• Title/Summary/Keyword: IEEE11073

Search Result 63, Processing Time 0.031 seconds

Design and Implementation of Bio-data Monitering System Based on ISO/IEEE 11073 DIM/REST for IoT Healthcare Service (IoT 헬스케어 서비스를 위한 ISO/IEEE 11073 DIM/REST 기반 생체정보 모니터링 시스템 설계 및 구현)

  • Choi, Ju-Hyun;Chun, Seung-Man;Jang, Dong-Hyun;Park, Jong-Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.3-12
    • /
    • 2015
  • Recently, various studies have been attempted to provide a biological information monitoring service through integrating with the web service. The medical information transmission standard ISO/IEEE 11073 PHD defines the optimized exchange protocol ISO/IEEE 11073-20601 based on the No-IP to exchange the biometric information between the ISO/IEEE 11073 agent and the manager. It's system structure based on the No-IP using ISO/IEEE 11073-20601 is not suitable for providing a remote biological information monitoring services. That is because it is difficult to provide to control and manage the biological information measurement devices, which have installed IP protocol stack at the remote. Furthermore, ACSE and CMDISE in ISO/IEEE 11073-20601 are not suitable to provide U-healthcare services based on IoT because they are complicated and difficult to implement it caused by the structural complexity. In order to solve the problems, in this paper, we propose the biological information monitoring architecture based on ISO/IEEE 11073 DIM/REST of IoT environment to provide the biological information monitoring service based on IoT. To do this, we designed biological information monitoring system architecture based on IoT and the message exchange protocol of ISO/IEEE 11073 DIM/REST between the ISO/IEEE 11073 agent and the ISO/IEEE 11073 manager. In order to verify the realistic possibility of the proposed system architecture, we developed the service prototype.

Present Status and Analysis for IEEE 11073 Personal Health Device Specializations (IEEE 11073 개인건강기기별 표준 현황 및 분석)

  • Park, Han-Na;Kim, Seung-Hwan;Yoo, Done-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.469-475
    • /
    • 2012
  • Increasing interest of life expectancy and health has made the u-health industry activating and the several international standard developing organizations(SDO) are dealing with u-health services and technologies. Among them, IEEE 11073 PHD(Personal Health Devices) Work Group is developing standards of personal health device communication for interoperability. There are many studies for introducing SDOs and analyzing the IEEE 11073-20601 standard. However, due to the rare study of PHD standards analysis, there are a lot of difficulties to utilize the standards. In this paper, present status of national and international SDOs including IEEE 11073 standards for PHD will be introduced. Moreover, device specialization standards such as thermometer, weighing scale, glucose meter, blood pressure monitor, electrocardiograph (ECG) etc.. will be analyzed based on the IEEE 11073-20601.

Development of Open H/W-Based IEEE 11073 Agent and Manager for Non-Standard Health Devices (비표준 건강 기기를 위한 오픈 H/W 기반의 IEEE 11073 에이전트 및 매니저 개발)

  • Lee, Jang-Yeol;Jeong, Yeong-Rok;Park, Hee-Dong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.3
    • /
    • pp.595-602
    • /
    • 2016
  • With the evolution and development of many kinds of healthcare devices and techniques, u-health standards have emerged as a major issue. Yet, most legacy medical devices and systems are still being used without deployment of the standards. Therefore, it is required to support backward compatibility for u-health standard-compliant systems to communicate with legacy non-standard medical and healthcare devices. This paper proposes a new scheme to support backward compatibility of IEEE 11073 system by adding a codec module to IEEE 11073 agent. The codec converts data sent by non-standard health devices to IEEE 11073 MDER data. Plus, we implemented the proposed IEEE 11073 agent with an Intel Edison board which is one of popular open source H/W platforms. The IEEE 11073 manager of the proposed system can monitor and control legacy non-standard devices through the proposed agent system. In our experimental results, we examined the proposed system can support interoperability between u-health standard and non-standard devices and contribute to the growth and expansion of u-health services.

Transmitting/Receiving of Standard Health Data Using Bluetooth HDP on the Android Platform (안드로이드에서 블루투스 HDP를 이용한 표준건강정보의 송수신)

  • Park, Young-Jin;Cho, Hui-Sup;Son, Jong-Wuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.5
    • /
    • pp.464-470
    • /
    • 2013
  • These days, with increasing interest about the health care, research about standard for transmitting/receiving data of health device has been actively conducted. Standardization and testing / certification is underway through the IEEE 11073 PHD, Health Level Seven and the Continua Health Alliance, it'll continue to be more research and experiments in the future. In this paper, we introduce the IEEE 11073 PHD standards for exchange of remote health information and the Bluetooth Health Device Profile(HDP) for health device profile of the Bluetooth technology, also we conducted experiments about exchange health information between health device and smart device which are adapted the IEEE 11073 PHD and Bluetooth HDP. Transmitting/receiving of the IEEE 11073 PHD standard protocol using the Bluetooth HDP profile between health device and smart device can be known by this experiment, and it expect to implement variety of remote medical services through health device supporting these standards in future.

Mobile Healthcare System Based on ISO/IEEE11073, HL7 (ISO/IEEE11073, HL7 기반 모바일 헬스케어 시스템)

  • Jeon, Jae-Hwan;Kang, Sung-In;Kim, Gwan-Hyung;Choi, Sung-Wook;Oh, Am-Suk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.247-249
    • /
    • 2012
  • 본 논문에서는 최근 IT 기술의 집약체인 스마트폰을 중심으로 국제표준인 ISO/IEEE11073, HL7을 준용하여 다양한 PHD(Personal Health Device)들과의 연결성을 지원하는 모바일 게이트웨이 플랫폼을 구축을 통하여 홈&모바일 헬스케어 분야에서 새로운 모델을 제시하고자한다. 아울러 핵심 기술 요소인 ISO/IEEE11073, HL7 적용을 통해 홈 헬스케어용 센서 기기에 대한 각종 기술을 축적 하고 최근에 활용이 보편화되고 있는 스마트폰을 활용한 헬스케어 플랫폼 적용으로 우수성을 확보하고자 한다.

  • PDF

A Study on the Mapping Method of IEEE 11073 DIM/HL7 v3 RIM for Smart health-care (스마트폰 헬스케어를 위한 IEEE 11073 DIM/HL7 v3 RIM 매핑 방법에 대한 연구)

  • Kim, Jong-Pan;Jeon, Jae-Hwan;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.842-845
    • /
    • 2012
  • 의료기기는 헬스케어 서비스를 위한 필수요소로 최근 의료와 관련된 스마트폰 애플리케이션의 증가와 함께 스마트폰과 연결되는 의료기기를 활용한 스마트 헬스케어가 대두되고 있다. 이러한 스마트 헬스케어는 현재 ISO/IEEE 11073 표준을 통해 의료기기와 게이트웨이를 연결하여 임상정보를 전송하고 게이트웨이는 HL7 CDA 표준 문서를 통해 전자 건강 기록 및 개인 건강 기록 시스템, 임상 워크플로우 및 임상 의사 결정 지원 시스템과 같은 유형의 의료 서비스 시스템과 연동하는 솔루션이다. ISO/IEEE 11073은 DIM(Domain Information Model)이라는 정보 모델을 기반으로 하며 HL7 v3인 CDA는 RIM(Reference Information Model)이 있기 때문에 상이한 인터페이스간의 매핑 매커니즘을 필요로 한다. 이에 본 논문에서는 스마트폰 환경에서 의료 응용 애플리케이션에서의 효율적인 의료기기 데이터 운용을 위해 RMIM(Refined Message Information Model) 기반의 IEEE 11073 DIM/HL7 v3 RIM 표준 인터페이스 변환 방법을 제안한다.

  • PDF

Complexity Analysis for Implementation of the ISO/IEEE 11073 PHD Standards (ISO/IEEE 11073 PHD 표준 구현을 통한 복잡도 분석)

  • Kim, Sang-Kon;Yoo, Done-Sik;Kim, Tae-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.307-312
    • /
    • 2012
  • In this paper, we perform a complexity analysis for implementation of the ISO/IEEE 11073 Personal Health Device (PHD) standards in order to check the required system resources when ISO/IEEE 11073 PHD standards are implemented on the embedded system. Base on the implemented programs complying the PHD standards for a weighing scale, a blood pressure monitor, and a glucose meter among the various personal health devices, we make a pseudo-code. And then from the two different points of view such as program memory space and data memory space, we make a complexity analysis model. Because system resources or capability are strongly restricted in the personal health devices, our research work is very useful to estimate the required system resources.

A Study of Vital Sign(ECG) Measuring based on ISO IEEE11073-20601 (ISO/IEEE11073-20601 기반의 생체신호(ECG)측정 연구)

  • Park, Kwang-Ho;Joo, Moon-Il;Oh, Dong-Eun;Kim, Tae-Woong;Kim, Hee-Cheol
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.209-210
    • /
    • 2012
  • 최근 u-헬스 중심으로 건강 건강관리를 위해 수많은 PHD(Personal Healthcare Device)가 개발, 상용화 되고 있다. 하지만 대부분의 기기(PHD)들은 각각의 자체적인 프로토콜을 사용하여 통신을 하고 있기 때문에 타 기기간의 상호호환의 어려움이 있다. 이러한 문제점을 개선하고자 ISO와 IEEE에서는 표준화 프로토콜 IEEE11073-20601을 제정하였다. 본 논문에서는 표준 프로토콜 ISO/IEEE11073-20601을 이용하여, ECG(Electrocardiogram) 신호를 수신한 데이터를 Android OS 기반 태블릿에서 보여주고자 한다.

  • PDF

Complexity Analysis for Implementation of the PM-store of ISO/IEEE 11073 PHD Standards (ISO/IEEE 11073 개인건강기기 표준의 PM-store 구현을 위한 복잡도 분석)

  • Kim, Sang-kon;Lee, Chang-ki;Kim, Tae-kon;Hwang, Hee-joung
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.447-454
    • /
    • 2015
  • In this paper, the complexity analysis for implementation of the PM-store is performed in terms of the number of instruction cycles which is executed by CPU in a personal health device(PHD) in order to transfer the large amount of the periodically generated measurement data using the PM-store concept defined in ISO/IEEE 11073 PHD standards. We propose an analytic model that is focused on the number of instruction cycles executed by CPU depending on the PM-store hierarchy.

Implementation of ISO/IEEE 11073-10404 Monitoring System Based on U-Health Service (유헬스 서비스 기반의 ISO/IEEE 11073-10404 모니터링 시스템 구현)

  • Kim, Kyoung-Mok
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.6
    • /
    • pp.625-632
    • /
    • 2014
  • The u-health service is using portable device such as smart device and it consists of small computing device. The u-health service carry out same performance with desktop computer. We designed message structure based on Bluetooth HDP. This message structure is used to transmit patient's biometric data on the smart device of medical team, patient and family over the mobile network environment. ISO/IEEE 11073 PHD standard was defined based on the method of communication between the agent and the manager. And We are confirmed the reliable transmission of biometric data at the smart device by implementing the android OS based patient information monitoring application to check the status of patient for medical team, patient and family.