• Title/Summary/Keyword: ISD Model

Search Result 74, Processing Time 0.021 seconds

Estimation and Weighting of Sub-band Reliability for Multi-band Speech Recognition (다중대역 음성인식을 위한 부대역 신뢰도의 추정 및 가중)

  • 조훈영;지상문;오영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.6
    • /
    • pp.552-558
    • /
    • 2002
  • Recently, based on the human speech recognition (HSR) model of Fletcher, the multi-band speech recognition has been intensively studied by many researchers. As a new automatic speech recognition (ASR) technique, the multi-band speech recognition splits the frequency domain into several sub-bands and recognizes each sub-band independently. The likelihood scores of sub-bands are weighted according to reliabilities of sub-bands and re-combined to make a final decision. This approach is known to be robust under noisy environments. When the noise is stationary a sub-band SNR can be estimated using the noise information in non-speech interval. However, if the noise is non-stationary it is not feasible to obtain the sub-band SNR. This paper proposes the inverse sub-band distance (ISD) weighting, where a distance of each sub-band is calculated by a stochastic matching of input feature vectors and hidden Markov models. The inverse distance is used as a sub-band weight. Experiments on 1500∼1800㎐ band-limited white noise and classical guitar sound revealed that the proposed method could represent the sub-band reliability effectively and improve the performance under both stationary and non-stationary band-limited noise environments.

Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge

  • Mir, Arash Poorsattar Bejeh;Mir, Morvarid Poorsattar Bejeh
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.163-167
    • /
    • 2012
  • Purpose: ANSI/ADA has established standards for adequate radiopacity. This study was aimed to assess the changes in radiopacity of composite resins according to various tube-target distances and exposure times. Materials and Methods: Five 1-mm thick samples of Filtek P60 and Clearfil composite resins were prepared and exposed with six tube-target distance/exposure time setups (i.e., 40 cm, 0.2 seconds; 30 cm, 0.2 seconds; 30 cm, 0.16 seconds, 30 cm, 0.12 seconds; 15 cm, 0.2 seconds; 15 cm, 0.12 seconds) performing at 70 kVp and 7 mA along with a 12-step aluminum stepwedge (1 mm incremental steps) using a PSP digital sensor. Thereafter, the radiopacities measured with Digora for Windows software 2.5 were converted to absorbencies (i.e., A=-log (1-G/255)), where A is the absorbency and G is the measured gray scale). Furthermore, the linear regression model of aluminum thickness and absorbency was developed and used to convert the radiopacity of dental materials to the equivalent aluminum thickness. In addition, all calculations were compared with those obtained from a modified 3-step stepwedge (i.e., using data for the 2nd, 5th, and 8th steps). Results: The radiopacities of the composite resins differed significantly with various setups (p<0.001) and between the materials (p<0.001). The best predicted model was obtained for the 30 cm 0.2 seconds setup ($R^2$=0.999). Data from the reduced modified stepwedge was remarkable and comparable with the 12-step stepwedge. Conclusion: Within the limits of the present study, our findings support that various setups might influence the radiopacity of dental materials on digital radiographs.

Development of Web Accessibility Curriculum (웹 접근성 교육과정 개발)

  • Hong, Soon-Goo;Kang, Young-Moo;Park, Seong-Je;Lee, Hyun-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.909-919
    • /
    • 2011
  • Web accessibility for information vulnerable people has been important due to the web sites are recognized as an essential tool in everyday life for information and knowledge acquisition. In addition, since Disability Discrimination Act has been enacted in 2008, the demand for human resources with skills of web accessibility has been increased. However, courses of web accessibility have yet not been provided by domestic universities. In this paper, based on the Tyler model and Instructional System Design(ISD) model, a web accessibility curriculum that can be adopted in domestic universities is developed. To this end, educational goals of web accessibility were set and web accessibility education contents and characteristics were analyzed from 423 domestic universities and 197 universities in 4 foreign countries. Finally, the curriculum was validated by accessibility experts. The suggested curriculum can be applied to web educations for universities and institutions.

The Effects of PBL-based Data Science Education classes using App Inventor on elementary student Computational Thinking and Creativity improvement (앱인벤터를 활용한 PBL 기반 데이터 사이언스 교육 수업이 초등학생의 컴퓨팅 사고력과 창의성 향상에 미치는 효과)

  • Kim, Yongmin
    • Journal of The Korean Association of Information Education
    • /
    • v.24 no.6
    • /
    • pp.551-562
    • /
    • 2020
  • The purpose of this study is to investigate the effects of Data Science Education classes using PBL-based App Inventor on elementary student Computational Thinking and Creativity. Based on the results of the pre-requisite analysis by Rossett's demand analysis model, PBL-based Data Science Education class was designed according to the procedure of ADDIE model which is 42 hours of classroom instruction for elementary student. As a result of the Paired t-test, it was proved that the Computational Thinking was statistically significantly improved in the post-test. In addition, as a result of the Paired t-test and Wilcoxon's signed rank test, it was found that the sub-factors of Creativity were 'Originality', 'Fluency', 'Closure', 'Average', and 'Index'. Therefore, it was confirmed that the PBL-based Data Science Education class using App Inventor is effective in improving Computational Thinking and Creativity of elementary student.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Age-stratified analysis of temporomandibular joint osteoarthritis using cone-beam computed tomography

  • Hee-Jeong Song;Hang-Moon Choi;Bo-Mi Shin;Young-Jun Kim;Moon-Soo Park;Cheul Kim
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.71-80
    • /
    • 2024
  • Purpose: This study aimed to evaluate age-stratified radiographic features in temporomandibular joint osteoarthritis using cone-beam computed tomography. Materials and Methods: In total, 210 joints from 183 patients(144 females, 39 males, ranging from 12 to 88 years old with a mean age of 44.75±19.97 years) diagnosed with temporomandibular joint osteoarthritis were stratified by age. Mandibular condyle position and bony changes (flattening, erosion, osteophytes, subchondral sclerosis, and subchondral pseudocysts in both the condyle and articular eminence, thickening of the glenoid fossa, joint space narrowing, and joint loose bodies) were evaluated through cone-beam computed tomography. After adjusting for sex, the association between age groups and radiographic findings was analyzed using both a multiple regression model and a multinomial logistic regression model(α=0.05). Results: The prevalence of joint space narrowing and protruded condyle position in the glenoid fossa significantly increased with age (P<0.05). The risks of bony changes, including osteophytes and subchondral pseudocysts in the condyle; flattening, erosion, osteophyte, and subchondral sclerosis in the articular eminence; joint loose bodies; and thickening of the glenoid fossa, also significantly rose with increasing age (P<0.05). The number of radiographic findings increased with age; in particular, the increase was more pronounced in the temporal bone than in the mandibular condyle (P<0.05). Conclusion: Increasing age was associated with a higher frequency and greater diversity of bony changes in the temporal bone, as well as a protruded condyle position in the glenoid fossa, resulting in noticeable joint space narrowing in temporomandibular joint osteoarthritis.

Deep learning system for distinguishing between nasopalatine duct cysts and radicular cysts arising in the midline region of the anterior maxilla on panoramic radiographs

  • Yoshitaka Kise;Chiaki Kuwada;Mizuho Mori;Motoki Fukuda;Yoshiko Ariji;Eiichiro Ariji
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.33-41
    • /
    • 2024
  • Purpose: The aims of this study were to create a deep learning model to distinguish between nasopalatine duct cysts (NDCs), radicular cysts, and no-lesions (normal) in the midline region of the anterior maxilla on panoramic radiographs and to compare its performance with that of dental residents. Materials and Methods: One hundred patients with a confirmed diagnosis of NDC (53 men, 47 women; average age, 44.6±16.5 years), 100 with radicular cysts (49 men, 51 women; average age, 47.5±16.4 years), and 100 with normal groups (56 men, 44 women; average age, 34.4±14.6 years) were enrolled in this study. Cases were randomly assigned to the training datasets (80%) and the test dataset (20%). Then, 20% of the training data were randomly assigned as validation data. A learning model was created using a customized DetectNet built in Digits version 5.0 (NVIDIA, Santa Clara, USA). The performance of the deep learning system was assessed and compared with that of two dental residents. Results: The performance of the deep learning system was superior to that of the dental residents except for the recall of radicular cysts. The areas under the curve (AUCs) for NDCs and radicular cysts in the deep learning system were significantly higher than those of the dental residents. The results for the dental residents revealed a significant difference in AUC between NDCs and normal groups. Conclusion: This study showed superior performance in detecting NDCs and radicular cysts and in distinguishing between these lesions and normal groups.

Position of the hyoid bone and its correlation with airway dimensions in different classes of skeletal malocclusion using cone-beam computed tomography

  • Shokri, Abbas;Mollabashi, Vahid;Zahedi, Foozie;Tapak, Leili
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.105-115
    • /
    • 2020
  • Purpose: This study investigated the position of the hyoid bone and its relationship with airway dimensions in different skeletal malocclusion classes using cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans of 180 participants were categorized based on the A point-nasion-B point angle into class I, class II, and class III malocclusions. Eight linear and 2 angular hyoid parameters(H-C3, H-EB, H-PNS, H-Me, H-X, H-Y, H-[C3-Me], C3-Me, H-S-Ba, and H-N-S) were measured. A 3-dimensional airway model was designed to measure the minimum cross-sectional area, volume, and total and upper airway length. The mean crosssectional area, morphology, and location of the airway were also evaluated. Data were analyzed using analysis of variance and the Pearson correlation test, with P values <0.05 indicating statistical significance. Results: The mean airway volume differed significantly among the malocclusion classes(P<0.05). The smallest and largest volumes were noted in class II (2107.8±844.7 ㎣) and class III (2826.6±2505.3 ㎣), respectively. The means of most hyoid parameters (C3-Me, C3-H, H-Eb, H-Me, H-S-Ba, H-N-S, and H-PNS) differed significantly among the malocclusion classes. In all classes, H-Eb was correlated with the minimum cross-sectional area and airway morphology, and H-PNS was correlated with total airway length. A significant correlation was also noted between H-Y and total airway length in class II and III malocclusions and between H-Y and upper airway length in class I malocclusions. Conclusion: The position of the hyoid bone was associated with airway dimensions and should be considered during orthognathic surgery due to the risk of airway obstruction.

A Study on Arbitration for Dispute Resolutions of the Commercial Transaction and the Investment in Central Asia (중앙아시아에서 무역과 투자분쟁해결을 위한 중재제도에 관한 고찰)

  • YU, Byoung-Uk
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.68
    • /
    • pp.123-148
    • /
    • 2015
  • Central Asian Countries had been independent in 1991 from USSR. Since then it have been increasing foreign trade and investment amount with outside countries including China, Japan, EU and South Korea. Korean enterprises and entities have endeavored to secure plentiful natural resources, oil and gas energy and expand the market share to exporting the consuming and industrial competitive goods and services for those countries. In the case of disputes of commercial transactions and investment, arbitration is regarded as a dispute resolution system which has been preferred in international transactions and investments by the business world. Since the collapse of the USSR, Central Asian Countries have worked to modernize its arbitration law and procedure to conform with international standard rules. Arbitral legislation in Central Asian countries is based on the Model Law as adopted in 1985. However, CIS's legislation systems of arbitration are not satisfied with the international standard in national laws and practices. That is the reason to consider for the specific parliament about arbitration for the dispute resolutions in the commercial transaction and investment between Korean enterprises and CIS. In this article, it is discuss problems and its alternatives in the dispute resolution about the commercial transaction and investment into Central Asian countries including the tendency to the increasing the trade volumes of goods and investment between South Korea and CIS. According to this article, South Korea consider the long term strategy followed the preferred economic relative partnership for business success on commercial transaction and investment with the Central Asian Countries.

  • PDF

Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

  • Nikneshan, Sima;Sharafi, Mohamad;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.191-196
    • /
    • 2013
  • Purpose: This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. Materials and Methods: Two acrylic models were fabricated from a cast with normal occlusion. Straight and $75^{\circ}$ mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an $8^{\circ}$ downward tilt of the occlusal plane compared to the standard position, at an $8^{\circ}$ upward tilt of the anterior occlusal plane, and at a $10^{\circ}$ downward tilt of the right and left sides of the model. On the radiographs, the length of the pins above (crown) and below (root) the occlusal plane, total pin length, crown-to-root ratio, and angulation of pins relative to the occlusal plane were calculated. The data were subjected to repeated measures ANOVA and LSD multiple comparisons tests. Results: Significant differences were noted between the radiographic measurements and true values in different positions on both models with linear (P<0.001) and those with angulated pins (P<0.005). No statistically significant differences were observed between the angular measurements and baselines of the natural head posture at different positions for the linear and angulated pins. Conclusion: Angular measurements on panoramic radiographs were sufficiently accurate and changes in the position of the occlusal plane equal to or less than $10^{\circ}$ had no significant effect on them. Some variations could exist in the pin positioning (head positioning), and they were tolerable while taking panoramic radiographs. Linear measurements showed the least errors in the standard position and $8^{\circ}$ upward tilt of the anterior part of the occlusal plane compared to other positions.