• Title/Summary/Keyword: IT Efficiency

Search Result 24,602, Processing Time 0.044 seconds

Design of a High-efficiency Fiber-to-chip Coupler with Reflectors

  • Yoo, Keon;Lee, Jong-Ho
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.2
    • /
    • pp.123-128
    • /
    • 2016
  • In this paper, an inversely tapered coupler with Bragg reflectors is reported for the first time. With appropriately positioned reflecting structures, our fiber-to-chip coupler can more efficiently transmit the light from fiber to a waveguide in a photonic integrated circuit (PIC). A numerical simulation evaluated the coupler's efficiency with the reflector. Optimized parameters that maximize the efficiency of the coupler are also investigated. Simulation results show that the reflector with appropriate parameters enhances efficiency by up to 7 dB. Likewise, Bragg metal reflectors implemented by the conventional metallization process can also improve efficiency. It is also shown that the proposed reflector enhances the coupling efficiency in a double-tip taper coupler.

Productivity Evaluation and Comparision of Korean Provincial Hospitals (한국 지방공사 의료원의 생산성 평가와 비교)

  • Ahn, Tae-Sik;Park, Jung-Sik
    • Korea Journal of Hospital Management
    • /
    • v.2 no.1
    • /
    • pp.22-47
    • /
    • 1997
  • This paper evaluated the relative efficiency of 33 provincial medical centers using Data Envelopment Analysis(DEA) and compared the DEA efficiency results with those of the current method conducted by the management evaluation team. DEA Was selected as an alternative efficiency evaluation method since it could handle multiple inputs and multiple outputs simultaneously and identify the sources of inefficiency. To analyze the sensitivity of productivity values to the variable sets, four different sets of input and output variables were identified. Results showed that most of the medical centers are operating far away from the efficiency frontier supporting the previous results. Some centers showed 100% efficiency regardless of the selected variable sets. DEA results are compared with current management evaluation results. Some inconsistencies were found for some DMUs between the results of two methods showing the existence of methodology bias. DEA results and ratio analyses results mostly agree for 1992 data.

  • PDF

High Efficiency Tracking Drive in DC Motor by Field Winding Switching Method (계자권선 절환에 의한 직류전동기의 고효율 추종 운전)

  • Yoon, Ki-Jeong;Kim, Kwang-Heon
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.493-496
    • /
    • 1997
  • This paper constructed the experimental system which is able to drive in series or separately excited by switching of the field winding, using a DC motor and obtained the characteristics of efficiency with speed and torque of each motor's type through the experiment. From this result controlled drive which is able to series DCM or separately excited DCM in the optimal point of efficiency as finding the types of motor having maximum efficiency with torque and speed. By performing high efficiency tracking drive, it is expected that energy consumption of power source with limited energy density would be reduced, and so utility efficiency would be improved.

  • PDF

A Study on the MPPT Control Algorithm and Efficiency Evaluation Method (MPPT제어 알고리즘 고찰 및 효율시험 평가법)

  • 유권종;김기현;정영석;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.164-172
    • /
    • 2001
  • This paper describes common MPPT(Maximum Power Point Tracking) control algorithm; Constant Voltage Control, P&O(Perturbation and Observation), IncCond(Incremental Conductance), and investigated it\`s efficiency. Though simulation and efficiency evaluation, the steady/transient states characteristics and efficiency of control algorithms are analyzed respectively. Also, two-mode MPPT control to improve on the existing control algorithm. Moreover, is proposed for high efficiency this paper suggests a topology for MPPT measuring efficiency and a method of examination.

  • PDF

A prediction of the scavenging efficiency and the performance of a two-stoke SI engine with the different exhaust systems (배기관 형상에 따른 2행정기관의 소기효율 및 성능 예측)

  • Chung, J.E.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.2
    • /
    • pp.130-135
    • /
    • 1995
  • In this paper, the numerical simulation of the method of characteristics for a two-stroke SI engine was carried out, and the scavenging efficiency and the performance of single engine with two types of exhaust system, that is, a pipe exhaust system and a tuned exhaust system, were predicted and compared. The conculusions are obtained as follows. (1) The method of characteristics of hometropic flow considering the friction and the variation of area is useful to predict the scavenging efficiency and the performance of the two-stroke engine. (2) The shape of exhaust system effects directly on the scavenging and the trapping efficiency. (3) A tuned exhaust system consisted of the diffuser and the convergent nozzle makes the plugging pulse and therefore enhances the scavenging and the trapping efficiency. (4) It may be possible to design the optimum exhaust system by using the plugging pulse.

  • PDF

Optimization of the Plasma Spray Coating Parameters of Ni-5%Al Alloy Powder Using the Taguchi Experimental Method (다꾸찌방법에 의한 Ni-5%Al 합금 분말의 플라즈마 용사코팅 조건의 최적화)

  • 이형근
    • Journal of Welding and Joining
    • /
    • v.20 no.5
    • /
    • pp.120-126
    • /
    • 2002
  • Ni-5%Al alloy powder is widely used as the bond coating powder to improve the adhesive strength between the substrate and coating. The important properties in the bond coating are the deposition efficiency and surface roughness. In this study, it was tried to optimize the plasma spray parameters to maximize the deposition efficiency and surface roughness. In the first step, spray current and hydrogen gas flow rate were optimized in order to increase the deposition efficiency. In the next step, the seven plasma spray variables were selected and optimized to improve both the deposition efficiency and surface roughness using the Taguchi experimental method. By these optimization, the deposition efficiency was improved from about 10 % at the frist time to 51.2 % by the optimization of spray current and hydrogen gas flow rate and finally to 65.2 % by the Taguchi experimental method. The average surface roughness was increased from about $12.9\mu\textrm{m}$ to $15.4\mu\textrm{m}$.

A Study on the Two-Mode MPPT Control Algorithm and Efficiency Evaluation Method (Two-Mode MPPT 알고리즘 연구 및 효율평가법)

  • Yu, Gwon-Jong;Kim, Ki-Hyun;Jung, Young-Seok;Kim, Young-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • In this paper described common MPPT(Maximum Power Point Tracking) control algorithm; Constant Voltage Control, P&O(Perturbation and Observation), IncCond(Incremental Conductance), and investigated it's efficiency. Through simulation and efficiency evaluation, analyze the steady/transient states characteristics and efficiency of control algorithms respectively. Also, To high-efficiency proposed Two-mode MPPT control for improve on the existing control algorithm. Moreover, this paper suggested a topology for MPPT measuring efficiency and a method of examination.

  • PDF

Numerical study for the fin efficiency of the heat exchanger having plate fins (판형 휜을 갖는 열교환기의 휜효율에 관한 수치해석적 연구)

  • 강희찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.903-911
    • /
    • 1999
  • This study is discussed about the heat transfer coefficient and the fin efficiency of the heat exchanger having plate fins. A new definition for the fin efficiency of the heat exchanger is proposed. More than one hundred cases were tested numerically for the plate fins having uniform and non-uniform heat transfer coefficient. The previous models for the fin efficiency and the pure heat transfer coefficient were applicable to the heat exchanger only when the NTU is very small. It was found that the fin efficiency of the heat exchanger was nearly the same as the normalized fin temperature. The present model could estimate the pure heat transfer coefficient within a few percent in the present test range of 0<NTU<2.5.

  • PDF

Static and Dynamic Analysis of Efficiency of Korean Regional Public Hospitals (지방의료원의 효율성에 대한 정태적 및 동태적 분석)

  • Kim, Jong-Ki;Jeon, Jinh-Wan
    • Korea Journal of Hospital Management
    • /
    • v.15 no.1
    • /
    • pp.27-48
    • /
    • 2010
  • The purpose of this paper is to analyze the efficiency change and its determinants of the regional public hospitals. We utilize 34 regional public hospital's panel data for 6 years from 2003 to 2008. We use DEA(Data Envelopment Analysis)-CCR, BCC model, DEA/Window model, and DEA Profiling. The empirical results show the following findings. First, technical efficiency shows that approximately 3.6% of inefficiency exists on the regional public hospitals and it reveals that the cause for technical inefficiency is due to scale inefficiency. Second, DEA/Window results show that the stable dissimilarity by standard deviation, LDP of CCR. Third, the results of partial efficiency by DEA Profiling show that increase efficiency depends on the number of beds, doctors, and nurses.

  • PDF

The Effects of Exhaust Gas Recirculation on Premixed Combustion System (배기가스 재순환 방식이 예혼합 연소시스템에 미치는 영향)

  • Yu, Byeonghun;Lee, Seungro;Kum, Sung-Min;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.1-3
    • /
    • 2013
  • The premixed combustion system applying exhaust gas recirculation was investigated to achieve the low pollutant emission and the high thermal efficiency. In this study, it was studied the effects of EGR on the thermal efficiency, $NO_x$ and CO emissions with various EGR ratios and equivalence ratios. As results, when equivalence ratio was increased, thermal efficiency increased and $NO_x$ and CO concentration increased. When EGR was applied, $NO_x$ and CO concentration decreased and thermal efficiency increased. Especially, in the case of 15% of EGR ratio at 0.85 of equivalence ratio, $NO_x$ and CO concentration will be a smaller than these of a current operating condition of the boiler and thermal efficiency was about 1.7% higher.

  • PDF