• Title/Summary/Keyword: IT Corporation

Search Result 4,927, Processing Time 0.031 seconds

Research and Development of High Luminous Efficacy Plasma Displays

  • Kosugi, Naoki;Akiyama, Toshiyuki;Kitagawa, Masatoshi;Shinodaq, Tsutae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.57-60
    • /
    • 2008
  • Over 5lm/W white luminous efficacy was obtained by 11" color test panel with narrowed discharge electrodes combined with high Xe partial pressure. By using optical spectroscopic methods, it was suggested that the electron heating efficiency is the most significant to improve the plasma efficiency in our experimental conditions.

  • PDF

Field emission display with catalysis cathode film material for graphite nano fiber

  • Kageyama, Kagehiro;Kojima, Tomoaki;Hirakawa, Masaaki;Sasaki, Takaei
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.146-149
    • /
    • 2006
  • We developed new FED cathode film material that has catalysis function for graphite nano fiber. Using the cathode film with catalyst, we can simplify the FED process. It is composed of Cr, Fe-Ni catalyst. Fabricating FED panel with the film, we confirmed good emission performance of the panel.

  • PDF

Influence of air pressure, temperature, humidity and CO$_{2}$ concentration on optical phase changes in thin films

  • Kim, Moon-Hwan;Tachikawa, Yoshihiko;Ogita, Eiji;Ueda, Toshitsugu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.799-804
    • /
    • 1989
  • A new method for measuring optical phase changes of reflection beam from optical mirror is proposed. The optical phase change is liable to change with varying atmosphere conditions. This optical phase changes are measured against air pressure, temperature, humidity and CO$\_$2/ concentration variations. It is clarified that the optical phase changes are most effected by humidity change.

  • PDF

New Photo-Alignment Materials for LCD as a Non-Rubbing Method.

  • Kumano, Atsushi;Takeuchi, Yasumasa;Nakata, Shoichi;Kimura, Masayuki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.953-956
    • /
    • 2002
  • We successfully developed new photo-alignment materials which can be treated with linearly polarized UV (LPUV) light in near UV region. The alignment films were also shown to provide with surface anchoring as strong as that on rubbed polyimide when exposed to the LPUV light with warming up the substrate. It can be also able to control pretilt angle by introduction of alkyl side chain.

  • PDF

Development of Modular Scaffold for Overhead Transmission Line Wiring Work (송전선로 가선공사용 모듈형 발받침 개발)

  • Min, Byeong-Wook;Baik, Seung-Do;Kang, Dae-Eon;Bang, Hang-Kwon;Choi, Jin-Sung;Baek, Soo-Gon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.450-451
    • /
    • 2006
  • The method of conductor wiring is that a messenger wire is installed, the end of the wire is connected to the conductor and a engine puller pulls the conductor. The length of one section of wiring is $3{\sim}5km$ and one group messenger wire pulls simultaneously $2{\sim}4$ group conductor, while a tensioner maintains wiring tension to prevent the deflection of the conductor. However, there are many obstacles such as roads, power lines, communication lines, buildings, farms and crops. Therefore to prevent damage from conductor deflection a staging is used. The currently used staging is scaffolding lumber which is difficult to secure and it's construction efficiency is very low because it requires a lot of time and manpower. So this study developed a insulating defense tube and pipe connecting device, and a truss structure fabrication module using steel pipe which reduces construction time and cost through a compressive and dielectric strength test.

  • PDF

Crack-healing and durability performance of self-healing concrete with microbial admixture (미생물 혼입 자기치유 콘크리트의 균열 치유성능 및 내구성능)

  • Chu, Inyeop;Woo, Sang-Kyun;Lee, Byung-Jae;Lee, Yun;Lee, Hyo-Sub
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.295-299
    • /
    • 2021
  • Recently, interest in maintenance has been increasing due to the enlargement and aging of infra structures. Therefore, a new paradigm is required to secure and improve the durability of structures differentiated from the past. Accordingly, research on smart concrete incorporating the concept of self-healing into concrete is being actively conducted. In this study, the crack healing performance and durability performance of self-healing concrete applied with a hydrogel containing biomineral-forming microorganisms were evaluated. As a result of evaluating the dispersion of the hydrogel in concrete, it was confirmed that the hydrogel was well distributed in concrete matrix with a dispersion coefficient of 0.35 to 0.46. The crack healing performance evaluation was verified by a water permeability test, and showed a recovery rate of 95% or more at the age of 28 days, confirming the applicability of self-healing concrete. The durability performance of self-healing concrete was evaluated in terms of resistance to penetration of chloride ion and freezing and thawing. Regardless of the mixing of the hydrogel, the same level of durability performance was shown for various compressive strength level. Therefore, it was confirmed that the microbial admixture did not affect concrete durability. In the future, long-term crack healing performance and durability verification studies should be supplemented.

The Proposal of Debrisflow Investigation(II) (토석류 재해조사법의 제안(II))

  • Jung, Jin-Young;Chang, Buhm-Soo;Lee, Wang-Gon;Shinn, Chang-Gun;Park, Cheol-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1366-1375
    • /
    • 2010
  • The damage by Debrisflow is occurring repeatedly recently by influences of abnormal climate changes. To reduce damage of Debris flow, primarily establishes the suitable measures and apply, in order to do that it is important for investigate the actual condition of Debrisflow. However, it is difficult to understand the current situation of Debrisflow phenomenon because the limit of technical development. For the reduce damage by future Debrisflow, have to collect data, analysis and preservation base on real status of Debrisflow disasters. This paper will refer to The Proposal of Debrisflow Investigation development have been applied overseas to the The Proposal of Debrisflow Investigation which already proposed it at these papers with bases. And this paper will suggest currently face objective The Proposal of Debrisflow Investigation to be able to do utilization to a Debrisflow occurrence situation and state and further study analysis(2).

  • PDF

A Study on the Low Frequency Oscillation Using PMU Measurement Data (PMU 데이터를 이용한 저주파 진동분석 연구)

  • Kim, Yonghak;Nam, Suchul;Ko, Baekkyeong;Kang, Sungbum;Shim, Kwansik
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • It is very important to evaluate on/off-line stability to operate the power system stably and economically. Until now, we have continuously secured the operation reliability of the power system through the evaluation of transient, voltage and small signal stability. This paper proposes that it is possible to operate in KWAMS by applying the multi-section analysis and subspace methods and verifying the reliability of the algorithms to directly estimate the dominant oscillation mode of the power system from the signal waveform acquired from the phasor measurement units. In addition, this paper shows that the dominant oscillation mode can be detected from real-time measurement data in power systems. Therefore, if we can monitor the state of the power system in real time, it is possible to avoid a large-scale power outage by knowing the possibility of the power system accident in advance.

A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis (가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구)

  • Ah-Reum, Kim;Byeong Sub, Kwak;Tae-Hyun, Jun;Hyun-joo, Park
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

TECHNICAL PROPOSAL BASED COST REDUCTION BIDDING SYSTEM FOR SUPPLYING AFFODABLE HOUSING

  • Seunghee Kang;Jeongseok Lee;Gunhee Cho;Jeongrak Sohn;Jongdae Bang
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1433-1439
    • /
    • 2009
  • Best value is the ultimate goal of the owner and can thus have diverse meanings according to the project characteristic, owner's purpose, user groups' payment capability, etc.. Recently, resettlement problems of the marginalized members in the urban regeneration area have been issued in Korea because they have no capability to purchase (or lease) redeveloped housing (or apartment). It means that a minimized production cost for reducing supply price of housing is a key factor in establishing the best value of the marginalized members. The lowest-price bidding system serves the purpose of ensuring a minimized production cost, but due to the low-cost investments, it creates various problems, such as sloppy construction, lowered quality, an increased LCC, and worsening profitability for builders. Thus, to help them resettle, it is necessary to supply affordable housing geared towards a certain appropriate quality and minimum construction costs. Towards this end, this study aimed to propose a cost reduction bidding system based on a technical proposal. The proposed technical-proposal-based cost reduction bidding system consists of the following components: work-unit-based, project-unit-based, and construction-period-reducing technical proposals. These components are evaluated to select the best bidder for a given project. The technical proposal based cost reduction bidding system proposed herein is expected to provide facilities with appropriate supply prices and appropriate quality levels, to bolster the technological competitiveness of builders.

  • PDF