 29종, Cladocera 4종, Copepoda 6종이었다. Phytoplankton의 생산은 $7\sim10$월의 대번식(Peak는 10월 $1,504\times10^3\;cells/l$)과 $1\sim4$월의 소번식(Peak2월 $236\times10^3\;cells/l$)의 2회의 Peak를 나타냈다. Phytoplankton의 종 조성 만화의 양상을 보면 Melosira granulata, Anabaena spiroides와 같이 고수온기인 $7\sim10$월에 번무하는 무리, Asterionella gracillima, Synedra acus, S. ulna와 같이 저수온기에 다양 출현하여 겨울철에 번무하는 무리, 그리고 Microcystis aeruginosa, Ankistrodesmus falcatus와 같이 소양씩 주년 출현하는 세 무리로 대별할 수 있다. Zooplankton의 종 조성 및 출현 양상을 보면 주요 종들은 Thermocyclops taihokuensis, Difflugia corona, Bosmina longirostris, Bosminopsis deitersi, Keratella quadrata, Asplanchna priodonta, A. herricki 등이며, 이들은 $10\sim11$월부터 익년 2월 혹은 4월까지의 저수온기에 출현이 없거나 있어도 매우 적었다. 수직 일견변동은 주로 Microcystis aeruginosa, M. incerta, Anabaena spiroides, Melosira granulata, Bosmina longirstris에 의하여 나타났다. 특히 M. granulata는 일몰과 더불어 저층으로 밀집하는 이동을 했으며 B. longirostris는 일몰과 더불어 표층으로 부상하고 일출과 더불어 전 수층에 확산되는 양상을 보였다. 본 호에서 채집된 어류는 10과 31속 41종이었다. 그 중 Pseudoperilampus uyekii와 Coreoleuciscus splendidus를 포함한 13종의 어류는 한국 특산종으로 우리나라의 다른 호소들에 비하여 어류상이 다양하였다.

  • PDF