• Title/Summary/Keyword: IRS method

Search Result 58, Processing Time 0.024 seconds

An Analysis of the Landuse Classification Accuracy Using PCA Merged Images from IRS-1C PAN Data and Landsat TM Data (IRS-1C PAN 데이터와 Landsat TM 데이터의 PCA 중합화상을 이용한 토지이용 분류 정확도 분석)

  • Ahn, Ki-Won;Lee, Hyo-Sung;Seo, Doo-Chun;Shin, Sok-Hyo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.7 no.1 s.13
    • /
    • pp.87-95
    • /
    • 1999
  • The min object of this study was to prove the effectiveness of PCA(principal component analysis) merged images produced by PCA method using high resolution IRS-1C PAN data and multispectral Landsat TM data A sample data which has ten classes was generated for evaluation of the overall classification accuracy. In result, merged sample image which TM13457 bands with IRS-1C PAN data by PCA method showed best result (95.1%). Especially, the largest improve (6.2%) in classification accuracy was resulted when IRS-1C PAN data was merged with TM123457 or TM13457 images. In addition, landuse classification accuracy of the PCA merged images was improved (5.16%) than original color composite images of Landsat TM data.

  • PDF

An Analysis of the Landuse Classification Accuracy Using IHS Merged Images from IRS-1C PAN Data and Landsat TM Data (IRS-1C PAN 데이터와 Landsat TM 데이터의 IHS중합화상을 이용한 토지이용분류 정확도 분석)

  • 안기원;이효성;서두천;신석효
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.2
    • /
    • pp.187-194
    • /
    • 1998
  • In this study, effective multispectral Landsat TM band combinations for a merging with the high resolution IRS-1C PAN data using the IHS method to improve landuse accuracy is discussed. From the pre-classified image using the merged images with TM all six band images(with the exception of band 6 image) and PAN image, a sample data which has ten classes was generated. An evaluation of the overall classification accuracy for the representative seven merged images which were merged using each TM three-band images and IRS-1C PAN image by IHS method for the sample area. The increase in classification accuracy is most significant with the inclusion of two of TM4, TM5 and TM7 infrared band images. Especially, the largest increase(11.8 percent) in landuse classification accuracy were investigated when Landsat TM247 bands were merged with IRS-1C PAN data. The classification accuracy when TM three band image and PAN image were used without merging is higher than result of the case of using the merged images.

  • PDF

Comparison of Infrequent Restriction Site-Polymerase Chain Reaction and Pulsed-Field Gel Electrophoresis for Molecular Typing of Staphylococcus aureus and Escherichia coli (황색포도구균과 대장균의 기준형별 결정에 있어서 Infrequent Restriction Site Polymerase Chain Reaction과 Pulsed-Field Gel Electrophoresis의 변별력 비교)

  • Shin, Wan-Shik;Kim, Tai-Gye;Choi, Jung-Hyun;Lee, Dong-Gun;Choi, Hee-Baeg;Yoo, Jin-Hong;Kim, Jong-Hyun;Kang, Jin-Han;Min, Woo-Sung
    • The Journal of the Korean Society for Microbiology
    • /
    • v.35 no.4
    • /
    • pp.289-297
    • /
    • 2000
  • Background: Staphylococcus aureus (s. aureus) and Escherichia coli (E. coli) are major pathogens in community and hospital. And they sometimes cause the outbreak in hospital in the immunocompromised patients. Pulsed-field gel electrophoresis (PFGE) has been regarded as a standard method for genotyping in epidemiologic studies, but it is laborious and time-consuming. Infrequent restriction site-polymerase chain reaction (IRS-PCR), a new genotyping methods, was performed to compare the applicability with PFGE. Methods: We performed PFGE and IRS-PCR on S. aurues (n=120) and E. coli (n=117) which were collected clinically in 4 different hospitals. We assessed each method in terms of discriminatory power, quality, and efficiency. Results: In E. coli, the discriminatory power of IRS-PCR was $46.7{\sim}86.7%$, and that of PFGE was $88.9{\sim}96.7%$ according to hospital. But in S. aurues, the discriminatory power of IRS-PCR was $20{\sim}56.7%$, and that of PFGE was $40{\sim}90%$ according to hospital. The typablity and reproducibility of IRS-PCR were 100% of each. PFGE needed four days to complete the procedure, but IRS-PCR could be performed within one day, IRS-PCR showed better resolution than PFGE. Conclusion: In case of gram negative bacteria (like E. coli), IRS-PCR could be a reliable alternative for epidemiologic typing due to better efficiency and comparable discriminatory power. But in the case of gram positive bacteria (like S. aureus), IRS-PCR does not seem to be suitable for the strain-to-strain differentiation. More trials and changes of restriction enzymes or primers could reveal the efficacy of IRS-PCR in the field of molecular typing.

  • PDF

Absolute Position Estimation Using IRS Satellite Images (IRS 위성영상을 이용한 절대위치 추정)

  • O, Yeong-Seok;Sim, Dong-Gyu;Park, Rae-Hong;Kim, Rin-Cheol;Lee, Sang-Uk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.5
    • /
    • pp.453-463
    • /
    • 2001
  • This paper presents an absolute position estimation method using Indian remote sensing (IRS) satellite images, which is a part of a position estimation (PE) system. The accumulated buffer (AB) matching method is proposed, in which a set of accumulator cells is employed for fast edge-based matching. By computer simulations with two sets of veal aerial image sequences, the performance of the AB matching method is analyzed and its effectiveness is shown in terms of the position error in the hybrid PE system.

  • PDF

Active and Passive Beamforming for IRS-Aided Vehicle Communication

  • Xiangping Kong;Yu Wang;Lei Zhang;Yulong Shang;Ziyan Jia
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.5
    • /
    • pp.1503-1515
    • /
    • 2023
  • This paper considers the jointly active and passive beamforming design in the IRS-aided MISO downlink vehicle communication system where both V2I and V2V communication paradigms coexist. We formulate the problem as an optimization problem aiming to minimize the total transmit power of the base station subject to SINR requirements of both V2I and V2V users, total transmit power of base station and IRS's phase shift constraints. To deal with this non-convex problem, we propose a method which can alternately optimize the active beamforming at the base station and the passive beamforming at the IRS. By using first-order Taylor expansion, matrix analysis theory and penalized convex-concave process method, the non-convex optimization problem with coupled variables is converted into two decoupled convex sub-problems. The simulation results show that the proposed alternate optimization algorithm can significantly decrease the total transmit power of the vehicle base station.

A modified index for damage detection of structures using improved reduction system method

  • Arefi, Shahin Lale;Gholizad, Amin;Seyedpoor, Seyed Mohammad
    • Smart Structures and Systems
    • /
    • v.25 no.1
    • /
    • pp.1-22
    • /
    • 2020
  • The modal strain energy method is one of the efficient methods for detecting damage in the structures. Due to existing some limitations in real-world structures, sensors can only be located on a limited number of degrees of freedom (DOFs) of a structure. Therefore, the mode shape values in all DOFs of structures cannot be measured. In this paper, a modified modal strain energy based index (MMSEBI) is introduced to locate damaged elements of structures when a limited number of sensors are used. The proposed MMSEBI is based on the reconstruction of mode shapes using Improved Reduction System (IRS) method. Therefore, in the first step by employing IRS method, mode shapes in slave degrees of freedom are estimated by those of master degrees of freedom. In the second step, the proposed MMSEBI is used to located damage elements. In order to evaluate the efficiency of the proposed method, two numerical examples are considered under different damage patterns considering the measurement noise. Moreover, the universal threshold based on statistical hypothesis testing principles is applied to damage index values. The results show the effectiveness of the proposed MMSEBI for the structural damage localization when comparing with the available damage index named MESBI. The results demonstrate that the presented method can be used as a practical strategy for structural damage identification, especially when a limited number of sensors are installed on the structure. Finally, the combination of MMSEBI and IRS method can provide a reliable tool to identify the location of damage accurately.

Iterated Improved Reduced System (IIRS) Method Combined with Sub-Structuring Scheme (I) - Undamped Structural Systems - (부구조화 기법을 연동한 반복적인 동적 축소법 (I) - 비감쇠 구조 시스템 -)

  • Choi, Dong-Soo;Kim, Hyun-Gi;Cho, Maeng-Hyo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.211-220
    • /
    • 2007
  • This work presents an iterated improved reduced system (IIRS) procedure combined with sub-structuring scheme for large structures. Iterated IRS methods are usually more efficient than others because the dynamic condensation matrix is updated repeatedly until the desired convergent values are obtained. However, using these methods simply for large structures causes expensive computational cost and even makes analyses intractable because of the limited computer storage. Therefore, the application of sub-structuring scheme is necessary. Because the large structures are subdivided into several (or more) sub-domains, the construction of dynamic condensation matrix does not require much computation cost in every iteration. This makes the present method much more efficient to compute the eigenpairs both in lower and intermediate modes. In Part I, iterated IRS method combined with sub-structuring scheme for undamped structures is presented. The validation of the proposed method and the evaluation of computational efficiency are demonstrated through the numerical examples.

Iterated Improved Reduced System (IIRS) Method Combined with Sub-Structuring Scheme (II) - Nonclassically Damped Structural Systems - (부구조화 기법을 연동한 반복적인 동적 축소법 (II) - 비비례 감쇠 구조 시스템 -)

  • Choi, Dong-Soo;Kim, Hyun-Gi;Cho, Maeng-Hyo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.221-230
    • /
    • 2007
  • An iterated improved reduced system (IIRS) procedure combined with sub-structuring scheme for nonclassically damped structural systems is presented. For dynamic analysis of such systems, complex eigenproperties are required to incorporate properly the nonclassical damping effect. In complex structural systems, the equations of motion are written in the state space from. Thus, the number of degrees of freedom of the new equations of motion and the size of the associated eigenvalue problem required to obtain the complex eigenvalues and eigenvectors are doubled. Iterated IRS method is an efficient reduction technique because the eigenproperties obtained in each iteration step improve the condensation matrix in the next iteration step. However, although this reduction technique reduces the size of problem drastically, it is not efficient to apply this technique to a single domain finite element model with degrees of freedom over several thousands. Therefore, for a practical application of the reduction method, accompanying sub-structuring scheme is necessary. In the present study, iterated IRS method combined with sub-structuring scheme for nonclssically damped structures is developed. Numerical examples demonstrate the convergence and the efficiency of a newly developed scheme.

Comparison of Different Methods to Merge IRS-1C PAN and Landsat TM Data (IRS-1C PAN 데이터와 Landsat TM 데이터의 종합방법 비교분석)

  • 안기원;서두천
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.2
    • /
    • pp.149-164
    • /
    • 1998
  • The main object of this study was to prove the effectiveness of different merging methods by using the high resolution IRS(Indian Remote Sensing Satellite)-1C panchromatic data and the multispectral Landsat TM data. The five methods used to merging the information contents of each of the satellite data were the intensity-hue-saturation(IHS), principal component analysis(PCA), high pass filter(HPF), ratio enhancement method and look-up-table(LUT) procedures. Two measures are used to evaluate the merging method. These measures include visual inspection and comparisons of the mean, standard deviation and root mean square error between merged image and original image data values of each band. The ratio enhancement method was well preserved the spectral characteristics of the data. From visual inspection, PCA method provide the best result, HPF next, ratio enhancement, IHS and LUT method the worst for the preservation of spatial resolution.

Investigation of the accuracy of different finite element model reduction techniques

  • Ghannadi, Parsa;Kourehli, Seyed Sina
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.3
    • /
    • pp.417-428
    • /
    • 2018
  • In this paper, various model reduction methods were assessed using a shear frame, plane and space truss structures. Each of the structures is one-dimensional, two-dimensional and three-dimensional, respectively. Three scenarios of poor, better, and the best were considered for each of the structures in which 25%, 40%, and 60% of the total degrees of freedom (DOFs) were measured in each of them, respectively. Natural frequencies of the full and reduced order structures were compared in each of the numerical examples to assess the performance of model reduction methods. Generally, it was found that system equivalent reduction expansion process (SEREP) provides full accuracy in the model reduction in all of the numerical examples and scenarios. Iterated improved reduced system (IIRS) was the second-best, providing acceptable results and lower error in higher modes in comparison to the improved reduced system (IRS) method. Although the Guyan's method has very low levels of accuracy. Structures were classified with the excitation frequency. High-frequency structures compared to low-frequency structures have been poor performance in the model reduction methods (Guyan, IRS, and IIRS).