• Title/Summary/Keyword: IT Convergence technology

Search Result 8,334, Processing Time 0.044 seconds

Identifying Risk Management Locations for Synthetic Natural Gas Plant Using Pipe Stress Analysis and Finite Element Analysis (배관응력해석 및 유한요소해석에 의한 SNG플랜트의 리스크 관리 위치 선정)

  • Erten, Deniz Taygun;Yu, Jong Min;Yoon, Kee Bong;Kim, Ji Yoon
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.1-11
    • /
    • 2017
  • While they are becoming more viable, synthetic natural gas (SNG) plants, with their high temperatures and pressures, are still heavily dependent on advancements in the state-of-the-art technologies. However, most of the current work in the literature is focused on optimizing chemical processes and process variables, with little work being done on relevant mechanical damage and maintenance engineering. In this study, a combination of pipe system stress analysis and detailed local stress analysis was implemented to prioritize the inspection locations for main pipes of SNG plant in accordance to ASME B31.3. A pipe system stress analysis was conducted for pre-selecting critical locations by considering design condition and actual operating conditions such as heat-up and cool-down. Identified critical locations were further analyzed using a finite element method to locate specific high-stress points. Resultant stress values met ASME B31.3 code standards for the gasification reactor and lower transition piece (bend Y in Fig.1); however, it is recommended that the vertical displacement of bend Y be restricted more. The results presented here provide valuable information for future risk based maintenance inspection and further safe operation considerations.

PSO-Based PID Controller for AVR Systems Concerned with Design Specification (설계사양을 고려한 AVR 시스템의 PSO 기반 PID 제어기)

  • Lee, Yun-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.330-338
    • /
    • 2018
  • The proportional-integral-derivative(PID) controller has been widely used in the industry because of its robust performance and simple structure in a wide range of operating conditions. However, the AVR(Automatic Voltage Regulator) as a control system is not robust to variations of the power system parameters. Therefore, it is necessary to use PID controller to increase the stability and performance of the AVR system. In this paper, a novel design method for determining the optimal PID controller parameters of an AVR system using the particle swarm optimization(PSO) algorithm is presented. The proposed approach has superior features, including easy implementation, stable convergence characteristic and good computational efficiency. In order to assist estimating the performance of the proposed PSO-PID controller, a new performance criterion function is also defined. This evaluation function is intended to reflect when the maximum percentage overshoot, the settling time are given as design specifications. The ITAE evaluation function should impose a penalty if the design specifications are violated, so that the PSO algorithm satisfies the specifications when searching for the PID controller parameter. Finally, through the computer simulations, the proposed PSO-PID controller not only satisfies the given design specifications for the terminal voltage step response, but also shows better control performance than other similar recent studies.

A Study on Continuous long-term Wave Observation using Remote Monitoring System (원격모니터링을 이용한 연속파랑관측에 관한 연구)

  • Shin, Bumshick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.654-659
    • /
    • 2018
  • In this study, continuous long-term observation is implemented with an ocean radar. Ocean radar conducts remote observation (combined) with ground-based radars, which enable a series of simultaneous observations of an extensive range of the coast with high frequency. An ocean radar for continuous long-term observation is operated at Samcheok on the east coast of Korea. Samcheok experienced tsunami damage in recent years and is the location of a nuclear power plant. In order to examine the reliability of the ocean radar, a pressure-type wave gauge, ultrasonic wave gauge, and ocean buoy are installed for the purpose of data comparison and verification. The ocean radar used in this study is an array-type HF-RADAR named WERA (WavE RAdar). The analysis of the data obtained from continuous long-term observations showed that the radar observations were in agreement with more than 90% of the wave data collected within a 25 km range from the center of two sites. Less than 1% of the entire observation data was unmeasured by the time series analysis. As a result of comparing the radar data with the direct observations made by the wave gauge, it was inferred that the RMS deviation is less than 20cm and the correlation coefficient was in the range of 0.84 ~ 0.87. Moreover, supported by such observations, a comprehensive monitoring system is being developed to provide the public with real-time reports on waves and currents via the internet.

Study of the Tidal Currents in Sea Areas around Gyeong-In Waterway (경인아라뱃길 주변해역의 해수유동에 관한 연구)

  • Baek, Seung Hwa;Shin, Bum-Shick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5826-5834
    • /
    • 2014
  • This paper examined the changes in flow patterns due to a blockage of tidal currents in the sea areas between Incheon North Port and Yeomha Channel when it would be influenced by the construction of the Incheon North Port Yeongjongdo dredged soil dumping ground and Incheon Bay tidal power plant. The numerical simulation was performed for three cases: before and after constructing the Incheon North Port Yeongjongdo dredged soil dumping ground and after the construction of the sea-dyke on the east side of the Incheon Bay tidal power plant. The simulation results showed that the tidal directions and currents velocity were similar before and after the construction of the Yeongjongdo dredged soil dumping ground. After the construction of the East Sea-dyke of Incheon tide power plant, however, the tidal currents patterns changed significantly due to flow blockage toward Gyeonggi Bay. The main flow was formed in the north-south direction, and the tidal currents velocity increased slightly on the downstream areas (A,B,C) of Hodo, which is the entrance of the Ara Waterway. The tidal currents at the mouth(D) of Yeomha Channel decreased significantly. The tidal currents of the west side of Se-eodo and the east side of the sea-dyke were rotary currents. The results of this study will provide basic data for the environmental impact assessment and the operation of the Gyeongin Ara Waterway.

Natural Zeolite and Sand Capping Treatment for Interrupting the Release of Cd, Cr, Cu, and Zn from Marine Contaminated Sediment and Stabilizing the Heavy Metals (오염된 해양퇴적물 내 Cd, Cr, Cu, Zn의 용출차단과 안정화를 위한 천연 제올라이트와 모래 피복의 적용)

  • Kang, Ku;Kim, Young-Kee;Park, Seong-Jik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.3
    • /
    • pp.135-143
    • /
    • 2016
  • We investigated the effectiveness of natural zeolite (NZ) and sand (SD) as a capping material to block the release of heavy metals (Cd, Cr, Cu, and Zn) from heavily contaminated marine sediments and stabilize these heavy metals in the sediments. The efficiency of NZ and SD for blocking trace metals was evaluated in a flat flow tank attached with an impeller to generate wave. 0, 10, 30, and 50 mm depth of NZ or SD were capped on the contaminated marine sediments and the metal concentration in seawater was monitored. After completion of flow tank experiments, sequential extractions of the metals in the sediment below the capping material were performed. The difference of pH, EC, and DO concentration between uncapped and capped condition was not significant. The release of cations including Cd, Cu, and Zn were effectively blocked by NZ and SD capping but the interruption of Cr release was observed only in 50 mm depth of SD capped condition. However, the stabilization of Cr in 50 mm depth of SD capped condition was not achieved when compared to uncapped condition. NZ and SD capping were effective for stabilizing Cd, Cu, and Zn in marine sediments. It is concluded that the use of NZ with SD as a capping material is recommended for blocking Cd, Cr, Cu, and Zn release and stabilizing them in contaminated marine sediments.

Numerical Analysis of Resin Filling Process for a Molded Dry-type Potential Transformer (몰드형 건식 계기용 변압기 제작을 위한 수지 충진 해석 연구)

  • Kim, Moosun;Jang, Dong Uk;Kim, Seung Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.511-517
    • /
    • 2016
  • Current oil-type potential transformers for trains are filled with insulating oil, which could have problems like explosions due to rising inner pressure during train operation. Therefore, mold and dry-type potential transformers are being developed to prevent explosions. One problem in manufacturing mold-type transformers is preventing void formation around the coiled core inside the mold during epoxy filling, which could cause an electrical spark. Micro voids can remain in the resin after filling, and macro voids can occur due to the structure shape. A transformer that is being developed has a cavity at the junction of the core and the coil for better performance, and when highly viscous epoxy flows inside the cavity channel, macro voids can form inside it. Therefore, in this study, the free-surface flow of the mold filling procedure was analyzed numerically by applying the VOF method. The results were used to understand the phenomena of void formation inside the cavity and to modify the process conditions to reduce voids.

An Economic Ripple Effect Analysis of Domestic Supercomputing Modeling and Simulation (슈퍼컴퓨팅 모델링 및 시뮬레이션의 산업연관분석 기반 경제적 파급효과 분석)

  • Kim, Myungil;Park, Sung-Uk;Kim, Jaesung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.340-347
    • /
    • 2016
  • Since the 1970s, manufacturing has been one of the key driving forces that has led to Korea's economic growth. However, this growth rate has been reduced significantly since the 2000s, and shows that revenues and employment are steadily decreasing. In addition, while manufacturing investment in Korea has dropped sharply, the United States, Germany, Japan, and other major countries have increased investment in manufacturing. These countries have promoted manufacturing innovation strategies that include the convergence of information and communications technologies (ICT) and manufacturing. For manufacturing innovation, it is important for time and cost savings required for product development to be achieved by changes in the production process, especially product design. Modeling and simulation (M&S) is a process that replaces physical product design, mockup making, and testing, with virtual product creation (modeling) and engineering analysis (simulation). In this paper, we analyze the economic ripple effect of supercomputing M&S using an input-output model technique based on the input-output tables published by the Bank of Korea. When we set the M&S budget (about US$16 million for the last 10 years) of the Korea Institute of Science and Technology Information (KISTI) as input coefficients, the effect on production inducement, value-added inducement, and employment inducement was analyzed to be US$24 million, US$13.4 million, and 267, respectively.

The implementation of cable path and overfill visualization based on cable occupancy rate in the Shipbuilding CAD (조선 CAD에서 선박의 Cable 점유율을 기반으로 Cable 경로 및 Overfill 가시화 구현)

  • Kim, Hyeon-Jae;Kim, Bong-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.740-745
    • /
    • 2016
  • Cables are installed for tens of thousands of connections between various pieces of equipment to operate and control a commercial ship. The correct shortest-route data is necessary since these are complicated cable installations. Therefore, an overfill interval commonly exists in the shortest paths for cables as estimated by Dijkstra's algorithm, even if this algorithm is generally used. It is difficult for an electrical engineer to find the overfill interval in 3D cable models because the occupancy rate data exist in a data sheet unlinked to three-dimensional (3D) computer-aided design (CAD). The purpose of this study is to suggest a visualization method that displays the cable path and overfill interval in 3D CAD. This method also provides various color visualizations for different overfill ranges to easily determine the overfill interval. This method can reduce cable-installation man-hours from 7,000 to 5,600 thanks to a decreased re-installation rate, because the cable length calculation's accuracy is raised through fast and accurate reviews based on 3D cable visualization. As a result, material costs can also be reduced.

Trigeminocardiac Reflex Induced by Electrohemostasis during Total Ear Canal Ablation in a Dog (개의 전이도적출술 중 전기지혈에 의해 발생한 삼차신경심장반사 1례)

  • Jo, Sang-min;Son, Won-gyun;Jang, Min;Kim, Wan Hee;Lee, Byung-Cheon;Lee, Inhyung
    • Journal of Veterinary Clinics
    • /
    • v.33 no.4
    • /
    • pp.234-236
    • /
    • 2016
  • A 14 kg, 9-year-old, spayed female, Cocker Spaniel was presented to the Veterinary Medical Teaching Hospital of Seoul National University with a history of head tilt and circling. Otitis externa and media were diagnosed by computerized tomography, and total ear canal ablation was performed. In preanesthetic evaluation, systemic hypertension and second-degree atrioventricular block were observed, but there was no regurgitation through the heart valves. Systemic hypertension was managed with amlodipine (0.1 mg/kg, PO, BID) for the anesthesia. The dog was premedicated with cefazolin (22 mg/kg, IV) and midazolam (0.2 mg/kg, IV). Anesthesia was induced with alfaxalone (2 mg/kg, IV) and maintained with isoflurane and 100% oxygen following intubation. During surgery, vital signs (heart rate, respiratory rate, blood pressure, end tidal carbon dioxide partial pressure and body temperature) were maintained within normal ranges, but bradycardia was observed and corrected with glycopyrrolate (5 ug/kg IV, twice). During subcuticular suture, electrohemostasis was applied at the incision line, which was close to the trigeminal nerve. In no time at all, heart rate dramatically decreased from 110 to 60 beats per minute. No additional treatment was done because mean blood pressure was maintained above 70 mmHg. The heart rate recovered according to the decrease of end tidal isoflurane concentration and there were no complications associated with the anesthesia and surgery. Sudden bradycardia after electrical stimulation around the trigeminal nerve was considered as trigeminocardiac reflex (TCR). It is recommended to be careful of bradycardia from TCR when electrocautery is used in the craniofacial area during surgery.

Study on the Analysis of Corneal Variation by Refractive Error (굴절이상에 의한 각막 변화도 분석에 관한 연구)

  • Lee, Hae-Jung;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.485-490
    • /
    • 2014
  • The purpose of this Study investigated corneal power, corneal astigmatism and corneal axis according to spherical equivalent of refractive error. We measured spherical equivalent, corneal power and corneal astigmatism in 100 subjects from January 2014 to July 2014. Measured spherical equivalent of refractive error were $-3.01{\pm}3.79D$, corneal power of $43.79{\pm}1.60D$ and corneal astigmatism of $-1.17{\pm}0.79D$ respectively. Prevalence of spherical equivalent of refractive error were as follows : myopes (61%), emmetropes (22%), hyperopes(17%). Corneal astigmatism of refractive error greater than +0.75D was 63% and prevalence of corneal astigmatism were as follows : with-the-rlue astigmatism (84.13%), against-the-rule astigmatism(9.52%) respectively. Corneal power by spherical equivalent increased from hyperopia to myopia. Between spherical equivalent of refractive error and the mean corneal power was significant correlation(r=-0.25, p=0.01). A correlation were found between corneal power and spherical equivalent of refractive error in adults. They have the highest distribution of prevalence myopia among the refractive error. When the refractive error was increased, we found that corneal power was steeper. It is recognized that this can be refractive error factor and correct visual function is considered.