• Title/Summary/Keyword: ISR

Search Result 561, Processing Time 0.043 seconds

A Study on the Reflection of Condition-Based Maintenance Requirement in the Defense Specification (상태기반정비 요구도 국방규격 반영에 관한 연구)

  • Son, Minjeong;Kim, Young-Gil
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.3
    • /
    • pp.269-279
    • /
    • 2021
  • Purpose: The purpose of this study was to suggest weapon system specifications for requirements of Condition-Based Maintenance(CBM/CBM+). Methods: The military documents and case studies with regard to condition-based maintenance were reviewed. Representative Korea defense specifications of weapon system such as an aircraft, a C4ISR etc. were analyzed and investigated the level of requirement for maintainability was. Results: Condition-based maintenance was defined in both U.S. instruction and Korean directive. While deparment of defense(U.S.) provide a guidebook for CBM+, detailed instruction was not sufficient for Korean. Ministry of national defense(ROK) define the CBM+ by means of IPS element which should be developed along with the system development. The maintainability was barely included in Korean defense specifications, except for BIT(Built-in test) function. As a first step for defining the condition-based maintenance requirement in defense specification, this study suggests a standard form for data needed to acquire according to types of system, fault, failure, and so on. Conclusion: The empirical researches on CMB/CBM+ with domestic weapon systems are not enough, and a logic which leads the maintenance strategy to CMB/CBM+ is not solved. Through technical researches and institutional improvements including this study, we hope that condition-based maintenance would be fully established in the Korean defense field.

Proposing a Preferred Parts List and Developing a Search System for Common Parts (우선부품목록 선정방안 제시 및 공용화 검색 시스템 구축)

  • Yoon, Jaebok;Kim, Siok;Moon, Jinkyu;Hong, Sungmin;Lim, Hojung;Kim, Sanghan
    • Journal of Korean Society for Quality Management
    • /
    • v.48 no.4
    • /
    • pp.567-580
    • /
    • 2020
  • Purpose: The purpose of this study is to present a preferred parts list, establish a search tool for common parts, and propose a development plan for parts management. Methods: When selecting the preferred parts list, the weight of the selection of the military parts and the online site of the civilian parts were taken into account. By establishing a database of selected preferred parts list, we have established a system for searching common parts. Results: The results of this study are as follows; In order to establish parts management work in Korea's defense, it is necessary to improve the Defense Acquisition Program Act, Enforcement Decree (Rules), and the Regulations for Defense Acquisition Program Administration. Development of performance indicators for parts management is required, and establishment of procedures and standards for selection of preferred parts lists is required. Considerations for the selection of preferred parts list include whether they are used a lot in civilian products, whether they are used a lot, whether they are certified suppliers, whether they are national and industrial standard products, whether they perform well considering reliability, durability, and quality, and whether they can be supplied continuously. Conclusion: It is necessary to establish policies and systems related to parts management and to establish criteria for selecting preferred parts list for the development of domestic parts management tasks.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

A Study on the Effect of Atmosphere on the Space Surveillance Radar (우주감시레이다에 대한 지구 대기권 영향 분석 연구)

  • Moon, Hyun-Wook;Choi, Eun-Jung;Lee, Jonghyun;Yeum, Jaemeung;Kwon, Sewoong;Hong, Sungmin;Cho, Sungki;Park, Jang-Hyun;Jo, Jung Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.8
    • /
    • pp.648-659
    • /
    • 2018
  • In this study, both the altitude error due to the refraction and the range error due to the delay in the ionosphere with respect to the frequency are extracted according to the radar elevation to analyze the effect of atmosphere on the space surveillance radar. To achieve this, the radio refractivity profile is modeled using the measured data from domestic weather stations. Then, the altitude-error due to the refraction is extracted using the ray tracing method, and the range error in the ionosphere is extracted according to the frequency. Further, considerations for radar design with respect to the radar error characteristics are discussed based on the abroad space surveillance radar and proposed domestic space surveillance radar. This analysis of the error characteristics is expected to be utilized for the determination of radar location, range of steering, and frequency in the space surveillance radar design.

Comparison of Performance Between Incremental and Batch Learning Method for Information Analysis of Cyber Surveillance and Reconnaissance (사이버 감시정찰의 정보 분석에 적용되는 점진적 학습 방법과 일괄 학습 방법의 성능 비교)

  • Shin, Gyeong-Il;Yooun, Hosang;Shin, DongIl;Shin, DongKyoo
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.3
    • /
    • pp.99-106
    • /
    • 2018
  • In the process of acquiring information through the cyber ISR (Intelligence Surveillance Reconnaissance) and research into the agent to help decision-making, periodic communication between the C&C (Command and Control) server and the agent may not be possible. In this case, we have studied how to effectively surveillance and reconnaissance. Due to the network configuration, agents planted on infiltrated computers can not communicate seamlessly with C&C servers. In this case, the agent continues to collect data continuously, and in order to analyze the collected data within a short time in When communication is possible with the C&C server, it can utilize limited resources and time to continue its mission without being discovered. This research shows the superiority of incremental learning method over batch method through experiments. At an experiment with the restricted memory of 500 mega bytes, incremental learning method shows 10 times decrease in learning time. But at an experiment with the reuse of incorrectly classified data, the required time for relearn takes twice more.

Relationship between Plant Protection Rate and Coefficient of Variation of Microbial Products for Ginseng Cultivation (인삼재배용 미생물 제품의 식물보호율과 변이계수와의 관계)

  • Lee, Byung-Dae;Park, Hoon
    • Journal of Ginseng Research
    • /
    • v.33 no.2
    • /
    • pp.127-131
    • /
    • 2009
  • The plant protection rate of the marketed microbial products for ginseng cultivation was investigated against Rhizoctoina solani and Pythium sp. in a seedling pot experiment. A significant difference was found among the mean plant protection rates (Pm) of the microbial products, including Tolclofos-methyl (Rhizolex). The best microbial product, C-ISR2, showed a 33% and 33.6% net Pm (total Pm-control Pm) in the two tests against Rhizoctonia solani. In one test with a 58.6% control plot Pm, the total pm was 91.6%, indicating that plant protection can be done only with a microbial product in a well-conditioned field. The net Pm of C-ISR2 against Pythium sp. was 26.4%. The net Pm of a microbial product against a pathogen seems to be fixed. A significant negative linear correlation was found between the Pm and the coefficient of variation (CV) of the protection rate in all the three experiments. This indicates that the protection processes of control, microbial products, and chemical pesticides are in the same system. Pm was only dependent on CV, probably due to each seedling's microenvironment. In the linear correlation equation between the Pm and the CV of the microbial products and the control plot, the intercept of the vertical axis will be the theoretical Pm when CV is zero.

The Study on the Independent Predictive Factor of Restenosis after Percutaneous Coronary Intervention used Drug-Eluting Stent : Case on MDCT Calcium-Scoring Implementation Patient (약물용출 스텐트를 이용한 관상동맥중재술 후 재협착의 독립적 예측인자에 관한 연구 : MDCT calcium-scoring 시행 환자 대상으로)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo;Jang, Young-Ill
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.37-44
    • /
    • 2010
  • We sought to confirm an independent factor about in-stent restenosis (ISR) in the patients who underwent drug-eluting stent (DES) and know a possibility as a predictor of measured coronary artery calcium score by MDCT. A total of 178 patients (159 men, $61.7{\pm}10.0$ years of age) with 190 coronary artery lesions were included in this study out of 1,131 patients who underwent percutaneous coronary intervention (PCI) with DES implantation for significant stenosis on MDCT at Chonnam National University Hospital between May 2006 and May 2009. All lesions were divided into two groups with the presence of ISR : group I (re ISR, N = 57) and group II (no ISR, N = 133). Compared to group II, group I was more likely to be older ($65.8{\pm}9.0$ vs. $60.2{\pm}9.9$ years, p = 0.0001), diabetic (21.8% vs. 52.6%, p = 0.0001), have old myocardial infarction (8.8% vs. 2.3%, p = 0.040), left main stem disease (5.3% vs. 0.8%, p = 0.047), and smaller stent size ($3.1{\pm}0.3\;mm$ vs. $3.3{\pm}0.4\;mm$, p = 0.004). Group II was more likely to be smokers (19.3% vs. 42.1%, p = 0.003), have dyslipidemia (8.8% vs. 23.3%, p = 0.019). Left ventricular ejection fraction, lesion complexity, and stent length were not different between the two groups. Total CAC score was $389.3{\pm}458.3$ in group I and $371.2{\pm}500.8$ in group II (p = 0.185). No statistical difference was observed between the groups in CAC score in the culprit vessel, left main stem, left anterior descending artery, left circumflex artery, and right coronary artery. On multivariate logistic regression analysis, left main stem disease (OR = 168.0, 95% CI = 7.83-3,604.3, p = 0.001), male sex (OR = 36.5, 95% CI = 5.89-2,226.9, p = 0.0001), and the presence of diabetes (OR = 2.62, 95% CI = 1.071-6.450, p = 0.035) were independent predictors of ISR after DES implantation. In patients who underwent DES implantation for significant coronary stenosis on MDCT, ISR was associated with left main stem disease, male sex, and the presence of diabetes. However, CAC score by MDCT was not a predictor of ISR in this study population.

Design of AEM FSS-Radome for Array Antenna (배열 안테나용 AEM형 FSS 레이돔 설계)

  • Kim, Sang-Keun;Lee, Gi-Tae;Seo, Il-Seong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1180-1183
    • /
    • 2011
  • In this paper, we present a design of AEM radome with frequency selective surface using unit-cell EM simulation method and verified the performance of AEM radome by the radiation pattern measurements of $16{\times}16$ array-antenna. Measured results under near-field condition showed a good agreement with the simulation and far-field measured ones. And there were no radiation pattern variation between antenna only and antenna with AEM radome. From these results, we verified that AEM radome with frequency selective surface can be a solution to reduce the RCS of conventional mast and radar.