• Title/Summary/Keyword: IOP sensor

Search Result 11, Processing Time 0.024 seconds

Design of a Wireless Intraocular Pressure Sensor Based on MEMS Technology (안압의 비접촉 검출을 위한 MEMS 기반의 센서 설계)

  • Kang, Buung-Joo;Park, Jong-Hoon;Lee, So-Hyun;Kang, Ji-Yoon;Park, Chang-Kun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.905-912
    • /
    • 2011
  • Interaocular pressure (IOP) sensor and external coil to detect the resonance frequency of the IOP sensor are designed and implemented using MEMS technology. The IOP sensor is designed using 3-D electromagnetic (EM) simulation. The resonance frequency of IOP sensor needs to be lower than that of the external coil. Additionally, the resonance frequency of the IOP sensor needs to be located near the resonance frequency of the coil to get the sufficient amplitude of phase variation. The frequency where the phase peak appears must be constant according to the distance between the IOP sensor and the external coil. From the measurement results, we demonstrated that the designed IOP sensor has the same resonance frequency with various distances between the IOP sensor and the coil.

Development of Inductive and Capacitive Type Intraocular Pressure (IOP) Sensor to Improve Sensitivity and Minimize Size (민감도 향상과 센서 소형화를 위한 자기 및 용량형 안압센서의 개발)

  • Jang, Cheol In;Shin, Kyeong-Sik;Yun, Kwang-Seok;Kim, Yong Woo;Kang, Ji Yoon;Lee, Soo Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.409-415
    • /
    • 2014
  • We had presented an inductive type intraocular pressure sensor (L-sensor) in previous work. The distance between a micro coil and a ferrite on the membrane was modulated by pressure, and as a result the inductance and resonant frequency were changed. However, L-sensor has some problems to implant in eyes. First problem is low sensitivity. When L-sensor was implanted in rabbit's eyes, resonant frequency of L-sensor was very hard to detect. Second problem is biocompatibility. Size of L-sensor is $6{\times}7{\times}1.2mm$. When L-sensor was implanted in the eyes, it caused the inflammation. Therefore, this study suggests an inductive and capacitive type IOP sensor (LCsensor). The sensitivity of the LC-sensor 27.3 kHz/mmHg under 60mmHg. It is much larger than 14 kHz/mmHg of the L-sensor. And the size of LC-sensor is 47% smaller than L-sensor. After 2 weeks from the implantation of LC-sensor into rabbit eyes, we measured the changes of resonant frequency of LC-sensor according to increased IOP by Balanced Salt Solution (BSS) injection. As a result, the sensitivity of LC-sensor in in vivo test is 25 kHz/mmHg. That is similar to the sensitivity of in vitro test.

A Wireless Intraocular Pressure Sensor with Variable Inductance Using a Ferrite Material

  • Kang, Byungjoo;Hwang, Hoyong;Lee, Soo Hyun;Kang, Ji Yoon;Park, Joung-Hu;Seo, Chulhun;Park, Changkun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.4
    • /
    • pp.355-360
    • /
    • 2013
  • A wireless intraocular (IOP) pressure sensor based on micro electro mechanical system (MEMS) technology is proposed. The proposed IOP sensor uses variable inductance according to the external pressure. The proposed sensor is composed of two flexible membranes: a ferrite bottom part, an inductor, and a capacitor. The inductance of the sensor varies according to the external pressure. The resonance frequency of the sensor is also varied, and this frequency is detected using an external coil. The external coil is designed with an FR-4 printed circuit board. The feasibility of the proposed sensor structure using variable inductance to detect the external pressure is successfully demonstrated.

A New Valve Actuator for a Glaucoma Treatment by Using MEMS

  • Byunghoon Bae;Kim, Nakhoon;Park, Kyihwan;Hongseok Kee;Kim, Seonho;Lee, Yeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.103.6-103
    • /
    • 2001
  • Glaucoma is an eye disease which is caused by abnormal high IOP (Intra Ocular Pressure) in the eye. High IOP is caused by the aqueous humor which is produced consistently but not drained due to the malfunction of the trabecular system which has a role of draining the aqueous humor into the venous system. Currently, there are some methods to treat glaucoma, Among these, the use of implants is increasing in these days due to many problems in other methods. However, conventional implants are passive implants and have critical disadvantage. Therefore, it is needed to develop a new implant using MEMS structure which is capable of controlling the IOP actively and copes with personal difference of patients. An active glaucoma implant consists of the valve actuator, pressure sensor, controller, and power supply. In this paper the valve actuator is considered. We make experiments and simulations with the fabricated ...

  • PDF

The Analysis of Changma Structure using Radiosonde Observational Data from KEOP-2007: Part I. the Assessment of the Radiosonde Data (KEOP-2007 라디오존데 관측자료를 이용한 장마 특성 분석: Part I. 라디오존데 관측 자료 평가 분석)

  • Kim, Ki-Hoon;Kim, Yeon-Hee;Chang, Dong-Eon
    • Atmosphere
    • /
    • v.19 no.2
    • /
    • pp.213-226
    • /
    • 2009
  • In order to investigate the characteristics of Changma over the Korean peninsula, KEOP-2007 IOP (Intensive Observing Period) was conducted from 15 June 2007 to 15 July 2007. KEOP-2007 IOP is high spatial and temporal radiosonde observations (RAOB) which consisted of three special stations (Munsan, Haenam, and Ieodo) from National Institute of Meteorological Research, five operational stations (Sokcho, Baengnyeongdo, Pohang, Heuksando, and Gosan) from Korea Meteorological Administration (KMA), and two operational stations (Osan and Gwangju) from Korean Air Force (KAF) using four different types of radiosonde sensors. The error statistics of the sensor of radiosonde were investigated using quality control check. The minimum and maximum error frequency appears at the sensor of RS92-SGP and RS1524L respectively. The error frequency of DFM-06 tends to increase below 200 hPa but RS80-15L and RS1524L show vice versa. Especially, the error frequency of RS1524L tends to increase rapidly over 200 hPa. Systematic biases of radiosonde show warm biases in case of temperature and dry biases in case of relative humidity compared with ECMWF (European Center for Medium-Range Weather Forecast) analysis data and precipitable water vapor from GPS. The maximum and minimum values of systematic bias appear at the sensor of DFM-06 and RS92-SGP in case of temperature and RS80-15L and DFM-06 in case of relative humidity. The systematic warm and dry biases at all sensors tend to increase during daytime than nighttime because air temperature around sensor increases from the solar heating during daytime. Systematic biases of radiosonde are affected by the sensor type and the height of the sun but random errors are more correlated with the moisture conditions at each observation station.

Development of Control Algorithm for Intersection Safety System Using the Fusion of V2X and Environmental Sensors (V2X 및 환경 센서 융합 기반 교차로 안전 시스템 알고리즘 개발)

  • Park, Manbok;Lee, Sanghyun;Jun, Sibum;Kee, Seokcheol;Kim, Jungbeom;Kee, Changdon;Kim, Kyuwon;Yi, Kyongsu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.5
    • /
    • pp.126-135
    • /
    • 2014
  • This paper describes the development and verification of control algorithms for V2X and environmental sensor integrated intersection support and safety systems. The objective of the research is to develop core technologies for effective fusion of V2X and environmental sensors and to develop new safety function for intersection safety. One of core technologies is to achieve the improvement of GPS accuracy, and the other is to develop the algorithm of a vehicle identification which matches all data from V2X, vehicle sensors and environmental sensors to specific vehicles. A intersection optimal pass (IOP) algorithm is designed based on these core technologies. IOP recommends appropriate speed to pass the intersection in the consideration of traffic light signal and preceeding vehicle existence. Another function is developed to prevent a collision avoidance when car crash caused by traffic violation of surrounding vehicles is expected. Finally all functions are implemented and tested in three test vehicles. It is shown that IOP can support convenient and comfortable driving with recommending optimal pass speed and collision avoidance algorithm can effectively prevent collision caused by traffic sign violation of surrounding vehicles.

Modeling and Design of an Active Pressure Regulating Valve(Implant) (녹내장 치료용 능동형 압력조절밸브(Implant) 모델링 및 설계)

  • Bae, Byunghoon;Kim, Nakhoon;Lee, Yeon;Kee, Hongseok;Kim, Seoho;Park Kyihwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.5
    • /
    • pp.805-815
    • /
    • 2001
  • Glaucoma is an eye disease which is caused by abnormal high IOP (Intra Ocular Pressure). High IOP is caused by the aqueous humor which is produced consistently but not drained due to malfunction of the trabecular system which has a role of draining the aqueous humor into the venous system. Currently, there are three methods to treat glaucoma-using medicines, surgical operation, and using implant device. The first and second methods are not long acting, so the use of implants is increasing in these days in order to drain out the aqueous humor compulsory. However, though conventional implants have a capability of pressure regulation, they cannot maintain IOPs desired for different patients, and too much aqueous humor are usually drained, to cause hypotony. To solve these problems, it is needed to develop a new implant which is capable of controling the IOP actively and copes with personal difference of patients. An active glaucoma implant consists of the valve actuator, pressure sensor, controller, and power supply. In this paper, firstly, we make an analysis of the operation of a conventional implant using a bond graph and show defects and limitations of the conventional valve analytically. Secondly, we design and analyze a valve actuator considering actuation principles, resistance elements, control methods, and energy sources focused on power saving problem. Finally, using simulations the possibility of the proposed valve actuator is investigated.

Atmospheric and BRDF Correction Method for Geostationary Ocean Color Imagery (GOCI) (정지궤도 해색탑재체(GOCI) 자료를 위한 대기 및 BRDF 보정 연구)

  • Min, Jee-Eun;Ryu, Joo-Hyung;Ahn, Yu-Hwan;Palanisamy, Shanmugam;Deschamps, Pierre-Yves;Lee, Zhong-Ping
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.175-188
    • /
    • 2010
  • A new correction method is required for the Geostationary Ocean Color Imager (GOCI), which is the world's first ocean color observing sensor in geostationary orbit. In this paper we introduce a new method of atmospheric and the Bidirectional Reflectance Distribution Function(BRDF) correction for GOCI. The Spectral Shape Matching Method(SSMM) and the Sun Glint Correction Algorithm(SGCA) were developed for atmospheric correction, and BRDF correction was improved using Inherent Optical Property(IOP) data. Each method was applied to the Sea-Viewing Wide Field-of-view Sensor(SeaWiFS) images obtained in the Korean sea area. More accurate estimates of chlorophyll concentrations could be possible in the turbid coastal waters as well as areas severely affected by aerosols.

STUDY ON THE DEVELOPMENT OF $a_{dom}$ ESTIMATION ALGORITHM BY EMPIRICAL METHOD FOR GOCI OCEAN COLOR SENSOR

  • Moon, Jeong-Eon;Ahn, Yu-Hwan;Ryu, Joo-Hyung;Choi, Joong-Ki
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.49-52
    • /
    • 2007
  • This study uses empirical method to estimate absorption coefficient of colored dissolved organic matter $(a_{dom})$ from GOCI satellite data with the relationship between band ratio of remote sensing reflectance $(R_{rs})$ and $a_{dom}$. For development of $a_{dom}$ estimation algorithm, the used data is in-situ data about ocean optical properties in the around seawater area of the Korean Peninsula during 1998 - 2005. The relationship of $R_{rs}$(412)/$R_{rs}$(555), $R_{rs}$(443)/$R_{rs}$(555), $R_{rs}$(490)/$R_{rs}$(555), $R_{rs}$(510)/$R_{rs}$(555) and $a_{dom}$(412) showed $R^2$ values of 0.707, 0.707, 0.597 and 0.552, respectively. The spectrum of $a_{dom}({\lambda})$ is shape of exponential function $a_{dom}({\lambda})$ value decreases with increasing wavelength. For estimation of $a_{dom}$ from satellite data, we developed an algorithm from the relationship of $a_{dom}$(412) and $R_{rs}$(412)/$R_{rs}$(555). This algorithm was employed on SeaWiFS imagery to estimate $R_{rs}$(412) in the South Sea, East Sea, Yellow Sea and northern East China Sea areas. Also, SeaDAS-derived $a_{dg}$(412) from same SeaWiFS imagery, These $a_{dg}$(412) was then compared with in-situ and empirical-algorithm-derived $a_{dom}$(412), but these values were different. We think two points that such different values are caused by discrepancy related to failure of standard atmospheric correction scheme, the other are caused by error related to definition of $a_{dom}$(412) and $a_{dg}$(412).

  • PDF

Sensitivity Analysis of Volcanic Ash Inherent Optical Properties to the Remote Sensed Radiation (화산재입자의 고유 광학특성이 원격탐사 복사량에 미치는 민감도 분석)

  • Lee, Kwon-Ho;Jang, Eun-Suk
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.47-59
    • /
    • 2014
  • Volcanic ash (VA) can be estimated by remote sensing sensors through their spectral signatures determined by the inherent optical property (IOP) including complex refractive index and the scattering properties. Until now, a very limited range of VA refractive indices has been reported and the VA from each volcanic eruption has a different composition. To improve the robustness of VA remote sensing, there is a need to understanding of VA - radiation interactions. In this study, we calculated extinction coefficient, scattering phase function, asymmetry factor, and single scattering albedo which show different values between andesite and pumice. Then, IOPs were used to analyze the relationship between theoretical remote sensed radiation calculated by radiative transfer model under various aerosol optical thickness (${\tau}$) and sun-sensor geometries and characteristics of VA. It was found that the mean rate of change of radiance at top of atmosphere versus ${\tau}$ is six times larger than in radiance values at 0.55 ${\mu}m$. At the surface, positive correlation dominates when ${\tau}$ <1, but negative correlation dominates when ${\tau}$ >1. However, radiance differences between andesite and pumice at 11 ${\mu}m$ are very small. These differences between two VA types are expressed as the polynomial regression functions and that increase as VA optical thickness increases. Finally, these results would allow VA to be better characterized by remote sensing sensors.