• Title/Summary/Keyword: ISO : International Standardization Organization

Search Result 179, Processing Time 0.026 seconds

Development of a General Occupational Safety and Health (OSH) Guide for Maintenance Work at Electronics Industry Processing Facilities (전자산업 공정 설비 작업 안전보건가이드 개발)

  • Soyeon Kim;Seunghee Lee;Jeongyeon Park;Taek-hyeon Han;Jae-jin Moon;Ingyun Jung;Kyung Ehi Zoh;Seyoung Kwon;Kwang Jae Chung;Dong-Uk Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.18-25
    • /
    • 2024
  • Objectives: The primary aim of this study is to create an Occupational Safety and Health (OSH) guide for high-risk maintenance tasks, specifically one designed for maintenance work (MW) in the electronics industry. Methods: The methodology involved a literature review, field investigations, and discussions. An initial draft of the OSH guide was created and then refined through consultations with experts possessing extensive experience in MW for electronic processes. Results: Specific MW tasks within electronics processing facilities identified as high-risk by the research were selected. A comprehensive OSH guide for these tasks was developed consisting of approximately 11 to 12 components and encompassing about 20-25 pages. Implementing safety and health measures before, during, and after MW is crucial for the protection of maintenance personnel. The guide is enriched with real-case scenarios of industrial accidents and occupational diseases to enhance maintenance workers' comprehension of the OSH principles. For a clearer understanding of and adherence to the safety protocols, the guide incorporates visual aids, including cartoons and photographs. Conclusions: This OSH guide is designed to ensure the protection of workers involved in maintenance activities in the electronics industry. It aligns with global standards set by the International Organization for Standardization (ISO) and Semiconductor Equipment and Material International (SEMI) to ensure a high level of safety and compliance.

A cluster analysis of the audit result on quality management system in architectural design and engineering firms (설계 및 엔지니어링분야의 품질경영시스템 심사결과에 대한 유형분석)

  • Bae Dae-kwon;Kim Soo-Yoo;Kim Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.2 s.24
    • /
    • pp.120-128
    • /
    • 2005
  • ISO 9001, the quality management system issued by the International Organization for Standardization, is being used by architectural design and engineering firms in order to strengthen the capability of business activities through the implementation of the international and advanced quality management systems. However, there have been significant problems in stable implementation and settlement of ISO 9001 in construction industry, which seem to be caused by key employees' lack of proper recognition and comprehension. The purpose of this research, accordingly, is to find and analyze nonconformity results which were found when the third party registrars audited the conformity of companies' quality management systems for ISO 9001 certification especially in architectural design and engineering firms. For this purpose this research was conducted by a cluster analysis of 647 audit reports out of representative 15 architectural design and engineering firms that have been audited periodically from 1997 to 2003 by the third party registrars. The analysis showed that the most frequent problems were generated in the areas of $\ulcorner$Design and Development$\lrcorner$ , $\ulcorner$production and Service Provision$\lrcorner$ , and $\ulcorner$General requirements$\lrcorner$ of the quality management system. The following, the areas of $\ulcorner$Monitoring and Measurement$\lrcorner$ and $\ulcorner$purchasing$\lrcorner$ were also analyzed as main factors which caused frequent nonconformity results. This research also shows that the corrective actions for nonconformity results are closely connected with the whole management activities in architectural design and engineering firms. Consequently, corrective actions for disposition of nonconformities should be implemented more specifically in order to settle and activate the quality management systems in architectural design and engineering firms.

ECSS E70 Standard for developing common EGSE and MCS (전기지상지원장비 및 관제시스템 통합 개발을 위한 유럽 표준안 현황)

  • Huh, Yun-Goo;Choi, Jong-Yeoun
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.1
    • /
    • pp.56-64
    • /
    • 2008
  • Although the EGSE (Electrical Ground Support Equipment) and MCS (Mission Control System) have many similar or even identical functions, the EGSE used for assembly, integration and validation phase and the MCS for the mission operations phase are normally developed separately and used by different groups of engineers. However, the common ground system for EGSE and MCS has developed and many space missions such as PROBA (PRoject for On-Board Autonomy), ROSETTA, MARS EXPRESS, CRYOSAT (Cryosphere Satellite), GOCE (Gravity field and steady state Ocean Circulation Explorer), and GALILEO have used or will use it to minimize risk, reduce cost and improve overall product quality. It is based on ECSS (European Cooperation for Space Standards) E70 which is the international standard for ground systems and operations published by ECSS E70 Working Group. The ECSS E70 contains the basic rules, principles and requirements applied to the engineering of the ground systems and the execution of mission operations. This paper introduces standardization policy, organization and standard documentation in ECSS. The overview of ECSS E70 such as status, purpose and contents is also described in this paper.

  • PDF

Evaluation of Titanium-nitride Coated Crown: Surface Hardness, Corrosion Resistance and Color Sustainability (타이타늄-질소 코팅된 금속관에 대한 평가: 표면 경도, 부식 저항성, 색조 안정성)

  • Kim, Hyojin;Lim, Sumin;Kim, JinYoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.3
    • /
    • pp.344-351
    • /
    • 2021
  • The purpose of this study was to compare surface hardness between titanium-nitride coated crowns (TiNCs) and stainless steel crowns (SSCs), and to evaluate the corrosion resistance and color sustainability of TiNCs. Ten TiNCs and 10 SSCs were used for the hardness test. Measurement was performed 30 times for each type of crowns, and the mean values were compared. Metallic raw material plates (before being processed into crowns) of TiNCs and SSCs were prepared for the corrosion resistance test. The total amounts of metal ion releases in the test solution were detected by inductively coupled plasma-optical emission spectrometry. Five TiNCs were subjected to the color sustainability test by applying repetitive brushing forces. The mean hardness values of TiNC group and SSC group were 395.53 ± 105.90 Hv and 278.70 ± 31.45 Hv respectively. Hardness of TiNCs were significantly higher than that of SSCs. The total amounts of metal ion releases from the materials of TiNCs and SSCs satisfied the criterion in International Organization for Standardization 22674. The results mean that TiNCs and SSCs were not harmful in an acidic environment. The golden coating was stable against the repetitive physical stimulations for a given period time.

Ergonomic Analysis for the Aging-Friendly Exercise Device Utilized on the Digital Load Control Technology (디지털 중량제어기술을 활용한 고령친화운동기구의 인간공학적 분석)

  • Kim, Bo-Kun;Jang, Young-Kwan;Hah, Chong-Ku;Baek, Jun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.252-260
    • /
    • 2021
  • For frailty management, the importance of resistance exercise has been emphasized, and various devices have been developed. Recently, digital weight control technology that converts electromagnetic resistance to a digital weight is attracting attention, but there are no reports confirming the effectiveness and safety of the device for seniors in Korea. This study conducted a biomechanic-based ergonomic analysis of an elderly-friendly exercise device utilized in digital load control technology to suggest a direction for development. Twenty seniors (age: 62.40 ± 2.09 years) were included. The load of the device was classified into three levels, and the muscle activity and heart rate were assessed during three experimental motions. A questionnaire based on the International Organization for Standardization 9241-11 was adopted to evaluate the stability, operationality, efficiency, and satisfaction with the software and device. The program could be divided into three exercise intensities that can be utilized in the field depending on whether the exercise load, muscle activity, and heart rate were consistent. The monitor size needed to be enlarged to make the menu Korean, reduce the device size, and minimize noise. Considering these findings, the development of an advanced age-friendly exercise device by improving the size, display, and noise is suggested.

Survey of Point-of-Care Testing Devices for Pre-hospital EMS Equipment of Glucometer on Local Area (지역 EMS의 현장검사 혈당측정기 사용에 대한 실태조사)

  • Byeong-Hyun, Kim;Dai-Hai, Choi;Gyoung-Yim, Ha
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.4
    • /
    • pp.220-228
    • /
    • 2022
  • Objective: glucometer is one of POCT(point-of-care testing) devices used by EMS. Accurate measurement value is important for patient decision making. Quality control is necessary for this, but most EMS are still using glucometer without quality control it. Therefore, management status and quality control status of glucometers used by 119 paramedics waswere investigated. Methods: 6 and 8 of glucometers and blood glucose test strips were submitted from 4 safety centers in 2010 and 8 safety centers in 2012, respectively. Glucometers submitted by local safety centers were analyzed in 2010 and 2012. The control glucometer, which was well managed at A University Hospital, was assumed to be accurate for at blood glucose measurement. Glucose values of various quality control materials control solutions were measured and analyzed using linear regression and Pearson's correlation test. Error rates were obtained via error tolerance range required by the 2011 ISO(International Organization for Standardization) guideline. For statistics, Excel and MedCalC programs were used. Results: mong 14 safety centers in the region, 4 centers(28.5%) in 2010 and 8 centers(57.1%) in 2012 submitted 6 and 8 glucometers. In the first evaluation in 2010, 2 out of 6(33.3%) glucometers were untestable due to error, and 45 out of 6(66.683.3%) blood glucose test strips' validity were expired. In the second evaluation in 2012, 1 out of 8(13.5%) glucometers were untestable due to lack of battery, and 2 out of 8(25%) blood glucose test strips' validity were expired. All correlation coefficients were above 0.989 in 2010 and above 0.997 in 2012. Error rates were generally high when using expired blood glucose test strips. Conclusion: Among 119 paramedics' guideline, quantity and operation status of POCT devices are well managed, but quality control is not. Therefore, it is necessary to add management status and quality control status of POCT devices to the EMS' field work guideline.

Comparison and Decision of Exposure Coefficient for Calculation of Snow Load on Greenhouse Structure (온실의 적설하중 산정을 위한 노출계수의 비교 및 결정)

  • Jung, Seung-Hyeon;Yoon, Jae-Sub;Lee, Jong-Won;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.226-234
    • /
    • 2015
  • To provide the data necessary to determine exposure coefficients used for calculating the snow load acting on a greenhouse, we compared the exposure coefficients in the greenhouse structure design standards for various countries. We determined the exposure coefficient for each region and tried to improve on the method used to decide it. Our results are as follows: After comparing the exposure coefficients in the standards of various countries, we could determine that the main factors affecting the exposure coefficient were terrain roughness, wind speed, and whether a windbreak was present. On comparing national standards, the exposure coefficients could be divided into three groups: exposure coefficients of 0.8(0.9) for areas with strong winds, 1.0(1.1) for partially exposed areas, and 1.2 for areas with dense windbreaks. After analyzing the exposure coefficients for 94 areas in South Korea according to the ISO4355 standard, all of the areas had two coefficients (1.0 and 0.8), except Daegwallyeong (0.5) and Yeosu (0.6), which had one coefficient each. In South Korea, the probability of snow is greater inland than in coastal areas and there are fewer days with a maximum wind velocity > $5m{\cdot}s^{-1}$ inland. When determining the exposure coefficients in South Korea, we can subdivide the country into three regions: coastal areas with strong winds have an exposure coefficient of 0.8; inland areas have a coefficient of 1.0; and areas with dense windbreaks have an exposure coefficient of 1.2. Further research that considers the number of days with a wind velocity > $5m{\cdot}s^{-1}$ as the threshold wind speed is needed before we can make specific recommendations for the exposure coefficient for different regions.

Production and Fuel Properties of Wood Chips from Logging Residues by Timber Harvesting Methods (목재수확 방법에 따른 벌채부산물 목재칩의 생산 및 연료 특성)

  • Choi, Yun-Sung;Jeong, In-Seon;Cho, Min-Jae;Mun, Ho-Seong;Oh, Jae-Heun
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.2
    • /
    • pp.217-232
    • /
    • 2021
  • This study calculated the productivity and cost of extraction and processing of logging residues by cut-to-length (CTL) and whole-tree (WT) harvesting methods. In addition, the comparative analysis of the characteristics of wood chip fuel to examine whether it was suitable for the fuel conditions of the energy facility. In the harvesting and processing system to produce the wood chips of logging residues the system productivity and cost of the CTL harvesting system were 1.6 Gwt/SMH and 89,865 won/Gwt, respectively. The productivity and cost of the WT harvesting system were 2.9 Gwt/SMH and 72,974 won/Gwt, respectively. The WT harvesting productivity increased 1.3times while harvesting cost decreased by 18.7% compared to the CTL harvesting system. The logging residues of wood chips were not suitable for CTL wood chips based on International Organization for Standardization (ISO 17225-4:2021) and South Korea standard (NIFoS, 2020), but the quality (A2, Second class) was improved through screening operation. The WT-unscreened wood chips conformed to NIFoS standard (second class) and did not conform to ISO but were improved through screening operation (Second class). In addition to the energy facility in plant A, all wood chips except CTL-unscreened wood chips were available through drying processing. The WT-unscreened wood chips were the lowest at 99,408 won/Gwt. Plants B, C, and D had higher moisture content than plant A, so WT-unscreened wood chips without drying processing were the lowest at 57,204 won/Gwt. Therefore, the production of logging residues should improve with operation methods that improve the quality of wood chips required for applying the variable biomass and energy facility.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.