Development of exchange period program for chemical cartridge feasible in the work spot (1) - Experiment of estimated breakthrough time using discarded cartridges

작업장에서 사용 가능한 방독마스크 정화통 교체주기 프로그램의 개발(I) - 폐정화통을 이용한 파과시간 예측 실험

  • Received : 2008.07.11
  • Accepted : 2008.09.18
  • Published : 2008.09.30

Abstract

Many researches for service-life of chemical cartridges of respirators have been performed in many countries. On the result of these researches a few softwares programs were eventually developed to be used. In spite of that, it is difficult to apply these researches and softwares practically in the work spot because of too many factors that influence on service-life of chemical cartridges. This study was the first of two conducted for the purpose of developing program for estimating exchange period or service-life of chemical cartridges available feasibly in the workplaces. Collecting plan of cartridges discarded after use is in principle that three cartridges from three workers at a time, three steps of 1/2 exchange time due to smelling, just routine exchange time and 1.2 to 1.3 expanded time of routine exchange, total nine cartridges are collected in the same job site. 33 cartridges for organic vapor were collected in paint spray process of ship yard and paint factory, and 6 cartridges for acid were collected in plating process. These cartridges were analysed the remaining breakthrough time in 3M Innovation Center. Challenge vapor and breakthrough concentration were complied with Korean regulation for chemical cartridge respirators. Estimated breakthrough time was determined from previously used time plus breakthrough time for the remaining. Exchange period of cartridge would be the shortest time among three estimated breakthrough times. On the result breakthrough time for organic vapor was found to be relatively easily estimated, but that for acid aerosol or vapor was difficult to be confident. Even though this method was difficult to be precisely predicted exchange period of cartridge, it could be an alternative program practically available in the job site.

Keywords

Acknowledgement

Supported by : 산업안전보건연구원

References

  1. 김기환, 김덕기, 신창섭. 작업현장의 환경조건에 따른 방독마스크 정화통의 수명예측(II). 한국산업안전학회지 1996;11(4): 72-78
  2. 김덕기, 신창섭. 작업현장의 환경조건에 따른 방독마스크 정화통의 수명예측 -모사에 의한 정화통과 샘플관의 파과시간-, 한국산업안전학회지 1996;11(2): 89- 95
  3. 노동부. 보호구 성능검정 규정 (방독마스크). 노동부 고시 2004-49 (2004. 10. 21.). 노동부 2004
  4. 박두용, 박지영, 윤충식. 가스 및 유기용제용 호흡용보호구의 정화통에 대한 수명예측방법의 정확도 및 타당성 검증연구. 한국산업위생학회지 1999;9(2): 19-31
  5. 정해동, 백남원. 복합유기용제에 노출된 호흡용보호구용 정화통의 파과에 관한 연구. 한국산업위생학회지 1996;6(1): 55-66
  6. 한국산업안전공단. 작업환경측정.분석방법 지침 [KOSHA CODE A-1-2004]. 한국산업안전공단 2004
  7. Cohen, HJ, SP Levine, RP Garrison. Development of a field method for determination the service lives of respirator cartridges - Part IV: Results of field validation trials. Am. Ind. Hyg. Assoc. J. 1991 52(7): 263-270 https://doi.org/10.1080/15298669191364712
  8. Nelson, GO and AN Correia. Respirator cartridge efficiency studies: VII - Summary and conclusions, Am. Ind. Hyg. Assoc. J. 1976);37(9): 514-525 https://doi.org/10.1080/0002889768507509
  9. Nelson, GO and CA Harder. Respirator cartridge efficiency studies: V - Effect of solvent vapor. Am. Ind. Hyg. Assoc. J. 1974;35(7): 391-410 https://doi.org/10.1080/0002889748507051
  10. Rajhans, GS and BP Pathak. Practical guide to respirator usage in industry, 2nd ed., Butterworth-Heinemann, 2001
  11. Tanaka, S, Y Tsuda, S Kitamura, M Shimada, H Arito, Y Seki. A simple method for detecting breakthroughs in used chemical cartridges, Am. Ind. Hyg. Assoc. J. 1991;62(2): 168-171
  12. Yoon, YH, JH Nelson, J Lara, C Kamel, D Fregeau. A theoretical interpretation of the service life of respirator cartridges for the binary acetone/m-xylene system, Am. Ind. Hyg. Assoc. J. 1991;52(2): 65-74 https://doi.org/10.1080/15298669191364343