• Title/Summary/Keyword: IT Routine

Search Result 1,049, Processing Time 0.036 seconds

Usefullness of CT Gastrography and Vurtual Gastroscopy using Computed Tomography in Detection of Gastric Cancer (위암 진단에 있어서의 CT 위장 조영술과 상부위장관 조영술과의 비교)

  • Baik Yong Hae;Lee Soon Jin;Lee Ji Yun;Noh Jae Hyung;Sohn Tae Sung;Kim Sung;Kim Yong Il
    • Journal of Gastric Cancer
    • /
    • v.3 no.4
    • /
    • pp.195-200
    • /
    • 2003
  • Purpose: Advancement of computed tomography (CT) hardware and software has allowed thin section scanning and reconstruction of fascinating 2-dimentional (2D) and 3- dimentional (3D) images. Especially, the reconstruction of 3D images of gastrointestinal tract has been used in the detection and diagnosis of pre-malignant and malignant diseases. To compare the efficacy of CT gastrography with conventional upper gastrointenstinal series (UGIs) in gastric cancer patients. Materials and Methods: During Nov. 2002 and Mar. 2003, twenty-seven patients who had gastric cancer received both double contrast upper GI series and CT gastrography prior to radical surgery. Among these patients, nineteen had early gastric cancer (EGC) and 8 had advanced gastric cancer (AGC). Fifteen patients were male and 12 were female. The mean age was 54 yrs (range, $27\∼75$ yrs). The patients were placed on NPO and Stomach was distended with gas in fasting state prior to CT scanning. Double contrast upper GI series were performed as routine manual. CT scan was conducted in all patients using 8 or 16-channel multidetector CT in this study. The collimation and reconstruction for CT scanning were set at 2.5 mm and 1.25 mm, respectively. CT scanning was performed in the supine position. For image processing, CT gastrography, in which raysum and surface rendering images were constructed, virtual and 2D image in coronal and sagittal images were performed. The detectability of gastric cancer was assessed between UGIs and CT gastrography. Results: In AGCs, the detection rate of cancer using CT gastrography and virtual gastroscopy was higher than EGC cases. However, CT gastrography and virtual gastroscopy showed less favorable results than UGIs. Even though only a small number of cases had been studied, we might conclude that CT gastrography and virtual gastroscopy could replace UGIs in the detection of AGC cases. Conclusion: The detection rate used with CT gastrography and Virtual gastroscopy is not better than that of UGIs in early gastric cancer, however, in advanced gastric cancer cases, it is nearly equal to that of UGIs.

  • PDF

Genetic Parameters of Milk β-Hydroxybutyric Acid and Acetone and Their Genetic Association with Milk Production Traits of Holstein Cattle

  • Lee, SeokHyun;Cho, KwangHyun;Park, MiNa;Choi, TaeJung;Kim, SiDong;Do, ChangHee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.11
    • /
    • pp.1530-1540
    • /
    • 2016
  • This study was conducted to estimate the genetic parameters of ${\beta}$-hydroxybutyrate (BHBA) and acetone concentration in milk by Fourier transform infrared spectroscopy along with test-day milk production traits including fat %, protein % and milk yield based on monthly samples of milk obtained as part of a routine milk recording program in Korea. Additionally, the feasibility of using such data in the official dairy cattle breeding system for selection of cows with low susceptibility of ketosis was evaluated. A total of 57,190 monthly test-day records for parities 1, 2, and 3 of 7,895 cows with pedigree information were collected from April 2012 to August 2014 from herds enrolled in the Korea Animal Improvement Association. Multi-trait random regression models were separately applied to estimate genetic parameters of test-day records for each parity. The model included fixed herd test-day effects, calving age and season effects, and random regressions for additive genetic and permanent environmental effects. Abundance of variation of acetone may provide a more sensitive indication of ketosis than many zero observations in concentration of milk BHBA. Heritabilities of milk BHBA levels ranged from 0.04 to 0.17 with a mean of 0.09 for the interval between 4 and 305 days in milk during three lactations. The average heritabilities for milk acetone concentration were 0.29, 0.29, and 0.22 for parities 1, 2, and 3, respectively. There was no clear genetic association of the concentration of two ketone bodies with three test-day milk production traits, even if some correlations among breeding values of the test-day records in this study were observed. These results suggest that genetic selection for low susceptibility of ketosis in early lactation is possible. Further, it is desirable for the breeding scheme of dairy cattle to include the records of milk acetone rather than the records of milk BHBA.

Efficient Verification of X-ray Target Replacement for the C-series High Energy Linear Accelerator

  • Cho, Jin Dong;Chun, Minsoo;Son, Jaeman;An, Hyun Joon;Yoon, Jeongmin;Choi, Chang Heon;Kim, Jung-in;Park, Jong Min;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.29 no.3
    • /
    • pp.92-100
    • /
    • 2018
  • The manufacturer of a linear accelerator (LINAC) has reported that the target melting phenomenon could be caused by a non-recommended output setting and the excessive use of monitor unit (MU) with intensity-modulated radiation therapy (IMRT). Due to these reasons, we observed an unexpected beam interruption during the treatment of a patient in our institution. The target status was inspected and a replacement of the target was determined. After the target replacement, the beam profile was adjusted to the machine commissioning beam data, and the absolute doses-to-water for 6 MV and 10 MV photon beams were calibrated according to American Association of Physicists in Medicine (AAPM) Task Group (TG)-51 protocol. To verify the beam data after target replacement, the beam flatness, symmetry, output factor, and percent depth dose (PDD) were measured and compared with the commissioning data. The difference between the referenced and measured data for flatness and symmetry exhibited a coincidence within 0.3% for both 6 MV and 10 MV, and the difference of the PDD at 10 cm depth ($PDD_{10}$) was also within 0.3% for both photon energies. Also, patient-specific quality assurances (QAs) were performed with gamma analysis using a 2-D diode and ion chamber array detector for eight patients. The average gamma passing rates for all patients for the relative dose distribution was $99.1%{\pm}1.0%$, and those for absolute dose distribution was $97.2%{\pm}2.7%$, which means the gamma analysis results were all clinically acceptable. In this study, we recommend that the beam characteristics, such as beam profile, depth dose, and output factors, should be examined. Further, patient-specific QAs should be performed to verify the changes in the overall beam delivery system when a target replacement is inevitable; although it is more important to check the beam output in a daily routine.

Optimal Scheduling of SAD Algorithm on VLIW-Based High Performance DSP (VLIW 기반 고성능 DSP에서의 SAD 알고리즘 최적화 스케줄링)

  • Yu, Hui-Jae;Jung, Sou-Hwan;Chung, Sun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.262-272
    • /
    • 2007
  • SAD (Sum of Absolute Difference) algorithm is the most frequently executing routine in motion estimation, which is the most demanding process in motion picture encoding. To enhance the performance of motion picture encoding on a VLIW processor, an optimal implementation of SAD algorithm on VLIW processor should be accomplished. In this paper, we propose an implementation of optimal scheduling of SAD algorithm with conditional branch on a VLIW-based high performance DSP. We first transform the nested loop with conditional branch of SAD algorithm into a single loop with conditional branch which has a large enough loop body to utilize fully the ILP capability of VLIW DSP and has a conditional branch to make the escape from loop to be achieved as soon as possible. And then we apply a modulo scheduling technique to the transformed single loop. We test the proposed implementation on TMS320C6713, and analyze the code size and performance with respect to processing time. Through experiments, it is shown that the SAD implementation proposed in this paper has small code size appropriate for embedded applications, and the H.263 encoder with the proposed SAD implementation performs better than other H.263 encoder with other SAD implementations.

Clinical Availability of Waters' Projection in Sinus Elevation Procedures (상악동 거상술 시 Waters' Projection의 유용성에 대한 임상적 연구)

  • Seo, Mi Hyun;Kim, Soung Min;Ha, Ji Young;Lee, Jeong Keun;Myoung, Hoon;Lee, Jong Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.2
    • /
    • pp.88-93
    • /
    • 2013
  • Purpose: Maxillary sinus elevation has been widely used to enable insertion of endosseous implants in severely resorbed maxilla. Maxillary sinusitis after this procedure was considered to be the major drawback, therefore, preoperative evaluation of paranasal sinus is considered to be important. In order to evaluate the condition of the sinus, we used Waters' projection. In this study, asymptomatic patients were evaluated by Waters' view, and compared to timing to assess the sinus cavity. Methods: The retrospective study was based on 14 patients who were performed sinus elevation surgery in Seoul National University Dental Hospital. These patients did not show any signs of maxillary sinusitis. These patients were taken Waters' view at preoperative, postoperative 1 day, 3 months, 6 months. In Waters' view, presence of air fluid level, radiopacity of sinus wall, or radiopacity of entire maxillary sinus were evaluated. The density, and sinus dimension changes were assessed using Adobe Photoshop CS5$^{(R)}$ (Adobe Systems Inc., San Jose, CA, USA). Results: Findings of Waters views in patients with clear maxillary sinus at preoperative time were followed by elevated sinus floor with transplanted bone, mucosal swelling, and air fluid level. At postoperative 3 months, and 6 months, the radiographic findings were similar to preoperative state. By contrast, patients with preoperative mucosal swelling, or haziness in sinus cavity showed radiopacity entire sinus in Waters' view. In cases of the patients who were treated with simultaneous treatment to mucosal swelling, good status of sinus cavity were found. Conclusion: Although Waters' projections provide the limited information, and is less sensitive method compared with computed tomography, it is simple, easy, and economical method to assess of maxillary sinus. We suggest using Waters' view as radiographic routine tool for evaluation of sinus condition, especially in the sinus elevation surgery.

Analysis of Trace Levels of Lodinated Trihalomethanes in Water Using Headspace - GC/ECD (Headspace - GC/ECD를 이용한 수중의 미량 요오드계 트리할로메탄류 분석)

  • Son, Hee-Jong;Song, Mi-Jung;Kim, Kyung-A;Yoom, Hoon-Sik;Choi, Jin-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • Trihalomethanes (THMs) are formed as a results of the reaction of residual chlorine, used as a disinfectant in drinking water, with the organic matter in raw water. Although chlorinated and brominated THMs are the most common disinfection byproducts (DBPs) reported, iodinated THMs (I-THMs) can be formed when iodide is present in raw water. I-THMs have been usually associated with several medicinal or pharmaceutical taste and odor problems and is a potential health concern since they have been reported to be more toxic than their brominated and chlorinated analogs. Currently, there is no published standard analytical method for I-THMs in water. An automated headspace-gas chromatography/electron capture detector (GC/ECD) technique was developed for routine analysis of 10 THMs including 6 I-THMs in water samples. The optimization of the method is discussed. The limits of detection (LOD) and limits of quantification (LOQ) range from 12 ng/L to 56 ng/L and from 38 ng/L to 178 ng/L for 10 THMs, respectively. Matrix effects in river water, sea water and wastewater treatment plant (WWTP) final effluent water were investigated and it was shown that the method is suitable for the analysis of trace levels of I-THMs, in a wide range of waters. The method developed in the present study has the advantage of being rapid, simple and sensitive.

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

A Study on the Evaluation of Simplification Algorithms Based on Map Generalization (지도 일반화에 따른 단순화 알고리즘의 평가에 관한 연구)

  • Kim, Kam-Lae;Lee, Ho-Nam;Park, In-Hae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.10 no.2
    • /
    • pp.63-71
    • /
    • 1992
  • The digital map database is often produced for multiple purposes, including mapping at multiple scales; it is increasingly rare that a base map is digitized for mapping at a single scale. The most important problems in process of line simplification in map generalization and multiple representation is that tolerance value selected for simplifying base map information must be modified as feature geometry varies within the digital file to ensure both accuracy and recognizability of graphic details on a generalized map. In this study, we explored various algorithms regarding to line simplication at many scales from a single digital file, and presents a rule by which to determine those scale at which line feature geometry might be expected to change in map representation. By applying two measured of displacement between a digitized line and its simplification, five algorithms have been evaluated. The results indicate that, of the five, the Douglas-Peucker routine produced less displacement between a line and its simplification. The research has proved to automating map simplification, incorporating numeric guidelines into digital environment about what magnitude and variation in geometric detail should be preserved as the digital data is simplified for representation at reduced map scales.

  • PDF

An Evaluation on the Radiation Shielding of the Radwaste Drum Assay Facility (방사성폐기물드럼 핵종재고량 평가시설 구축에 따른 방사선차폐 영향평가)

  • Ji, Young-Yong;Kwak, Kyung-Kil;Hong, Dae-Seok;Shon, Jong-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.117-123
    • /
    • 2012
  • In order to dispose of the LILW(low and intermediate level radioactive waste) stored at KAERI, the radwaste drum assay system will be introduced to evaluate the radioisotopes inventory of stored drums. At present, the construction project of the dedicated assay facility to operate it and carry out routine maintenance of that equipment has been conducting at the radwaste treatment facility. Since that facility will be constructed in front of a 1st radwaste storage facility as well as the radwaste drums to be assayed and the transmission source in the radwaste drum assay system are in that facility, they could act as the radioactive sources and then, would affect the dose rate at the inside and the outside of the facility. Therefore, the radiation shielding should be evaluated through the concrete wall near to the radioactive sources whether the wall thickness is sufficient against the regulations. In this study, the radiation safety for the concrete wall around the radiation controlled area in the radwaste drum assay facility was evaluated by the MCNP code. From the evaluation results, the thickness of those concrete walls which are under consideration of about 30 cm was enough to shield the radiation from the radioactive sources.

A Study on Clinical Hematology of Korean Cattle Resident in High-land (고지사육한우(高地飼育韓牛)의 임상혈액학적연구(臨床血液學的硏究))

  • Lee, Bang Whan;Ko, Kwang Du
    • Korean Journal of Veterinary Research
    • /
    • v.15 no.2
    • /
    • pp.161-176
    • /
    • 1975
  • In order to evaluate the epizootiological influence of high-land on cattle feeding, routine hematological observation, with additional examinations of feces and general clinical condition, was conducted comparing the high-land cows resident at altitude of 800 to 1,200 meters in Daegwanryeong to the low-land cows resident at altitudes of less than 100 meters in Samcheok and Gangneung. The high-land cows were divided into 3 groups such as group A, B and C, consisting of 15, 16 and 20 adult cows respectively, and among the 3 groups only group C was exposed to abrupt high-land cold before observation. The low-land cows, that is group D, were consisted of 25 adult cows. The results obtained in the survey were summarized as follows: 1. Number of erythrocytes, concentration of hemoglobin and packed cell volume were remarkably higher (p<0.01) in all of 3 groups (group A, B and C) of high-land cows than trios of low-land cows (group D). These higher values in high-land cows were ascribable to the better feeding and hygienic management, and lesser infestation of small-type Piroplasma (Theileria) and internal parasites in contrast with the low-land cows. 2. Remarkably higher value of mean corpuscular volume (p<0.01) and a tendency to lower value of mean corpuscular hemoglobin concentration were noted in group D in contrast with group A, B and C. The reason was attributed to the higher infestation (p<0.01) of smalltype piroplasma in low-land cows in contrast with high-land cows. 3. It was noticiable that even though lesser infestation of small type Piroplama in the highland cows was shown, a natural case of clinical small-type-piroplasmosis was found in high-land group B as well as a case in the low-land group D. The blood Pattern showed characteristic macrocytic-hypochromic-anemia with increased reticulocytes in both two cases (Table 7). 4. In the observation of leukocytic series, marked increase of eosinophils in group D was seen in accordance with heavy infestation of gastrointestinal nematodes, and increased neutrophils with higher appearance of nonlobulated form and eosinopenia in group C only was observed suggesting the leukocytic response to the cold exposure in high-land. 5. Mean values of thrombocytes in group A,B,C and D were 48.4, 40.7, 42.7 and $32.3{\times}10^4/mm^3$ respcetively, and no statistically significant differences were observed.

  • PDF