• Title/Summary/Keyword: IS50

Search Result 40,399, Processing Time 0.062 seconds

Influence of hot deformation and composition on microstructure development of magnesium-stannide alloys

  • Pandel, Divija;Banerjee, Malay K.
    • Advances in materials Research
    • /
    • v.9 no.3
    • /
    • pp.171-187
    • /
    • 2020
  • The microstructural evolution of different compositions of Mg-Sn alloys (30%Sn-70%Mg, 40%Sn-60%Mg and 50%Sn-50%Mg) is studied at first to understand the changes observed with change in tin content and deformation conditions. The Mg2Sn phase increases with increase in tin content and a significant substructure development is found in 50%Sn-50%Mg alloy. The above observation led to further deformation studies on Mg2Sn based thermoelectric materials with higher tin percentage. The microstructure in terms of Electron backscatter diffraction (EBSD)measurements is studied in detail followed by the determination of thermoelectric properties i.e., Seebeck coefficient and electrical conductivity for both as cast and extruded Mg(2+x)Sn-Ag alloys. The electrical conductivity of the extruded Mg(2+x)Sn-.3wt%Ag {x =1} alloy was found to be more than its as cast counterpart while the Seebeck coefficient values remained almost the same.

Error Detection Architecture for Modular Operations (Modular 연산에 대한 오류 탐지)

  • Kim, Chang Han;Chang, Nam Su
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.2
    • /
    • pp.193-199
    • /
    • 2017
  • In this paper, we proposed an architecture of error detection in $Z_N$ operations using $Z_{(2^r-1)N}$. The error detection can be simply constructed in hardware. The hardware overheads are only 50% and 1% with respectively space and time complexity. The architecture is very efficient because it is detection 99% for 1 bit fault. For 2 bit fault, it is detection 99% and 50% with respective r=2 and r=3.

Physical Properties of Ultra-fine Denier Filament Yarn Fabric

  • Kim, Jong-Jun;Son, Yang-Kug
    • Journal of Fashion Business
    • /
    • v.10 no.3
    • /
    • pp.23-30
    • /
    • 2006
  • Various high-touch textile products have been developed recently including ultra-fine denier filament yarn fabrics. The touch or hand of high value-added products is of prime importance. Physical and mechanical properties of fabric specimens, ultra-fine denier filament yarn fabric specimen, 100% wool fabric and wool/polyester 50:50 fabric,were measured using the KES. Compressibility of the ultra-fine denier fabric is recommendable, possibly due to the good bulk property of the specimen. Overall, the THV of the ultra-fine denier fabric is positioned between those of the 100% wool fabric and wool/polyester 50:50 fabric. Observed differences in the physical and mechanical properties explain the fabric specimen characteristics reasonably.

Operating Characteristics of 50kW Utility Interactive Photovoltaic System (조선대학교 기숙사전원용 50kW 태양광발전시스템 발전특성)

  • Park, Jeong-Min;Kim, Ji-Hun;Choi, Youn-Ok;Kim, Dae-Gon;Jang, Yong-He
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.720-722
    • /
    • 2005
  • A photovoltaic panel is a device that, through the photovoltaic effect, converts luminous energy into electric energy. Photovoltaic generation system uses infinity of solar energy, cost of fuel is needless and there is no all pollution or waste occurrence. This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW large scale applications installed In Chosun University dormitory roof. The status of PV system components, are inter-connection and safety equipment monitoring system will be summarized as this article. This describes configuration of utility interactive photovoltaic system which generated power supply for dormitory In this paper represent 50kw utility PV system examination result

  • PDF

generating characteristics of 50kW PV System by simulation tool (Simulation tool을 이용한 50kW PV System의 출력특성)

  • Park, J.M.;Jeong, B.H.;Piao, Z.G.;Lee, K.Y.;Cho, G.B.;Baek, H.L.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.337-339
    • /
    • 2005
  • A photovoltaic panel is a device that, through the photovoltaic effect, converts luminous energy into electric energy. Photovoltaic generation system uses infinity of sofa energy, cost of fuel is needless and there is no air pollution or waste occurrence. This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW large scale applications installed in Chosun University dormitory roof and simulation tool. This describes configuration of utility interactive photovoltaic system which generated power supply for dormitory. In this Paper represent 50kW utility PV system examination result.

  • PDF

Utility of Wearing Protective Apron for X-ray of Thick Subject (두꺼운 피사체 X선 촬영 시 보호앞치마 착용의 유용성)

  • Choi, Seong-Kwan;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.167-171
    • /
    • 2017
  • This study examined the effectiveness degree of a protective apron that is taken not to be exposed to the first ray or scattered rays, for X-ray of thick subject like lateral lumbar, and the results are as follows; First, spatial dose by scattered rays is shielded by 3 mmPb protective apron, 86.8% at a distance of 50 cm, 92.7% at 100 cm, and 95.6% at 200 cm, when minimizing the field size, while 89% at a distance of 50 cm, 92.3% at 100 cm, and 95.2% at 200 cm, when maximizing the field size. Second, 1st exposure dose is shielded by 3 mmPb protective apron, 93.7% at a distance of 50 cm, 94.4% at 100 cm, and 93.6% at 200 cm, when minimizing the field size, while 93.7% at a distance of 50 cm, 93.6% at 100 cm, and 94.2% at 200 cm, when maximizing the field size.

A Study on the Dielectric Characteristics of Insulation Gases for a Sub-cooled Liquid Nitrogen System (이용률을 이용한 과냉질소 냉각시스템용 절연가스의 절연특성에 관한 연구)

  • Kang, Hyoung-Ku;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.52-55
    • /
    • 2010
  • A sub-cooled liquid nitrogen system is known as a promising method to develop high voltage superconducting apparatuses such as superconducting fault current limiters (SFCLs) and superconducting cables. To develop a high voltage superconducting machine adopting the sub-cooled liquid nitrogen system with a constant pressure. injecting a non-condensable gas is indispensable. In this study. the dielectric characteristics of insulation gases are investigated and analyzed by using electric utilization factors ($\xi$). It is found that the maximum electric field at sparkover that occurs with 50 % probability. $E_{MAX.50%}$ exponentially decreases as the S increases. This means that the $E_{MAX.50%}$ at sparkover can be estimated with the $E_{MAX.50%}$

Study for determining cross docking point local bases approach (크로스도킹 거점 결정을 위한 연구 -지역거점을 중심으로-)

  • Kim, Ki-Hong
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.129-135
    • /
    • 2017
  • The respective delivering vehicle loaded with the own cargo moves into the respective delivery area. At the base, the delivery points D1 and D2, for example, have the same starting point but the destination is different. The average delivering time of the delivery vehicle is mostly more than 8 hours a day. Therefore, the efficiency of delivery is generally low. In this study, the deliveries will be forwarded from a base station to a delivery point where cross docking will be applied to a single vehicle, and will be distributed from the cross docking point through cross docking. If the distribution is implemented, one vehicle will not have to be operated from the base to the cross docking point. In that case, logistics cost will be reasonably saved by the reduction of transportation cost and labor time. If one vehicle only runs from the base to the cross docking point, each vehicle will be operated in two shifts, and the vehicle operation can be efficiently implemented. This research model is based on the assumption that the 3 types of ratios between the traffic volume of the vehicles starting at the base and the vehicles waiting at the cross docking point are set to the first ratio of 30% to 70%, the second ratio of 50% to 50% and the final ratio of 70% to 30%. As a result of the study, The delivery time in the cross docking point is much higher than that in present on the condition that the cargo volume in the D2 area is more than 50%. Likewise, the delivery time is slightly higher on the condition that the cargo volume is less than 50%. Time is reduced in terms of 50% model like AS-IS model.

Modified LOGIT(MLOGIT) Transformation: Prediction of $IC_{50}$ Value from Two Arbitrary Concentration Data

  • 유성은;차옥자
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.2
    • /
    • pp.110-112
    • /
    • 1995
  • A LOGIT transformation is a method to estimate IC50 values with two arbitrary concentration data when complete dose response curves(DRCs) are not available. We propose a modified LOGIT transformation (MLOGIT) which predicts IC50 values more accurately than the conventional LOGIT method.