• Title/Summary/Keyword: IP 노출

Search Result 71, Processing Time 0.023 seconds

Geometric Region Reconstruction of Steel-tube Computed Radiography Using Nonlinear Structural Analysis (비선형 구도해석에 의한 강관 CR영상의 기하학적 영역복원)

  • Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.6
    • /
    • pp.146-152
    • /
    • 2009
  • The steel-tube is exposed to a radiation from X-ray source. The transmitted radiation is detected by a detector, usually film or more recently an imaging plate(IP) of Computed Radiography(CR). The detected radiation overlaps the region of both sides of the object. The radiographic images reflect the projections of the rays, passing twice through both external and internal tube material. Nonlinear distortion due to the radioactive transmission and geometric disposition also appears on images. In this paper, an analytical approach is presented to achieve image reconstruction from the steel-tube CR images. Parameters related to radiation and measuring structure, such as intensities, absorption in material and geometric specifications linked with the collimating components, are calculated and identified in order to construct the renoval images for twofold regions of circle-type steel tubes. A correction procedure for region recovery most similar to the true tube is designed. The application of this approach on CR images is shown and reconstructed results are discussed.

Study on Collecting Server Information through Banner Grabbing (배너 그래빙을 통한 서버 정보 수집에 관한 연구)

  • Kang, HongGoo;Kim, HyeonHak;Lee, HyunSeung;Lee, Sang-jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.6
    • /
    • pp.1317-1330
    • /
    • 2017
  • To collect server information and construct network map enable us to prevent security breach, prepare for national cyber warfare and make effective policies. In this paper, we analyze well-known network scanners, Nmap and ZMap, and construct network map using banner grabbing. We use multiple threads in order to increase scanning speed and arrange IP lists by specific order to reduce the load on information gathering targets. Also, we applied performance tests to compare the real-time banner grabbing tool with the existing network scanners. As a result, we gathered server information from domestic and overseas servers and derived a risk index based on the collected database. Although there are slight differences among countries, we can identify the risky situation that many users in every country are exposed to several security breaches.

Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species (Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1))

  • Song, Jung Il;Kim, Han Seul
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.220-231
    • /
    • 2021
  • The use of digital copies of film-based analog images and the introduction of digital radiographic imaging systems using image plates gradually replace the non-destructive radiationirradiation method of Cultural Heritage. The quality of images obtained from this technique is affected by conditions such as tube voltage, tube current, and exposure time, type of image acquisition medium, distance of the artifacts from the image acquisition medium, and thickness of artifacts. In this study, we evaluated the grayscale image obtained using GE's Computed Radiograhpy (CR) imaging system, the transmission characteristics of the X-ray source for each tree type (pine, chestnut, sawtooth oak, ginkgo) used in wooden Cultural Heritage, and the signal-to-noise ratio (SNR) and contrast. The GE's CR imaging were analyzed using the Duplex wire image quality indicator, line-pair gauges.

The specific antibody response of olive flounder Paralichthys olivaceus to route of antigen administration and change in environmental conditions (항원의 투여방법 및 사육환경 변화에 따른 넙치의 특이항체 반응)

  • Kim, Wi-Sik;Han, Jong-Seok;Jang, Min-Seok;Seo, Han-Gil;Jung, Sung-Ju;Park, Jung-Jun;Kim, Seok-Ryel;Oh, Myung-Joo
    • Journal of fish pathology
    • /
    • v.24 no.2
    • /
    • pp.153-160
    • /
    • 2011
  • The specific antibody response of olive flounder, Paralichthys olivaceus to change in rearing-environmental conditions post immunization with antigen (bovine serum albumin, BSA) and different routes of antigen administration were investigated by enzyme-linked immunosorbent assay (ELISA). To test the effect of routes of antigen administration, flounder were injected intraperioneally or intramuscularlly with 1 mg of BSA. In addition, to test the effect of change in environmental condition post immunization, flounder were injected intraperioneally with 1 mg of antigen, and then were exposed to acute thermal change (the water temperature (WT) was decreased from $21^{\circ}C$ to $15^{\circ}C$ within 30 min and maintained at $15^{\circ}C$ for 3 h), handling (fish were caught and subsequently held out of water for 1 min) or heavy oil (76 g/200 L for 2 days). Consequently, there was no significant difference between intraperioneal (IP) and intramuscular (IM) injections except at 10 days post-immunization. With these results, it suggests that both 1M and IP injections may be used as route of vaccination. Furthermore, no significant difference was observed in the antibody response among the groups exposed to heavy oil, handling, sudden drop of WT and positive control except at 10 days post-immunization. From these results, it was confirmed that specific antibody response was not affected by the above mentioned rearing-environmental conditions, suggesting that vaccination can be employed at changing rearing-environmental conditions.

Antinociceptive Effect of Testosterone in Androgenized Female Mice (남성화된 암컷 생쥐에서 Testosterone이 통각예민도에 미치는 영향)

  • Chon, Myong-Ho;Kim, Myung-Jung;Park, Je-Min;Yang, Gu-Beum;Lee, Kook-Hee;Jang, Sae-Heon;Kang, Cheol-Joong
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.8 no.1
    • /
    • pp.65-71
    • /
    • 2000
  • Objects : Aimed to test the hypothesis that neonatal testosterone exposure in female mice influences the development of testosterone-related pain inhibitory system and that testosterone administered in adulthood decreases the pain sensitivity. Methods : Thirty androgenized(testosterone propionate $100{\mu}g$ ip within 24 hrs after birth) adult female and twenty five control(normal saline $100{\mu}g$ ip within 24 hrs after birth) adult female mice were injected with testosterone propionate 1mg/kg/day for 3 consecutive days from 84th experimental days. Nociceptive sensitivity was measured before and after treatment of testosterone by tail flick latency on 84th and 86th experimental days. Results : 1) On the 84th experimental day, basal nociceptive sensitivity was significantly higher in the androgenized group($2.7{\pm}0.4$ sec) as compared to the control group($3.3{\pm}1.1$ sec). 2) Testosterone treatment on the 84th experimental day significantly lowered nociceptive sensitivity in both androgenized($5.2{\pm}0.9$ sec) and control groups($4.6{\pm}1.8$ sec). However the effect was significantly greater in the androgenized group. 3) Nociceptive sensitivity on 86th experimental day before administration of testosterone was significantly lower in the androgenized group($4.8{\pm}1.9$ sec) as compared to the control group($3.9{\pm}1.2$ sec). 4) Testosterone treatment on the 86th experimental day significantly lowered the nociceptive sensitivity in both groups, but the androgenized group($5.9{\pm}0.9$ sec) showed significantly lower post-treatment nociceptive sensitivity as compared to the control group($4.9{\pm}1.5$ sec). 5) Nociceptive sensitivity was decreased significantly after injection of testosterone once a day for two consecutive days in the androgenized group(${\Delta}2.1{\pm}1.0$ sec), but not in the control group(${\Delta}0.5{\pm}1.3$ sec). Conclusions : There may be a testosterone-related pain inhibitory system, the development of which is enhanced by exposure to testosterone in the neonatal period, and the activity of which is also mediated by testosterone in the later life.

  • PDF

The effects of various exposure times in the detectability on the tips of the endodontic files in Digora$\textregistered$ (Digora$\textregistered$에서 노출시간의 변화가 근관치료용 file의 첨부식별에 미치는 영향)

  • Ko Jee-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.55-71
    • /
    • 1997
  • Digora/sup (R)/ an intraoral digital radiography system utilizing image plate (IP) - has a dynamic range of exposure time which allows it to decrease the patient's exposure time and to increase diagnostic ability through image processing, transmission and storage. The purpose of this study was to evaluate the Digora/sup (R)/ system by assessing the effects of various exposure times on the detectability on the tip of the endodontic file. Examining the root canals of 45 extracted sound premolars, K -files No. 10, 15, and 20 were placed at slightly varying distances from the apex. The teeth were glued onto resin-plaster blocks. Five exposure times varying between 0.01 seconds and 0.25 seconds were used. Four observers were asked to measure the distance between the tip of the file and a reduction of crown portion, and obtained mean errors (subtracting true file length from the measured file length), comparing Digora/sup (R)/ monitors with E-plus films, which were both obtained under the same geometrical positions. The results were as follows : 1. Comparing E-plus film with Digora/sup (R)/ at 0.01 seconds, the mean errors in E-plus film showed -4.453 nun, -4.497 nun, and -3.857 nun, while the mean errors in Digora/sup (R)/ showed 0.065 nun, 0.607 nun, and 0.719 mm according to the file groups. Therefore there was a significant difference between E-plus film and Digora/sup (R)/(p<0.05). 2. By comparison of mean errors according to the various exposure times in the Digora/sup (R)/ system, the mean error at 0.01 seconds was significantly lower than that at 0.12 and 0.25 seconds in the No. 10 file group(p<0.05). And the standard deviation was the highest at 0.01 seconds. 3. Comparing E-plus film at 0.25 seconds with the Digora/sup (R)/ system, the mean errors showed a significant difference between E-plus film at 0.25 seconds and the Digora/sup (R)/ system at 0.25 seconds in No. 10 and 20 file groups(p<0.05). 4. Comparing E -plus film at 0.25 seconds with other exposure times, the mean errors showed a significant difference between E-plus film at 0.25 seconds and E-plus film at 0 .. 01 and 0.03 seconds in 10 file group(p<0.05). In the No. 15 and 20 file groups, there was a significant difference between E-plus film at 0.25 seconds and E-plus film at 0.01 seconds(p<0.05). In conclusion, Digora/sup (R)/ was better than E-plus film in detectability on the tip of the file at the exposure time of 0.01 seconds in all file groups. And we concluded that Digora/sup (R)/ can shorten exposure times up to 4% of 0.25 seconds (0.01 sec), which is adequate exposure time for premolar in E-plus film using No. 15 and 20 files.

  • PDF

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.

A Visual Image Analysis of Byungsan-seowon by an Attribute of View (조망지향 속성에 따른 병산서원의 경관이미지 특성)

  • Huh, Joon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.4
    • /
    • pp.86-93
    • /
    • 2009
  • This study analyzes the systematic visual images and factors in and outside of the main courtyard in Byungsan-seowon. The results are as follows; In terms of space distribution, Ip-kyo-dang is located at an elevation of 85m and the distance to Byung-san is 365m. Byung-san with the mean gradient over $50^{\circ}$ looked so stiff, and the east side of that cliff is higher than west. In terms of the angle of elevation relationship between Man-dae-ru and Byung-san draw 10.5 degree and it suits with human scale. The D/H ratio of 1:3 makes the given place very spacious but the linear stiff shape of Byung-san may cause the feeling of closeness. The results of the visual image analysis of the main yard facing Byung-san is very positive with a score of 1.70 in openness, 1.78 in wideness, 1.96 in beauty, 1.96 in harmony for the spacious arrangement which overall, makes the seowon beautiful with many open spaces. There are 4 main implicated factors analyzed which are uniqueness, aesthetic, openness and nature. Out of the total variables, these factors' descriptive ability is 55.90% and the remaining 44.10% is error and peculiarities variables. The factor which contributed most to Byungsan-seowon's main yard's visual preference was the 'aesthetic' with B-values of 0.661 and 0.455 in the nature category.

Do Paneth Cells Regulate the Zinc Body Burden? (Zinc 대사와 관련된 Paneth 세포활성의 변화에 관한 조직화학적 연구)

  • Jo, Seung-Mook;Kim, Sung-Jun;Park, Seung-Kook;Kang, Tae-Cheon;Won, Moo-Ho
    • Applied Microscopy
    • /
    • v.30 no.4
    • /
    • pp.357-365
    • /
    • 2000
  • Paneth cells have been suggested to contribute to the elimination of excess metals into the intestinal lumen. The purpose of this study wat to investigate the changes of the zinc pools in rats subjected to functional loading with zinc salt by mean of both light and electron microscopical autometallography (AMG). Wistar rats 4 were administrated with zinc chloride (20 mg/kg body weight) intraperitoneally dissolved in 1 ml distilled water. The control group received 1 ml saline IP. After further one hour the animals were transcardially perfused with 0.4% sodium sulphide dissolved in 0.1 M PB fellowed by 3% glutaraldehyde solution for 10 minutes. Pieces of ileum were frozen with solid $CO_2$ and sectioned on a cryostat. The sections $(20{\mu}m)$ were autometallographically developed. Sections selected for EM were reembedded on top of a blank Epon block, from which ultrathin sections (100 nm) were cut. The ultrathin sections were double stained with uranyl acetate (30 min) and lead citrate (5 min), then examined under electron microscope. Studies of comparable sections from control and zinc loaded animals with the AMG selenium method gave quite different results. The control animals demonstrated a weakly positive staining in the cytoplasm of the Paneth cells. In the electron microscope the AMG silver grains were found to be located in the cytoplasm, while the electron dense secretary granules and other cell organelles were void of staining. Few AMG grains were located at the apical surface of the Paneth cells. In sections from zinc loaded rats, the AMG grains were seen in abundance in the lumen of the Lieberkuhn crypts at light microscopic levels. At EM levels the zinc revealing silver grains were located in the cytoplasm as in the controls, but much more AMG grains were shifted into the secretary granules. Furthermore, profound AMG grains were found in the lumen of the crypts and surrounding vessels. And a few grains were seen in the endothelium. The AMG technique demonstrated a pattern of AMG grains in the Paneth cells that strongly suggests a transport of zinc ions through these cells.

  • PDF

Comparison of Average Glandular Dose in Screen-Film and Digital Mammography Using Breast Tissue-Equivalent Phantom (유방조직등가 팬텀을 이용한 Screen-Film과 Digital Mammography에서의 평균 유선선량)

  • Shin, Gwi-Soon;Kim, Jung-Min;Kim, You-Hyun;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.13-23
    • /
    • 2007
  • In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate(IP). We measured average glandular doses(AGD) in screen-film mammography(SFM) system with slow screen-film combination, computed mammography(CM) system, indirect digital mammography(IDM) system and direct digital mammography(DDM) system using brest tissue-equivalent phantom(glandularity 30%, 50% and 70%). The results were shown as follows : AGD values for DDM system were highest than those for other systems. Although automatic exposure control(AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter(Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in oder to estimate a patient radiation dose.

  • PDF