• Title/Summary/Keyword: ISO : International Standardization Organization

Search Result 179, Processing Time 0.026 seconds

Efficacy of ISO 9001 : 2000 Quality Management System in Human Assisted Reproductive Technology Center (보조생식술 센터에서 ISO 9001 : 2000 품질경영시스템의 도입 및 시행의 효용성)

  • Jun, Jin-Hyun;Park, Yong-Seog;Lee, Hyoung-Song;Kim, Soon-Duk;Hwang, Son-Hee;Han, Su-Kyoung;Kim, Jae-Ho;Song, In-Ok;Kang, Inn-Soo;Koong, Mi-Kyoung
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.34 no.2
    • /
    • pp.107-115
    • /
    • 2007
  • Objective: A quality management system of international standardization organization (ISO) 9001:2000 has been proposed to properly evaluate and improve the quality of productions and services. The purpose of this article was to describe on successful introduction and application of the ISO system to human assisted reproductive technology (ART) center. Methods: Center for reproductive medicine and infertility of Cheil General Hospital started the action for ISO 9001:2000 certification at January-2004. The ISO system of our center was monitored by measuring the customer satisfaction index and periodical internal and external audit. Reports of non-conformity described corrective and preventive actions for problems and occurrences that were not consistent with the standard process and operation of our center. Continuous management and improvement were performed on the project of customer dissatisfaction. Results: Our center has got the certification of ISO 9001:2000 for "Research and development of IVF-ET program for infertility treatment" from Korean Foundation for Quality at June-2004. The policy of ISO was "To establish the best center of reproductive medicine and infertility" and "To establish the best quality management system". We found 140 cases and 7 cases of non-conformity in internal and external audit for three years, respectively, and performed corrective action. Conclusion: Improvement of customer satisfaction, systemic documentation and transparency and efficacy of working procedure were achieved by application and operation of the ISO system to our center. This ISO system could be used as a basic institutional management system for the national guideline to the human ART center.

A Test to Compare the Water Resistance Sun Protection Factor of General Water, Artificial Seawater, and Natural Seawater of Sunscreen (자외선 차단제의 일반 물, 인공 해수, 자연 해수의 내수성 차단지수를 비교하기 위한 시험)

  • Hyoung Hoon Hwang;Eun Young Kang;Su Yeong Kim;Hui Jeong Jung;Jun Seong Yang;Won Kyu Hong;Hong Suk Kim
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.4
    • /
    • pp.349-354
    • /
    • 2023
  • Sunscreen is a product that protects against ultraviolet rays by blocking and scattering ultraviolet rays, and has now become a daily necessity beyond cosmetics. Applying sunscreen is a common and easy way to prevent skin damage caused by ultraviolet rays. Due to its significance, the evaluation of sunscreen has evolved since its regulation by the FDA in 1978, progressing to standardized methods established by ISO. Additionally, to assess the loss of sunscreen due to activities such as water exposure or sweating, the Ministry of Food and Drug Safety in Korea and ISO have established protocols for evaluating the water-resistant sun protection factor (SPF). However, existing evaluations of water resistance have been mainly confined to test methods involving plain water, and methods accounting for the impact of seawater during activities like beach leisure, sports, and recreation are yet to be established. Based on the existing guidelines for testing the water-resistant UV protection index, this study compared the water-resistant UV protection index in water, artificial seawater (salt water) and natural seawater (sea water) to evaluate the UV protection index in real-world situations such as marine leisure, sports, and leisure activities. Through these results, we were able to compare the differences between water resistance sun protection index tests in ordinary water, artificial seawater, and natural seawater, and suggest a method for water resistance sun protection index tests using natural seawater.

Medical Image Compression Using JPEG International Standard (JPEG 표준안을 이용한 의료 영상 압축)

  • Ahn, Chang-Beom;Han, Sang-Woo;Kim, Il-Yoen
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.504-506
    • /
    • 1993
  • The Joint Photographic Experts Group (JPEG) standard was proposed by the International Standardization Organization (ISO/SC 29/WG 10) and the CCITT SG VIII as an international standard for digital continuous-tone still image compression. The JPEG standard has been widely accepted in electronic imaging, computer graphics, and multi-media applications, however, due to the lossy character of the JPEG compression its application in the field of medical imaging has been limited. In this paper, the JPEG standard was applied to a series of head sections of magnetic resonance (MR) images (256 gray levels, $256{\times}256$ size) and its performance was investigated. For this purpose, DCT-based sequential mode of the JPEG standard was implemented using the CL550 compression chip and progressive and lossless coding was implemented by software without additional hardware. From the experiment, it appears that the compression ratio of about 10 to 20 was obtained for the MR images without noticeable distortion. It is also noted that the error signal between the reconstructed image by the JPEG and the original image was nearly random noise without causing any special-pattern-related artifact. Although the coding efficiency of the progressive and hierarchical coding is identical to that of the sequential coding in compression ratio and SNR, it has useful features In fast search of patient Image from huge image data base and in remote diagnosis through slow public communication channel.

  • PDF

Quantitative analysis of the effect of fraction of inspired oxygen on peripheral oxygen saturation in healthy volunteers

  • Kang, Bong Jin;Kim, Myojung;Bang, Ji-Yeon;Lee, Eun-Kyung;Choi, Byung-Moon;Noh, Gyu-Jeong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.2
    • /
    • pp.73-81
    • /
    • 2020
  • Background: The international organization for standardization (ISO) 80601-2-61 dictates that the accuracy of a pulse oximeter should be assessed by a controlled desaturation study. We aimed to characterize the relationship between the fraction of inspired oxygen (FiO2) and peripheral oxygen saturation (SpO2) using a turnover model by retrospectively analyzing the data obtained from previous controlled desaturation studies. Materials and Methods: Each volunteer was placed in a semi-Fowler's position and connected to a breathing circuit to administer the hypoxic gas mixture containing medical air, oxygen, nitrogen, and carbon dioxide. Volunteers were exposed to various levels of induced hypoxia over 70-100% arterial oxygen saturation (SaO2). The study period consisted of two rounds of hypoxia and the volunteers were maintained in room air between each round. FiO2 and SpO2 were recorded continuously during the study period. A population pharmacodynamic analysis was performed with the NONMEM VII level 4 (ICON Development Solutions, Ellicott City, MD, USA). Results: In total, 2899 SpO2 data points obtained from 20 volunteers were used to determine the pharmacodynamic characteristics. The pharmacodynamic parameters were as follows: kout = 0.942 1/min, Imax = 0.802, IC50 = 85.3%, γ = 27.3. Conclusion: The changes in SpO2 due to decreases in FiO2 well explained by the turnover model with inhibitory function as a sigmoidal model.

A study on the supply status of chemical substance information including MSDS and a way of improving Database management in Korea (국내 MSDS 등 화학물질정보의 제공실태와 DB관리 개선방안 연구)

  • Lee, Kwon Seob;Yoon, Seok Joon;Choi, Jae Wook;Kim, Hyun Ock;Lee, Jong Han;Yang, Jeong Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.63-70
    • /
    • 2007
  • This study investigated the current management staus of chemical substance information on Material Safety Data Sheets(MSDS) and Chemical Information Cards(CIC) provided by Korea Occupational Safety & Health Agency(KOSHA) and also researched the kind and the characteristics of chemical substance information provided in other organizations. MSDS DB in Korean provided on KOSHANET(which is Kosha website) is 50,802 in total, among whom are single chemical substances with 31,870 kinds(18,932%) and are mixed chemical substances with 31,870 kinds(62.7%). The number of visiting MSDS DB on KOSHANET for the search of chemicals was 2,049,806. The number has increased each year. The CIC provided for workplaces is all 542 kinds : 14 harmful substances subject to permission, 168 harmful substances subject to management, 360 KOEL(Korean Occupational Exposure Limits) establishment substances. MSDS internationally provided by organizations producing MSDS DB was written with 16 sections, which is suitable for the writing basis of American Standards Institute(ANSI) and International Organization for Standardization(ISO) and provided chemical substance information on more than 100,000 kinds in most organizations.

Analysis of Some Korean Terminologies on the Reproductive Structures of Seed Plants in Plant Morphology (식물형태학에서 사용하는 종자식물의 생식구조에 관한 한글 용어의 분석)

  • Lee, Kyu Bae
    • Journal of Integrative Natural Science
    • /
    • v.1 no.3
    • /
    • pp.195-209
    • /
    • 2008
  • Some Korean terminologies on reproductive structures of seed plants in plant morphology, written incorrectly in many books, were analysed to propose accurately expressed terminologies. 31 books in areas such as general biology, plant biology, plant morphology, and biological dictionaries and glossaries were selected to analyse the accuracy of the terminologies for reproductive structures in gymnosperms, e.g., cone or strobilus, seed (or ovulate) cone and pollen cone, and conifer(s) or coniferous plants, and for flower structures in angiosperms, e.g., corolla, anther, filament, pistillate (or female) flower and staminate (or male) flower, apocarpous, and syncarpous. The definition and etymology of the terminologies were traced in 4 textbooks of plant anatomy and 2 dictionaries of biology and botany written in English. On the basis of the definition, etymology, and principles for terminology formation according to the International Organization for Standardization (ISO 704:2000), reasonably expressed Korean terminologies were proposed. All of the 8 terminologies examined in this study were included in the glossary of biological terminologies, published by the Korean Association of Biological Sciences in 2005, and designated as an editorial source for science and biology textbooks for middle and high schools by Ministry of Education in 2007. However, the only 1 of the 8 terminologies described in the glossary were consistent with the proposed expression in the present study. These inconsistencies indicated the need for a reassessment of this glossary of biological terminologies. The newly proposed terminologies would facilitate mutual understanding between teachers and students of plant biology.

  • PDF

Analysis of Some Korean Terminologies on the Stem Structures in Plant Morphology (식물형태학 분야에서 사용하는 줄기의 구조에 관한 한글 용어의 분석)

  • Lee, Kyu Bae
    • Journal of Integrative Natural Science
    • /
    • v.1 no.3
    • /
    • pp.234-246
    • /
    • 2008
  • Korean terminologies on stem structures in plant morphology, written incorrectly in many books, were analysed to propose accurately expressed terminologies. 35 books in areas such as general biology, plant biology, plant morphology, and biological dictionaries and glossaries were selected to analyse the accuracy of the terminologies for seed structures, e.g., shoot and shoot system, rhizome, apical dominance, anticlinal and periclinal divisions, and intercalary and lateral meristems. The definition and etymology of the terminologies were traced in 4 textbooks of plant anatomy and 2 dictionaries of biology and botany written in English. On the basis of the definition, etymology, and principles for terminology formation according to the International Organization for Standardization (ISO 704:2000), reasonably expressed Korean terminologies were proposed. All of the 8 terminologies examined in this study were included in the glossary of biological terminologies, published by the Korean Association of Biological Sciences in 2005, and designated as an editorial source for science and biology textbooks for middle and high schools by Ministry of Education in 2007. However, the only 1 of the 8 terminologies described in the glossary were consistent with the proposed expression in the present study. These inconsistencies indicated the need for a reassessment of this glossary of biological terminologies. The validity of the proposed Korean terminologies was tested in a questionnaire sent to 17 professors teaching plant morphology or/and taxonomy at universities. A mean of 91.9% of the total respondents agreed with the Korean expressions proposed in this study. The new, proposed terminologies would facilitate mutual understanding between teachers and students of plant biology.

  • PDF

Iontophoretic Transdermal Delivery of Alendronate in Hairless Mouse Skin (In-vitro에서 전기이온영동법을 이용한 알렌드로네이트의 경피약물전달)

  • Jyoung, Jy-Young;Shim, Bae-Sun;Hwang, In-Sik;Cho, Dong-Eon
    • Polymer(Korea)
    • /
    • v.33 no.3
    • /
    • pp.237-242
    • /
    • 2009
  • This study examined the transdermal delivery of alendronate across hairless mouse skin. The effects of iontophoresis, perforation with a microneedle, and a combination of a microneedle pretreatment and iontophoresis were evaluated in vitro test. Hydrogel patches were polymerized by UN polymerization to supply a hydrogel patch to the iontophoretic transdermal drug delivery system. The alendronate content in the iontophoretic delivery patch was $5.0\;mg/cm^3$. The amounts of alendronate that permeated across the hairless mouse skin when current densities of 0.25 and $0.50\;mA/cm^2$ were supplied to the iontophoretic alendronate patch were $0.80{\pm}0.03$ and $2.00{\pm}0.02{\mu}g$, respectively. After pretreatment with a microneedle, the amounts of alendronate that permeated across the hairless mouse skin increased to $70.65{\pm}0.37$ and $162.23{\pm}0.40{\mu}g$, respectively. The biocompatibility of the iontophoretic alendronate patch was examined according to the international standardization organization 10993.

Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)

  • Lee, Jeong-Il;Lee, Cheol Min;Shim, In-Keun;Kim, Seong-Mi;Lee, Woo-Seok;Kim, Yoon-Shin
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2394-2398
    • /
    • 2013
  • Nicotine is the main component of environmental tobacco smoke, and its presence in indoor air is widely used as a secondhand-smoke indicator. Environmental tobacco smoke is a major source of indoor air pollution, but sufficient investigation of the uncertainty of its measurement, which mirrors the reliability of nicotine measurement, has not been performed. We calculated the uncertainty of measurement of indoor air nicotine concentration at low, medium, and high concentrations of 11.3798, 10.1977, $98.3768{\mu}g/m^3$, respectively, and we employed the Guide to the Expression of Uncertainty in Measurements (GUM), proposed by the International Organization for Standardization (ISO). The factors considered in determining the uncertainty were uncertainty of the calibration curve (calibration curve and repeated measurements), desorption efficiency, extraction volume, and sampling airflow (accuracy and acceptable limits of flowmeter). The measurement uncertainty was highest at low concentrations; the expanded measurement uncertainty is $0.9435{\mu}g/m^3$ and is represented as a relative uncertainty of 63.38%. At medium and high (concentrations, the relative uncertainty was 13.1% and 9.1%, respectively. The uncertainty of the calibration curve was largest for low indoor nicotine concentrations. To increase reliability of measurement in assessing the effect of secondhand smoke, measures such as increasing the sample injection rate ($1{\mu}L$ or more), increasing sampling volume to increase collected nicotine, and using gas chromatography-mass spectrometry (GC/MS) or GC/MS/MS, which has a lower quantitation threshold, rather than gas chromatography with nitrogen phosphorous detector, should be considered.

Effect of repetitive pecking at working length for glide path preparation using G-file

  • Ha, Jung-Hong;Jeon, Hyo-Jin;Abed, Rashid El;Chang, Seok-Woo;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.123-127
    • /
    • 2015
  • Objectives: Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods: The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). Results: The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Conclusions: Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.