• 제목/요약/키워드: III/V ratio

검색결과 224건 처리시간 0.033초

Study on Ohmic resistance of Zn-doping InP using RTA method (RTA 방법에 의해 Zn 도핑된 InP의 오믹저항 특성연구)

  • Kim, H.J.;Kim, I.S.;Kim, T.U.;Kim, S.T.;Kim, S.H;Ki, H.C.;Lee, K.M.;Yang, M.H.;Ko, H.J.;Kim, H.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.237-238
    • /
    • 2008
  • Electrical properties of Pd/Zn/Pd/Au contacts to p-InP were investigated as function of the V/III ratio of p-InP. P-type InP was made by the Zn diffusion into InP and activation process with rapid thermal annealing (RTA) measurement. After activation, the hole concentration was two orders of magnitude higher than that of the sample having only diffusion process. According to transmission line method (TLM) results, the specific contact resistance of p-InP was lower as used InP having the lower V/III ratio. The experimental results represent that the diffusion of Zn in undoped InP deeply related to the equilibrium between interstitials and substitutional Zn is established via indium interstitials.

  • PDF

Studies on the Protein of Korean Soybeans Part 2; Paper Electrophoresis of the Proteins of Korean Soybeans (한국산(韓國産) 대두(大豆)의 단백질(蛋白質)에 관(關)한 연구(硏究) (제2보(第2報)); 여지전기영동법(濾紙電氣泳動法)에 의(依)한 대두단백질(大豆蛋白質)의 분석(分析))

  • Byun, S.M.;Kim, Z.U.;Lee, C.Y.
    • Applied Biological Chemistry
    • /
    • 제7권
    • /
    • pp.85-91
    • /
    • 1966
  • Paper electrophoretic separation of soybean protein using phosphate buffer(pH. 7.6, I. 0.18) was carried out and revealed five components. The ratio of each component extracted with the phosphate buffer was estimated as follows. Component %(aver.) Component I 14.47 Component II 7.22 Component III 4.43 Component IV 71.7 Component V 2.18 Also, each component of phosphate buffer extract was identified as: Component identified Component I identified phaseolin Component II identified glutelin Component III identified $albumin\;{\alpha}$ Component IV identified glycinin Component V identified $albumin\;{\alpha}$ The quantitative determination of the components was performed with twenty five varieties of Korean soybean and turned out to indicate marked difference between the varities in the ratio of the components.

  • PDF

Preparation of PVdF Composite Nanofiber Membrane by Using Manganese-Iron Oxide and Characterization of its Arsenic Removal (망간-철 산화물을 이용한 PVdF 나노섬유복합막의 제조 및 비소 제거 특성 평가)

  • Yun, Jaehan;Jang, Wongi;Park, Yeji;Lee, Junghun;Byun, Hongsik
    • Membrane Journal
    • /
    • 제26권2호
    • /
    • pp.116-125
    • /
    • 2016
  • This study described a synthesis of MF having a arsenic removal characteristics and the fundamental research was performed about the simultaneous removal system of both As(III) and As(V) ions with the composite nanofiber membrane (PMF) based on PVdF and MF materials for the water-treatment application. From the TEM analysis, the shape and structure of MF materials was investigated. The mechanical strength, pore-size, contact angle and water-flux analysis for the PMF was performed to investigate the possibility of utilizing as a water treatment membrane. From these results, the PMF11 showed the highest value of mechanical strength ($232.7kgf/cm^2$) and the pore-diameter of composite membrane was reduced by introducing the MF materials. In particular, their pore diameter decreased with an increase of iron oxide composition ratio. The water flux value of PMF was improved about 10 to 60% compared with that of neat PVdF nanofiber membranes. From the arsenic removal characterization of prepared MF materials and PMF, it was shown the simultaneous removal characteristics of both As(III) and (V) ions, and the MF01, in particular, showed the highest adsorption-removal rate of 93% As(III) and 68% As(V), respectively. From these results, prepared MF materials and PMF have shown a great potential to be utilized for the fundamental study to improve the functionality of water treatment membrane.

Prediction of High Grade Vesicoureteral Reflux in Infants Less than 3 Months with Urinary Tract Infection (3개월 미만 요로감염 영아에서 중증 방광 요관 역류의 예측인자)

  • Yi, Dae-Yong;Kim, Na-Yeon;Cho, Hee-Yeon;Kim, Ji-Eun;Sim, So-Yeon;Son, Dong-Woo;Jeon, In-Sang;Cha, Han
    • Childhood Kidney Diseases
    • /
    • 제12권2호
    • /
    • pp.178-185
    • /
    • 2008
  • Purpose : Our aim was to investigate the predictive factors for detecting grade III-V vesicoureteral reflux(VUR) in young infants less than 3 months with urinary tract infections (UTI). Methods : Data of infants who underwent ultrasonography and VCUG between January 2004 and September 2007 were reviewed. Age, gender, incidence of bacteremia, C-reactive protein(CRP) and imaging studies were compared between group I(grade III-V VUR) and group II (normal or grade I and II VUR) retrospectively. Sensitivity, specificity, positive and negative predictive values, odds ratio, and likelihood ratio of ultrasonography for high grade VUR were evaluated. Results : Among 54 enrolled infants(41 males, 13 females), 14 infants were group I and 40 infants were group II. In the group I, CRP level was significantly higher(6.11$\pm$5.18 vs. 3.27$\pm$3.45, P=0.025), and there were more ultrasonographic abnormal findings(71.4%, vs. 22.5%, P=0.002) compared with group II. However, ultrasonography was the only significant factor after adjusting with logistic regression(P=0.002). Incidence of bacteremia and abnormal DMSA findings were not significantly different in two groups. Sensitivity, specificity, and odds ratio of ultrasonography was 71.4%, 77.5%, 6.9 respectively. Negative predictive value was 88.6% and negative likelihood ratio was 0.37. Ultrasonography had significant negative likelihood ratio for grade III-V VUR, but missed 4 infants with grade III VUR. Conclusion : We could not find any alternative predictive factors to reduce VCUG in detecting high grade VUR. Therefore, VCUG must be considered in young infants less than 3 months with UTI.

A Study of the Change of Hall Effect as a Function of the V/III Ratio in n-GaAs compound Semiconductors

  • Kim, In-Sung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권4호
    • /
    • pp.107-110
    • /
    • 2009
  • In this study, the Hall effect has been studied in n-GaAs samples characterized by V/IIl growth ratios of 25, 50 and 100 and prepared by metal organic chemical vapor deposition. For the Hall effect measurements, the grown samples were cut to a size of 1${\times}$1 cm. The measurements were carried out at room temperature, using Indium contact metal at the four corners of the samples. According to the experimental results, the Schottky effect was not ovservation. Also for the n-GaAs sample of V/Ill 100 ratio the electron drift velocity was very high.

Adsorption Characteristics of Arsenic on Composite Adsorbents using Recycled Aluminium Oxides and $TiO_2$ (재생 알루미늄 산화물과 $TiO_2$의 복합성형체를 이용한 비소 흡착 특성)

  • Min, Kyung-Chul;Lee, Seung-Mok;Kim, Keun-Han;Lee, Hee-Yong;Yang, Jae-Kyu;Park, Youn-Jong
    • Journal of Korean Society on Water Environment
    • /
    • 제28권2호
    • /
    • pp.197-201
    • /
    • 2012
  • The objective of this study was to evaluate the removal efficiency of arsenite and arsenate using composite adsorbents with various mixing ratio of recycled aluminum oxides and $TiO_2$. From batch adsorption experiments, while the removal of As(III) was almost same with 4 different composite samples in the entire pH range, the removal of As(V) was substantially increased as the weight ratio of $TiO_2$ in composite samples reduced and showed anionic adsorption characteristics. Both adsorption of As (III) and As(V) on composite samples followed pseudo-second-order adsorption equation and C-3 showed faster reaction rate for the removal of arsenic. From the adsorption isotherm experiments, Langmuir isotherm explained well and the maximum adsorption capacities of arsenic were obtained with C-1.

The Flora of Mt. Cheongwan (천관산의 식물상)

  • Kim, Dong-Cheol;Chung, Young-Jae
    • Korean Journal of Environment and Ecology
    • /
    • 제25권3호
    • /
    • pp.253-266
    • /
    • 2011
  • The number of vascular plants in Mt. Cheongwan was 323 taxa, which were consisted of 89 families, 221 genera, 270 species, 47 varieties, and 6 formas. Corylopsis coreana belonged in level II of extinction crisis wild plant were found. Six taxa of Korean endemic plants of 6 families, 6 genera, 5 species, and 1 forma were distributed. And also, 40 taxa of floristic specially plants of which 29 in level I, 2 in level II, 6 in level III, 2 in level IV, and finally 1 in level V were recognized. The ratio of naturalized and urbanization index was 3.72 % and 4.14 %, respectively.

GaN Thin Flims Grown by CVPE(Chloride Vapor Phase Epitaxy) Method (CVPE(Chloride Vapor Phase Epitaxy)법에 의한 GaN 박막성장 연구)

  • 오태효;박범진
    • Korean Journal of Crystallography
    • /
    • 제8권2호
    • /
    • pp.81-88
    • /
    • 1997
  • We investigated the CVPE grown of GaN thin films on (0001) sapphire using the $GaCl_3$ and $NH_3$ as source gases. The growth temperatures are ranged 970 to $1040^{\circ}C$ with the various flow rate ratio of source gases. The nitridation treatment was performed using the $NH_3$ gas before the GaN deposition. The optimal growth conditions were determined to be; growth temperature of $1040^{\circ}C$, III/V flow rate ratio of 2, nitridation time of 3 min. The FWHM at the (0002) peak from the XRD analysis was shown to be 0.32 deg. for the sample grown under those conditions. The growth rate was about $40{\mu}m/hr$ at $1040^{\circ}C$.

  • PDF

Estimating the Loss Ratio of Solar Photovoltaic Electricity Generation through Stochastic Analysis

  • Hong, Taehoon;Koo, Choongwan;Lee, Minhyun
    • Journal of Construction Engineering and Project Management
    • /
    • 제3권3호
    • /
    • pp.23-34
    • /
    • 2013
  • As climate change and environmental pollution become one of the biggest global issues today, new renewable energy, especially solar photovoltaic (PV) system, is getting great attention as a sustainable energy source. However, initial investment cost of PV system is considerable, and thus, it is crucial to predict electricity generation accurately before installation of the system. This study analyzes the loss ratio of solar photovoltaic electricity generation from the actual PV system monitoring data to predict electricity generation more accurately in advance. This study is carried out with the following five steps: (i) Data collection of actual electricity generation from PV system and the related information; (ii) Calculation of simulation-based electricity generation; (iii) Comparative analysis between actual electricity generation and simulation-based electricity generation based on the seasonality; (iv) Stochastic approach by defining probability distribution of loss ratio between actual electricity generation and simulation-based electricity generation ; and (v) Case study by conducting Monte-Carlo Simulation (MCS) based on the probability distribution function of loss ratio. The results of this study could be used (i) to estimate electricity generation from PV system more accurately before installation of the system, (ii) to establish the optimal maintenance strategy for the different application fields and the different season, and (iii) to conduct feasibility study on investment at the level of life cycle.

ESTIMATING THE LOSS RATIO OF SOLAR PHOTOVOLTAIC ELECTRICITY GENERATION THROUGH STOCHASTIC ANALYSIS

  • Taehoon Hong;Choongwan Koo;Minhyun Lee
    • International conference on construction engineering and project management
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.375-385
    • /
    • 2013
  • As climate change and environmental pollution become one of the biggest global issues today, new renewable energy, especially solar photovoltaic (PV) system, is getting great attention as a sustainable energy source. However, initial investment cost of PV system is considerable, and thus, it is crucial to predict electricity generation accurately before installation of the system. This study analyzes the loss ratio of solar photovoltaic electricity generation from the actual PV system monitoring data to predict electricity generation more accurately in advance. This study is carried out with the following five steps: (i) Data collection of actual electricity generation from PV system and the related information; (ii) Calculation of simulation-based electricity generation; (iii) Comparative analysis between actual electricity generation and simulation-based electricity generation based on the seasonality; (iv) Stochastic approach by defining probability distribution of loss ratio between actual electricity generation and simulation-based electricity generation ; and (v) Case study by conducting Monte-Carlo Simulation (MCS) based on the probability distribution function of loss ratio. The results of this study could be used (i) to estimate electricity generation from PV system more accurately before installation of the system, (ii) to establish the optimal maintenance strategy for the different application fields and the different season, and (iii) to conduct feasibility study on investment at the level of life cycle.

  • PDF