• 제목/요약/키워드: IOC

검색결과 64건 처리시간 0.023초

보중치습탕(補中治濕湯)의 도핑검사 대상약물(對象藥物)에 관(關)한 연구(硏究) (A Study on Doping Test of Bojungchisheup-tang)

  • 김성용;금동호;이명종
    • 한국한의학연구원논문집
    • /
    • 제3권1호
    • /
    • pp.289-319
    • /
    • 1997
  • Non-medical use of drugs to enhance performance at Olympic Games by athletes has been prohibited by the International Olympic Committee(IOC) since 1968 on medical and ethical grounds. IOC wants to protect athlete from harmful side effect of drugs due to misuse of it. It also, ethically, wants to have Games run on fair base, not fortified by performance enhancing drugs, The banned substances include stimulants, narcotic analgesics, anabolic sterolds, ${\beta}-blockers$ and diuretics. In order to prevent the positive reaction in the doping test induced by herb medicine, this study was done on about Bojungchisheup-tang. The laboratory set up doping analyses methods to cover as many drugs as possible without sacrificing sensitivity and specificity within one procedure. Its screening method consisted of four different procedures. The results were negative. According to the above results, Bojungchisheup-tang taken by athletes would show the negative reaction in the doping test. So its prescription for athletes can be given without worries of the doping test.

  • PDF

포항가속기의 Reflective Memory를 이용한 독립형 BPM 제어시스템 개발 (Development of Independent BPM Control System Using Reflective Memory at PLS)

  • 윤종철;이진원;이은희;강흥식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1697-1698
    • /
    • 2008
  • PLS(Pohang Light Source) is 2.5 Gev synchrotron radiation source in Pohang, Korea, which is under operation since 1995. The hardware and software of the old BPM(Beam Position Monitor) data acquisition system for the PLS storage ring was completely upgraded to increase its performance and stability. The new BPM data acquisition system is based on VME-based EPICS (Experimental Physics and Instrument Control System) IOC system. We used 16-bit resolution analog-to-digital conversion board to digitize analog BPM signals. We developed a data average software to average raw BPM data using reflective memory board. We also developed device drivers for VME I/O boards used, IOC database for PV's(Process Variables). The new BPM data acquisition system is currently running for routine operation with good performance and stability. In this paper, we present the hardware and software of the new BPM data acquisition system DTL water skid cooling system and Resonant Control Cooling.

  • PDF

GC/MS를 이용한 소변중의 Cyclofenil 및 그 대사체의 분석 (Analysis of Cyclofenil and its Metabolites in Human Urine using GC/MS)

  • 명승운;민혜기;조현우;김동현;김명수
    • 분석과학
    • /
    • 제15권3호
    • /
    • pp.185-189
    • /
    • 2002
  • Cyclofenil은 국제올림픽위원회(IOC)에서 금지약물로 규정하고 있다. 이에 따라 본 실험에서는 GC/MS를 사용하여 소변으로부터 cyclofenil의 복용여부를 검사할 수 있는 방법을 만들었다. 이를 위하여 cyclofenil 및 그 대사체들의 추출 회수율을 측정하였는데 pH 5-9 사이가 최적의 추출 조건이었으며, 소변으로는 모 약물인 cyclofenil은 배설되지 않아서 검출하지 못하였고 대신에 그 대사체들을 검출함으로써 cyclofenil의 복용여부를 검출할 수 있었다. 따라서 대사체들은 가수분해 후 pH 9.6에서 에테르로 추출하여 MSTFA로 유도체화시켜서 GC/MS로 분석하였다.

세계 해양관측 시스템 구축 계획과 국지 연안 모니터링 시스템

  • 이동영
    • 한국해안해양공학회:학술대회논문집
    • /
    • 한국해안해양공학회 1993년도 정기학술강연회 발표논문 초록집
    • /
    • pp.186-188
    • /
    • 1993
  • 90년대에 와서 지구규모의 환경변동을 과학적으로 규명하고 예측하기 위한 해양의 계속적인 관측과 연구에 국제적인 관심을 보이고 있다 지구 환경 변화 연구와 관련하여 1992년 여름 세계해양 관측시스템(GOOS) 계획이 제안되어 이를 여러 전문가의 검토를 거처 보완하여 1993년 봄 UNESCO의 정부간 해양 위원회(IOC) 총회에서 채택 되었고 작년에 환경과 개발에 관한 국제 회의(UNCED)에서도 “21세기를 향한 행동 계획”으로 채택되었다. (중략)

  • PDF

GC/MS를 이용한 carteolol의 대사 및 배설연구 (Study on Metabolism and Excretion of Carteolol in Human Urine using GC/MS)

  • 민혜기;김명수;조현우;김택제;김동현;명승운
    • 분석과학
    • /
    • 제15권5호
    • /
    • pp.482-487
    • /
    • 2002
  • Carteolol은 국제올림픽위원회 (IOC)에서 금지약물로 규정하고 있는 ${\beta}$-차단제 중의 하나이다. 본 실험에서는 GC/MS를 사용하여 사람의 소변으로부터 carteolol의 복용여부를 확인하기 위한 검출방법 및 대사와 배설에 대해서 고찰하였다. 이를 위하여 효소 가수분해방법과 산 가수분해방법을 비교하여 보았는데 효소가수분해방법이 더 좋은 결과를 얻을 수 있었다. 효소 가수분해방법을 이용하여 실험한 결과 RSD 10%내외의 정밀도와 $0.05{\mu}g/m{\ell}$를 제외하고는 오차 5%이내의 좋은 정확도를 보여주었으며 회수율은 78.5%로 나타났다. Carteolol은 소변에서 대부분이 free carteolol과 conjugated carteolol로 존재하며 소량의 p-OH-carteolol로 대사됨을 알 수 있었으며 모 약물로 배출되는 양 중 conjugated form이 59.4%로 나타났다. 소변으로 배출된 carteolol의 양을 측정한 결과 복용양의 49%가 복용 후 72시간까지 모 약물로 배출됨을 알 수 있었다.

GLOBEC 프로그램의 목적, 운영체계 및 최근의 동향에 대하여 (Goal, Structure, and Recent Development of the GLOBEC Programme)

  • 김수암
    • 한국해양학회지:바다
    • /
    • 제5권1호
    • /
    • pp.10-15
    • /
    • 2000
  • 기후변동에 따른 해양생태계의 변화를 예측하기 위한 국제 연구 프로그램인 Global Ocean Ecosystem Dynamics (GLOBEC)은 해양의 탄소순환을 집중적으로 연구한 Joint Global Ocean Flux Study(JGOFS)의 후속조치로서, 이 논문에서는 GLOBEC 프로그램의 목적, 방향, 실천계획, 체제를 정리하였다. 해양과학위원회(SCOR)와 정부간해양위원회(IOC)의 후원을 동시에 받고 있는 대형과학프로그램인 GLOBEC은 기후변화에 따른 생태계의 중위 및 상위포식자의 반응에 대한 연구이며, GLOBEC 과학집행위원회는 연구를 수행하기 위한 실천계획을 1999년에 수립하였다. GLOBEC 프로그램은 국제생지권프로그램(IGBP)의 핵심과제로 지정되어 향후 10년 동안 지속될 것이며, 구체적으로 4개의 연구 초점, 체제구축활동, 지역프로그램, 종합화 등으로 구성되어 있다. 가장 중요한 연구활동인 4개의 연구초점은 다음과 같다: 과거자료분석(Retrospective analyses), 과정 연구(Process studies), 예측과 모델링(Predictive and modelling capability), 되먹임(Feedbacks). 현재, 남극해 GLOBEC(SO-GLOBEC), 소형표층어류와 기후변화(SPACC), 대구와 기후변화(CCC), 기후변화와 환경수용력(CCCC)의 4개 국제적 지역프로그램이 있으며, 이들은 모두 우리나라 해양 및 수산연구와 밀접한 관련이 있다. 미국, 일본 등의 9개국은 국가프로그램을 운영하고 있으며, 이 수효는 점차 증가할 전망이다.

  • PDF

운동선수들의 뇨 중 Human Chorionic Gonadotropin 분석 및 분석킷트 평가 (Assay of Human Chorionic Gonadotropin in Urine of Athletes and Evaluation of Assay Kit Performance)

  • 최명자;이정란;김명수
    • Biomolecules & Therapeutics
    • /
    • 제10권3호
    • /
    • pp.186-192
    • /
    • 2002
  • Special attention has been paid to human chorionic gonadotropin (hCG) for athlete doping control because it stimulates the endogenous production of testosterone and epitestosterone without increasing the T/E ratio which is a doping indicator for the exogenous administration of testosterone. Even though the IOC banned the use of hCG, a detection method has not been decided upon since there are a variety of immunoassay kits available on the market. We evaluated three kits in terms of their performance characteristics. The assay value of the control sample varied depending on the kit, resulting in 198 mIU/ml for the MAIA kit, 172mIU/ml for the IRMA kit, and 143 mIU/ml for the MEIA kit. Considering the IOC inter-lab distribution of results(55-312 mIU/ml) using 27 different kits and the mean value (178$\pm$56 mIU/ml), all three kits are within the range of -15.8% - +5.6% of the mean value, which proves them useful for the hCG assay. The MEIA kit resulted in lower hCG values because it detects only intact hCG molecules, in contrast to the other two kits which detect intact hCG and -hCG together. However, it is suitable for screening purposes because of its advantage of being an automated system. When 123 urine samples of athletes were analyzed in 22 batches using this system, the variation of control values fell within $\pm$ 10% of the mean values, and an specimens tested negative with hCG values less than the detection limit of 2 mIU/ml.

소방공무원의 대처, 자기노출, 반추, 조직문화가 외상 후 성장에 미치는 영향 (Influence of Coping, Self-Disclosure, Ruminant, and Organizational Culture on Traumatic Growth of Firefighters)

  • 고영심;하영미;김지아;조한아
    • 디지털융복합연구
    • /
    • 제18권4호
    • /
    • pp.357-369
    • /
    • 2020
  • 본 연구는 소방공무원의 대처, 자기노출, 반추, 조직문화와 외상 후 성장(Posttraumatic Growth, PTG)의 정도를 살펴보고, PTG의 영향요인 규명을 위해 시행되었다. 자료수집은 경상도 소재 3개 소방서에 근무하는 소방공무원 103명을 대상으로 실시하였다. 연구결과 중~고 수준 PTG가 46명(44.7%)로 평균 58.07점이었으며 전체 PTG 평균은 44.56점으로 나타났다. PTG에 영향을 미치는 요인은 정서중심대처, 자기노출, 의도적 반추와 혁신지향 조직문화로 나타났으며 네 변수의 PTG에 대한 설명력은 45.9%로 나타났다. 소방공무원의 PTG촉진을 위해 정서중심대처, 자기노출, 의도적 반추 뿐 아니라 혁신지향 문화구축이라는 조직측면의 접근이 필요하며 이러한 결과는 소방공무원의 PTG 향상을 위한 중재방안에 활용될 수 있다.

요르단연구로건설사업 문서관리시스템 구축 (Establishment of Document Control System for the Jordan Research and Training Reactor Project)

  • 박국남;고영철;우상익;오수열;이두정
    • 산업경영시스템학회지
    • /
    • 제34권4호
    • /
    • pp.49-56
    • /
    • 2011
  • The Project of Jordan Research and Training Reactor (JRTR) officially launched in Aug. 2010. JRTR is the first made-in-Korea nuclear system to be built abroad by year 2015, and Korea Atomic Energy Research Institute (KAERI) is responsible for the design of major systems including the reactor core. While the PDCS (Project Document Control System) being operated by EPC company controls all the documents of the whole Project, KAERI is supposed to have its own system for KAERI documents. Meeting such a need; KAERI has implemented a document control for the JRTR Project into already existing ANSIM (KAERI Advanced Nuclear Safety Information Management) system. The documents of JRTR project to be controlled are defined in the PPM (Project Procedures Manual), QAP (Quality Assurance Procedure) and PEP (Project Execution Program). The ANSIM consists of the document management holder, document container holder and organization management holder. The document management holder, which is the most important part of ANSIM-JRTR, consists of the DDA (Document Distribution for Agreement), IOC (Inter-office Correspondence), PM Memo. (Project Manager Memorandum) and cover sheets of design documents. Other materials such as meeting minutes, sub-department materials and design information materials are stored in an independent COP (Community of Practice). This established computerized document control system, ANSIM, could lessen a burden for project management team and enhance the productivity as well.

복합화력발전기의 신뢰도 기반 유지보수를 위한 확률론적 FMECA 평가 (Stochastic FMECA Assessment for Optimal RCM of Combustion-Turbine Generating Unit)

  • 주재명;이승혁;신준석;김진오
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.254-259
    • /
    • 2007
  • PM(Preventive Maintenance) can avail the generating unit to reduce cost and gain more profit in a competitive supply-side power market. So, it is necessary to perform reliability analysis on the power systems in which reliability is essential. Thus, to schedule optimal PM planning based on reliability that is defined RCM(Reliability-Centered Maintenance), FMECA(Failure Mode Effects and Criticality Analysis) assessment is very important. Therefore, in this paper, the procedure of FMECA assessment for optimal RCM is proposed by probabilistic approach using real historical failure data of combustion-turbine generators in Korean power systems. The stochastic FMECA is performed based on the effects of probable failure modes of combustion-turbine generating unit.