• Title/Summary/Keyword: IR laser

Search Result 200, Processing Time 0.03 seconds

Effects of the Low Power He-Ne IR Laser Treatment on the Liver Damage Induced with $CCI_4$ in Rats

  • Rho Min-Hee;Kim Jai-Young
    • Biomedical Science Letters
    • /
    • v.10 no.3
    • /
    • pp.231-235
    • /
    • 2004
  • This study was investigated the effects of the lower power He-Ne IR laser treatment on the changes of blood biochemical components in the rat liver damaged by the carbon tetrachloride (CCl₄). The twenty one Sprague-Dawley adult male rats weights (260±18.6 g) were designed to the three groups: one control group and two experimental groups, the experimental groups were divided into the CCl₄-treated groups and the laser therapy group (CCl₄+ Laser). The experimental groups were injected twice with CCl₄(1.0 ml/kg body weight) intraperitoneal for two days. Each group was sacrificed after two weeks irradiated with the lower power He-Ne IR laser for ten minutes per every day. The activity of alanine aminotransferase (ALT), lactic dehydrogenase (LDH), alkaline phosphatase (ALP) and the concentration of serum glucose treated with He-Ne IR laser groups was significantly decreased to the conrtol (treated with carbon CCl₄) group. The activity of aspartate aminotransferase (AST) was decreased in the laser group but not significantly, the concentration of the serum cholesterol in the laser group was significantly increased comparing with the control and case control groups. In conclusion, the effect of the lower power He-Ne IR laser treatment is believed to be a possible protective effects for CCl₄ induced acute hepatotoxicity in rats.

  • PDF

Effects of the low power He-Ne IR laser on the healing of the peripheral neuropathy in diabetic rats (저에너지 He-Ne IR laser가 당뇨쥐 말초 신경병증 치유에 미치는 영향)

  • Rho, Min-Hee;Lee, Hyun-Ok;Baek, Su-Jeong;Lee, Mi-Ae
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.559-565
    • /
    • 2000
  • This studies were to investigate the effects of low power Helium-Neon Infra-Red (He-Ne IR) laser on the healing of the peripheral neuropathy in diabetic rats. The twenty one Spraque-Dewley adult male rats were assigned to the 3 groups: the control group (7), the diabetic group (7) and the laser group (7). The diabetic group was induced with a single intravenous injection of 50mg/kg body weight streptozotocin dissolved to 0.01mol/L citrate buffer, pH 4.5. The experimental laser group was irradiated low power He-Ne IR laser for 5 minutes every day during 21 days to the diabetic group. The results were as follows: For on and two weeks with laser treatment, there were significantly increased the terminal latencies of the laser treatment group than those of diabetic group, but that was significantly decreased to be similar to the control group on the laser treatment group for three weeks. The change of the amplitude on the laser treatment groups for three weeks was significantly increased to be similar to normal group than that of the diabetic group. As the result, we thank that there were activately effected of lower power He-Ne IR laser on the heeling of the peripheral neurophathy in diabetic rats.

  • PDF

A Study on the Optimization of IR Laser Flip-chip Bonding Process Using Taguchi Methods (다구찌법을 이용한 IR 레이저 Flip-chip 접합공정 최적화 연구)

  • Song, Chun-Sam;Ji, Hyun-Sik;Kim, Joo-Han;Kim, Jong-Hyeong;Ahn, Hyo-Sok
    • Journal of Welding and Joining
    • /
    • v.26 no.3
    • /
    • pp.30-36
    • /
    • 2008
  • A flip-chip bonding system using IR laser with a wavelength of 1064 nm was developed and associated process parameters were analyzed using Taguchi methods. An infrared laser beam is designed to transmit through a silicon chip and used for transferring laser energy directly to micro-bumps. This process has several advantages: minimized heat affect zone, fast bonding and good reliability in the microchip bonding interface. Approximately 50 % of the irradiated energy can be directly used for bonding the solder bumps with a few seconds of bonding time. A flip-chip with 120 solder bumps was used for this experiment and the composition of the solder bump was Sn3.0Ag0.5Cu. The main processing parameters for IR laser flip-chip bonding were laser power, scanning speed, a spot size and UBM thickness. Taguchi methods were applied for optimizing these four main processing parameters. The optimized bump shape and its shear force were modeled and the experimental results were compared with them. The analysis results indicate that the bump shape and its shear force are dominantly influenced by laser power and scanning speed over a laser spot size. In addition, various effects of processing parameters for IR laser flip-chip bonding are presented and discussed.

The Effects of the low power intensity He-Ne IR laser on the change of the Serum Immunoglobulin components in burn rat (저 에너지 레이저 강도가 화상흰쥐의 혈청 면역글로불린의 성분 변화에 미치는 효과)

  • Rho Min-Hee;Kim Jae-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.3
    • /
    • pp.469-474
    • /
    • 2000
  • This studies were to investigate the effects of low power intensity Helium-Neon Infra-Red(He-Ne IR) laser on the changes of the serum immunoglobulin(1g) components in burn rats, The fourty eight Spraque-Dawley adult male rats were assigned to the 8 groups: the experimental groups(4), the burn control groups(2) and the control groups(2) There was made three degree burn by the 250mW IR on the back of each rats, from 3 days after being burned, the experimental laser groups were irradiated low power He-Ne IR laser for 3 minutes and 4.5 minutes every day during the 7days and 21 days. The results were as follows: The concentrations of immunoglobulin G(Ig G) in serum of burn rats on the treated with during the 3minutes laser for 7 days were higher than those of burn and 4.5 minutes laser groups. There were significantly decreased the change of the level of immunoglobulin M(Ig M) in serum of burn rats on the treated with 3 minutes laser for 7 days to the control group, but were significantly increased on the 3minutes and 4.5 minutes laser groups for 21 days to the those of burn and control groups, and the levels of the Ig M on the 3minutes laser group for 21 days were higher than those of 7 days. The concentrations of immunoglobulin E(Ig E) in serun of the burn rats on the experimental and burn groups were significantly lower than those in control group. As above results, The changes of the level of immonoglobulin components in serum have meaningful role in the healing process on the treated with the low pewer intensity of HE-Ne IR laser.

  • PDF

Multiple crack evaluation on concrete using a line laser thermography scanning system

  • Jang, Keunyoung;An, Yun-Kyu
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.201-207
    • /
    • 2018
  • This paper proposes a line laser thermography scanning (LLTS) system for multiple crack evaluation on a concrete structure, as the core technology for unmanned aerial vehicle-mounted crack inspection. The LLTS system consists of a line shape continuous-wave laser source, an infrared (IR) camera, a control computer and a scanning jig. The line laser generates thermal waves on a target concrete structure, and the IR camera simultaneously measures the corresponding thermal responses. By spatially scanning the LLTS system along a target concrete structure, multiple cracks even in a large scale concrete structure can be effectively visualized and evaluated. Since raw IR data obtained by scanning the LLTS system, however, includes timely- and spatially-varying IR images due to the limited field of view (FOV) of the LLTS system, a novel time-spatial-integrated (TSI) coordinate transform algorithm is developed for precise crack evaluation in a static condition. The proposed system has the following technical advantages: (1) the thermal wave propagation is effectively induced on a concrete structure with low thermal conductivity of approximately 0.8 W/m K; (2) the limited FOV issues can be solved by the TSI coordinate transform; and (3) multiple cracks are able to be visualized and evaluated by normalizing the responses based on phase mapping and spatial derivative processes. The proposed LLTS system is experimentally validated using a concrete specimen with various cracks. The experimental results reveal that the LLTS system successfully visualizes and evaluates multiple cracks without false alarms.

A Study on High-precision Autofocus Matching Device for Smoke Detector Based on IR Laser (IR 레이저 기반 연기감지기를 위한 고정밀 자동초점 정합장치에 관한 연구)

  • Kim, Gwan-Hyung;Shin, Dong-Suk;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2759-2764
    • /
    • 2014
  • Smoke detector is commonly used to reduce fire detection time. However, technical problems regarding its inaccuracy of laser beam-receiving point on the surface of the sensor associated with incoming interference are identified when the laser transmitter and receiver are installed at a distance of about 100m. In this paper, we propose the auto focus alignment algorithm with high precision to adjust tilting angle of lasers caused by environmental interference so that solve existing issues using multi-level worm gear set.

The Effects of the Low Power Wavelengths of Helium-Neon Infra-Red Laser on the Changes of the Serum Mineral Components in Burn Rats (저 에너지 레이저 파장이 화상쥐 혈청 무기질 성분 변화에 미치는 영향)

  • Rho Min-Hee;Lee Hyun-Ok;Yong Joon-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.1-6
    • /
    • 2000
  • This studies were to investigate the effects of low power wavelengths Helium-Neon Infra-Red(He-Ne 1R) laser on the changes of the serum mineral components in burn rats. The thirty Spraque-Dawley adult male rats were assigned to the 5 groups: the experimental groups(3), the bum control group (1) and the control group(1). There was made three degree bum by the 250mW IR on the back of each rats. from 3 days after being burned. the experimental laser groups were irradiated low power wavelengths(292 Hz. 1168Hz, 4672Hz) He-He IR laser far 5 minutes every day during the 7 days. The results were as tallows: 1. There were significantly not changes of the levels of serum sodium between all experimental groups. 2. The concentration of potassium in serum on the treated with 292Hz wavelengths group during 5 minutes were significantly increased ,but with 1168Hz wavelenghths group were decreased to the those of burn group. 3. The concentrations of serum calcium in serum 1168Hz wavelengths laser group on the treated with 5 minutes laser were significantly higher to normal level than those of bum groups. As above results. the changes of the 2 essentials mineral(calcium and potassium) in serum levels on the healing process have meaningful effected with the low power wavelengths role on the treated with He-Ne IR laser.

  • PDF

Design of IR laser-based High-precision Automatic Focus Alignment (IR 레이저 기반 고정밀 자동 초점 정합장치 설계)

  • Jeon, Jae-Hwan;Kim, Myeong-Ho;Kim, Gwan-Hyung;Oh, Am-Suk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.07a
    • /
    • pp.427-428
    • /
    • 2014
  • 화재발생 시 인명 안전을 위하여 초기의 화재감지가 매우 중요한 요인이다. 기존 연기감지기의 경우 일정한 조건만 맞으면 작동하기 때문에 비화재보의 우려가 높다. 특히 차량 매연도 연료가 연소되어 나오는 연기이므로 차량정체 시 트럭 등에서 발생하는 심한 매연에도 반응하여 오작동의 가능성이 높다. 이러한 기존 화재감지기의 문제점을 해결하기 위해 다양한 IR 레이저 기반 연기검출장치가 활용되고 있다. 하지만 IR 레이저 기반 연기검출장치는 100m 거리가 이격된 레이저 발광부와 수광부 구조에 따라 발광부 레이저광선의 각도변화에 따른 수광부 레이저 포인트 위치가 매우 민감하게 변화함에 따라 초기 레이저 포인트의 초점을 정확히 정합하고, 이후 보정하기 위한 고정밀 자동 초점 정합장치가 필요하다. 이에 본 논문에서는 레이저 투광부와 수광부를 분리하여 레이저 송신기, 수신기로 구성되는 고정밀 자동초점 정합장치를 설계하고자 한다.

  • PDF