• Title/Summary/Keyword: IEC code

Search Result 73, Processing Time 0.229 seconds

Study on Selftest Requirements in Cryptographic Module Validation Program with FIPS-OpenSSL Source Code Analysis (FIPS-OpenSSL 코드 분석을 통한 암호모듈 자가시험 보안요구사항 분석)

  • Seo, Seog Chung
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.5
    • /
    • pp.985-996
    • /
    • 2019
  • This paper analyzes the source code of FIPS-OpenSSL cryptographic module approved as FIPS cryptographic module in USA and shows how the selftest requirements are implemented as software cryptographic library with respect to pre-operational test and conditional tests. Even though FIPS-OpenSSL follows FIPS 140-2 standard, lots of security requirements are similar between FIPS 140-2 and Korean cryptographic module validation standards. Therefore, analysis from this paper contributes to help Korean cryptographic module vendors develop correct and secure selftest functions on their own cryptographic modules, which results in reducing the test period.

Test Assertion Language for Unit Test : Design and Implementation (단위 테스트를 위한 테스트 어서션 언어 설계 및 도구 구현)

  • Shin, Woo-Chang
    • Journal of Information Technology Services
    • /
    • v.10 no.4
    • /
    • pp.205-218
    • /
    • 2011
  • Unit testing which is the first task to perform software testing has a major impact on reducing s/w development cost and improving s/w quality. In order to make unit testing become the formal procedure rather than ad-hoc tasks performed by developer, the language-neutral measures are necessary in the programming which is able to specify the test cases. This paper presents a test assertion language for the language-neutral specification of the test cases. The suggested language is based on the ISO/IEC 24709-1, but it supports object oriented features and can describe test cases for unit testing. The test cases that are specified by the language can be used for generating test oracle source codes by test oracle generation tools.

ISO에서의 정보보호관리 국제 표준화 동향

  • 홍기향;김정덕
    • Review of KIISC
    • /
    • v.14 no.2
    • /
    • pp.1-5
    • /
    • 2004
  • ISO의 정보보호관리 표준은 ISO/IEC JTC1/SC27 WG1에서 표준화를 진행하고 있으며, 현재까지 제정된 정보보호관리 표준으로는 ISO 13335 MICTS와 ISO 17799 Code of practices for information security management 등이 있다. ISO 13335는 정보보호관리 모델 및 기술에 대한 가이드를 제공하는 표준이고, ISO 17799는 정보보호관리 통제에 대한 가이드를 제공하는 표준이다. 최근 동향으로는 ISMS(Information Security Management Systems)국제표준화 작업이 시작될 것으로 예상되며, WG1에서 작업 중인 정보보호관리 표준 간 유사성을 배제하고 통합된 체제를 만들기 위한 로드맵 작성 작업이 진행 중에 있다. 인터넷의 확산과 정보화의 역기능 증가에 따라 능동적인 정보보호관리체계의 수립을 위하여, 우리나라도 정보보호관리 표준의 제정 과정에 적극적으로 참여할 뿐 아니라 국내 많은 조직에서 정보보호관리 표준이 적용되어 국가적인 정보보호관리 수준이 향상될 수 있도록 할 필요가 있다.

Development of the Preventive Diagnostic Expert System of Gas in Oil for Power Transformer (변압기 예방진단을 위한 유중가스 전문가 시스템 구축 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;Sun, J.H.;Kim, C.G.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1019-1021
    • /
    • 1999
  • In this paper, we describe the design and appliance of the preventive diagnostic expert system of gas in oil for power transformer. This expert system is developed to use expert system development tool; Element Expert (NEURON DATA Inc.) Analysis is developed by four diagnose methods. In first, the standard of KEPCO is applied. It classifies the state of transformer by four level: Normal, warning, abnormal and danger. And the others are gas pattern methods, IEC code method, and Dornen & Roger Ratio method and applied later. These latter methods analyse the cause of result. Inference engine was designed with Element Expert. In last, we operate the system with sample data and we can obtain the correctly inferred result for the state of transformer.

  • PDF

Comparison and Analysis of Domestic and Foreign Standard for electrical equipment installation of amusement park and ride (유원시설 전기설비 설치에 대한 국내외 규정 비교 분석)

  • Kim, Gi-Hyun;Kim, Chong-Min;Kim, Han-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.378-382
    • /
    • 2004
  • This paper gives information which is applied to install the electrical equipment of amusement park and ride. For analyzing the standard of electrical equipment installation, we research the related regulation of National Electrical Code(2002), IEC 60364-series and Technical standards for Electrical facilities of internal standard. Among electrical equipments of amusement park and ride, especially we study the transformer vaults, overcurrent protection and ground protection of electrical equipment. So we the furnished the installation information of transformer vaults, overcurrent and ground protection at amusement park and ride.

  • PDF

Partial Safety Factor of Offshore Wind Turbine Pile Foundation in West-South Mainland Sea (서남해안 해상풍력단지 말뚝기초의 부분안전계수)

  • Yoon, Gil Lim;Kim, Sun Bin;Kwon, O Soon;Yoo, Moo Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1489-1504
    • /
    • 2014
  • This paper is aimed to suggest a site specific partial safety factor of offshore wind turbine (OWT) pile foundation design for the offshore wind turbine complex at a West-South mainland sea in Korea. International offshore wind design standards such as IEC, GL, DNV, API, ISO and EUROCODE were compared with each partial safety factor and resistance factor. Soil uncertainty analysis using a large number of soil data sampled was carried out, and their results were adapted to estimate partial safety factor of OWT pile foundation through reliability analyses. The representative partial safety factor has been estimated as 1.3. When a proposed partial factor is willing to use to other sites, it is recommended that further studies on code calibration are required to validate their accuracy using more site characterization data.

A Study on the Reliability of Failure Diagnosis Methods of Oil Filled Transformer using Actual Dissolved Gas Concentration (유중가스농도를 이용한 유입식 변압기 고장진단 기법의 신뢰성에 관한 연구)

  • Park, Jin-Yeub;Chin, Soo-Hwan;Park, In-Kyoo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.114-119
    • /
    • 2011
  • Large Power transformer is a complex and critical component of power plant and consists of cellulosic paper, insulation oil, core, coil etc. Insulation materials of transformer and related equipment break down to liberate dissolved gas due to corona, partial discharge, pyrolysis or thermal decomposition. The dissolved gas kinds can be related to the type of electrical faults, and the rate of gas generation can indicate the severity of the fault. The identities of gases being generated are using very useful to decide the condition of transformation status. Therefore dissolved gas analysis is one of the best condition monitoring methods for power transformer. Also, on-line multi-gas analyzer has been developed and installed to monitor the condition of critical transformers. Rogers method, IEC method, key gas method and Duval Triangle method are used to failure diagnosis typically, and those methods are using the ratio or kinds of dissolved gas to evaluate the condition of transformer. This paper analyzes the reliability of transformer diagnostic methods considering actual dissolved gas concentration. Fault diagnosis is performed based on the dissolved gas of five transformers which experienced various fault respectively in the field, and the diagnosis result is compared with the actual off-line fault analysis. In this comparison result, Diagnostic methods using dissolved gas ratio like Rogers method, IEC method are sometimes fall outside the ratio code and no diagnosis but Duval triangle method and Key gas method is correct comparatively.

A New MPEG Reference Model for Unified Speech and Audio Coding (통합 음성/오디오 부호화를 위한 새로운 MPEG 참조 모델)

  • Song, Jeong-Ook;Oh, Hyen-O;Kang, Hong-Goo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.74-80
    • /
    • 2010
  • Speech and audio codecs have been developed based on different type of coding technologies since they have different characteristics of signal and applications. In harmony with a convergence between broadcasting and telecommunication system, international organizations for standardization such as 3GPP and ISO/IEC MPEG have tried to compress and transmit multimedia signals using unified codecs. MPEG recently initiated an activity to standardize the USAC (Unified speech and audio coding). However, USAC RM (Reference model) software has been problematic since it has a complex hierarchy, many useless source codes and poor quality of the encoder. To solve these problems, this paper introduces a new RM software designed with an open source paradigm. It was presented at the MPEG meeting in April, 2010 and the source code was released in June.

A Hardware Design of Ultra-Lightweight Block Cipher Algorithm PRESENT for IoT Applications (IoT 응용을 위한 초경량 블록 암호 알고리듬 PRESENT의 하드웨어 설계)

  • Cho, Wook-Lae;Kim, Ki-Bbeum;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1296-1302
    • /
    • 2016
  • A hardware implementation of ultra-lightweight block cipher algorithm PRESENT that was specified as a block cipher standard for lightweight cryptography ISO/IEC 29192-2 is described in this paper. Two types of crypto-core that support master key size of 80-bit are designed, one is for encryption-only function, and the other is for encryption and decryption functions. The designed PR80 crypto-cores implement the basic cipher mode of operation ECB (electronic code book), and it can process consecutive blocks of plaintext/ciphertext without reloading master key. The PR80 crypto-cores were designed in soft IP with Verilog HDL, and they were verified using Virtex5 FPGA device. The synthesis results using $0.18{\mu}m$ CMOS cell library show that the encryption-only core has 2,990 GE and the encryption/decryption core has 3,687 GE, so they are very suitable for IoT security applications requiring small gate count. The estimated maximum clock frequency is 500 MHz for the encryption-only core and 444 MHz for the encryption/decryption core.

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.