• Title/Summary/Keyword: IEC code

Search Result 73, Processing Time 0.026 seconds

A Fault Diagnosis Method of Oil-Filled Power Transformers Using IEC Code based Neuro-Fuzzy Model (IEC 코드 기반의 뉴로-퍼지모델을 이용한 유입변압기 고장진단 기법)

  • Seo, Myeong-Seok;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.41-46
    • /
    • 2016
  • It has been proven that the dissolved gas analysis (DGA) is the most effective and convenient method to diagnose the transformers. The DGA is a simple, inexpensive, and non intrusive technique. Among the various diagnosis methods, IEC 60599 has been widely used in transformer in service. But this method cannot offer accurate diagnosis for all the faults. This paper proposes a fault diagnosis method of oil-filled power transformers using IEC code based neuro-fuzzy model. The proposed method proceeds two steps. First, IEC 60599 method is applied to diagnosis. If IEC code can't determine the fault type, neuro-fuzzy model is applied to effectively classify the fault type. To demonstrate the validity of the proposed method, experiment is performed and its results are illustrated.

Design and Implementation of Conversion System Between ISO/IEC 10646 and Multi-Byte Code Set (ISO/IEC 10646과 멀티바이트 코드 세트간의 변환시스템의 설계 및 구현)

  • Kim, Chul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.319-324
    • /
    • 2018
  • In this paper, we designed and implemented a code conversion method between ISO/IEC 10646 and the multi-byte code set. The Universal Multiple-Octet Coded Character Set(UCS) provides codes for more than 65,000 characters, huge increase over ASCII's code capacity of 128 characters. It is applicable to the representation, transmission, interchange, processing, storage, input and presentation of the written form of the language throughout the world. Therefore, it is so important to guide on code conversion methods to their customers during customer systems are migrated to the environment which the UCS code system is used and/or the current code systems, i.e., ASCII PC code and EBCDIC host code, are used with the UCS together. Code conversion utility including the mapping table between the UCS and IBM new host code is shown for the purpose of the explanation of code conversion algorithm and its implementation in the system. The programs are successfully executed in the real system environments and so can be delivered to the customer during its migration stage from the UCS to the current IBM code system and vice versa.

The development of RFID multi-codes converter based on ID profiles (ID 프로파일을 이용한 RFID 멀티 코드 변환기 연구)

  • Lee, Chang-Yeol;Mo, Hee-Sook
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.2
    • /
    • pp.124-133
    • /
    • 2009
  • There are many different ID representation forms depending on the media or applications. In case of RFID tag, ID representation form must be followed by the rule of ISO/IEC 15962. In this study, we developed the efficient ID conversion algorithm between ID representation form on RFID tag and Internet. The main idea is on the use of XML based ID profiles and three step logical IDs forms. The algorithm was tested by the typical three kinds of real IDs such as EPC, ISO/IEC 15459 KKR Code, and mCode which are the typical meta-IDs can be defined in ISO/IEC 18000-6C tag.

Operating Pressure Conditions for Non-Explosion Hazards in Plants Handling Propane Gas

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.493-497
    • /
    • 2020
  • Hazardous area classification is designed to prevent chemical plant explosions in advance. Generally, the duration of the explosive atmosphere is used for zone type classification. Herein, IEC code, a quantitative zone type classification methodology, was used to achieve Zone 2 NE, which indicates a practical non-explosion condition. This study analyzed the operating pressure of a vessel handling propane to achieve Zone 2 NE by applying the IEC code via MATLAB. The resulting zone type and hazardous area grades were compared with the results from other design standards, namely API and EI codes. According to the IEC code, the operating pressure of vessels handling propane should be between 101325-116560.59 Pa. In contrast, the zone type classification criteria used by API and EI codes are abstract. Therefore, since these codes could interpret excessively explosive atmospheres, care is required while using them for hazardous area classification design.

The Trand analysis of the International Standard of the Building Electrical Installations (건축전기설비 관련 규정의 국제화 동향 분석)

  • 이기홍
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.93-95
    • /
    • 2003
  • Owing to WTO/TBT, Many countries are trying to accord their own various national codes and standards with international standards. Also Korean electric power code is being made consistent with the new standards which include the international standards. The new code will affect the many aspects of building construction. In order to cope with the change of the electric power code, this paper analyzed the trend of the international standard(IEC 60364, IEC 61024) and we think this study will help engineers to understand the international electrical standards.

  • PDF

The Effect of the Change of Wind Velocity on the Classification of Explosion Hazardous Area (폭발위험장소 선정 시 풍속 변화에 관한 연구)

  • Kwon, Yong-Joong;Kim, Dong-Joon
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.62-67
    • /
    • 2018
  • It is very important to classify explosion hazardous area in order to prevent an accident explosion. In order to prevent such a explosion, the Industrial Safety and Health Standards Rules stipulates the establishment and management of explosion hazards in accordance with the criteria set by the Korean Industrial Standards. This study has investigated the range of the explosion hazardous area according to various hole sizes, pressures, vapor densities, and wind velocities in the outdoor flammable liquid tank using KS C IEC-60079-10-1 $2^{nd}$ Ed.(=IEC CODE) and PHAST. The results show that the explosion hazardous areas by IEC CODE have circle shapes. However, the areas by PHAST show ellipse shapes. The different of the explosion hazardous areas increases with the increase of wind velocity.

Development of a Software PLC for PC Based on IEC 61131-3 Standard (IEC 61131-3 표준을 따른 PC용 소프트웨어 PLC의 개발)

  • Lee, Cheol-Soo;Jeong, Gu;Lee, Je-Phil;Sim, Ju-Hyun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.1
    • /
    • pp.61-69
    • /
    • 2002
  • This paper describes a converting algorithm between programmable languages of a software PLU. It is based on IEC 61131-3 standard and PC. The proposed control logic is designed by the software model and common element with data type, variables, POUs(program organization unit) and execution control unit commonly used within programmable languages of IEC 61131-3 Standard. The generation method of object file is proposed on five programmable language based on IEC 61131-3. It is represented as fo11ows; 1) the generation method using conversion algorithm from LD to IL with FBD(function block diagram), 2) the generation method using f code generation algorithm from SFC using the SFC execution sequence with FBD and ST(structured text). The proposed control logic generator was implemented by Visual C++ 6.0 and MFC on MS-windows NT 4.0.

Development of an Intelligent Software Programmable Logic Controller for IEC1131-3 International Standard Languages (IEC1131-3 표준언어 처리를 위한 지능적 소프트웨어 PLC 개발)

  • Cho, Young-Im
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.2
    • /
    • pp.207-215
    • /
    • 2004
  • The PLC programming by IEC1131-3 is hard to handle to ordinary users as well as professionals. Also it has not a generality, so that it couldn't be debugging some logic errors easily. In order to be adapted for such environment, In this paper, I have developed the ISPLC(Intelligent Agent System based Software Programmable Logic Controller). In ISPLC system, LD programmed by a user is converted to the C code which can be used in a commercial editor such as Visual C++. The detection of logical errors in C code is more effective than PLC programming itself. ISPLC provides the GUI-based interface in web environment and an easy programming platform to such beginners as well as professionals. The study of code conversion of LD to IL as well as IL to C is firstly tried in the world as well as KOREA. To show the effectiveness of the developed system, I applied it to a practical case, a real time traffic control system. ISPLC is minimized the error debugging and programming time owing to be supported by windows application programs.

KKR code conversion based on ontology (온톨로지 기반 KKR 코드 변환)

  • Kang, Min-Soo;Noh, Young-Sik;Byun, Yung-Cheol;Lee, Dong-Cheol;Jun, Kye-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.484-492
    • /
    • 2011
  • KISA announced KKR code system observing the international standard, ISO/IEC 15459, in order to activate the domestic RFID industry and improve mutual operation among RFID services. In this paper, we propose the way on code conversion based on ontology methods so as to effectively convert various types of RFID KKR code data collected from RFID reader into URN code in the middleware based on the ALE standard spec of EPC global. The results of experiment show that various types of RFID KKR code data could be converted into URN codes successfully. This means that even though new types of KKR code are added, it can be extended easily by adding ontology information without rebuilding the middleware.

A Study on the Unification of the Grounding System of Urban Railroad (도시철도 지하구간 접지설비 표준화 기준 연구)

  • Kim, Gyun-Sig;Park, Han-Yeong;Back, Yu-Ho;Sim, Jae-Chang
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.470-480
    • /
    • 2008
  • After 1th line was built in 1974, the history of subway in Korea has been expended to 9th line which is under construction. It is time to prepare nation wide subway grounding system urgently according to the domestic electric standard that aligns to world wide standard by WTO/TBT treat (1995). Newly added grounding system to the fundamentally different system caused many problems. PSD(platform screen door) and other newly added equipment are also need grounding system. By the electrical code(established by Korea Electric Association), low voltage equipment(including grounding system) under 1,000V AC are in the process of change into IEC 60374. IEC 60364 standard will be added to the electrical code(established by Korea Electric Association) in 2007 and amended and after 3-5 years later, it will become a complete IEC 60364. So the purpose of this study is to compare the domestic rail road grounding system and suggest the standardized grounding system for the newly built subway.

  • PDF