• Title/Summary/Keyword: IEC Standards

Search Result 515, Processing Time 0.025 seconds

A Study on the Electrical and Thermal Safety of System LED Lighting (시스템 LED 조명의 전기적·열적 안전성 확보 방안에 대한 연구)

  • Kim, Yeong Woo;Kim, Chung Hyeok;Choi, Woon Shik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.418-426
    • /
    • 2020
  • This study tested the electrical, structural, and thermal safety of LED lighting products, available on the market. Five recessed LED systems, 20 W each, and five fixed LED systems, 25 W each, were selected. Dielectric strength tests, live part electric shock protection tests, and thermal tests were conducted on the LEDs. These were key tests for user safety, according to the specification of the safety criteria for electric products, KC 60598-1, South Korea. In addition, the wiring temperature of UL1007, 60227 IEC 08, and UTP cables, was measured. The results of the study gave an in-depth examination of the safety of LED lighting systems for users.

A Study on the Harmonic Analysis of an Electronic Ballast (전자식 안정기의 고조파 저감 대책)

  • Choi, Hong-Kyu;Hong, Sun-Suk;Oh, Jung-Suk;Yoo, Tae-Kun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.121-127
    • /
    • 2004
  • Electric ballast is widely used to turn on the fluorescent. Electric ballast measure occurrence of harmonic through the actual measurement and it is simulated by modeling equivalent circuit for harmonic analysis. The purpose of this paper is to give an equivalent circuit modeling methodology for the harmonic currents generated by single-phase personal computer loads to evaluate a commercially available series resonant filter for the harmonic currents compensation based on the IEC std 61000-3-2 and IEEE 519 standards for limiting harmonic distortion.

  • PDF

The Construction of Safety Measurement Equipment of Grounding Electrode for Distribution System (배전용 접지전극의 안전성 분석 장치 구성)

  • Kang, Moon-Ho;Park, Young-Keun;Jang, Sang-Ok;Won, Yoon-Chan;Lee, Heung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.218-221
    • /
    • 2005
  • Grounding electrodes as discharge paths to the earth are normally used to ensure the safety of human body and facilities from the over-voltages in distribution power system, and each grounding mode has a prescribed ground resistance value respectively which is applied by the utilities. As the various electrodes for distribution power system are recently developing to improve the performance of them and resolve the problem of space restriction, it is necessary to measure and investigate the safety of human body of developed electrodes. Therefore, in this paper, we provide briefly a technical comparison of two standards, i.e. IEEE Std 80 and the IEC 479-1, and describe the configuration of safety measurement system which can measure the step voltage and the touch voltage of grounding electrodes based on IEEE Std 80.

  • PDF

Analysis on Installation Condition According to Dynamic Characteristics for Overhead Catenary System (전차선로 동적특성에 따른 설치상태 분석)

  • Park, Young;Lee, Kiwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1605-1609
    • /
    • 2016
  • The measurement of current collection performance between pantograph and contact wire of overhead catenary system is intended to prove the safety of operation and the quality of the current collection system. The results of interaction performance of current collection system are required for approving with commercial operation on railway lines. The methods of interaction performance of current collection system are defined on interactional standards such as IEC 62486 and EN 50317. In this paper, the interaction performance is evaluated by the percentage of arcing on Honam high-speed line and the results are used for adjustment of the overhead catenary line structure. The experimental results in Honam high-speed line confirm that the duration of an arc lasting longer 25 ms between pantograph and contact wire was depended on the conditions of overhead contact line after installation.

Investigations on Eco Friendly Insulating Fluids from Rapeseed and Pongamia Pinnata Oils for Power Transformer Applications

  • Thanigaiselvan, R.;Raja, T. Sree Renga;Karthik, R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2348-2355
    • /
    • 2015
  • Transformer mineral oil which is normally hydrocarbon based is non- biodegradable and pollutes the environment in all aspects. Though vegetable oils are eco-friendly in nature and potentially could be used in transformers as a replacement for the mineral oil, there usage is restricted because of their oxidative instability. The present work focuses on using rapeseed oil and pongamia (pongamia pinnata) oil as effective alternatives for the traditional mineral oil in power transformer. The oxidative stability of the rapeseed oil and pongamia oil is increased by using combinations of the natural and synthetic anti-oxidants as additives. The parameters like breakdown voltage, viscosity, flash point, fire point are measured for the rapeseed oil and pongamia oil with and without the additives as per IEC and ASTM standards. The results shown encouraging changes in the parameter values and ensures the use of the oils as a potential alternative insulation in power transformers.

A Consideration of Volume and Installation Method of Concrete-Embedded Foundation Earthed an Electrode (콘크리트에 매입된 기초접지극의 크기 및 설치방법에 관한 고찰)

  • Lee, Ju-Cheol;Lee, Young-Chul;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.82-88
    • /
    • 2013
  • IEC standards do not require to limit the earthing resistance of the concrete-embedded foundation earthing electrode which is installed to a specific value. However, in Korea the value of $5{\Omega}$ and below applies to the earthing resistance for a domestic customer whose receiving voltage is 22.9kV. This paper calculates the minimum area and volume of the concrete-embedded foundation earthing electrode in order to obtain a specific value of the earthing resistance when the electrode of the building's lightning protection system and that of its power system are interconnected. It also suggested the most appropriate method of installing the foundation earthing electrode, taking the electric characteristics of concrete into account.

A Study on the RAMS Activities and Practices for assuring Safety of the Centralized Traffic Control System of Urban Railway (도시철도관제시스템 안전성 확보를 위한 RAMS 활동 및 그 적용사례에 관한 연구)

  • Choi, Yo Chul
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.10 no.2
    • /
    • pp.43-50
    • /
    • 2014
  • The Centralized Traffic Control(CTC) System of Urban Railway is an element(subsystem) of the Urban Railway system to aim safety operation and efficient management of rolling stock in accordance with a train scheduling program in train operation ways. That's why the CTC System must be developed considering systematic and safety-guaranteed methods such as RAMS(Reliability, Availability, Maintainability, and Safety) refereed to IEC standards. The CTC System is consists of rolling stock, signaling, power supply, communication, and mechanical equipment and preforms control and remote monitoring functions. The technical activities considering safety process are very important at such an early stage of development in a railway project. This paper introduces RAMS activities and an independent safety assessment by $3^{rd}$ Party focused on a safety applied to a development of the CTC system of Urban Railway and proposes the experiences as well practices.

A Design of Power Management and Control Systems Using Digital Protective Relays (디지털보호계전기를 활용한 전력감시제어시스템 설계)

  • Lee, Sung-Hwan;Ahn, Ihn-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.191-193
    • /
    • 2000
  • In this paper, being different from traditional methods, we design digital protective relay which can be applied to power management and control systems of not only small and medium but also a large scale plants. The digital protective relay was designed with DSP CPU(TMS320C31) to protect and measure more quickly and precisely. We will present test result which it performed according to the standards of Korea Electrical Manufactures Cooperative to prove the faculties of digital protective relay. The test result on the basis of KEMC1120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within ${\pm}5%$.

  • PDF

Comparison and Analysis of Library RFID Data Model for Major National Standards (주요 국가별 표준 도서관 RFID 데이터 모델의 비교 및 분석)

  • Choi, Jae-Hwang
    • Journal of Korean Library and Information Science Society
    • /
    • v.40 no.2
    • /
    • pp.87-110
    • /
    • 2009
  • This study examined and compared existing national library RFID data models, especially for Denmark, Finland, Netherlands, France, the U.S., Australia and South Korea. Four European country models(i.e., Danish, Finnish, Dutch, and French models) and South Korea use prescriptive data model(fixed encoding approach), while The U.S. and Australia adopt object-based data model, which is based on the data encoding rules of ISO/IEC 15962. This study expects to allow fertile ground for discussion on RFID data models in South Korean library environment.

  • PDF

A Study on IT Service Management Based on ITIL with Consideration of IT Governance Structures : Focused on A Case Study of Manufacturing Company (IT 거버넌스 체계를 고려한 ITIL 기반의 IT 서비스 관리에 관한 연구 : 제조업 사례 중심으로)

  • Oh, Hwa-Seog;Cho, Chi-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.149-159
    • /
    • 2010
  • Unknowingly, the relationship between IT departments and their internal customers becomes that of client-supplier based on the mechanisms of marketing and competition. In addition, due to enhanced focus on the customer in the planning, development, and delivery of information service, IT service management(ITSM) has become increasingly important. These days IT management is focusing particularly on the 'de-facto' standard ITIL (IT Infrastructure Library) for implementing ITSM. It is linked as a part of CobiT’s 'deliver and support' domain, which is a framework of IT governance, and ISO/IEC 20000 is a unique international certification standards on the ITSM. This paper proposes the strategy and procedure for ITSM implementation based on ITIL with consideration of IT governance structure for manufacturing industries. It also presents a case study to share the lessons learned and results of an ITSM project.