• Title/Summary/Keyword: IEC code

Search Result 73, Processing Time 0.026 seconds

Evaluation of proficiency and improvement of accuracy on the analysis of brominated flame retardants (PBDEs) in ABS polymer (ABS수지 중 polybrominated diphenyl ether(PBDE)류 분석 숙련도 평가 및 정확도 향상)

  • Ryu, Jehoon;Kim, Dalho
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.446-452
    • /
    • 2015
  • In order to evaluate and improve the ability of Korean testing laboratories to measure Polybrominated diphenyl ethers in acrylonitrile-butadiene-styrene (ABS), a proficiency test was organised by Korea Research Institute of Standards and Science (KRISS) based on ISO/IEC 17043. The proficiency test material used was 10 g of a granular ABS fortified with a mixture of congeners of PBDE (BDE-154, 183, 206, 209). Homogeneity and stability were investigated to assess the adequacy of the test material. The certified value established by KRISS based on the national reference was used for assigned value of each PBDE. The test materials were distributed to the 16 participating laboratories. The participating laboratories were requested to analyse the samples employing the methods used in their routine analysis. Each laboratory was given it’s own code to secure the anonymity. Participants results were evaluated with z-scores according to ISO/IEC 17043. The standard deviation for proficiency assessment was set by standard deviation of the participants results except for outlier. The results, the laboratory's performance and improvement of accuracy were discussed.

Implementation of RFID System Type C Using VHDL (VHDL을 이용한 REID 시스템 Type C의 구현)

  • Cho, Kyung-Chul
    • Journal of Digital Contents Society
    • /
    • v.7 no.3
    • /
    • pp.147-151
    • /
    • 2006
  • In recent years, the Internation Standard ISO/IEC 18000-6 is announced and a new scheme of Type C is added to conventional standard. Among the RFID systems the ISO/IEC 18000-6 standard is the most interesting to companies due to its potential market growth. The operating frequency is between 860-960 MHz, and three kinds of RFID system are included in the standard, i.e. type A, B and C. In this paper, we implemented the data frame of type C with baseband coding using VHDL. The data frame is encoded based on Miller code and FM0. We showed the implementation results with waveforms. The data frame was proved that it is properly implemented by the experiment of transmission and receiving operation.

  • PDF

A study on RFID code system for Traceability of agro-livestock products (농축산물 생산 이력 정보 추적을 위한 RFID 코드체계에 관한 연구)

  • Park, Min-Ho;Ko, Sung-Seok
    • The Journal of Society for e-Business Studies
    • /
    • v.12 no.2
    • /
    • pp.95-110
    • /
    • 2007
  • The agro-livestock industry is composed of a complicated supply chain and the customer‘s interest in safety of agro-livestock products is increasing. In order to provide customer with the accurate information about the history of product, and make good use of these information, traceability systems based on RFID technology were implemented and are planned. It is, however, difficult to make the efficient flow of information and to enhance or expand the traceability system because of the lack of the standard of RFID code system. To overcome this problem, we propose a RFID code system for the traceability of argo-livestock products on the basis of ISO/IEC 15459 KKR code system.

  • PDF

Design and Implementation of a Decompiler for Verification and Analysis of Intermediate Code in C++ Compiler (C++ 컴파일러에서 중간코드의 검증과 분석을 위한 역컴파일러의 설계 및 구현)

  • Bae Sung-Kyun;Kim Young-Keun;Lee Yang-Sun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.1405-1408
    • /
    • 2006
  • C++ 언어는 객체지향 프로그래밍 언어로, 기존의 C++ 프로그램은 각각의 플랫폼에 따른 컴파일러를 통해 목적기계의 코드(object code)로 변환되므로 실행되는 플랫폼에 의존적인 단점이 있다. 이러한 단점을 보완하는 방법으로 스택기반의 가상기계와 가상기계의 입력형태인 중간코드를 이용하는 기법이 있다. EVM(Embedded Virtual Machine)은 ANSI C, ISO/IEC C++ 언어와 SUN사의 Java 언어 등을 모두 수용할 수 있는 임베디드 시스템 기반의 가상기계이며, EVM에서 실행되는 중간코드인 SIL(Standard Intermediate Language)은 객체지향 언어와 순차적인 언어를 모두 수용하기 위한 명령 코드의 집합으로 설계되어 있다. 본 논문에서는 C++ 컴파일러를 통해 생성된 SIL 코드가 올바른지 검증하고 원시코드의 분석을 용이하게 하기 위해서 SIL 코드를 어셈블리 코드와 유사한 형태의 재 표현된 C++ 프로그램으로 역컴파일하는 시스템을 설계하고 구현하였다.

  • PDF

ISPLC:Intelligent Agent System based Software Programmable Logic Control (ISPLC: 지능적인 에이전트 기반 소프트웨어 PLC)

  • 조영임;심재홍
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.11b
    • /
    • pp.557-560
    • /
    • 2003
  • In this paper, we developed an editor and running engine for the SoftPLC. LD is the most popular standard IEC 1131-3 PLC language in Korea and used over 90% among the 5 PLC languages. In this paper, we have developed the ISPLC(Intelligent Agent System based Software Programmable Logic Controller). In ISPLC system, LD programmed by a user is converted to IL, which is one of intermediate codes, and IL is converted to the standard C code which can be used in a commercial editor such as visual C++. In ISPLC, the detection of logical error in high level programming(C) is more efficient than PLC programming itself. ISPLC provide easy programming platform to such beginner as well as professionals. The study of code conversion of LD-> U->C is firstly tried in the world as well as KOREA.

  • PDF

Testbench Implementation for FPGA based Nuclear Safety Class System using OVM

  • Heo, Hyung-Suk;Oh, Seungrohk;Kim, Kyuchull
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.566-571
    • /
    • 2014
  • A safety class field programmable gate array based system in nuclear power plant has been developed to improve the diversity. Testbench is necessary to satisfy the technical reference, IEC-62566, for verification and validation of register transfer level code. We use the open verification methodology(OVM) developed by standard body. We show that our testbench can use random input for test. And also we show that reusability of block level testbench for the integration level testbench, which is very efficient for large scale system like nuclear reactor protection system.

Hydraulic Efficiency measurement of small turbine and example of it's analysis (소수력수차의 효율측정과 분석사례)

  • Kim, Eung-Tae;Jung, Yong-Chea;Park, Jang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.748-756
    • /
    • 2005
  • The Purpose of this writing is a presentation of small turbine efficiency measuring method, applicable new technology, and several analysis result for real turbine. Measurement methods of hydraulic efficiency written in here are extracted from small turbine applicable international code(IEC, ASME). It includes brief synopsis of 'Current meter method' and 4 other methods and ASFM as a new small turbine applicable technology. And several analysis of test result are for recently performed domestic small turbine result in korea. Through this presentation of extracted code, I hope that it make other small turbine concerner be familiar to perform an efficiency test. for small turbine. And, some analysis of that, make other to feel the importance of efficiency test.

  • PDF

A Study of the Preventive Diagnostic Algorithm of Gas in Oil for Power Transformer (가스분석을 이용한 변압기의 이상진단 알고리즘 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;You, Y.P.;Sun, J.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1903-1905
    • /
    • 2000
  • Power transformers have a tendency of ultra-high voltage capacity as power demand increases day after day KEPCO also will have plan to supply transmission power from 345KV to 765KV in the early of 2000. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important in power transformers because of economic loss and its spreading effect. This study presents the algorithm for transformer oil analysis used KEPCO code, IEC code, gas pattern method and Dornenburg & Roger Ratio method. We also describe the MMI display of expert system programmed by Element Expert Tool(Neuron Data Inc.).

  • PDF

A Study on Classification of Explosion Hazardous Area for Facilities using Lighter-than-Air Gases (공기보다 가벼운 가스 사용시설의 폭발위험장소 설정방안에 대한 연구)

  • Yim, Ji-Pyo;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • There have been controversies over whether explosion hazardous area(EHA) should be classified for facilities which use lighter-than-air gases such as city gas, hydrogen and ammonia. Two view points are confronting each other: an economic piont of view that these gases are lighter than air and disperse rapidly, hence do not form EHA upon release into the atmosphere, and a safety point of view that they are also inflammable gases, hence can form EHA although the extent is limited compared to heavy gases. But various standards such as KS, IEC, API, NFPA do not exclude light gases when classifying EHA and present examples of EHA for light gas facilities. This study calculates EHA using the hypothetical volume in the IEC code where the hole sizes required for the calculation were selected according to various nominal pipe sizes in such a way to conform to the EHA data in the API code and HSL. Then, 25 leakage scenarios were suggested for 5 different pipe sizes and 5 operating pressures that cover typical operating conditions of light gas facilities. The EHA for the minimum leakage scenario(25 mm pipe, 0.01MPa pressure) was found to correspond to a hypothetical volume larger than 0.1 $m^3$(medium-level ventilation). This confirms the validity of classifying EHA for facilities using lighter-than-air gases. Finally, a computer program called HACPL was developed for easy use by light gas facilities that classifies EHA according to operating pressures and pipe sizes.

Efficiency Measurement Method and Simplification of Program (프로그램의 효율성 측정 방법과 간소화)

  • Yang, Hae-Sool
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.1
    • /
    • pp.49-62
    • /
    • 1998
  • Softwares which have many functions to satisfy user's requirements is developing. But generally, users use partial functions of software. If we could construct software which leave useful functions and remove unuseful functions in software with many functions, we could enhance execution efficiency by reduction of program size and quality of software. There are 6 items in international standard ISO/IEC 9126 about quality of software. These are functionality, reliability, usability, efficiency, maintenance and portability. In this study, we proposed metrics for measurement of efficiency and simplification method for source code. And we described products evaluation result and indicated problem and progress method for practical development project about proposed efficiency metrics.

  • PDF