Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value

  • Yoon, Hong-Gi;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Su-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.10-15
    • /
    • 2011
  • PURPOSE. This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS. Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS. In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION. Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone.

무치악에 대한 최소 임플란트의 구조물의 3차원 유한요소 해석 (The 3-Dimensional Finite Element Analysis of Minimum Implant Structure for Edentulous Jaw)

  • 장인식
    • 한국정밀공학회지
    • /
    • 제25권2호
    • /
    • pp.148-155
    • /
    • 2008
  • The aim of the study is to interpret the distribution of occlusal force by 3-dimensional finite element analysis of ISP(Implant Supported Prosthesis) supported by minimum number of implant to restore the edentulous patients. For this study, the Astra Tech implant system is used. Geometric modeling for 6 and 4 fixture ISP group is performed with respect to the bone, implant and one piece superstructure, respectively. Implants are arbitrarily placed according to the anatomical limit of lower jaw and for the favorable distribution of occlusal force, which is applied at the end of cantilever extension of ISP with 30mm. Element type is tetrahedral for finite element model and the typical mechanical properties, Young's modulus and Poisson's ratio of each material, cortical, cancellous bone and implant material are utilized for the finite element analysis. From this study, we can see the distribution of equivalent stress equal to real situation and speculate the difference in the stress distribution in the whole model and at each implant fixture, From the analysis, the area of maximum stress is distributed on distal contact area between bone and fixture in the crestal bone. The maximum stress is 53MPa at the 0.2mm area from the bone-implant interface in the maximum side for 300N load condition for 4 fixture case, which is slightly less than the stress calculated from allowable strain. This stress has not been deduced to directly cause the loss of crestal bone around implant fixture, but the stress can be much reduced as the old peoples may have lower chewing force. Thus, clinical trial may be performed with this treatment protocol to use 4 fixtured ISP for old patients.

Biomechanical stability of internal bone-level implant: Dependency on hex or non-hex structure

  • Lee, Hyeonjong;Park, Si-Myung;Noh, Kwantae;Ahn, Su-Jin;Shin, Sangkyun;Noh, Gunwoo
    • Structural Engineering and Mechanics
    • /
    • 제74권4호
    • /
    • pp.567-576
    • /
    • 2020
  • Considerable controversy surrounds the choice of the best abutment type for implant prosthetics. The two most common structures are hex and non-hex abutments. The non-hex abutment typically furnishes a larger contact area between itself and the implant than that provided by a hex structure. However, when a hex abutment is loaded, the position of its contact area may be deeper than that of a non-hex abutment. Hence, the purpose of this study is to determine the different biomechanical behaviors of an internal bone-level implant based on the abutment type-hex or non-hex-and clinical crown length under static and cyclic loadings using finite element analysis (FEA). The hex structure was found to increase the implant and abutment stability more than the nonhex structure among several criteria. The use of the hex structure resulted in a smaller volume of bone tissues being at risk of hypertrophy and fatigue failure. It also reduced micromovement (separation) between the implant components, which is significantly related to the pumping effect and possible inflammation. Both static and fatigue analyses, used to examine short- and long-term stability, demonstrated the advantages of the hex abutment over the non-hex type for the stability of the implant components. Moreover, although its impact was not as significant as that of the abutment type, a large crown-implant ratio (CIR) increased bone strain and stress in the implant components, particularly under oblique loading.

임프란트 주위염에 대한 Er,Cr:YSGG 레이저 조사가 미치는 영향 (EFFECTS ON ER,CR:YSGG LASER ON PERI-IMPLANTITIS)

  • 최성림;김진환;황동현;민승기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권5호
    • /
    • pp.428-436
    • /
    • 2008
  • For Longevity of implant, considerations of biomechanical and microbiological aspects must be done. Recently, due to the remarkable development of bone grafting procedure. Implant has been implanted into the more favorable sites but peri-implantitis resulted from periodontal bacteria may obscure the long-term prognosis. Although many different modalities have been introduced to treat the failed implant. Implant's surface and irreversible bony destruction around the implant prevents good result. After Er,Cr:YSGG (waterlase) laser using the wave-length of 2780nm has been introduced to dental field, good results have been reported. Because waterlase uses the hydrokinetic force of water. It is excellent device to detoxify the implant surface mechanically without the heat generation and damage to the implant surface. We designed to evaluate waterlase effect on the peri-implantitis has been occurred after implantation. Four beagle dogs were involved. We have made four premolar extraction in each right and left side of the lower jaw and placed two implants in the anterior of the jaw as a control and six implant were placed posterior in each socket after extraction immediately as an experimental group. We tied floss-silk in each implant to make peri-implantitis intentionally. After three months, we explored peri-implant sites on each experimental fixtures. Using waterlase laser irradiation was performed on that implantitis sites under 3W, air 30% and water 20% intensity for 2 minutes. In control group, we repositioned the flap to cover the exposed fixture without any supportive care. Three months later, we sacrificed experimental animals and extracted and preparated bone blocks with Donath and Breuner (982), Donath (988)'s methods and examined under microscope. We have obtained good re-osseointegration around fixtures after treating with waterlaser irradiation. But it was shown fibroosseointegration in the control group.

Comparative study on the osseointegration of implants in dog mandibles according to the implant surface treatment

  • Yoon, Wook-Jae;Kim, Su-Gwan;Oh, Ji-Su;You, Jae-Seek;Jeong, Kyung-In;Lim, Sung-Chul;Jeong, Mi-Ae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권6호
    • /
    • pp.345-351
    • /
    • 2016
  • Objectives: This study compared the impact of implant surface treatment on the stability and osseointegration of implants in dog mandibles. Materials and Methods: Six adult dogs received a total of 48 implants that were prepared using four different surface treatments; resorbable blast media (RBM), hydroxyapatite (HA), hydrothermal-treated HA, and sand blasting and acid etching (SLA). Implants were installed, and dogs were separated into 2- and 4-week groups. Implant stability was evaluated via Periotest M, Osstell Mentor, and removal torque analyzers. A histomorphometric analysis was also performed. Results: The stability evaluation showed that all groups generally had satisfactory values. The histomorphometric evaluation via a light microscope revealed that the HA surface implant group had the highest ratio of new bone formation on the entire fixture. The hydrothermal-treated HA surface implant group showed a high ratio of bone-to-implant contact in the upper half of the implant area. Conclusion: The hydrothermal-treated HA implant improved the bone-to-implant contact ratio on the upper fixture, which increased the implant stability.

치근형 골내 임플란트의 초기 1년간 치조골 소실 및 골 밀도 변화에 관한 연구 (ALVEOLAR BONE LOSS & BONE DENSITY CHANCES DURING THE FIRST YEAR A COMPARATIVE STUDY ON FOUR TYPES OF ROOT-FORM ENDOSSEOUS DENTAL IMPLANT SYSTEMS)

  • 정영철;한종현;이근우
    • 대한치과보철학회지
    • /
    • 제32권3호
    • /
    • pp.455-469
    • /
    • 1994
  • Regular radiographic examination has been considered an essential diagnositic method for osseointegrated dental implantation. This study investigated marginal bone loss through the measurement on periapical radiographs and changes in bone density through digital subtraction image radiographic method around 88 endoseous root-form dental implants in 43 human subjects. Four types of endosseous dental implants were investigated : Standard series, Mini series and Hex-lock system of Steri-Oss Dental implant system, and $Br{\aa}nemark$-type implant from 3i dental implant system, in a 3 month interval for a total period of 12 months. The results were as follows : 1. Rapid bone loss occurred in the first 3 months in all 4 groups, and the bone level stabilized at the first thread of the implant fixtures. Amount of bone loss for 12 months showed correlation with the length of the polished neck portion. 2. Most of the implant systems showed resorption of alveolar bone up to the polished neck portion although a long polished neck could delay the resolution. 3. Alveolar bone loss apical to the polished neck portion stabilized at the first thread of the fixtures with no correlation to either the time of exposure of the polished neck or types of implant systems. 4. No changes in bone density around the implant threads were observed throughout the experimental period. Bone density decreased at the marginal bone, and increased at the newly-formed alveolar crest. These results indicate that most of the alveolar bone loss occur within the first 12 months after installation of endosseous root-form dental implants resulting in the exposure of polished neck portions, and the bone level stabilizes thereafter at the first thread portions of the implant fixtures. The experimental period of 12 months seems insufficient for observing changes in bone density, and a long-term observation should be needed.

  • PDF

3차원 기하 처리와 유한요소 분석을 이용한 치아 임플란트 식립 계획 수립 (Planning of Dental Implant Placement Using 3D Geometric Processing and Finite Element Analysis)

  • 박형욱;박철우;김명수;박형준
    • 한국CDE학회논문집
    • /
    • 제17권4호
    • /
    • pp.253-261
    • /
    • 2012
  • In order to make dental implant surgery successful, it is important to perform proper planning for dental implant placement. In this paper, we propose a decent approach to dental implant placement planning based on geometric processing of 3D models of jawbones, a nerve curve and neighboring teeth around a missing tooth. Basically, the minimum enclosing cylinders of the neighboring teeth around the missing tooth are properly used to determine the position and direction of the implant placement. The position is computed according to the radii of the cylinders and the center points of their top faces. The direction is computed by the weighted average of the axes of the cylinders. For a cylinder whose axis passes the position along the direction, its largest radius and longest length are estimated such that it does not interfere with the neighboring teeth and the nerve curve, and they are used to select the size and type of an implant fixture. From the geometric and spatial information of the jawbones, the teeth and the fixture, we can construct the 3D model of a surgical guide stent which is crucial to perform the drilling operation with ease and accuracy. We have shown the validity of the proposed approach by performing the finite element analysis of the influence of implant placement on bone stress distribution. Adopted in 3D simulation of dental implant placement, the approach can be used to provide dental students with good educational contents. It is also expected that, with further work, the approach can be used as a useful tool to plan for dental implant surgery.

The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • 제46권3호
    • /
    • pp.152-165
    • /
    • 2016
  • Purpose: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. Methods: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. Results: The maximum extent of micromotion was approximately $100{\mu}m$ in the low-density cancellous bone models, whereas it was under $30{\mu}m$ in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. Conclusions: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading.

Influence of the connection design and titanium grades of the implant complex on resistance under static loading

  • Park, Su-Jung;Lee, Suk-Won;Leesungbok, Richard;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.388-395
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the resistance to deformation under static overloading by measuring yield and fracture strength, and to analyze the failure characteristics of implant assemblies made of different titanium grades and connections. MATERIALS AND METHODS. Six groups of implant assemblies were fabricated according to ISO 14801 (n=10). These consisted of the combinations of 3 platform connections (external, internal, and morse tapered) and 2 materials (titanium grade 2 and titanium grade 4). Yield strength and fracture strength were evaluated with a computer-controlled Universal Testing Machine, and failed implant assemblies were classified and analyzed by optical microscopy. The data were analyzed using the One-way analysis of variance (ANOVA) and Student's t-test with the level of significance at P=.05. RESULTS. The group $IT4_S$ had the significantly highest values and group IT2 the lowest, for both yield strength and fracture strength. Groups $IT4_N$ and ET4 had similar yield and fracture strengths despite having different connection designs. Group MT2 and group IT2 had significant differences in yield and fracture strength although they were made by the same material as titanium grade 2. The implant system of the similar fixture-abutment interfaces and the same materials showed the similar characteristics of deformation. CONCLUSION. A longer internal connection and titanium grade 4 of the implant system is advantageous for static overloading condition. However, it is not only the connection design that affects the stability. The strength of the titanium grade as material is also important since it affects the implant stability. When using the implant system made of titanium grade 2, a larger diameter fixture should be selected in order to provide enough strength to withstand overloading.

Conical connection 임프란트(Ankylos dental implant)에 대한 후향적 임상연구 (Retrospective study of conical connection dental implant (Ankylos dental Implant).)

  • 양병은;송상훈;심혜원;이상민;김성곤
    • 대한치과의사협회지
    • /
    • 제44권11호통권450호
    • /
    • pp.739-747
    • /
    • 2006
  • Objectives. The standardization of connection between fixture and abutment has not been defined. The success of dental implants was not always depends on connection. However, the connection mechanism is one of the most important things for dental implant treatment success. Most implant systems are very comparable in their design and engineering. They share many common characteristics and have similar strengths and weaknesses. Their significant weaknesses are connection, microgap and the resulting micromovement allowing bacterial contamination and bone loss. In the present study, we investigated the clinical performance of Ankylos implant (conical connection implant) Patients and Methods. The clinical performance of conical connection implant was studied under well-controlled clinical conditions. A total of 133 conical connection implants were placed in 50 patients from April 2005 to March 2006. The mean follow-up loading period of implants which was considered successful was 220$\pm$29 days. We recorded the age, sex, installation site, reason of edentulous region, bone density of installation site, diameter and length of dental implants and periods from installation to uncovering surgery using patients medical chart. Results Four Ankylos implants were lost during pre-loading period. 129 implants provided excellent clinical performance during 220$\pm$29 days on an average. The short-term success rate of this conical connection implant system was 96.99%.

  • PDF