• Title/Summary/Keyword: IOP

Search Result 97, Processing Time 0.02 seconds

Comparison of Intraocular Pressure Values of Normotensive and Glaucomatous Rats Using Two Types of Tonometers (두 종류의 안압계로 측정한 정상안압과 녹내장 쥐의 안압 값 비교)

  • Choy, Yoon-Jung;Choi, Jee-Hyun
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.589-596
    • /
    • 2018
  • Purpose : We compared intraocular pressure (IOP) values measured by two types of tonometers in condition of normotensive and glaucomatous rat model. We tried to determine which of tonometer can more easily and accurately measure the IOP of animal model. Methods : Glaucomatous eyes were induced by intracameral injections of hyaluronic acid in right eyes of six-week-old male Spargue-Dawley (SD) rats. Normotensive contralateral eyes were left eyes of the SD rats. IOP was measured using a rebound tonometer (Tonolab) and a immersive tonometer ($Tonopen^{(R)}$ XL) about 3:00 pm. Results : The mean IOP values of normotensive control eyes were $10.80{\pm}1.03mmHg$ by Tonopen, and $15.10{\pm}0.73mmHg$ by Tonolab. They were statistically insignificant (p = .1). The mean IOP values of glaucomatous experimental eyes were $30.20{\pm}2.67mmHg$ by Tonopen, and $37.90{\pm}2.73mmHg$ by Tonolab. They were statistically insignificant (p = .95). High IOP values of glaucomatous eyes by two types of tonometers had strong positive correlation each other (r = .904, p < .01). Conclusion : This is the first study to compare IOP values using two types of tonometers between normotensive and glaucomatous model made by intracameral injection of hyaluronic acid. Tonopen should be used carefully when the IOP is within normal range, and both Tonopen and Tonolab can be used reliably when the IOP is high.

ESTIMATION OF IOP FROM INVERSION OF REMOTE SENSING REFLECTANCE MODEL USING IN-SITU OCEAN OPTICAL DATA IN THE SEAWATER AROUND THE KOREA PENINSULA

  • Moon, Jeong-Eon;Ahn, Yu-Hwan;Ryu, Joo-Hyung;Yang, Chan-Su
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.224-227
    • /
    • 2006
  • For estimation of three inherent optical properties (IOPs), the absorption coefficients for phytoplankton ($a_{ph}$) and suspended solid particle ($a_{ss}$) and dissolved organic matter ($a_{dom}$), from ocean reflectance, we used inversion of remote sensing reflectance model (Ahn et al., 2001) at this study. The IOP inversion model assumes that (1) the relationship between remote sensing reflectance ($R_{rs}$) and absorption (a) and backscattering ($b_{b}$) is well known, (2) the optical coefficients for pure water ($a_{w}$, $b_{bw}$) are known, (3) the spectral shapes of the specific absorption coefficients for phytoplankton ($a^*_{ph}$) and suspended solid particle ($a^*_{ss}$) and the specific backscattering coefficients for phytoplankton ($b_b^*_{ph}$) and suspended solid particle ($b_b^*_{ss}$) are known. The input data of IOP inversion model is used in-situ ocean optical data at the seawater around the Korea Peninsula for 5 years (2001-2005). We compared the output data of the IOP inversion model and the in-situ observation for seawater around the Korea Peninsula.

  • PDF

Surgical Management of Coexisting Glaucoma and Cataract (녹내장과 백내장이 동반된 환자의 수술적 치료)

  • Cha, Soon-Cheol
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.1
    • /
    • pp.12-22
    • /
    • 2004
  • The management of coincident glaucoma and cataract is not only a common clinical challenge but also an important research topic in the ophthalmic surgical field. The purpose of this article is to compare the different surgical options on the basis of their achievable postoperative intraocular pressure (IOP) control, success rates, and complication rates reported in the related literature, and to give advice on how to manage typical situations of patients with both glaucoma and cataract. Main topics were focused on indications and rationale of 3 surgical options (only cataract surgery first and later trabeculectomy, only trabeculectomy first and later cataract surgery, or simultaneous combined surgery). Modern clear corneal cataract extraction techniques resulted in a modest intermediate-term reduction of IOP and has considerably improved the success rates of combined glaucoma and cataract surgery. It also enabled future trabeculectomy to be successfully performed at a later date if necessary. Trabeculectomy alone achieved better IOP regulation than phacotrabeculectomy (combined surgery), but subsequent cataract surgery may compromise preexisting filtering bleb. Combined surgery augmented with mitomycin C achieved a lower IOP than combined surgery alone but had a higher complication rate. In conclusion, the choice of the preferred surgical method should be determined according to the target pressure, the amount of glaucomatous damage, and the grade of visual disturbance caused by the cataract. Phacotrabeculectomy with adjunctive mitomycin C offers visual improvement and achieves the best IOP lowering of all types of combined glaucoma and cataract surgery currently used but is associated with potentially sight-threatening complications.

  • PDF

Evaluation on Clinical Application of Osmotic Pump with Dorzolamide in Normal Dogs

  • Kwon, Yonghwan;Kim, Jury;Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.36 no.6
    • /
    • pp.325-329
    • /
    • 2019
  • This study was designed to compare the effects of continuous release of an anti-glaucoma drug applied by an osmotic pump and by conventional eye drop instillation in normal beagle dogs, by measuring drug concentration in the blood and monitoring intra-ocular pressure (IOP). In group 1, an osmotic pump filled with Trusopt® was implanted subcutaneously over the right eye of each dog and the IOP was measured. In group 2, the right eye of each dog was administered with 2% dorzolamide (Trusopt®, Merck, USA) three times per day. Blood was sampled once per week in all groups. The IOP of the end of this study was 16.7 ± 0.58 mmHg in group 2 and 17.7 ± 2.52 mmHg in group 2. Dorzolamide concentration in blood increased continuously over 4 weeks up to 585.8 ± 79.42 ㎍/L in group 1, and 747.3 ± 27.89 ㎍/L in group 2. We achieved satisfactory results in the osmotic pump group, which had a similar effect on IOP, and low fluctuations in IOP. Therefore, the results of this study should allow osmotic pumps to be consider as an alternative method to eye drops for the effective, safe, and convenient treatment of glaucoma.

Use of a Combined Photocatalysis/Microfiltration System for Natural Organic Matter Removal (광촉매 반응과 침지형 정밀여과를 이용한 자연산 유기물의 제거)

  • 추광호;박경원;김문현
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.149-156
    • /
    • 2004
  • This work focused on the degradation of natural organic matter (NOM) present in lake water using a combined pkotocatalysisimicrofiltration (MF) process. The system performances were investigated in terms of organic removal efficiency and membrane permeability. The addition of iron oxide particles (IOP) into the photocatalytic membrane reactor improved initial NOM removal by sorption, but during photocatalysis the removal efficiency was reversed, probably due to the scattering of UV light by IOP. The modification of TiO$_2$ surfaces by IOP deposition was conducted to enhance the photocatalytic NOM removal efficiency. A minimal amount of Impregnation of IOP on TiO$_2$ surfaces was required to prevent the light scattering effect as well. The coating of MF membranes with IOP helped to improve the NOM removal efficiency while sorbing NOM by IOP. Regardless of tile operating conditions and particles addition examined, no significant fouling was occurring at a flux of 15 L/$m^2$-h during entire MF operation.

Body Mass Index Compared with Waist Circumference Indicators as a Predictor of Elevated Intraocular Pressure (안압상승의 위험인자로서 체질량지수(BMI)와 허리둘레의 비교)

  • Park, Sang-Shin;Lee, Eun-Hee;Paek, Domyung;Cho, Sung-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.293-297
    • /
    • 2010
  • Purpose: The aim of the current study was to compare body mass index (BMI) with waist circumference (WC) as a predictor of elevated intraocular pressure (IOP). Methods: The subjects were consisted of 458 adults, aged 20 year or above, of one community in Kyunggi-do. Mean IOPs were stratified jointly for BMI and WC tertiles. Multi-variate linear regression analysis was also used to compare between BMI and WC. Results: Although any BMI tertiles were not associated with IOP within each tertile of WC, WC tertiles was significantly related to elevation of IOP within the third BMI tertile (${\geq}24.9kg/m^2$). After adjusting for age and sex, only WC showed significant association with IOP. In additional adjustment for lifestyle variables, both BMI and WC were significantly associated with elevation of IOP. However, the results showed the stronger association of IOP with WC than BMI, whether they were adjusted by age and sex or additionally lifestyle variables. Conclusions: These data showed that BMI and WC were positively associated with IOP. However, WC appeared to be a better indicator for higher IOP than BMI.

Scalp Acupuncture and Master Tung Distal Points for the Treatment of Intraocular Pressure for a Patient with Borderline Glaucoma

  • Chapleau, Christopher
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.2
    • /
    • pp.13-16
    • /
    • 2018
  • Acupuncture has been clinically used to treat patients suffering from eye disease. It has been used in efforts to help preserve vision for those with a wide range of eye conditions including glaucoma and intraocular hypertension. High intraocular pressure (IOP) is usually associated with glaucoma and conventional treatment is focused on lowering IOP. Controlling this risk factor should help hasten the onset of glaucoma for those patents that are suspect or borderline candidates for glaucoma. In review of the limited scientific research there are not many studies that support conclusive evidence for the use of acupuncture on eye diseases and particularly glaucoma and ocular hypertension. For the information that does exist, diverse results from various interventions make it difficult to draw clear conclusions. The existing studies use different acupoints, techniques, frequencies, and durations. Individual treatment strategies according to the practitioner's subjective experience, patient condition, and the use of other complimentary and natural strategies is ideal for taking a more dynamic and wholistic approach to getting results. Until more pragmatic research models are funded and implemented, case reports can offer good examples of experiential and objective outcomes. This case report presents a 61 year old healthy female patient diagnosed with open-angle borderline glaucoma with elevated IOP. The patients IOP was successfully reduced with 12 treatments over three months using scalp electro-acupuncture and distal Master Tung points.

Development of Integrated Operating Program for Inshore Test Miner and its Simulator (근해역 시험집광기용 통합운용 프로그램 및 시뮬레이터 개발)

  • Lee, Do-Kyoung;Yoon, Suk-Min;Park, Soung-Jea;Yeu, Tae-Kyeong;Hong, Sup;Kim, Hak-Kyeong;Kim, Sang-Bong
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.78-84
    • /
    • 2009
  • This paper presents development results of integrated operating program and its simulator for an inshore test miner. The inshore test miner drives on the seabed and collects manganese nodules. For operating the test miner, integrated operating program (IOP) is needed for remote control and monitor of the miner in real-time. However, it is hard to develop the practical IOP for the test miner system, because the system is big, expensive, and unique. So a simulator was developed as a test substitute in order to save time and to reduce cost. Using test results of the simulator, the IOP of the test miner was developed. The developed IOP consists of remote program, host program, monitoring program and database program. The operating program was developed using PXI and Labview of NI. The experimental results are presented to show the applicability of the developed program.

Development of Inductive and Capacitive Type Intraocular Pressure (IOP) Sensor to Improve Sensitivity and Minimize Size (민감도 향상과 센서 소형화를 위한 자기 및 용량형 안압센서의 개발)

  • Jang, Cheol In;Shin, Kyeong-Sik;Yun, Kwang-Seok;Kim, Yong Woo;Kang, Ji Yoon;Lee, Soo Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.409-415
    • /
    • 2014
  • We had presented an inductive type intraocular pressure sensor (L-sensor) in previous work. The distance between a micro coil and a ferrite on the membrane was modulated by pressure, and as a result the inductance and resonant frequency were changed. However, L-sensor has some problems to implant in eyes. First problem is low sensitivity. When L-sensor was implanted in rabbit's eyes, resonant frequency of L-sensor was very hard to detect. Second problem is biocompatibility. Size of L-sensor is $6{\times}7{\times}1.2mm$. When L-sensor was implanted in the eyes, it caused the inflammation. Therefore, this study suggests an inductive and capacitive type IOP sensor (LCsensor). The sensitivity of the LC-sensor 27.3 kHz/mmHg under 60mmHg. It is much larger than 14 kHz/mmHg of the L-sensor. And the size of LC-sensor is 47% smaller than L-sensor. After 2 weeks from the implantation of LC-sensor into rabbit eyes, we measured the changes of resonant frequency of LC-sensor according to increased IOP by Balanced Salt Solution (BSS) injection. As a result, the sensitivity of LC-sensor in in vivo test is 25 kHz/mmHg. That is similar to the sensitivity of in vitro test.

Retrospective study of postoperative intraocular pressure and complications in phacoemulsification combined with endoscopic cyclophotocoagulation and phacoemulsification alone in dogs

  • Sol Kim;Seonmi Kang;Youngseok Jeong;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.16.1-16.11
    • /
    • 2023
  • Background: Long-term comparative data of phacoemulsification combined with endoscopic cyclophotocoagulation (phaco-ECP) versus phacoemulsification (phaco) alone in dogs are rare. Objectives: To investigate the effects of ECP on postoperative intraocular pressure (IOP) and complications after phaco in dogs with normal IOP. Methods: Medical records of IOP, conjunctival hyperemia, corneal edema, aqueous flare, posterior synechia, intraocular fibrin, and posterior capsule opacification (PCO) formation in 15 canine eyes that underwent phaco-ECP and 36 eyes that underwent phaco alone were evaluated retrospectively. ECP was applied when either the iridocorneal angle or the ciliary cleft was narrow or closed. Results: The IOP of the phaco-ECP group persisted within the normal range postoperatively. The phaco-ECP group had a shorter period of dorzolamide use than did the phaco group. PCO was formed earlier in the phaco-ECP group than in the phaco group. The phaco-ECP group showed more severe corneal edema than the phaco group at every follow-up visit. Posterior synechia was more severe in the phaco-ECP group than in the phaco group from two weeks until the last follow-up. Conclusions: Although ECP might cause more postoperative complications such as corneal edema and posterior synechia, it could effectively reduce the incidence of IOP increase after phaco in dogs with a high risk of postoperative glaucoma.