• Title/Summary/Keyword: IT Efficiency

Search Result 24,602, Processing Time 0.049 seconds

A Study on the Measurement System for Analyzing a Pump Efficiency (펌프효율분석을 위한 측정시스템에 관한 연구)

  • Bae, Cherl-O;Vuong, Duc-Phuc;Jung, Hye-Youn;Lee, Hwi-Il
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.129-129
    • /
    • 2012
  • Pumps are used widely in industry, the commercial sector and ships. A poorly selected pump or a pump that does not run at optimum design duty point is a classic symbol of wasted energy and money. It, therefore, becomes important to evaluate the efficiency of these pumps. This paper analyzes traditional technique and instrument to measure some parameters needed to calculate a pump efficiency. The pump efficiency measuring instrument (PEMI) was made and tested on real pump systems. It has been giver the accurate results compared with performance curve given by pump maker.

  • PDF

An Application of Total Quality Management Efficiency Model in the Korean Distribution Industry

  • Yoo, Han-Joo;Park, Jong-Woo;Song, Gwang-Suk
    • International Journal of Quality Innovation
    • /
    • v.10 no.1
    • /
    • pp.25-36
    • /
    • 2009
  • The purpose of this study is to analyze the efficiency of the service quality activity itself by using the DEA Model, in contrast to previous quality evaluation methods, as an attempt to evaluate the service quality activities of the distribution industry. Furthermore, by complementing the shortfalls of the weighted value of the DEA Model, it recommends a DEA/PS Model that is appropriate in the evaluation of service quality activities. Based on this model, the study proposes the SQAE Model, an evaluation tool to complement the traditional measuring method. According to the results of the analysis of 18 sample distribution businesses, there was a discrepancy by business in the results of the Traditional Scoring System and the Evaluation Measuring System. Therefore, it is most desirable to not only be active in service quality activities but also increase efficiency at the same time.

Performance Evaluation of Rice Mill Plant By a Computer Simulation

  • Chung, Jong-Hoon
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.1
    • /
    • pp.7-14
    • /
    • 2001
  • A rice mill plant with a capacity of 3 t/h was constructed with automated facilities at Chonnam National University. A simulation model was developed with SLAMSYSTEM for evaluation and improving the rice mill process. The developed model was validated in the views of hulling efficiency, milling efficiency, milled rice recovery, other materials produced, at bottlenecks in the processes. The results of hulling efficiency, milling efficiency, milled rice recovery in the simulation were, respectively, 81.1%, 89,5%, and 73.1%, while those of the actual mill plant were 81.5%, 90.2%, and 73.5%. The simulation results including the rates of other materials(chaff, bran, broken rice, stone, etc) produced in the processes were almost similar with those of the actual process. In the simulation the bottlenecks were found out in the process for separating brown rice and sorting colored rice. These phenomena also appeared in the actual process. It needed to increase the hourly capacities of the brown rice separator and the rice color sorter. As the developed model could well express the automated rice mill plant, it could be used for designing and improving rice mill plants.

  • PDF

Incipient Cavitation in a Bulb Turbine: Model Test and CFD Calculation

  • Necker, Jorg;Aschenbrenner, Thomas
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.140-149
    • /
    • 2011
  • For a certain operating point of a horizontal shaft bulb turbine (i.e. volume flow, net head, blade angle, guide vane angle) the efficiency for different pressure levels (i.e. different Thoma-coefficient ${\sigma}$) is calculated using a commercial Computational Fluid Dynamics (CFD-)-code including two-phase flow and a cavitation model. The results are compared with experimental results achieved at a closed loop test rig for model turbines. The comparison of the experimentally and numerically obtained efficiency and the visual impression of the cavitation show a good agreement. Especially the drop in efficiency is calculated with satisfying accuracy. This drop in efficiency in combination with the visual impression is of high practical importance since it contributes to determine the admissible cavitation in a bulb-turbine. It is seen that the incipient cavitation in Kaplan type turbines has no major importance in determing this admissible amount of cavitation.

A study on the high efficiency power supply for 550W class PDP (550W급 PDP용 고효율 전원 장치에 관한 연구)

  • Won, Ki-Sik;Ahn, Tae-Young;Park, No-Soung;Cho, In-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.459-462
    • /
    • 2005
  • Recently, the PDP is the most remarkable media for a next generation display device. But the PDP is a high power consumption device. It is to required a high efficiency power supply. We reported the experimental result the high efficiency PDP power supply for 550w class. The proposed converter is quasi-resonant flyback topology, it achieves soft-switching in the single-switch flyback converter. As a result, we realize to very high efficiency power supply for PDP of 95% at 400v dc input and 550Watt output.

  • PDF

Comparisons of Dust Collection Efficiency on the Tangental Entry and Axial-vane Type Cyclone (접선유입식과 축상유입식 사이클론의 집진효율 비교)

  • Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.115-121
    • /
    • 2011
  • This study is about comparison of tangental entry type cyclone dust collector with axial vane type cyclone dust collector. Cut diameter and dust collection efficiency of both collector was compared by theory and experiment. Cut diameter was calculated by an quasi-empirical formula by Lapple and Shepherd. Measurement of cut diameter was conducted by particle counter through dust generator. As the result, cut diameter obtained by experiment was a little larger than that by theory. But the error is within $0.5{\mu}m$ in both type of collector, so it could be confirmed that theoretical value and experimental value were almost identical. And, as flow rate increased, dust collection efficiency was increased. Also axial vane type showed higher dust collection efficiency than tangental entry type. Therefore, it can be said that axial vane type cyclone dust collector has higher performance than the other.

Study on the Control Performance Evaluation of the Exhaust Stack used in High Riser Public House (초고층공동주택 국소배기용 입상덕트시스템의 제어성능평가에 관한 연구)

  • Kwon, Yong-Il;Ahn, Jung-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.103-108
    • /
    • 2009
  • Local exhaust system used in toilet and cooking place of low-rise public house installed roof ventilator at terminal of stack. There are many high riser public houses in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser public house depends on stack effect. But Neutral pressure level represents in a terminal of stack with air tightness for the best exhaust efficiency. Thereby, lower floors have the worst indoor air quality. This paper focuses mainly on the exhaust efficiency improved by roof fan with motor installed in high riser public house. It is observed there is higher exhaust efficiency than the existing natural roof ventilator.

CLHS Driving Method for Reducing Reactive Power Consumption in AC PDP (AC PDP의 무효전력 감소를 위한 CLHS 구동 방법)

  • Shin, Jae-Hwa;Kim, Gun-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.577-583
    • /
    • 2011
  • In AC-PDP, it is necessary to achieve high luminance efficiency, high luminance and high definition by adopting technologies such as high xenon concentration and long gap. However, it is very difficult to apply above technologies because they make many problems such as mis-discharge and high driving voltage. Especially, the reactive power of PDP must be reduced for satisfaction in international standard IEC62087. In this paper, we proposed CLHS driving method which is half sustain driver without energy recovery capacitor. In the experimental results, CLHS driving method reduced reactive power consumption about 10%. Also, CLHS driving method improved the luminance efficiency in all discharge loads. Therefor, the more the discharge load decreases, the more the luminance efficiency improves. When the discharge load is 20%, CLHS driving method improved 5.35%.

A Simulation Study on Efficiency of Container Crane in Container Terminal (컨테이너 터미널에서 컨테이너 크레인의 하역능력 추정에 관한 시뮬레이션 연구)

  • Yun, Won-Young;Choi, Yong-Seok;Song, Jin-Young;Yang, Chang-Ho
    • IE interfaces
    • /
    • v.14 no.1
    • /
    • pp.67-78
    • /
    • 2001
  • This paper describes the simulation study which estimates the container crane efficiency in container terminal. In most simulation studies, it is assumed that container cranes are available at any time. Though the failures of container cranes don't occur often, they are very serious problems on terminal efficiency. As usual, the failures of container crane cause arrived ships to delay the departure time. In this study, a queueing simulation model for container terminal, which focuses on the failures of container cranes, is designed. The simulation approach appears to be the most appropriate one because it allows to avoid the usual exponential assumption on interarrivals of ships and service times of container cranes. Using the developed model, we tested the efficiency of container cranes considering failures with a real system size and performed the simulation experiment on real container terminal to validate the developed simulation model. The results of simulation experiment were analyzed using output statistics, which include the waiting times of vessels and yard tractors, the utilization for container cranes, and the berth occupancy rates.

  • PDF

Novel Energy Recovery Circuit for High Efficiency Flyback Converter (고효율 플라이백 컨버터를 위한 새로운 에너지 회복회로)

  • Jung, Yong-Chae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.529-534
    • /
    • 2006
  • Nowadays, more than ever before, many researchers take much interest in raising the efficiency of a power converter. In Flyback converter, the resistor of RCD snubber consumes the stored energy in leakage inductor. It plays a role in degrading the overall system efficiency. Thus, in this paper, a novel energy recovery circuit of Flyback converter is proposed to improve the efficiency. The operational principle of the proposed circuit is explained in detail. And, it is vilified through the simulation and experimental results.