• Title/Summary/Keyword: IR-cut off

Search Result 38, Processing Time 0.022 seconds

Triglyceride and Glucose (TyG) Index is a Clinical Surrogate Marker for the Diagnosis of Metabolic Syndrome

  • Shin, Kyung-A
    • Biomedical Science Letters
    • /
    • v.23 no.4
    • /
    • pp.348-354
    • /
    • 2017
  • TyG (triglyceride and glucose) index using triglyceride and fasting blood glucose is recommended as a useful marker for insulin resistance. The present study evaluated the usefulness of TyG index in diagnosing metabolic syndrome and suggested an optimal cut-off value. The subjects of this study were adult 4,415 adults aged 20 to 80 years who underwent health screening at J General Hospital from January 2016 to January 2017. Metabolic syndrome was based on AHA/NHLBI (American Heart Association/National Heart, Lung, and Blood Institute) criteria. TyG index correlated with metabolic syndrome risk factors including HOMA-IR. Compared with the participants in the lowest quartile of TyG index, odds ratios and 95% confidence intervals for metabolic syndrome were 8.5 (3.005~23.903), 20.0 (17.190~23.407) for those in the third, and the fourth quartile of TyG index. The optimal cut-off value of the metabolic syndrome was 8.81 for TyG index (sensitivity 86.7%, specificity 80.1%) and area under the ROC curve (AUC) was 0.894. In conclusion, TyG index is effective to identify individuals at risk for metabolic syndrome.

Properties of Multicomponent Glass Optical Fiber by adding $Ga_2O_3$ ($Ga_2O_3$ 첨가에 따른 다성분계 glass optical fiber의 특성)

  • 윤상하;강원호
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.210-216
    • /
    • 1997
  • The th ermal and optical properties of multicomponent oxide glass optical fiber by adding heavy metal oxide Ga$_{2}$O$_{3}$(0-20wt%) were investigated. The fiber samples were made by the method of rod in tube. The optical loss of fiber was measured in 0.3-1.8.mu.m wavelength region. As Ga$_{2}$O$_{3}$ increased up to 20wt%, the transition and softening temperature of bulk glass were increased from 495.deg. C to 579.deg. C and from 548.deg. C to 641.deg. C, respectively. Whereas the thermal expansion coefficient was decreased from 102 to 79.1x10$^{-7}$ /.deg. C. The refractive index was increased from 1.621 to 1.665, and IR cut-off wavelength was enlarged from 4.64.mu.m to 6.1.mu.m. The optical loss of fiber was remarkably decreased in 1.146.mu.m-1.8.mu.m wavelength region.

  • PDF

Effect of $SiO_2$ on the Properties of $CaO-Al_2O_3$ Glasses ($CaO-Al_2O_3$계 유리의 물성에 미치는 $SiO_2$의 영향)

  • 원종원;박용완
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.4
    • /
    • pp.389-398
    • /
    • 1994
  • Calcium aluminate glasses transmit light at relatively long wavelengths up to 6 ㎛ and exhibit also low Rayleigh scattering values. However they have a tendency to get devitrified easily, which limits their use as routine optical materials. Here, the ternary system CaO-Al2O3-SiO2 glasses with low-silica (<30 mol%) were prepared to prevent the devitrification of CaO-Al2O3 glasses and the properties were investigated as functions of composition. The addition of SiO2 to calcium aluminate glasses promoted their stability, which was due to the decrease of non-bridging oxygens and the reconnection of network. As SiO2 was added, density, refractive index, molar volume of oxygens and thermal expansion coefficient decreased continuously. But the glass transition temperatures with increasing SiO2 contents were raised and then lowered. It was postulated that the anomaly was related to the changes of the middle range order as well as the short range order. As the amount of SiO2 in the glass was increased, the IR cut-off values moved to shorter wavelength owing to 'Si-O' antisymetric stretching vibration. The IR cut-off wavelength of the glasses with 5 and 30 mol% SiO2 was 4.90, 4.55 ㎛, respectively.

  • PDF

Recovering the Colors of Objects from Multiple Near-IR Images

  • Kim, Ari;Oh, In-Hoo;Kim, Hong-Suk;Park, Seung-Ok;Park, Youngsik
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.102-111
    • /
    • 2015
  • This paper proposes an algorithm for recovering the colors of objects from multiple near-infrared (near-IR) images. The International Commission on Illumination (CIE) color coordinates of objects are recovered from a series of gray images captured under multiple spectral near-IR illuminations using polynomial regression. The feasibility of the proposed algorithm is tested experimentally by using 24 color patches of the Color Rendition Chart. The experimental apparatus is composed of a monochrome digital camera without an IR cut-off filter and a custom-designed LED illuminator emitting multiple spectral near-IR illuminations, with peak wavelengths near the red edge of the visible band, namely at 700, 740, 780, and 860 nm. The average color difference between the original and the recovered colors for all 24 patches was found to be 11.1. However, if some particular patches with high value are disregarded, the average color difference is reduced to 4.2, and this value is within the acceptability tolerance for complex image on the display.

Preamplier design for IR receiver IC (적외선 수신모듈IC용 전치증폭기의 설계)

  • Hong, Young-Uk;Ryu, Seung-Tak;Choi, Bae-Gun;Kim, Sang-Kyung;Baik, Sung-Ho;Cho, Gyu-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3124-3126
    • /
    • 2000
  • The application of IR(Infrared) communication is very wide and IR receiver has become a standard of home entertainment. A preamplifier with single 5V supply was designed for IR receiver IC. To operate at long distance, receiver IC should have high gain and low noise characteristic. To provide constant output signal magnitude, independent of transciever distance, gain limiting stage is needed. And to cut-off DC noise component effectively, large resistance and capacitance are required. Transimpedance type preamplifier, and diode limiting amplifier, and current limiting amplifier were designed. It is another function of current limiting amplifier that transforms single input signal to differential output signal. Using AMS BiCMOS model, both BJT version and MOS version was designed. Total power consumption is O.lmW, and IC size is $0.3mm^2$

  • PDF

An Adaptive Control of Symmetry Contribution Based Generalized Symmetry Transform (적응적 대칭기여도 제어 기반 일반화 대칭변환)

  • Jeon, Joon-Hyung;Lee, Seung-Hee;Park, Kil-Houm
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.2
    • /
    • pp.208-217
    • /
    • 2014
  • This paper propose an adaptive control of symmetry contribution based generalized symmetry transform. which can be controlled symmetry contribution according to the intensity orientation of two pixels. In the proposed method, we define the C-D(convergent and divergent)plane which represents convergence and divergence region of gradient pairs. and used the gaussian phase wight function, with respect to the distance from the gradient pair to an extreme point, in calculating the symmetry contribution. The proposed method can be detect the object more efficiently by adaptive controlling the cut-off frequency of the gaussian phase wight function. To evaluate a performance of the proposed method, we compare the proposed method and conventional GST method in various images including IR image. we prove that the proposed method have better performance in object detection.

Chemotherapy for Malignant Gliomas Based on Histoculture Drug Response Assay : A Pilot Study

  • Gwak, Ho-Shin;Park, Hyeon-Jin;Yoo, Heon;Youn, Sang-Min;Rhee, Chang-Hun;Lee, Seung-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.5
    • /
    • pp.426-433
    • /
    • 2011
  • Objective : The Histoculture Drug Response Assay (HDRA), which measures chemosensitivity using minced tumor tissue on drug-soaked gelfoam, has been expected to overcome the limitations of in vitro chemosensitivity test in part. We analyzed interim results of HDRA in malignant gliomas to see if the test can deserve further clinical trials. Methods : Thirty-three patients with malignant gliomas were operated and their tumor samples were examined for the chemosensitivity to 10 chosen drugs by HDRA. The most sensitive chemotherapy regimen among those pre-established was chosen based on the number of sensitive drugs or total inhibition rate (IR) of the regimen. The response was evaluated by 3 month magnetic resonance image. Results : Among 13 patients who underwent total resection of the tumor, 12 showed no evidence of disease and one patient revealed progression. The response rate in 20 patients with residual tumors was 55% (3 complete and 8 partial responses). HDRA sensitivity at the cut-off value of more than one sensitive drug in the applied regimen showed a sensitivity of 100%, specificity of 60% and predictability of 70%. Another cut-off value of >80% of total IR revealed a sensitivity of 100%, specificity of 69%, and predictability of 80%. For 12 newly diagnosed glioblastoma patients, median progression-free survival of the HDRA sensitive group was 21 months, while that of the non-sensitive group was 6 months ($p$=0.07). Conclusion : HDRA for malignant glioma was inferred as a feasible method to predict the chemotherapy response. We are encouraged to launch phase 2 clinical trial with chemosensitivity on HDRA.

Near-elliptic Core Triangular-lattice and Square-lattice PCFs: A Comparison of Birefringence, Cut-off and GVD Characteristics Towards Fiber Device Application

  • Maji, Partha Sona;Chaudhuri, Partha Roy
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.207-216
    • /
    • 2014
  • In this work, we report detailed numerical analysis of the near-elliptic core index-guiding triangular-lattice and square-lattice photonic crystal fiber (PCFs); where we numerically characterize the birefringence, single mode, cut-off behavior and group velocity dispersion and effective area properties. By varying geometry and examining the modal field profile we find that for the same relative values of $d/{\Lambda}$, triangular-lattice PCFs show higher birefringence whereas the square-lattice PCFs show a wider range of single-mode operation. Square-lattice PCF was found to be endlessly single-mode for higher air-filling fraction ($d/{\Lambda}$). Dispersion comparison between the two structures reveal that we need smaller lengths of triangular-lattice PCF for dispersion compensation whereas PCFs with square-lattice with nearer relative dispersion slope (RDS) can better compensate the broadband dispersion. Square-lattice PCFs show zero dispersion wavelength (ZDW) red-shifted, making it preferable for mid-IR supercontinuum generation (SCG) with highly non-linear chalcogenide material. Square-lattice PCFs show higher dispersion slope that leads to compression of the broadband, thus accumulating more power in the pulse. On the other hand, triangular-lattice PCF with flat dispersion profile can generate broader SCG. Square-lattice PCF with low Group Velocity Dispersion (GVD) at the anomalous dispersion corresponds to higher dispersion length ($L_D$) and higher degree of solitonic interaction. The effective area of square-lattice PCF is always greater than its triangular-lattice counterpart making it better suited for high power applications. We have also performed a comparison of the dispersion properties of between the symmetric-core and asymmetric-core triangular-lattice PCF. While we need smaller length of symmetric-core PCF for dispersion compensation, broadband dispersion compensation can be performed with asymmetric-core PCF. Mid-Infrared (IR) SCG can be better performed with asymmetric core PCF with compressed and high power pulse, while wider range of SCG can be performed with symmetric core PCF. Thus, this study will be extremely useful for designing/realizing fiber towards a custom application around these characteristics.

Ir-192 Brachytherapy Planning of Brain Tumor (Ir-192 방사성소선원에 의한 뇌종양의 치료계획)

  • Choi Tae Jin;Park Jeong Ho;Kim Ok Bae;Suh Soo Ji
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.277-281
    • /
    • 1988
  • Although widely used in external beam treatment planning, computed tomography scans are infrequent in incranial tumors by implanting of Radioactive isotope. This incranial brachytherapy has only become possible by using CT scans and stereotaxic operation methods. The coincidence of single source and tumor axes in brachytherapy is very important to determine the therapeutic dosages. Eventhough using the CT scan, according to spatial location of tumor tying, the section of tumor will be seen enlargement, cause the tumor will be cut off with slight angle to its axes. Correct analysis of tumor size from source is required for rotated axes in analytical geometry.

  • PDF

Properties of Sunglass Lenses by Non-Destructive Test for the Sunglass Standards (비파괴식 검사를 통한 선글라스의 품질에 관한 연구)

  • Lim, Yong-Moo;Shim, Moon-Sik;Sim, Hyun-Seog;Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.125-131
    • /
    • 2001
  • In this study, we compared the properties of 23 high and 55 low price sunglass lenses with the standards in the ordinary optical properties, materials, coloration, UV, IR and luminous transmittance, color acceptance for traffic signal, chromaticity and contrast sensitivity. The ordinary optical properties of the lenses met comparatively the requirements of the KS standard. The HIGH-type and LOW-type lenses were primarily made by glass and acrylate, respectively. In the coloration, HIGH-type was in group around neutral color but LOW-type was distributed widely on the line between 570 nm and 485 nm. There are fails in 7% of HIGH-type and 18% of LOW-type in the stimulus purity of the luminous transmittance. Wavelength of the UV/VIS cut-off was over 350 nm for HIGH-type but 6% of LOW-type was under 350 nm. In the erythemal UV, all HIGH-type met the needs of standards but 5 LOW-type failed with DIN standard In the near UV, KS standard worked in stringency, and HIGH-type showed more failure than LOW-type. The characteristics of the IR transmittance of HIGH-type was better than that of LOW-type. In the color acceptance of traffic signal, all HIGH-type met the needs of ANSI standards but 21.8% of LOW-type failed with the standard. In the contrast sensitivity tested with various coloured sunglasses, the value increased with increasing of Land decreasing of test distance. In view of the results so far, HIGH-type met with excellent properties as compared with LOW-type.

  • PDF