• 제목/요약/키워드: IR signal

검색결과 237건 처리시간 0.022초

Synthesis and Characterization of Tetrathiafulvalene Charge Transfer Compounds with Iron and Antimony Halides

  • Kim Young In;Choi Sung Nak;Jung Woo Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권6호
    • /
    • pp.465-468
    • /
    • 1994
  • The charge transfer compounds $(TTF)_4FeCl_3{\cdot}CH_3OH,\;(TTF)_4SbCl_4\;and\;(TTF)_5(SbBr_4)_2{\cdot}CH_3COCH_3$ were prepared from reactions of the TTF (tetrathiafulvalene) and metal halides. The compounds were characterized by spectroscopic (UV,IR, EPR and XPS) methods, magnetic susceptibility and electrical conductivity measurements. The d.c electrical conductivities of the pressed pellets are in the order of $10^{-1}-10^{-3} Scm^{-1}$, which lies in the range of semiconductor region at room temperature. It means that the partially ionized TTF has stacked in low-dimensional chain in each compound. Spectroscopic properties also indicate that TTF molecules are partially ionized and charge transfer has occurred from (TTF)n to Fe(III) center in $(TTF)_4FeCl_3{\cdot}CH_3OH$ whereas to the $-SbX_4^-$ entity in $(TTF)_4SbCl_4\;and\;(TTF)_5(SbBr_4)_2{\cdot}CH_3COCH_3$. The EPR g values are consistent with TTF radical formation and EPR linewidths suggest the delocalization of unpaired electrons along TTF stacks. A signal arised from metal (Fe and Sb) ions were not detected in EPR spectra, indicating that metal ion is in the diamagnetic state in each compound. The diamagnetic state was also examined by the magnetic susceptibility measurement. The magnetic properties reveal the significant interaction between the $TTF^+$ radical cations in the stacks. The oxidation state of metal ions was also investigated by XPS spectra.

Adaptive Range-Based Collision Avoidance MAC Protocol in Wireless Full-duplex Ad Hoc Networks

  • Song, Yu;Qi, Wangdong;Cheng, Wenchi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권6호
    • /
    • pp.3000-3022
    • /
    • 2019
  • Full-duplex (FD) technologies enable wireless nodes to simultaneously transmit and receive signal using the same frequency-band. The FD modes could improve their physical layer throughputs. However, in the wireless ad hoc networks, the FD communications also produce new interference risks. On the one hand, the interference ranges (IRs) of the nodes are enlarged when they work in the FD mode. On the other hand, for each FD pair, the FD communication may cause the potential hidden terminal problems to appear around the both sides. In this paper, to avoid the interference risks, we first model the IR of each node when it works in the FD mode, and then analyze the conditions to be satisfied among the transmission ranges (TRs), carrier-sensing ranges (CSRs), and IRs of the FD pair. Furthermore, in the media access control (MAC) layer, we propose a specific method and protocol for collision avoidance. Based on the modified Omnet++ simulator, we conduct the simulations to validate and evaluate the proposed FD MAC protocol, showing that it can reduce the collisions effectively. When the hidden terminal problem is serious, compared with the existing typical FD MAC protocol, our protocol can increase the system throughput by 80%~90%.

산화성 손상을 받은 N18D3세포에서 Epigallocatechin gallate가 Phosphoinositide 3-kinase/Akt 및 Glycogen synthase kinase-3경로에 미치는 효과 (Effect of Epigallocatechin Gallate on Phosphoinositide 3-kinase/Akt and Glycogen Synthase Kinase-3 Pathway in Oxidative-stressed N18D3 Cells Following $H_2O_2$ Exposure)

  • 고성호;권혁성;오화순;오재호;박윤주;김준규;김기석;김용순;양기화;김승업;김승현;정해관
    • 한국임상약학회지
    • /
    • 제13권1호
    • /
    • pp.29-39
    • /
    • 2003
  • Neurodegenerative disorders are associated with apoptosis as a causing factor or an inducer. On the other hand, it has been reported that epigallocatechin gallate (EUG), one of antioxidants and flavonoids, and z-VAD-fmk, a nonselective caspase inhibitor, suppress oxidative-radical-stress-induced apoptosis. However, it is not yet known what is the effects of EGCG and z-VAD-fmk on the apoptotic pathway is through phosphoinositide 3-kinase (PI3K), Akt and glycogen synthase kinase-3 (GSK-3) as well as mitochondria, caspase-3 and poly (ADP-ribose) polymerase (PARP). We investigated the effects of EGCG by using $H_2O_2$ treated N18D3 cells, mouse DRG hybrid neurons. Methods: Following 30 min $100\;{\mu}m\;H_2O_2$ exposure, the viability of N18D3 cells (not pretreated vs. EGCG or z-VAD-fmk pretreated) was evaluated by using MTT assay. The effect of EGCG on immunoreactivity (IR) of cytochrome c, caspase-3, PARP, PI3K/Akt and GSK-3 was examined by using Western blot, and was compared with that of z-Y4D-fmk. Results: EGCG or z-VAD-fmk pretreated N18D3 cells showed increased viability. Dose-dependent inhibition of caspase-3 activation accompanied by PARP cleavage were demonstrated by pretreatment of both agents. However, inhibition of cytochrome c release was only detected in EGCG pretreated N18D3 cells. On the pathway through PI3K/Akt and GSK-3, however, the result of Western blot in EGCG pretreated N18D3 cells showed decreased IR of Akt and GSK-3 and increased IR of p85a PI3K, phosphorylated Akt and GSK-3, and contrasted with that in z-VAD-fmk pretreated N18D3 cells showing no changes on each molecule. Conclusion: These data show that EGCG affects apoptotic pathway through upstream signal including PI3K/Akt and GSK-3 pathway as well as downstream signal including cytochrome c and caspase-3 pathway. Therefore, these results suggest that EGCG mediated activation of PI3K/Akt and inhibition GSK-B could be new potential therapeutic strategy for neurodegenerative diseases associated with oxidative injury.

  • PDF

금속문화재 접합 복원용 에폭시 접착제의 내후성 연구 (The Study on the Weathering Characteristics about Epoxy Adhesive for the Adhesion and Restoration of Metallic Cultural Assets)

  • 이지현;위광철
    • 보존과학회지
    • /
    • 제26권1호
    • /
    • pp.61-67
    • /
    • 2010
  • 기존에 연구되어 온 금속 유물 접착용 에폭시 수지인 $Araldite^{(R)}$ rapid type, $Devcon^{(R)}$, $Araldite^{(R)}$ SV427+HV427, $CDK^{(R)}$520, $Araldite^{(R)}$ AW106+HV953 5 종을 선별하여 이들 수지의 문제점인 황변과 시간에 따라 나타날 수 있는 노화징후를 금속 문화재의 안전과 연결하여 접근하였다. 금속문화재 보존처리 후, 생길 수 있는 환경 변화 조건인 자외선 조사, 산 염기 상황을 인공적으로 극악하게 부여하였으며, 이들의 물성 변화를 굴곡 강도 변화와 표면 경도 변화를 통해 알아보고, 이 결과들을 FT-IR을 연결, 분석하여 그 변성 원인을 화학적으로 추적하고자 하였다. 자외선 조사 및 산 염기 환경에서 노출된 에폭시 수지들은 노출 전후에 굴곡 강도, 표면 경도들의 물리적 변성과 알코올의 생성 등의 화학적 변성이 나타났다. 대부분의 조건에서 SV427+HV427과 $CDK^{(R)}$520이 비교적 각 내후성 조건 아래 안정적이었지만, 자체의 굴곡 강도 수치가 낮아 복원 면적이 얇고 넓은 경우의 사용은 자제해야 할 것으로 보인다. 또한 보존 환경이 유물은 물론이고 보존처리 시 사용된 수지의 보존을 위해서도 매우 중요하다는 것을 알 수 있었다.

란탄족 이온이 도핑된 Ti-SBA-15의 합성 및 그들의 광촉매 활성 (Synthesis of Ti-SBA-15 Doped with Lanthanide Ions and Their Photocatalytic Activity)

  • 홍성수
    • 청정기술
    • /
    • 제26권1호
    • /
    • pp.7-12
    • /
    • 2020
  • 란탄족 이온이 도핑된 Ti-SBA-15 촉매를 수열합성법으로 제조하였다. 또한 이들의 특성을 X선 회절기(X-ray diffraction, XRD), Fourier-transform infrared spectroscopy (FT-IR), Diffuse reflectance spectroscopy (DRS), 가스흡착법(Brunauer-Emmett-Teller, BET) 및 Photoluminescence spectrometer (PL) 등을 이용하여 조사하였고, 이 촉매를 사용하여 자외선 조사하에서 메틸렌블루에 대한 광분해 반응성을 조사하였다. 란탄족 이온이 도핑과 무관하게 Ti-SBA-15 촉매는 메조동공체 구조를 유지하고 있으며, 란탄족 이온이 치환됨에 따라 기공의 크기와 기공의 부피가 줄어들었으며 표면적은 오히려 증가하였다. 란탄족 이온의 도핑과 무관하게 전체적으로 IV형의 흡착등온선과 H2형 히스테리시스를 보여주고 있으나, 란탄족 이온이 도핑되면 히스테리시스의 크기가 커지는 것을 볼 수 있다. 란탄족 이온의 도핑과 무관하게 가시광 영역에서의 흡수밴드는 나타나지 않으며 220 nm에서 다소 폭이 넓은 흡수피크가 나타나고 있다. 이것은 SBA-15 골격 내에 Ti가 존재한다는 것을 의미하고 있다. 메틸렌블루의 광분해 반응에서 Pr 이온을 첨가 시킨 것이 가장 높은 광촉매 활성을 보여주었으며, Er, Eu 및 Nd 등의 란탄족 이온이 치환되면 순수한 Ti-SBA-15 촉매보다 오히려 활성이 떨어진 것을 볼 수 있다. 모든 촉매들은 410 nm 부근에서 강하고 넓은 PL 흡수밴드가 나타났으며, 이 피크의 세기가 커질수록 광분해 활성이 증가하는 것으로 나타났다.

Identification of Petroselinic Acid (Cis-6-octadecenoic Acid) in the Seed Oils of Some of the Family Umbelliferae (Panax schinseng, Aralia continentalis and Acanthopanax sessiliflorus) by GC-MS, IR, $^1H-and$ $^13C-NMR$ Spectroscopic Techniques

  • Kim, Seong-Jin
    • 한국응용과학기술학회지
    • /
    • 제22권4호
    • /
    • pp.323-331
    • /
    • 2005
  • Fatty acid compositions of the seed oils of P. schinseng, A. continentalis and A. sessiliflorus, were analyzed by gas chromatography (GC) equipped with a capillary column. A large unusual peak was observed just before the peak corresponding to oleic acid $(cis-9-C_{18:1})$. This unknown fatty acid was isolated by silver ion chromatography and then derivatized into the picolinyl ester. The mass spectrum of the picolinyl ester showed molecular ion at m/z=373 with other diagnostic ions such as m/z=178, 218, 232, 246, 274, 288, 302 and 344. Characteristic absorption peaks at $720\;cm^{-1}$, $1640\;cm^{-1}$ and $3010\;cm^{-1}$ in IR spectrum indicated the presence of cis-configurational double bond in the molecule. The $^1H-NMR$ spectrum of this acid gave two quintets centered at ${\delta}1.638$ (2H, C-3) and ${\delta}1.377$ (2H, C-4), and two multiplets centered at ${\delta}2.022{\sim}2.047$ (2H, C-5) and ${\delta}2.000{\sim}2.022$ (2H, C-8), and multiplet signals of olefinic protons centered at ${\delta}5.3015{\sim}5.3426$ (C-6, J=9.5 Hz) and ${\delta}\;5.3465{\sim}5.3877$ (C-7, J=9.5 Hz). The $^13C-NMR$ spectrum showed 18 carbon resonance signals including an overlapped signal at ${\delta}29.7002$ for C-12 and ${\delta}29.6520$ for C-13 (or they can be reversed), and other highly resolved signals at ${\delta}33.950$, ${\delta}24.558$, ${\delta}26.773$ and ${\delta}27.205$ due to C-2, C-3, C-5 and C-8 of a ${\Delta}^6-octadecenoic$ acid, respectively. From analysis results this unknown fatty acid could be identified as cis-6-octadecenoic acid. The seed oils of P. schinseng and A. sessiliflorus contained petroselinic acid (59.7%, 56.0%), oleic acid (18.3%, 6.1%) and linoleic acid (16.2%, 30.4%) with small amount of palmitic acid (3.0%, 3.1%) while the seed oil of A. continentalis comprised mainly oleic acid (30.2%), petroselinic acid (29.0%), linoleic acid (24.1%) and palmitic acid (13.1%).

초전형 적외선 센서의 3차원 모델링과 최적화된 주변회로 설계 (3-D Simulation of Pyroelectric IR Sensor and Design of Optimized Peripheral Circuit)

  • 민경진;강성준;윤영섭
    • 대한전자공학회논문지SD
    • /
    • 제37권10호
    • /
    • pp.33-41
    • /
    • 2000
  • 본 연구에서는 전압감도, 잡음등가전력, 비검출능 등이 초전특성들을 각 파라미터의 상호작용을 고려하여 3차원으로 모델링하였다. 그 결과, 전압응답특성은 저주파수 영역의 경우, 단면적에 대한 의존성 없이 두께가 작을수록 큰 전압응답을 보이고, 고주파수 영역의 경우는 20$G{\Omega}$의 부하저항에서 단면적이 작을수록 우수한 전압응답을 보이지만 두께에는 전혀 의존하지 않음을 알 수 있었다. 비검출능은 저주파수 영역에서 20$G{\Omega}$의 부하저항, $4{\times}10^{-10}m^2$ 이상의 단면적, 그리고 $1{\times}10^{-5}m$ 이하의 두께에서 아주 우수한 특성을 나타내었고, 고주파수 영역에서는 $1{\times}10^{-5}m$ 이하의 두께와 $2{\times}10^{-10}m^2$ 이상의 단면적에서 저항에 관계없이 높은 비검출능을 나타내었다. 또, 초전형 적외선 센서의 증폭 및 주파수 대역을 설정하기 위한 주변회로를 설계하였다. 본 연구에서는 1개의 단일 op-amp를 JFET의 드레인 부분의 단자에 연결한 quasi-boot-strap 회로를 사용하여, 2개의 op-amp를 이용한 상용화된 주변회로에 비해 약 56%의 잡음저하와 원하는 주파수 대역 및 증폭도를 얻을 수 있었다.

  • PDF

근접방사선치료용 CsPbBr3 선량계 제작 및 적용가능성 평가 (Development and Feasibility Evaluation of CsPbBr3 Dosimeter for Brachytherapy)

  • 양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제16권4호
    • /
    • pp.405-410
    • /
    • 2022
  • 근접방사선치료에서는 종양조직을 사멸시키기 위하여 선원을 인체 내부에 삽입하기 때문에 선원의 위치 정확성을 정확히 파악하는 것이 중요하다. 본 연구에서는 기존 사용되는 검출기 재료로 사용되는 물질보다 저렴하고 제조 공정이 간단하여 기존 물질들을 대체할 수 있는 CsPbBr3를 사용하여 근접방사선치료용으로 사용가능한 선량계를 개발하고자 하였다. 그리고 192Ir 선원에서의 재현성, 선형성, 거리의존성 분석하여 선량계의 기초 성능을 평가하였다. 재현성 평가 결과, RSD는 1.36%로 기준치 1.5%를 만족하였다. 선형회귀분석에 따른 선형성 평가결과, 0.9993의 R2값으로 기준치 0.9990 이상의 R2이 제시되었다. 거리의존성 평가결과 거리가 멀어짐에 따라 지수적으로 일정하게 감소하는 신호값을 확인하였다. 재현성, 선형성, 거리의존성 평가결과에 기준 이상의 성능을 제시하여 제작된 CsPbBr3 선량계가 근접방사선치료용 선량계로 활용 가능한 것으로 보여주었다.

Atmospheric correction by Spectral Shape Matching Method (SSMM): Accounting for horizontal inhomogeneity of the atmosphere

  • ;안유환
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 춘계학술대회 논문집
    • /
    • pp.341-343
    • /
    • 2006
  • The current spectral shape matching method (SSMM), developed by Ahn and Shanmugam (2004), relies on the assumption that the path radiance resulting from scattered photons due to air molecules and aerosols and possibly direct-reflected light from the air-sea interface is spatially homogeneous over the sub-scene of interest, enabling the retrieval of water-leaving radiances ($L_w$) from the satellite ocean color image data. This assumption remains valid for the clear atmospheric conditions, but when the distribution of aerosol loadings varies dramatically the above postulation of spatial homogeneity will be violated. In this study, we present the second version of SSMM which will take into account the horizontal variations of aerosol loading in the correction of atmospheric effects in SeaWiFS ocean color image data. The new version includes models for the correction of the effects of aerosols and Raleigh particles and a method fur computation of diffuse transmittance ($t_{os}$) as similar to SeaWiFS. We tested this method over the different optical environments and compared its effectiveness with the results of standard atmospheric correction (SAC) algorithm (Gordon and Wang, 1994) and those from in-situ observations. Findings revealed that the SAC algorithm appeared to distort the spectral shape of water-leaving radiance spectra in suspended sediments (SS) and algal bloom dominated-areas and frequently yielded underestimated or often negative values in the lower green and blue part of the electromagnetic spectrum. Retrieval of water-leaving radiances in coastal waters with very high sediments, for instance = > 8g $m^{-3}$, was not possible with the SAC algorithm. As the current SAC algorithm does not include models for the Asian aerosols, the water-leaving radiances over the aerosol-dominated areas could not be retrieved from the image and large errors often resulted from an inappropriate extrapolation of the estimated aerosol radiance from two IR bands to visible spectrum. In contrast to the above results, the new SSMM enabled accurate retrieval of water-leaving radiances in a various range of turbid waters with SS concentrations from 1 to 100 g $m^{-3}$ that closely matched with those from the in-situ observations. Regardless of the spectral band, the RMS error deviation was minimum of 0.003 and maximum of 0.46, in contrast with those of 0.26 and 0.81, respectively, for SAC algorithm. The new SSMM also remove all aerosol effects excluding areas for which the signal-to-noise ratio is much lower than the water signal.

  • PDF

분석툴을 이용한 천리안2A 기상탑재체 복사 보정 파라미터 검증 (Verification of GEO-KOMPSAT-2A AMI Radiometric Calibration Parameters Using an Evaluation Tool)

  • 진경욱;박진형
    • 대한원격탐사학회지
    • /
    • 제36권6_1호
    • /
    • pp.1323-1337
    • /
    • 2020
  • 천리안2A호 AMI(Advanced Meteorological Imager) 복사 보정에 대한 검증은 탑재체의 기능 및 성능 점검뿐만 아니라, 탑재체 자료의 품질을 결정 짓는 중요한 요소이다. AMI 탑재체는 여섯 개의 가시 및 근적외 채널과 10개의 열적외 채널로 구성되어 있다. 가시/근적외 채널의 복사 성능을 대표하는 핵심적인 파라미터로는 SNR(Signal-to-Noise Ratio), 열적외채널의 경우는 NEdT(Noise Equivalent delta Temperature)를 들 수 있다. 다이나믹 레인지와 검출기의 반응도와 관련된 Gain 값 또한 복사 보정 성능과 관련된 중요한 파라미터이다. AMI 탑재체의 주요 복사 보정 성능 검증을 위해, 실시간 AMI자료 처리 시스템과는 별도의 오프라인 복사 성능 분석 툴을 개발하였다. 개발된 분석 툴을 이용하여 천리안2A호 발사 후 궤도상 시험 기간 동안 검증 작업을 수행하였다. 분석 툴을 통한 계산 결과는 탑재체 개발업체인 HARRIS사의 분석 값과 비교 검증하였다. AMI 복사 성능 검증 작업은 총 세차례로 나누어 AMI탑재체 양쪽 면인 Side1과 Side2에 대해 이루어졌다. 복사 성능 검증 결과 주요 복사 보정 파라미터들의 성능은 요구조건 값들을 크게 상회하는 우수한 성능을 보여 주었으며, AMI 복사 성능 분석 툴의 유효성이 입증되었다.