• Title/Summary/Keyword: IT Routine

Search Result 1,044, Processing Time 0.023 seconds

Surgical anatomy for Asian rhinoplasty

  • Kim, Taek Kyun;Jeong, Jae Yong
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.147-157
    • /
    • 2019
  • Surgical anatomy is an important and fundamental aspect for all surgical procedures. Anatomy provides a surgeon with the basic and in-depth knowledge that is required and mandatory when performing an operation. Although this subject might be tedious and routine, it is compulsory and should not be overlooked or neglected to avoid any possible postoperative complications. An aggressive and hasty operation without anatomic considerations might cause adverse effects that are irreversible even though a surgical anatomy of the nose is quite simple.

A Study on the Improvement in Image of Police Box (파출소 이미지 개선에 관한 연구)

  • 이정림
    • Korean Institute of Interior Design Journal
    • /
    • no.9
    • /
    • pp.116-126
    • /
    • 1996
  • Modern society has achieved rapid growth in economy and materials whereas it caused such problems as municipal extension and high density of population, Due to rapid change of social environment, it became more complicated and multifarious than ever it before. Helping the people all kinds of routine affairs police box is giving a negative image to the citizens, for its environment doesn't have got rid of its old fashion . It's being an unharmonious factor to its surroundings, a solution is needed. So, this study is focused on recognizing the change of value system with the flow of time, planning a new image of police box for the change and in consequence recovering the trustworthy between people and the nation. For this , by grasping the characteristics of each space and through space-dividing and design corresponding to it, the plan is provided to make a pleasant interior environment of police box and to make it a symbol of local society. As a result of this study, we will have the police box not only as an office providing the locals with security and service but also as eyes of the country which watches the municipal environment.

  • PDF

Evaluation of Temporomandibular Disorders with Tension-Type Headache by Gender (성별에 따른 측두하악장애 환자의 긴장성 두통 양상)

  • Ko, Seok-Ho;Kang, Soo-Kyung;Auh, Q-Schick;Hong, Jung-Pyo;Chun, Yang-Hyun
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.303-316
    • /
    • 2009
  • This study was designed to evaluate the Temporomandibular Disorders(TMD) with Tension-Type Headache(TTH) by gender. Patients with TMD and/or TTH visited the Department of Oral Medicine, Kyung Hee University Dental Hospital were recruited to this study. Experimental group(n=60) is composed of TMD with TTH and control group(n=111) is composed of TMD without TTH. Evaluation list was pain quality, pain intensity, pain laterality, pain increase by routine physical activity and then it was analyzed statistically. The results were as follows ; 1. In the control group, pain quality was significantly different by gender(p=0.04). But, in the experimental group, pain quality was not significantly different by gender. 2. In the control group, pain intensity was not significantly different by gender. And, in the experimental group, pain intensity was not significantly different by gender. 3. In the control group, pain laterality was not significantly different by gender. And, in the experimental group, pain laterality was not significantly different by gender. 4. In the control group, pain increase by routine physical activity was not significantly different by gender. And, in the experimental group, pain increase by routine physical activity was not significantly different by gender. Therefore, it is considered that not temporomandibular disorder patients with tension-type headache but temporomandibular disorder patients without tension-type headache was influenced by gender in the pain quality.

Evaluation of Temporomandibular Disorders with Tension-Type Headache by Age (연령에 따른 측두하악장애 환자의 긴장성 두통 양상)

  • Muhn, Kyung-Hwan;Chun, Yang-Hyun;Hong, Jung-Pyo;Auh, Q-Schick
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.103-114
    • /
    • 2009
  • This study was designed to evaluate the Temporomandibular Disorders(TMD) with Tension-Type Headache(TTH) by age. Patients with TMD and/or TTH visited the Department of Oral Medicine, Kyung Hee University Dental Hospital were recruited to this study. Experimental group(n=170) is composed of TMD with TTH and control group(n=222) is composed of TMD without TTH. Evaluation list was pain quality, pain intensity, pain laterality, pain increase by routine physical activity and then it was analyzed statistically. The results were as follows ; 1. In the control group, pain quality was not significantly different by age. But, in the experimental group, pain quality was significantly different by age(p=0.042). 2. In the control group, pain intensity was significantly different by age(p=0.000). And, in the experimental group, pain intensity was significantly different by age(p=0.004). 3. In the control group, pain laterality was not significantly different by age. And, in the experimental group, pain laterality was not significantly different by age. 4. In the control group, pain increase by routine physical activity was not significantly different by age. And, in the experimental group, pain increase by routine physical activity was not significantly different by age. Therefore, it is considered that not temporomandibular disorder patients without tension-type headache but temporomandibular disorder patients with tension-type headache was influenced by age in the pain quality.

Development of an Automated Synthesizer for the Routine Production of Ga-68 Radiopharmaceuticals (임상용 Ga-68 표지 방사성의약품의 합성을 위한 자동합성장치 개발)

  • Jun Young PARK;Jeongmin SON;Won Jun KANG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.4
    • /
    • pp.253-260
    • /
    • 2023
  • The germanium-68/gallium-68 (68Ge/68Ga) generator has high spatial utilization and requires little maintenance, making it economical and easy to produce. Thus, the frequency of use of 68Ga radiopharmaceuticals is rapidly increasing worldwide. Therefore, this study attempted to develop an automated synthesizer for the routine clinical application of 68Ga radiopharmaceuticals. The automated synthesizer was based on a fixed tubing system and the structure was designed after adjusting the position of the parts to reflect the synthesis method. Using various components that can be supplied in Korea, the automated synthesizer was manufactured at a much lower price cost than that of a commercialized automated synthesizer sold by companies. 68Ga-DOTA-[Tyr3]-octreotide (68Ga-DOTATOC) was synthesized to evaluate the performance of the automated synthesizer. 68Ga-DOTATOC could be synthesized with about 65% of non-decay corrected yield, and the synthesized 68Ga-DOTATOC met all quality control standards. We have synthesized 68Ga-DOTATOC more than 100 times, and only faced a few problems caused by mechanical errors. In this study, we successfully developed a simple automated synthesizer for 68Ga radiopharmaceuticals with high reproducibility. As various 68Ga radiopharmaceuticals have recently been developed, it is expected that the automated synthesizer developed in this study will be useful for routine clinical use.

Development of exchange period program for chemical cartridge feasible in the work spot (1) - Experiment of estimated breakthrough time using discarded cartridges (작업장에서 사용 가능한 방독마스크 정화통 교체주기 프로그램의 개발(I) - 폐정화통을 이용한 파과시간 예측 실험)

  • Han, Don-Hee;Lee, Sang-Young
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.204-215
    • /
    • 2008
  • Many researches for service-life of chemical cartridges of respirators have been performed in many countries. On the result of these researches a few softwares programs were eventually developed to be used. In spite of that, it is difficult to apply these researches and softwares practically in the work spot because of too many factors that influence on service-life of chemical cartridges. This study was the first of two conducted for the purpose of developing program for estimating exchange period or service-life of chemical cartridges available feasibly in the workplaces. Collecting plan of cartridges discarded after use is in principle that three cartridges from three workers at a time, three steps of 1/2 exchange time due to smelling, just routine exchange time and 1.2 to 1.3 expanded time of routine exchange, total nine cartridges are collected in the same job site. 33 cartridges for organic vapor were collected in paint spray process of ship yard and paint factory, and 6 cartridges for acid were collected in plating process. These cartridges were analysed the remaining breakthrough time in 3M Innovation Center. Challenge vapor and breakthrough concentration were complied with Korean regulation for chemical cartridge respirators. Estimated breakthrough time was determined from previously used time plus breakthrough time for the remaining. Exchange period of cartridge would be the shortest time among three estimated breakthrough times. On the result breakthrough time for organic vapor was found to be relatively easily estimated, but that for acid aerosol or vapor was difficult to be confident. Even though this method was difficult to be precisely predicted exchange period of cartridge, it could be an alternative program practically available in the job site.

Instruction-corruption-less Binary Modification Mechanism for Static Stack Protections (이진 조작을 통한 정적 스택 보호 시 발생하는 명령어 밀림현상 방지 기법)

  • Lee, Young-Rim;Kim, Young-Pil;Yoo, Hyuck
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.1
    • /
    • pp.71-75
    • /
    • 2008
  • Many sensor operating systems have memory limitation constraint; therefore, stack memory areas of threads resides in a single memory space. Because most target platforms do not have hardware MMY (Memory Management Unit), it is difficult to protect each stack area. The method to solve this problem is to exchange original stack handling instructions in binary code for wrapper routines to protect stack area. In this exchanging phase, instruction corruption problem occurs due to difference of each instruction length between stack handling instructions and branch instructions. In this paper, we propose the algorithm to call a target routine without instruction corruption problem. This algorithm can reach a target routine by repeating branch instructions to have a short range. Our solution makes it easy to apply security patch and maintain upgrade of software of sensor node.

Coupled analysis for the stability estimation of a subsea tunnel in discontinuous rock masses using sensitivity analysis (민감도 분석을 통한 불연속 암반 내의 해저터널의 안정성 평가를 위한 연계해석)

  • You, Kwang-Ho;Lee, Dong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.421-430
    • /
    • 2008
  • In discontinuous rock masses, hydraulic-mechanical coupled analyses are required since groundwater flow in joints have a great influence on the stability of a subsea tunnel. In this study, a sensitivity analysis was performed based on coupled analysis to verify the routine which can estimate the safety factor of a tunnel in discontinuous rock mass. To this end, 324 cases of numerical calculations were performed with a commercial program, UDEC-2D. As a result, it was confirmed that the proposed routine for coupled analysis in discontinuous rock mass could give a reasonable result for the estimation of safety factor of a tunnel. Therefore, it is expected that the safety factor estimation method used in this study can be effectively applied for the stability estimation of a subsea tunnel in discontinuous rock masses.

  • PDF

Reliability Analysis and Utilization of BIM-based Highway Construction Output Volume (BIM기반 고속도로 공사 물량산출 신뢰성 검토 및 활용)

  • Jung, Guk-Young;Woo, Jeong-Won;Kang, Kyeong-Don;Shin, Jae-Choul
    • Journal of KIBIM
    • /
    • v.3 no.3
    • /
    • pp.9-18
    • /
    • 2013
  • In case of applying the BIM method in the civil engineering of irregularly shaped structure, BIM method began to be introduced in the current building engineering area compared with the expected effects of the relatively high construction productivity has been recognized. In this paper, I have developed quantity calculation algorithms applying it to earthwork and bridge construction, tunnel construction, retaining wall construction, culvert construction and implemented BIM based 3D-BIM Modeling quantity calculation. Structure work in which errors occurred in range between -6.28% ~ 5.17%. Especially, understanding of the problem and improvement of the existing 2D-CAD based of quantity calculation through rock type quantity calculation error in range of -14.36% ~ 13.07% of earthwork quantity calculation. It's benefit and applicability of BIM method in civil engineering. In addition, routine method for quantity of earthwork has the same error tolerance negligible for that of structure work. But, rock type's quantity calculated as the error appears significantly to the reliability of 2D-based volume calculation shows that the problem could be. Through the estimating quantity of earthwork based 3D-BIM, proposed method has better reliability than routine method. BIM, as well as the design, construction, maintenance levels of information when you consider the benefits of integration, the introduction of BIM design in civil engineering and the possibility of applying for the effectiveness was confirmed. In addition, as the beginning phase of information integration, quantity document automation program has been developed for activation of BIM. And automatically enter the program code number, linkage and manual volume calculation program, quantity document automation programs, such as the development is now underway, and step-by-step procedures and methods are presented.

Modified Toluidine Blue: an Alternative Stain for Helicobacter pylori Detection in Routine Diagnostic Use and Post-eradication Confirmation for Gastric Cancer Prevention

  • Sakonlaya, Dussadee;Apisarnthanarak, Anucha;Yamada, Nobutaka;Tomtitchong, Prakitpunthu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6983-6987
    • /
    • 2014
  • Background: Modified toluidine blue staining (MTBs) is a simple, inexpensive and time saving method to detect H. pylori in gastric biopsy specimens. As a metachromatic stain, it simultaneously highlights intestinal metaplasia, a gastric cancer precancerous lesion. The aim of this study was to assess the reliability of MTBs compared with hematoxylin-eosin (H&E) for H. pylori detection using immunoperoxidase staining as the gold standard. This technique would be beneficial for a routine diagnosis and confirmation of H. pylori eradication in developing countries where endoscopic-based approaches are dominant. Materials and Methods: Esophagogastroduodenoscopy with triple site gastric biopsies was undertaken in 207 dyspeptic patients at Thammasat University Hospital, Thailand between 1997 and 1999. H&E, MTBs and immunoperoxidase staining were applied to each specimen. The presence or absence of H. pylori with each stain was interpreted separately and the sensitivity, specificity, positive and negative predictive values of H&E and MTBs were calculated. Results: A total of 282 specimens from 207 patients were evaluated. Using immunoperoxidase staining, organisms were positive in 117 specimens (41%). MTBs proved almost equally sensitive as immunoperoxidase (99%) and significantly more sensitive than H&E (85%). It has comparable specificity (96% vs 96%), PPV (95% vs 94%), and NPV (99% vs 90%) to H&E, using immunoperoxidase staining as gold standard. MTBs compared with immunoperoxidase staining, is cheaper (2 USD vs 12 USD) and faster (20 min vs 16 hrs) compared to immunoperoxidase staining. Conclusions: MTBs is effective, economical and easy to use in daily practice for the detection of H. pylori in gastric biopsy specimens. In addition to saving time in evaluating H. pylori associated gastritis, with a high sensitivity and ability to demonstrate intestinal metaplasia, the technique may have a role in confirmation of H. pylori eradication for gastric cancer prevention in a developing country setting.