• Title/Summary/Keyword: IR Laser

Search Result 200, Processing Time 0.028 seconds

New CO Laser Technology Offers Processing Benefits

  • Held, Andrew
    • Laser Solutions
    • /
    • v.18 no.3
    • /
    • pp.9-13
    • /
    • 2015
  • The development of a reliable, high-power source of mind-IR laser light gives process develop important tool with unique characteristics that will significantly impact a diverse range of applications.

Infrared Dual-field-of-view Optical System Design with Electro-Optic/Laser Common-aperture Optics

  • Jeong, Dohwan;Lee, Jun Ho;Jeong, Ho;Ok, Chang Min;Park, Hyun-Woo
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.241-249
    • /
    • 2018
  • We report a midinfrared dual-field-of-view (FOV) optical system design for an airborne electro-optical targeting system. To achieve miniaturization and weight reduction of the system, it has a common aperture and fore-optics for three different spectral wavelength bands: an electro-optic (EO) band ($0.6{\sim}0.9{\mu}m$), a midinfrared (IR) band ($3.6{\sim}4.9{\mu}m$), and a designation laser wavelength ($1.064{\mu}m$). It is free to steer the line of sight by rotating the pitch and roll axes. Our design co-aligns the roll axis, and the line of sight therefore has a fixed entrance pupil position for all optical paths, unlike previously reported dual-FOV designs, which dispenses with image coregistration that is otherwise required. The fore-optics is essentially an achromatized, collimated beam reducer for all bands. Following the fore-optics, the bands are split into the dual-FOV IR path and the EO/laser path by a beam splitter. The subsequent dual-FOV IR path design consists of a zoom lens group and a relay lens group. The IR path with the fore-optics provides two stepwise FOVs ($1.50^{\circ}{\times}1.20^{\circ}$ to $5.40^{\circ}{\times}4.32^{\circ}$), due to the insertion of two Si lenses into the zoom lens group. The IR optical system is designed in such a way that the location and f-number (f/5.3) of the cold stop internally provided by the IR detector are maintained when changing the zoom. The design also satisfies several important performance requirements, including an on-axis modulation transfer function (MTF) that exceeds 10% at the Nyquist frequency of the IR detector pitch, with distortion of less than 2%.

Half mJ Supercontinuum Generation in a Telecommunication Multimode Fiber by a Q-switched Tm, Ho:YVO4 Laser

  • Zhou, Renlai;Ren, Jiancun;Lou, Shuli;Ju, Youlun;Wang, Yuezhu
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.7-12
    • /
    • 2015
  • Up to ${\sim}520{\mu}J$ broadband mid-infrared (IR) supercontinuum (SC) generation in telecommunication multimode fiber (MMF) directly pumped by a $2.054{\mu}m$ nanosecond Q-switched Tm, $Ho:YVO_4$ laser is demonstrated. An average output power of 3.64 W is obtained in the band of ~1900 to ~2600 nm, and the corresponding optic-to-optic conversion efficiency is 67% by considering the coupling efficiency. The spectrum has extremely high flatness with negligible intensity variation (<2%) in the wavelength interval of ~2070 to ~2475 nm. The SC long-wavelength edge is limited by the silicon glass material loss, and by optimizing the MMF length, the SC spectrum could extend out to ${\sim}2.6{\mu}m$. The output SC pulse shapes are measured at different output powers, and no splits are found. The SC laser beam is nearly diffraction limited with an $M^2=1.15$ in $2.1{\mu}m$ measured by the traveling knife-edge method, and the laser beam spot is monitored by an infrared vidicon camera.

The Studies of the low power Wavelengths of He-Ne IR laser on the changes of the serum biochemical components in burn rats (저 출력 레이저 파장에 따른 화상 쥐 혈청 생화학 성분 변화에 대한 연구)

  • Rho, Min-Hee;Kim, Eun-Young;Yong, Joon-Hwan
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.1
    • /
    • pp.17-24
    • /
    • 2002
  • This studies were to investigate the effects of low power wavelengths Helium-Neon Infra-Red(He-Ne IR)laser on the changes of the blood biochemical components in burn rats. The thirty Spraque-Dewely adult male rats were assigned to the 5 groups; the experimental groups(3), the burn control group(1) and the control group(1). There was made three degree burn by the 250mW IR on the back of each rats, from 3 days after being, burned, the experimental laser groups were irradiated low power wavelengths (292Hz, 1168Hz, 4672Hz) He-Ne IR laser for 5 minutes every day during the 7days. The results wee as follows: The activities of aspirate aminotransferase(AST), alanine aminotransferase(ALT), and lactate dehydrogenase(LDH), on treated with the wavelengths ((292Hz, 1168Hz, 4672Hz) laser groups during 5 min. for 7 days were significantly increased to the control group respectively, but those of total cholesterol(CHOL) and alkaline phosphatase(ALP) were significantly decreased to the a control group (p<0.05). there were significantly decreased on the activity of alanine aminotransferase and alkaline phosphatase on the all experimental groups to the burn control group and those of lactate dehydronase on treated with 292Hz and 4672Hz wavelength9 groups to the burn control group but, were significantly increased on those of urea nitrogen (292Hz and 1168Hz)(p<0.05). The activity of AST, LDH, on treated with 1168Hz wavelengths were significantly decreased of the 292Hz and 4672Hz wavelengths groups that of ALT on the treated with 1168Hz group was significantly increased to the 4672 Hz wavelength group but those of CHOL and LDH on the 1168Hz and 4672Hz wavelength groups were dignificatly decreased to the MHz wavelengths group. As above results, the changes of the activities of biochemical conponents in the serum levels on the healing process have meaningful effected of the role of low power wavelengths He-Ne IR laser.

  • PDF

Blind via Hole manufacturing technology using UV Laser (UV 레이저에 의한 블라인드 비아홀 가공)

  • 장정원;김재구;신보성;장원석;황경현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.160-163
    • /
    • 2002
  • Micro via hole Fabrication is studied by means of minimizing method to circuit size as many electric products developed to portable and minimize. Most of currently micro via hole fabrication using laser is that fabricate insulator layer using CO2 Laser after Cu layer by etching, or fabricate insulator layer using IR after trepanning Cu by UV. In this paper, it was performed that a metal layer and insulator layer were worked upon only one UV laser, and increase to processing speed by experiment.

  • PDF

Effects of the He-Ne IR Laser Irradiation and Neuromuscular Electrical Stimulation on the Change of the Serum Biochemical Components in the Experimentally Induced Muscle Injured Rats

  • Kim, Jong-Soon;Rho, Min-Hee;Kim, Jae-Young
    • Biomedical Science Letters
    • /
    • v.13 no.3
    • /
    • pp.223-230
    • /
    • 2007
  • Low power laser and neuromuscular electrical stimulation have been utilized in many clinical applications for the treatment of musculoskeletal lesion. This study was to investigate the effects of low power He-Ne IR laser and neuromuscular electrical stimulation on the change of the serum biochemical components in experimentally induced muscle injured rats. The twenty Sprague-Dawley male rats were randomly assigned to the 4 groups: the normal group (n=5), the control group (n=5), the low power laser irradiation group (LLI) (n=5) and the neuromuscular electrical stimulation group (NMES) (n=5). The experimentally induced muscle injury was induced by the subcutaneous injection of a 0.1 ml Freund's Complete Adjuvant into the right hind paw and calf muscles in control, LLI and NMES groups. The LLI group was irradiated with He-Ne IR laser for 5 minutes every day during 10 days. Also, the NMES group was electrically stimulated 15 minutes every day during 10 days. The normal and control groups were not received with any therapeutic intervention. The authors performed tests which were the concentration of the serum biochemical components to detect the effects of therapeutic interventions. The results were as follows: 1. The level of the aspartate aminotransferase (AST) was significantly decreased in the LLI and NMES groups compare to the control group. 2. The level of the serum lactate dehydrogenase (LDH) was significantly decreased in the LLI and NMES groups compare to the control group. 3. The level of the serum creatine kinase (CK) was significantly decreased in the LLI and NMES groups compare to the control group. From the results, we could come to the conclusion that low power laser and neuromuscular electrical stimulation could be accelerating healing processes of skeletal muscle injury and further clinical work will be required.

  • PDF

Slotted type copper ion laser (Slot형 구리 이온 레이저)

  • 송순달;홍남관
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.291-296
    • /
    • 1997
  • The slotted type of hollow copper cathode was constructed and tested for its geometric stability and usability for laser operation at 780nm. The peak output power of copper ion laser emission was measured for different operating conditions. The IR-laser power was dependent on the parameters of the geometry of the hollow cathodes, discharge current and gas fillings. The peak power decreased with increasing neon pressure over 60%. One reason for this decrease in output power may be conjectured as hier due to the decreasing population of the upper laser level. The copper ion laser transition at 780 nm populated at the 5p level. The hollow cathode copper ion laser is operated in He and Ne mixture by electric discharge excitation and could be operated for more than 100 hours with only a 35% drop in the output power(2.8mW cw for 9.6cm active length).

  • PDF

Monitoring of Silicon Wafer Temperature by IR Laser Interfermetry (적외선 레이저의 간섭현상을 이용한 실리콘 웨이퍼의 온도 측정)

  • 김재성;이석현;황기웅
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.2
    • /
    • pp.81-87
    • /
    • 1994
  • We used IR laser inteferometric technique for measuring the temperature of wafer during cryogenic ECR etching. Using this technique, the effect of RF bias power and microwave power on the wafer temperature during etching period is investigated. As the RF bias power and microwave power was increased, the temperature of the wafer considerably increased and we concluded that to prevent the increase of substrate temperature during etching period, an adequate wafer cooling is needed.

  • PDF

Automatic FOD Detection Test Using EO/ IR Laser Light Camera (EO / IR Laser Light 카메라를 이용한 FOD 자동탐지 시험)

  • Shin, Hyun-Sung;Hong, Gyo-Young;Hong, Jae-Beom;Choi, Young-Soo;Kim, Yun-Seob
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.638-642
    • /
    • 2017
  • FOD is a generic term for substances with potential threats that can pose a fatal risk to aircraft. Therefore, FOD should be noted in all areas of the airport. Especially, the method of detecting and collecting FOD in runway and aircraft movements is very low efficiency and economical efficiency of airport operation, so it is essential to develop FOD automatic detection system suitable for domestic environment. As part of the aviation safety technology development project, the development of an automatic detection system for foreign matter in the moving area of the aircraft inside the airport is underway. In this paper, it is confirmed that EO / IR camera is used for detection of foreign objects at Taean Airfield of Hanseo University. EO camera is used during the day and IR camera is used at night.

The Effect of He-Ne IR Laser Therapy on The Healing of Acute Septic Knee Arthritis in Rat (흰쥐의 화농성 슬관절염 치유에 He-Ne IR레이저 처치의 효과)

  • 김재영;노민희;고진복
    • Biomedical Science Letters
    • /
    • v.6 no.3
    • /
    • pp.223-228
    • /
    • 2000
  • The purpose of this study was to find out the effect of He-Ne, IR laser therapy for 4 and 10 minutes on healing of septic arthritis. Sprague-Bawley rats (212.1$\pm$10 g) were randomly assigned to one control and three arthritis groups. Septic arthritis groups were divided into arthritis control, 4 or 10 minute laser therapy groups. Arthritis was experimentally induced by intraperitoneally administration of staphylococcus aureus in citrate buffer(pH 4.3). These result were obtained as follows: AST, LDH, ALP, CK activities and IgG concentration in 10 minute laser group were signifantly increased compare with those in the arthritis group. AST, LDH and CK activities in 4 minute laser group were significantly decreased compare with those in the arthritis group. We think that laser therapy in 4 minute may effective on the healing of septic arthritis. And we will have to study of the effect of laser therapy on healing mechanism, appropriate time of septic arthritis.

  • PDF