• 제목/요약/키워드: ISO 17025

검색결과 34건 처리시간 0.016초

곡관의 하류에 설치된 전자기유량계의 유량신호 특성에 관한 실험적 연구(난류 유동) (An Experimental Study on Installation Effects of Pipe Elbow on the Electromagnetic Flowmeter Characteristics (Turbulent Flow))

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1613-1621
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) essentially averages the velocity distribution over the pipe cross- sectional area, and the measured value is dependent on the velocity profiles. In this study, installation effects of 90$^{\circ}$long elbow(KS B 1522, ISO 3419) on the EMF characteristics was investigated. A commercial EMF was adopted and the distribution of magnetic field in the electrodes cross section was measured. In the experiment, the national flow standard system, of which measurement uncertainty was evaluated in accordance with ISO 17025 recommendation, was used fur characterization of EMF. The leading line has 150D long straight pipe to established a fully developed flow before entering into the elbow and the elbow was installed downstream of it. then the flowmeter was tested within 50 D from the elbow. The installation effects of the flowmeter were investigated by varying the mean velocity(Reynolds No.)in pipe section, the locations and the direction of electrodes plane.($\phi$) From the experimental results, we find the optimal conditions to get most accurate measurements. Generally, the deviations from the calibration value were less than 0.5 % in farther than 10D distance from the elbow and the direction of electrode plane. $\phi$ = 90$^{\circ}$yielded the smallest measurement deviation. These characteristics were shown consistently in turbulent region regardless of the mean Reynolds number.

메디컬시험기관에서 ISO 15189 도입의 필요성과 시행의 효용성 (Adoption and Efficacy of ISO 15189 in Medical Laboratories for Diagnostic and Research)

  • 양만길;이원호;전진현
    • 대한임상검사과학회지
    • /
    • 제48권2호
    • /
    • pp.158-167
    • /
    • 2016
  • 다양한 분야에 대한 품질표준들 중에서 메디컬시험기관에 대한 품질 및 적격성에 대한 요구사항인 ISO 15189는 ISO 9001; 품질경영시스템-요구사항과 ISO/IEC 17025; 시험기관 및 교정기관의 능력에 관한 일반요구사항인 두 표준을 바탕으로 메디컬시험기관에 요구되는 사항들을 충족하도록 제정되어 있다. 이 ISO 15189에서는 메디컬시험기관 검사에 관여하는 실무자의 자격 및 지속적인 역량, 시험기관 규모, 장비, 시약 및 소모품, 분석전 및 분석인자, 품질보증을 위한 고려사항 및 분석 후 인자 등이 기술되어 있다. 인정과정에서는 업무와 관련된 범주에 전문성을 갖춘 전문가 및 임상평가사들은 다음의 사항을 포함하여 시험데이터 산출에 영향을 미치는 시험기관에서의 모든 요인에 대한 철저한 평가를 수행한다. 메디컬시험기관의 품질경영시스템은 임상의 또는 환자의 니즈 및 요구사항을 충족시켜야 한다. 품질경영시스템을 기획할 때는 요구사항을 준수하고 품질목표를 충족시켜야 하며 변경하고자 하는 경우에는 품질경영시스템의 통합성을 유지시켜야 한다. 품질경영시스템의 통합성은 목표 달성을 위한 세부 요소들의 상호작용 즉, Plan-Do-Check-Act (P-D-C-A) cycle이 서로 유기적으로 작용하여 지속적인 개선(improvement)이 이루어짐을 의미한다. 메디컬시험기관 ISO 15189 인정제도는 법률 또는 국제기준에 적합한 인정기구가 전문적인 자격을 갖춘 평가사로 하여금 메디컬시험기관의 품질 시스템과 기술능력을 평가하도록 하여 메디컬시험분야에 대한 시험능력이 있다는 것을 공식적으로 인정하는 제도로 우리나라에서는 한국인정기구(KOLAS)가 담당하고 있다. 정부의 2010년 무렵의 KS P ISO 15189 도입 계획은 다소 지연되어, 2016년 4월 1일 기준으로 한국인정기구(KOLAS)를 통해 인정 받은 메디컬시험기관은 공공기관 2곳(한국원자력의학원 생물학적선량 평가실, 서울대학교병원 핵의학과)과 민간기관이 3곳(삼성서울병원 핵의학과, 서울아산병원 핵의학과, 서울아산병원 병리과)뿐이지만, ISO 15189 도입의 궁극적인 목적인 메디컬 서비스의 질적 수준의 향상과 국제적인 경쟁력 강화에 대한 사회적인 요구를 반영하기 위해, 각 기관에서는 적극적인 자세로 도입에 노력해야 할 것으로 생각된다.

국내석면조사기관의 질적 수준 평가를 위한 현황조사 (A Study for Qualitative Performance of Asbestos Inspection/Analysis Labs in Korea)

  • 최성원;권지운;백정은;장광명;김대종;김현욱
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.501-508
    • /
    • 2014
  • Objectives: This study identified the general characteristics of asbestos inspection/analysis laboratories in Korea and confirmed the actual situations in terms of technical aspects from these characteristics. In addition, given the background of the current problem, it offers preliminary data for determining future plans for improvement. Methods: A questionnaire was developed and distributed to the asbestos inspection/analysis laboratories that used the ISO/IEC 17025 for asbestos sampling and testing by UKAS(United Kingdom Accreditation Service) and the Korea Laboratory Accreditation Scheme(KOLAS). A total of 202 institutions in Korea were selected for the study and 145(71.8%) questionnaires were returned. Results: The number of personnel of the surveyed institutions averaged $4.2{\pm}2$ and 79.3% operated with less than five persons. In terms of education, the capital and other densely populated areas showed a high level of education(p<0.05). The level of education and facilities were determined by the magnitude of the institution(p<0.05). Institutions managed by highly educated directors were well-stocked with education and facilities(p<0.05). Institutions which had directors with considerable experiences received high scores overall and in particular higher scores in terms of education and facilities(p<0.05). At the level of the bottom five percent, the factor of education was 40.4% while the factor of measurement 49%, the factor of analysis 59%, the factor of facilities 61%, and the factor of survey 81%, respectively. Conclusions: To improve the quality of the institutions, in the short term, the problems identified in this study can be used to revise the related regulations. In the long term, a grading system of survey institutions needs to be established through the introduction of an accreditation system. However, the ongoing support of a government agency is required, including holding seminars and open education, suggesting guidelines for operation of asbestos inspection/analysis labs, and other means.

개인피폭선량 측정기관의 품질관리기준 개발 (Quality Control of Radiation Dosimetry Service)

  • 이준행;이상복;장근조;이광용;이현구;김혁주;진계환
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.253-259
    • /
    • 2009
  • 방사선관계종사자에 대한 개인피폭선량 측정의 정확성 및 신뢰성을 확보함으로써 방사선관계종사자의 건강을 보호하고 국민보건 수준향상에 기여하기 위한 개인피폭선량 측정기관의 선량측정 품질관리 기준을 국제기준에 적합하도록 개발할 필요성이 제기되고 있다. 국내 의료기관에서의 개인선량 관련법은 ANSI N13.11-1993 규정을 참조하고 있으나 미국을 비롯한 해외 여러 나라에서는 시험 범주를 줄이고 기준을 강화한 ANSI N13.11-2001을 이미 반영하여 개인피폭선량을 측정하고 있다. 제안하는 방법은 ANSI N13.11-2001을 참고하여 기준을 단순화하였고 유리선량계와 광자극선량계 같은 현재 법률에서 인정하지 않는 첨단기술을 이용하는 것을 막거나 방해할 수 있는 조치를 취하지 않으려고 하였다. 본 논문에서 제안하는 측정기관 품질관리기준은 개인피폭선량 성능시험기준은 관련법규개정에 참고할 수 있고, 측정기관 지도 감독에 활용할 수 있다.

  • PDF