• Title/Summary/Keyword: IEC code

Search Result 73, Processing Time 0.023 seconds

A study on OID Resolution System for RFID, USN (RFID, USN에서의 OID 해석시스템에 관한 연구)

  • Yi, Seung-Jai;Jin, Chung-Hee;Kim, In-Hye;Noh, Enu-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.210-214
    • /
    • 2010
  • Standard about OID(Object Identifier) to implement on Internet is discussed at ITU-T, ISO/IEC. The OID should be stored and searched for object on Internet, which is called 'ORS(OID Resolution System)'. The ORS is made by international standard for identifying RFID code types, and in the future would be discussed for USN, u-Health, etc. Therefore, this paper describes the current status of the international standard discussing ORS concept, system structure and protocol, the present issue of the ORS used for RFID and the method for USN services.

A review on the stray current countermeasures of DC electric railways(1) Europe and Australia (직류전기철도의 누설전류 방지대책에 대한 고찰(1) 유럽과 호주)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1075-1076
    • /
    • 2006
  • The wide spread of DC electric railway systems such as urban rapid transits including heavy rail and light rail transits has significant ramification as the stray currents from return conductor rails can cause the electrochemical interference, that is, the electrolytic corrosion of both rails and outside underground metallic infrastructures. The immature understanding of either the railway authority who is responsible for establishing the necessary provisions at the design stage or the affected parties makes it difficult to prepare the optimum range of solutions for the long-pending interference problem. In advanced countries, however, numerous assessment studies have been carried out on the stray current interference, by which protective standards and regulations are provided under the collaboration and agreement of the related parties. In this paper, we introduce a european standard from IEC, namely, "IEC 62128-2:2003 railway applications-fixed installations -part 2: protective provisions against the effects of stray currents caused by d.c. traction systems" and a "Code of Practice" produced by Victorian electrolysis committee (VEC) based on "Electricity Safety Act 1998" and "Electricity safety (stray current corrosion) regulations 1999" of Victoria state, Australia.

  • PDF

Proposal and Implementation on Non-Repudiation of Origin for DNP3 (DNP3에 적합한 발신 부인 방지 기법 제안과 그 구현)

  • Yu, Ki-Soon;Song, Kyoung-Young;Jang, Min-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.5
    • /
    • pp.815-825
    • /
    • 2015
  • DNP3(Distributed Network Protocol) is one of the most representative protocols which is used in SCADA(Supervisory Control and Data Acquisition) system. IEC 62351 is listing the integrity, confidentiality, availability and non-repudiation or accountability as the security requirement. However, IEEE Std. 1815 that is DNP3 standards does not define a mechanism for non-repudiation or accountability. In this paper, we propose a non-repudiation of origin technique about the sender of critical ASDU and implement the proposed scheme using software such as OpenSSL and SCADA source code library.

Structural Design of a 750kW Composite Wind Turbine Blade (750kW급 풍력발전기용 복합재 블레이드의 구조설계)

  • Jung C.K.;Park S.H.;Han K.S.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.18-21
    • /
    • 2004
  • A GFRP based composite blade was developed for a 750kW wind energy conversion system of type class I. The blade sectional geometry was designed to have a general shell-spar structure. The load cases specified in the IEC61400-1 international specification were considered. For withstanding all relevant extreme loads, the structural analysis for the complete blade was performed using a commercial FEM code. The static load carrying capacity, buckling stability, blade tip deflection and natural frequencies at various rotational speeds were evaluated to satisfy the strength requirements in accordance with the IEC61400-1 and GL Regulations. For designing a lightweight blade, the thickness and the lay-up pattern of the skin-foam sandwich structures were optimized iteratively using the DOT program T-bolts were used for joining the blade root and the hub, which were modeled using a 3D FE volume model. In order to confirm the safety of the root connection, the static stresses of the thick root laminate and the steel. bolts were predicted by taking account of the bolt pretension and the root bending moments. The calculated stresses were compared with the material strengths.

  • PDF

Refactoring Effectiveness Analysis for Software Quality Enhancement : using AIS Mediation Server Program (소프트웨어 품질 향상을 위한 리팩토링 효과 분석 : AIS 중개 서버 프로그램을 대상으로)

  • Lee, Seo-Jeong;Lee, Jae-Wook;Hwang, Hoon-Kyu;Lee, Jang-Se
    • Journal of Navigation and Port Research
    • /
    • v.36 no.5
    • /
    • pp.363-370
    • /
    • 2012
  • Recently, International Maritime Organization has been developing e-navigation implementation strategy plan, which is focused on various services for vessel safety navigation. Then, different kinds of software will be developed in maritime area and with this, the quality issues are to be expected becoming more important. In this paper, we adopt software refactoring techniques to reduce the complexity of structure on source code level. It makes software program more effective to understand and modify, without any change of outward behavior. The existing AIS broadcast server program is used as an example for our trial, and calculating coupling and cohesion metric are introduced to analyze the refactoring effect, taking account of the maintainability of IEC/ISO9126 software quality standards.

A Study on the Security Framework Design for Stable Operation of Critical Infrastructure Service (주요기반시설 서비스의 안정적 운영을 위한 보안 프레임워크 설계에 관한 연구)

  • Lee, Suyeon;Yoo, Jiyeon;Lim, Jongin
    • Journal of Information Technology Services
    • /
    • v.15 no.4
    • /
    • pp.63-72
    • /
    • 2016
  • Critical infrastructure has been operating in a closed environment with a completely separate information system and in the private area. However, with the current ICT environment changes due to convergence and open platforms it has increased the threats and risks to critical infrastructure. The importance of cyber security is increasing in the infrastructure control system, such as the outbreak of Ukraine blackout in 2015 by a malicious code called 'black energy'. This thesis aims to recognize the importance and necessity of protecting the critical infrastructure service, designing a security framework reflecting environmental and characteristic changes, and analyzing the management system suitable for a security framework. We also propose a theoretical basis for constructing a new security framework by comparing and analyzing seven international security management system standards, such as NIST 800-82 and IEC 62443-2-1, which are used in the control system. As a result, the environment surrounding critical infrastructure changes with the characteristics of connectivity, openness, and finality was studied, and as a response to this, many scholars and institutions present critical infrastructure security frameworks as cycle enhancement type structures, risk management structures, and management domain expansion structures. In response, the security framework encompassing these structures, CISF (Critical Infrastructure Security Framework), was designed. Additionally, through the security related international standard and criterion analysis, as a newly designed security standard suitable for CISF, IEC 62443-2-1 is reviewed and suggestions are made.

Seismic and Stress Analysis of 72.5kV GIS for Technical Specification of KEPCO (72.5kV GIS 전력 장비의 KEPCO 기준 내진 및 응력 해석)

  • Lee, Jae-Hwan;Kim, Young-Joong;Kim, So-Ul;Bang, Myung-Suk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.207-214
    • /
    • 2017
  • High voltage electric power transmitter GIS(Gas Insulated Switchgear) above 72.5kV needs to satisfy domestic Korean peninsular standard(ES-6110-0002) in KEPCO with respect to normal and special operation conditions which include internal gas pressure, dead weight, wind and seismic load. Some other requirements not described in Korean standard can be applied from other international standards such as IEC(International Electronical Committee) 62271-203 and 62271-207. The GIS is a kind of pressure vessel structure made of aluminum and filled with SF6 gas of internal pressure 0.4~0.5MPa. Finite element analysis of GIS is performed with such operational loads including seismic loading and the stability and reliability is determined according to ASME BPVC(Boiler and Pressure Vessel Code) SEC. VIII standard where the allowable stress level of the pressure vessel is suggested. The result shows that the stress of GIS is satisfied the allowable stress level and the safety factor is about 2.3 for Korean peninsular standard.

A Comparison on Detected Concentrations of LPG Leakage Distribution through Actual Gas Release, CFD (FLACS) and Calculation of Hazardous Areas (가스 누출 실험, CFD 및 거리산출 비교를 통한 LP가스 누출 검지농도 분포에 대한 고찰)

  • Kim, Jeong Hwan;Lee, Min-Kyeong
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.102-109
    • /
    • 2021
  • Recently, an interest in risk calculation methods has been increasing in Korea due to the establishment of classification code for explosive hazardous area on gas facility (KGS CODE GC101), which is based on the international standard of classification of areas - explosive gas atmospheres (IEC 60079-10-1). However, experiments to check for leaks of combustible or toxic gases are very difficult. These experiments can lead to fire, explosion, and toxic poisoning. Therefore, even if someone tries to provide a laboratory for this experiment, it is difficult to install a gas leakage equipment. In this study we find out differences among actual experiments, CFD by using FLACS and calculation based on classification code for explosive hazardous area on gas facility (KGS CODE GC101) by comparing to each other. We develpoed KGS HAC (hazardous area classification) program which based on KGS GC101 for convenience and popularization. As a result, actual gas leak, CFD and KGS HAC are showing slightly different results. The results of dispersion of 1.8 to 2.7 m were shown in the actual experiment, and the CFD and KGS HAC showed a linear increase of about 0.4 to 1 m depending on the increase in a flow rate. In the actual experiment, the application of 3/8" tubes and orifice to take into account the momentum drop resulted in an increase in the hazardous distance of about 1.95 m. Comparing three methods was able to identify similarities between real and CFD, and also similarities and limitations of CFD and KGS HAC. We hope these results will provide a good basis for future experiments and risk calculations.

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

Improvement of Application Criteria of Pull Code Switch for Conveyor Accident Prevention (컨베이어 사고 예방을 위한 풀 코드 스위치 적용기준 개선)

  • Seo, Jae Min;Park, Ji Hoon;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.153-158
    • /
    • 2019
  • It is estimated that about 2,515 persons have been injured by conveyor for the past five years(2013 ~ 2017). Conveyors used in various industrial sites for transporting iron ore, coal, courier goods, etc., have various incidents such as a worker putting on or pulling a part of the body or work clothes on the driving part during maintenance. It is necessary for preventing similar accidents to conduct various researches. In order to propose the basis for revising laws and standards for the safety standards of the full cord switch to prevent conveyor accidents, this study compares Korea's Industrial Safety and Health Law (KISHL) with those of IEC, EN, Canada, and Australia. In addition, surveys of conveyor use plant and full cord switch domestic and foreign manufacturers was conducted. In this study, domestic and overseas related laws and technical standards compare and analyze to prevent conveyor accidents. In addition, we propose extension of safety certification for full code switch, establishment of safety inspection standard, and improvement of working method regulation through actual working condition investigation. It can be used as a basis for revising the occupational safety and health regulation and related notices, and thus contributing to enhancing the safe atmosphere of the conveyor business and improving the safety consciousness of the concerned persons.