Design and Analysis of an Accelerated Life Test for Magnetic Contactors

  • Ryu, Haeng-Soo;Park, Sang-Yong;Han, Gyu-Hwan;Kwon, Young-Il;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.188-193
    • /
    • 2007
  • Magnetic contactors (MCs) are widely used in industrial equipment such as elevators, cranes and factory control rooms in order to close and open the control circuits. The reliability of MCs mainly depend on mechanical durability and international standards such as IEC 60947-4-1, which stipulates the testing method for MCs. Testing time, however, is so long in usual cases that a method of reducing testing time is required. Therefore, a temperature and voltage-accelerated life testing (ALT) method has been developed to reduce the testing time in this work. The accelerated life test data are analyzed and acceleration factors (AFs) are provided.

Predicted Cooling Performance of Single Finned Heat Dissipating Block for Economic Assessment of LED Module Markings in Standards (LED 모듈 표준 표시사항의 경제적인 평가를 위한 단일 핀 방열 블록의 냉각성능 예측)

  • Huh, Young-Joon;Song, Myung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.81-91
    • /
    • 2015
  • LED has received intensive research attention due to its long life, high efficacy, fast response and wide colour availability, and has secured extensive application areas. However, LED chips within the modules convert only fraction of electric energy into light, and majority of supplied energy needs to be dissipated as heat, which challenges in the performance and life of the LED modules. IEC 62717 specifies the performance requirements for LED modules together with the test methods and conditions. The present study examined the influence of different design parameters on performance temperature through series of experiments and numerical simulations. The economic means to change the module performance temperature during the measurement of mandatory markings were suggested based on predicted cooling performances.

Partial Safety Factor of Offshore Wind Turbine Pile Foundation in West-South Mainland Sea (서남해안 해상풍력단지 말뚝기초의 부분안전계수)

  • Yoon, Gil Lim;Kim, Sun Bin;Kwon, O Soon;Yoo, Moo Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1489-1504
    • /
    • 2014
  • This paper is aimed to suggest a site specific partial safety factor of offshore wind turbine (OWT) pile foundation design for the offshore wind turbine complex at a West-South mainland sea in Korea. International offshore wind design standards such as IEC, GL, DNV, API, ISO and EUROCODE were compared with each partial safety factor and resistance factor. Soil uncertainty analysis using a large number of soil data sampled was carried out, and their results were adapted to estimate partial safety factor of OWT pile foundation through reliability analyses. The representative partial safety factor has been estimated as 1.3. When a proposed partial factor is willing to use to other sites, it is recommended that further studies on code calibration are required to validate their accuracy using more site characterization data.

A Study for Secure the Reliability of Automated Warehouse System (자동화창고 시스템의 신뢰성 확보를 위한 연구)

  • Lee, Yang-Kyu;Yang, Hae-Sool
    • Journal of Digital Convergence
    • /
    • v.14 no.10
    • /
    • pp.253-259
    • /
    • 2016
  • Recently, not only domestic businesses but also overseas businesses are expanding development and investment in automated warehouses as domestic and foreign logistics environments undergo drastic change. In such an environment, automated warehouse systems are being rapidly changed, and automated warehouse systems equipped with diversified functions are being developed accordingly. But the assessment systems of developed automated warehouse system is at a standstill. In the present article, characteristics of the automated warehouse systems in diversified development and trends of technology were analyzed, based on which evaluation items of functional suitability and reliability were derived by referring to ISO/IEC 25000 as the international quality assessment standard to secure reliability of the automated warehouse system, and an evaluation model was developed through the derived evaluation items. Through the present article, evaluation standards of functional suitability and reliability to enhance quality levels of automated warehouse systems are considered to be secured.

An efficient hardware implementation of 64-bit block cipher algorithm HIGHT (64비트 블록암호 알고리듬 HIGHT의 효율적인 하드웨어 구현)

  • Park, Hae-Won;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.9
    • /
    • pp.1993-1999
    • /
    • 2011
  • This paper describes a design of area-efficient/low-power cryptographic processor for HIGHT block cipher algorithm, which was approved as standard of cryptographic algorithm by KATS(Korean Agency for Technology and Standards) and ISO/IEC. The HIGHT algorithm, which is suitable for ubiquitous computing devices such as a sensor in USN or a RFID tag, encrypts a 64-bit data block with a 128-bit cipher key to make a 64-bit cipher text, and vice versa. For area-efficient and low-power implementation, we optimize round transform block and key scheduler to share hardware resources for encryption and decryption. The HIGHT64 core synthesized using a 0.35-${\mu}m$ CMOS cell library consists of 3,226 gates, and the estimated throughput is 150-Mbps with 80-MHz@2.5-V clock.

Image Quality Evaluation of Digital X-Ray Detector Using Amorphous Selenium Layer and Amorphous Silicon TFT Array (비정질 셀레늄층과 비정질 실리콘TFT배열을 사용하는 디지털 X-선 검출기의 영상특성 평가)

  • Kim, Chang-Won;Yoon, Jeong-Key;Kim, Jong-Hyo
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.219-226
    • /
    • 2008
  • In this study, we have conducted characterization of imaging performance for a flat panel digital X-ray detector using amorphous Selenium and a-Si TFT which was developed by the authors. The procedures for characterization were in concordance with internationally recommended standards such as IEC (international electrotechnical commission). The measures used for imaging performance characterization include response characteristic, modulation transfer function (MTF), detective quantum efficiency (DQE), noise power spectrum (NPS), and quantum limited performance. The measured DQEs at lowest and highest spatial frequencies were 40% and 25% respectively, which was superior to that of commercial products by overseas vendor. The MTF values were significantly superior to that of CR and indirect type DRs. The quantum limited performance showed the detector was limited by quantum noise at the entrance exposure level below 0.023 mR, which is sufficiently low for general X-ray examination.

  • PDF

A Study on the Improvement of Reliability of Safety Instrumented Function of Hydrodesulfurization Reactor Heater (수소화 탈황 반응기 히터의 안전계장기능 신뢰도 향상에 관한 연구)

  • Kwak, Heung Sik;Park, Dal Jae
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.7-15
    • /
    • 2017
  • International standards such as IEC-61508 and IEC-61511 require Safety Integrity Levels (SILs) for Safety Instrumented Functions (SIFs) in process industries. SIL verification is one of the methods for process safety description. Results of the SIL verification in some cases indicated that several Safety Instrumented Functions (SIFs) do not satisfy the required SIL. This results in some problems in terms of cost and risks to the industries. This study has been performed to improve the reliability of a safety instrumented function (SIF) installed in hydrodesulfurization reactor heater using Partial Stroke Testing (PST). Emergency shutdown system was chosen as an SIF in this study. SIL verification has been performed for cases chosen through the layer of protection analysis method. The probability of failure on demands (PFDs) for SIFs in fault tree analysis was $4.82{\times}10^{-3}$. As a result, the SIFs were unsuitable for the needed RRF, although they were capable of satisfying their target SIL 2. So, different PST intervals from 1 to 4 years were applied to the SIFs. It was found that the PFD of SIFs was $2.13{\times}10^{-3}$ and the RRF was 469 at the PST interval of one year, and this satisfies the RRF requirements in this case. It was also found that shorter interval of PST caused higher reliability of the SIF.

An implementation of block cipher algorithm HIGHT for mobile applications (모바일용 블록암호 알고리듬 HIGHT의 하드웨어 구현)

  • Park, Hae-Won;Shin, Kyung-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.125-128
    • /
    • 2011
  • This paper describes an efficient hardware implementation of HIGHT block cipher algorithm, which was approved as standard of cryptographic algorithm by KATS(Korean Agency for Technology and Standards) and ISO/IEC. The HIGHT algorithm, which is suitable for ubiquitous computing devices such as a sensor in USN or a RFID tag, encrypts a 64-bit data block with a 128-bit cipher key to make a 64-bit cipher text, and vice versa. For area-efficient and low-power implementation, we optimize round transform block and key scheduler to share hardware resources for encryption and decryption. The HIGHT64 core synthesized using a $0.35-{\mu}m$ CMOS cell library consists of 3,226 gates, and the estimated throughput is 150-Mbps with 80-MHz@2.5-V clock.

  • PDF

BCI Probe Emulator Using a Microstrip Coupler (마이크로스트립 커플러 구조를 이용한 BCI 프로브 Emulator)

  • Jung, Wonjoo;Kim, SoYoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1164-1171
    • /
    • 2014
  • Bulk Current Injection(BCI) test is a method of injecting current into Integrated Circuit(IC) using a current injection probe to qualify the standards of Electromagnetic Compatibility(EMC). This paper, we propose a microstrip coupler structure that can replace the BCI current injection probe that is used to inject a RF noise in standard IEC 62132-part 3 documented by International Electrotechnical Commission. Conventional high cost BCI probe has mostly been used in testing automotive ICs that use high supply voltage. We propose a compact microstrip coupler which is suitable for immunity testing of low power ICs. We tested its validity to replace the BCI injection probe from 100 MHz to 1,000 MHz. We compared the power[dBm] that is needed to generate the same level of noise between current injection probe and microstrip coupler by sweeping the frequency. Results show that microstrip coupler can inject the same level of noise into ICs for immunity test with less power.

A Study on Classification of Explosion Hazardous Area for Facilities using Lighter-than-Air Gases (공기보다 가벼운 가스 사용시설의 폭발위험장소 설정방안에 대한 연구)

  • Yim, Ji-Pyo;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • There have been controversies over whether explosion hazardous area(EHA) should be classified for facilities which use lighter-than-air gases such as city gas, hydrogen and ammonia. Two view points are confronting each other: an economic piont of view that these gases are lighter than air and disperse rapidly, hence do not form EHA upon release into the atmosphere, and a safety point of view that they are also inflammable gases, hence can form EHA although the extent is limited compared to heavy gases. But various standards such as KS, IEC, API, NFPA do not exclude light gases when classifying EHA and present examples of EHA for light gas facilities. This study calculates EHA using the hypothetical volume in the IEC code where the hole sizes required for the calculation were selected according to various nominal pipe sizes in such a way to conform to the EHA data in the API code and HSL. Then, 25 leakage scenarios were suggested for 5 different pipe sizes and 5 operating pressures that cover typical operating conditions of light gas facilities. The EHA for the minimum leakage scenario(25 mm pipe, 0.01MPa pressure) was found to correspond to a hypothetical volume larger than 0.1 $m^3$(medium-level ventilation). This confirms the validity of classifying EHA for facilities using lighter-than-air gases. Finally, a computer program called HACPL was developed for easy use by light gas facilities that classifies EHA according to operating pressures and pipe sizes.