• Title/Summary/Keyword: III-V materials

Search Result 255, Processing Time 0.03 seconds

Comparison of Prevention Methods against Enamel Demineralization adjacent to Orthodontic Bracket Using Fluoride (교정용 브라켓 주위의 불소를 이용한 법랑질 탈회 예방 방법 비교)

  • Mo, Hyelim;Kim, Jongsoo;Oh, Sohee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.3
    • /
    • pp.293-300
    • /
    • 2019
  • As a common side effect of fixed orthodontic treatment, demineralization of the enamel adjacent to the bracket and band occurs in patients with poor oral hygiene. The purpose of this study was to investigate what is the most effective method to prevent demineralization around the fixed orthodontic appliance among various methods using fluoride. 80 extracted bovine incisors with a healthy surface were classified into four groups as experimental materials: (Group I) Control group, (Group II) V $varnish^{TM}$, (Group III) Tooth Mousse $Plus^{(R)}$, (Group IV) $Vanish^{TM}$ XT. After treatment for each group, mineral loss and Vickers surface microhardness were measured at 0, 30, 60 and 90 days after demineralization in artificial carious solution. Mineral loss was the lowest in group IV, followed by group II and group III, which showed a significant difference. The surface microhardness was the lowest in group IV, followed by group II and group III, which showed a significant difference. Through this study, group IV showed the best effect to prevent enamel demineralization around the bracket. Group III showed significant prevention of enamel demineralization compared with the control group, but the effect was less than that of the other groups.

Applications of Nanowire Transistors for Driving Nanowire LEDs

  • Hamedi-Hagh, Sotoudeh;Park, Dae-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.2
    • /
    • pp.73-77
    • /
    • 2012
  • Operation of liquid crystal displays (LCDs) can be improved by monolithic integration of the pixel transistors with light emitting diodes (LEDs) on a single substrate. Conventional LCDs make use of filters to control the backlighting which reduces the overall efficiency. These LCDs also utilize LEDs in series which impose failure and they require high voltage for operation with a power factor correction. The screen of small hand-held devices can operate from moderate brightness. Therefore, III-V nanowires that are grown along with transistors over Silicon substrates can be utilized. Control of nanowire LEDs with nanowire transistors will significantly lower the cost, increase the efficiency, improve the manufacturing yield and simplify the structure of the small displays that are used in portable devices. The steps to grow nanowires on Silicon substrates are described. The vertical n-type and p-type nanowire transistors with surrounding gate structures are characterized. While biased at 0.5 V, nanowire transistors with minimum radius or channel width have an OFF current which is less than 1pA, an ON current more than 1 ${\mu}A$, a total delay less than 10 ps and a transconductance gain of more than 10 ${\mu}A/V$. The low power and fast switching characteristics of the nanowire transistor make them an ideal choice for the realization of future displays of portable devices with long battery lifetime.

Protein Expression of Stromelysin-2 in Head and Neck Squamous Cell Carcinomas

  • Kadeh, Hamideh;Heydari, Fatemeh;Saravani, Shirin;Ghodsi, Iman Najafi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7843-7846
    • /
    • 2015
  • Background: Some matrix metalloproteinases (MMPs) are involved in invasion and metastasis of head and neck squamous cell carcinoma (HNSCC). However, there are few studies on association between stromelysin-2 (ST-2) and invasive behavior of HNSCC. The purpose of this study was to investigate Stromelysin-2 expression by immunohistochemistry. Materials and Methods: This study was conducted on 81 specimens, including 61 HNSCC and 20 non neoplastic epithelium. Sections with 5 micron thickness were prepared and stained with immunohistochemistry technique. Then expression of ST-2 was evaluated according to percentage of stained cells and intensity of staining. Data were analyzed by SPSS (V.21) using Kruskal-Wallis and Tukey tests (P<0.05). Results: The 61 HNSCC specimens were grades I 36.1%, II 34.4% and III 29.5%. The level of ST-2 expressions were moderate (++) and intensive (+++) in 21.3% and 78.7% of tumors, respectively. The ST-2 expression level was only significant between the tumors with grade I and grade III (P=0.016). Tumors presented ST-2 expression with staining intensity of mild 6.6%, moderate 26.2% and strong 67.2%. Staining intensity of ST-2 in grade I tumors was significantly lower than grade II and grade III (P<0.05), and there was no significant difference between grades II and III (P=0.99). Conclusions: According to this study, the expression of ST-2 is associated with histopathological grade and tumor differentiation in HNSCCs.

Fabrication and Characterization of High Luminance WOLED Using Single Host and Three Color Dopants (단일 호스트와 3색 도펀트를 이용한 고휘도 백색 유기발광다이오드 제작과 특성 평가)

  • Kim, Min Young;Lee, Jun Ho;Jang, Ji Geun
    • Korean Journal of Materials Research
    • /
    • v.26 no.3
    • /
    • pp.117-122
    • /
    • 2016
  • White organic light-emitting diodes with a structure of indium-tin-oxide [ITO]/N,N-diphenyl-N,N-bis-[4-(phenylm-tolvlamino)-phenyl]-biphenyl-4,4-diamine [DNTPD]/[2,3-f:2, 2-h]quinoxaline-2,3,6,7,10,11-hexacarbonitrile [HATCN]/1,1-bis(di-4-poly-aminophenyl) cyclo -hexane [TAPC]/emission layers doped with three color dopants/4,7-diphenyl-1,10-phenanthroline [Bphen]/$Cs_2CO_3$/Al were fabricated and evaluated. In the emission layer [EML], N,N-dicarbazolyl-3,5-benzene [mCP] was used as a single host and bis(2-phenyl quinolinato)-acetylacetonate iridium(III) [Ir(pq)2acac]/fac-tris(2-phenylpyridinato) iridium(III) $[Ir(ppy)_3]$/iridium(III) bis[(4,6-di-fluoropheny)-pyridinato-N,C2] picolinate [FIrpic] were used as red/green/blue dopants, respectively. The fabricated devices were divided into five types (D1, D2, D3, D4, D5) according to the structure of the emission layer. The electroluminescence spectra showed three peak emissions at the wavelengths of blue (472~473 nm), green (495~500 nm), and red (589~595 nm). Among the fabricated devices, the device of D1 doped in a mixed fashion with a single emission layer showed the highest values of luminance and quantum efficiency at the given voltage. However, the emission color of D1 was not pure white but orange, with Commission Internationale de L'Eclairage [CIE] coordinates of (x = 0.41~0.45, y = 0.41) depending on the applied voltages. On the other hand, device D5, with a double emission layer of $mCP:[Ir(pq)_2acac(3%)+Ir(ppy)_3(0.5%)]$/mCP:[FIrpic(10%)], showed a nearly pure white color with CIE coordinates of (x = 0.34~0.35, y = 0.35~0.37) under applied voltage in the range of 6~10 V. The luminance and quantum efficiency of D5 were $17,160cd/m^2$ and 3.8% at 10 V, respectively.

Multi-step growth of a-plane GaN epitaxial layer on r-plane sapphire substrate by HVPE method (HVPE를 이용하여 r-plane 사파이어 위에 multi-step으로 성장시킨 a-plane GaN 에피층의 특성 연구)

  • Lee, Won-Jun;Park, Mi-Seon;Jang, Yeon-Suk;Lee, Won-Jae;Ha, Ju-Hyung;Choi, Young-Jun;Lee, Hae-Yong;Kim, Hong-Seung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.3
    • /
    • pp.89-94
    • /
    • 2016
  • In this study, the crystalline property of a-plane GaN epitaxial layer grown on r-plane sapphire by a HVPE method has been investigated according to the V/III ratio and the growth time of multi-step growth. Furthermore, these results were compared with the previous result obtained from the single-step growth of a-plane GaN on r-plane sapphire substrate. In the multi-step growth for a-plane GaN epitaxial layer on r-plane sapphire, the FWHM values of rocking curve in GaN epitaxial layer were decreased as the HCl source flow rate and the growth time were increased. The void formed in epitaxial layer was continuously decreased as the growth time in first step and second step using a higher HCl flow rate was increased. As a result, the GaN layer obtained with the longest growth time on the first step and second step exhibited the lowest FWHM values of 584 arcsec and the smallest dependence of azimuth angle.

Particle loading as a design parameter for composite radiation shielding

  • Baumann, N.;Diaz, K. Marquez;Simmons-Potter, K.;Potter, B.G. Jr.;Bucay, J.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3855-3863
    • /
    • 2022
  • An evaluation of the radiation shielding performance of high-Z-particle-loaded polylactic acid (PLA) composite materials was pursued. Specimens were produced via fused deposition modeling (FDM) using copper-PLA, steel-PLA, and BaSO4-PLA composite filaments containing 82.7, 75.2, and 44.6 wt% particulate phase contents, respectively, and were tested under broad-band flash x-ray conditions at the Sandia National Laboratories HERMES III facility. The experimental results for the mass attenuation coefficients of the composites were found to be in good agreement with GEANT4 simulations carried out using the same exposure conditions and an atomistic mixture as a model for the composite materials. Further simulation studies, focusing on the Cu-PLA composite system, were used to explore a shield design parameter space (in this case, defined by Cu-particle loading and shield areal density) to assess performance under both high-energy photon and electron fluxes over an incident energy range of 0.5-15 MeV. Based on these results, a method is proposed that can assist in the visualization and isolation of shield parameter coordinate sets that optimize performance under targeted radiation characteristics (type, energy). For electron flux shielding, an empirical relationship was found between areal density (AD), electron energy (E), composition and performance. In cases where ${\frac{E}{AD}}{\geq}2MeV{\bullet}cm{\bullet}g^{-1}$, a shield composed of >85 wt% Cu results in optimal performance. In contrast, a shield composed of <10 wt% Cu is anticipated to perform best against electron irradiation when ${\frac{E}{AD}}<2MeV{\bullet}cm{\bullet}g^{-1}$.

Investigation of osseointegration according to the healing time after having iatrogenic mobility of implant fixtures (임플란트 고정체의 인위적 비틀림 후 시간 경과에 따른 골재유착 반응에 관한 연구)

  • Hwang, Yun-Jin;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.308-314
    • /
    • 2010
  • Purpose: The purpose of this study is to analyze the change in re-osseointegration over time and bone reaction at the interface between implant fixture and the surface of the bone, after destroying re-osseointegration by distorting the bone-implant interface artificially. Materials and methods: Experimental implant fixtures (cp titanium, ${\phi}3.75\;mm{\times}4\;mm$) which didn't have surface treatment were produced. Two or three fixtures were implanted on both tibias of twelve female rabbits (New Zealand white, more than 3.5 kg). Then after six weeks, removal torque (RT) was measured and the results were recorded as the first measurement values. The fixtures were submerged again to get reosseointegration between the bone and fixture. To identify the change in re-osseointegration of submerged fixtures over time, six groups had the healing time for four days (group I), one week (group II), two weeks (group III), three weeks (group IV), four weeks (group V) and five weeks (group VI), and then the secondary removal torque was measured for each group. To identify the bone formation under fluorescent light, tetracycline (15 mg/kg, IM) were treated on the rabbits of each group. After the second measurement, the rabbits were sacrificed, and 16 slides were made, two or three for each group. The slides were observed under the fluorescent light with light microscope. To find out the change in the secondary removal torque over the primary removal torque in progress of time, the averages of the increase rate of the primary and secondary torque removal force were calculated. Then, to find out if there were any critical differences between the primary removal torque and the secondary removal torque in each group and among the groups, the results were analyzed statistically by paired t- test, one-way ANOVA, and Duncan's Multiple Range Test. Results: In group I and II, secondary removal torque decreased, especially in group I. In group III, IV, V, and VI, secondary removal torque increased critically. Comparing the differences among the groups, the critical difference was shown between group I, II and group III, IV, V, VI. Mineralization at the interface between the bone and implant fixture was identified from the first week, and bone formation was shown more clearly from the second week. Conclusion: If the implant fixture remains unforced for a certain period of time after the fixture has had iatrogenic mobility, re-osseointegration occurs at the surface of the fixture, and for tibias of rabbits, higher re-osseointegration was obtained within two weeks.

The Effect of Various Plaque Control Devices on Roughness and Morphology of Titanium Implant Surface (다양한 치태조절기구가 타이타늄 임프란트의 표면조도와 형태에 미치는 영향)

  • Choi, Seoung-Hwan;Lim, Jeong-Su;Song, In-Taeck;Kim, Hyoug-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.337-350
    • /
    • 1998
  • The purpose of this' study was to compare surface roughness and morphologic changes after use of various plaque control devices to titanium implant surfaces. The study materials were 6 ITI titanium implants($Bonefit^{(R)}$) and 5 plaque control devices. 6 implants were divided into 6 different groups and instrumented by each plaque control devices as follows. 1) Group I : untreated control 2) Group II : Titanium curette(Titanium $curette^{(R)}$, 3i) 80 vertical/horizontal strokes 3) Group III : Plastic curette($Implacare^{(R)}$, Hu-Friedy) 80 vertical/horizontal strokes 4) Group N : Plastic tip-ultrasonic scaler($Amdent^{(R)}$, Amdent) 160 seconds 5) Group V : Rotating interdental brush($Identobrush^{(R)}$, Identoflex) 160 seconds 6) Group VI : Abrasive rubber cup polisher($Zircate^{(R)}$, Prophy paste, Dentsply) 160 sec-onds. All specimens were prepared for evaluation by surface roughness tester, optical stereomicroscopy(OM) and scanning electron microscopy(SEM). The Ra and Rt mean values of the tested specimens were 1) Group I ($Ra=0.170{\pm}0.007{\mu}m$, $Rt=1.297{\pm}0.016{\mu}m$) 2) Group II ($Ra=0.209{\pm}0.006{\mu}m$, $Rt=1.602{\pm}0.110{\mu}m$) 3) Group III ($Ra=0.179{\pm}0.001{\mu}m$, $Rt=1.429{\pm}0.055{\mu}m$) 4) Group IV ($Ra=0.182{\pm}0.005{\mu}m$, $Rt=1.511{\pm}0.085{\mu}m$) 5) Group V ($Ra=0.301{\pm}0.008{\mu}m$, $Rt=1.882{\pm}0.131{\mu}m$) 6) Group VI ($Ra=0.147{\pm}0.010{\mu}m$, $Rt=1.059{\pm}0.021{\mu}m$) In Ra values, experimental group II, V, VI were statistically significant different when compared with control. OM and SEM observation showed that experimental group III, IV were minimal changes when compared with control and group VI was smoothest among other experimental groups. The results suggested that plastic curette and plastic tip-ultrasonic scaler were predictable devices to titanium implant surface.

  • PDF

Color Doppler Ultrasonogram for the Peripheral Vascular disease in Diabetes Patients (당뇨병 환자의 하지 혈관 질환 검사에서 색도플러 초음파의 이용)

  • Lee, Kyung-Tai;Choi, Yun-Sun;Young, Ki-Won;Bae, Sang-Won;Lee, Seung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.1
    • /
    • pp.80-85
    • /
    • 2002
  • Purpose: This study is to assess the involvement of vessels in lower extremity in diabetics, using color doppler ultrasonogram. Materials and Methods: Arteries of both lower extremities were divided into 3 groups-large vessel (above-knee arteries), popliteal vessel, and small vessel(below-knee arteries) -, and evaluated using color doppler ultrasonogram in 60 diabetics. In color doppler ultrasonogram, the wave forms of all vessels were divided into 5 grades; grade I was triphasic wave form, grade II was spectral broadening form, grade III was monophasic wave form, grade IV was pulsus tardus et parvus form, grade V was absence of wave. Grade III, IV, V were grouped into vessel obstruction. We reviewed the correlationships among the degree of the peripheral vascular involvement, duration of dibetes, existence of bilaterality, types of dibetes. Results: Bilateral involvement was high in both lower extremity. Luminal stenosis, vascular calcification and vessel obstruction were high incidence in the patients over ten years of diabetic duration. Prevalence of vascular calcification and vessel obstruction were high in the small vessel of ankle level. But, insulin injection was not related to the incidence of vascular abnormality. Conclusion: Color doppler ultrasonogram seems to be useful for evaluation of peripheral vascular status, decision making for necessity of additional test, periodic follow -up tool in diabetes patients.

  • PDF

A Survey of Current Status on the Science Education of the Special Classroom(School) managed by Firm (산업체(産業體) 부설(附設) 특별학급(特別學級) (학교(學校))의 과학교육(科學敎育) 실태(實態) 조사(調査))

  • Chung, Won-Woo;Yoh, Sao-Dong;Park, Jong-Hwan;Kim, En-Kyung
    • Journal of The Korean Association For Science Education
    • /
    • v.13 no.2
    • /
    • pp.282-295
    • /
    • 1993
  • This study was accomplished to survey of current situation and management of science education in the special classroom(school) managed by firm. The status of management and the evalution of the scientific inquiry ability were taken on workers attending 17 Special Classes and 9 Special Schools located in Taegu City and Kyungpuk Province. As a responses, most students chose the subject "Science"as an option within their limited 8 units credits. About 88.5% of the students were female. About 78.3% of the classes/schools were conducted in the evening only. About 59.4% of teaching staffs were prevailed with female in these classes, and most of them were young, naive, and unexperienced with their major in chemistry and physics. Insufficient facilities and equipments, crowded classes, understaffed instructors, and inappropriated text materials. etc., were reasons for the students not receiving maximum benefit from these classes and schools. In order to evaluate of scientific inquiry ability, 25 items were constructed and administered to 250 students. The processes of scientific inquiry were classified into 5 categories(category I : establishing a subjects, category II : planning a experiments, category III : conducting a experiments. category IV : interpreting a result of experiments, category V : formulating generalization). As the result obtained from the achivement test analysis, the scores for all the students were significantly low, and the scores for girls were higher than those for boys. The results of test in the selected students showed that inquiry abilities in the category I, II and V were higher than those in category III and IV.

  • PDF