• Title/Summary/Keyword: IEC Standards

Search Result 516, Processing Time 0.023 seconds

Lightning Risk Assessment for Structures Lower than 20m High (높이 20미터 미만인 구조물의 낙뢰리스크 평가)

  • Lee, Ju-Chul;Kim, Gi-Hyun;Lee, Young-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.21-27
    • /
    • 2012
  • Korean Industrial Standards for lightning protection system complies with IEC standards. However, the standards are applicable only to buildings and structures more than 20 meters in high. Therefore, it is necessary to determine whether lightning protection system should be installed on structures lower than 20 meters high. This paper proposes an efficient method of assessing risk against lightning of structures lower than 20 meters high. The method suggests simplified lightning protection system and provides selecting an appropriate protection level. The suggested method assumes that structure under assessment has no lightning protection system and there is no person around the structure at the moment of lightning stroke. A simplified method of assessing the risk to human within the structure is developed by adopting the general assessment factor. The selection of a protection level is possible by comparing tolerable risk with physical damage risk caused by a direct lightning. Finally, this paper gives ways to establish surge protection measures when a structure with lightning risk is within a radius of 2km from the assessed structure even if this structure requires no lightning protection system.

The Acoustic Output Estimation for Therapeutic Ultrasound Equipment using Electro-Acoustic Radiation Conductance (전기-음향 방사컨덕턴스를 이용한 치료용 초음파 자극기의 음향출력 예측)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.264-269
    • /
    • 2011
  • To increase therapeutic efficiency and biological safety, it is important to precision control of acoustic output for therapeutic ultrasound equipment. In this paper, the electro-acoustic radiation conductance, one of electroacoustic characteristics of therapeutic ultrasound equipment, was measured by the radiation force balance method according to IEC 61161 standards and the acoustic output was estimated using the electro-acoustic radiation conductance. The estimation of acoustic output was conducted to continuous wave mode and pulse wave mode of duty cycle between 20% and 80%. The differences between prediction values and measurement results are within 5% of measurement uncertainty, which is a reasonably good agreement. The results show that acoustic output controlled by electro-acoustic radiation conductance was found to be an effective method.

Research on Standards for Protection against Electric Shock in Global Technical Regulations of Fuel Cell Vehicle (연료전지 자동차 세계기술규정의 감전보호기준 연구)

  • HwangBo, Cheon;Lee, Kyu-Myong;You, Kyeong-Jun
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.3
    • /
    • pp.167-183
    • /
    • 2010
  • This paper analyzes the backgrounds of the standards for protection against electric shock in Global Technical Regulations (GTR) of Fuel Cell Vehicle (FCV). Targets on research were high voltage criteria, safety current, isolation and grounding resistance, time limitation, energy, adequate clearance, and test procedure. Based on human impedance and effect of current in IEC 60479-1, safety of human was examined. Then, isolation and grounding circuit model of FCV were analyzed theoretically. The results give several suggestions: touch voltage less than 25V, AC energy less than 0.0813J, separation considering middle finger length, grounding resistance less than $0.2\Omega$, maximum AC ground voltage of 1V (rms), and isolation resistance between earth and electrical chassis. In MATLAB/Simulink environment, error characteristics of isolation resistance measurement procedure using internal DC sources were analyzed under variations of internal resistance of voltmeter and isolation resistance.

A Study on Safe Permanent Joint Type Multiple Socket-Outlets Development without Soldering Crimped Connection (안전형 비납땜 틀고정 영구 접속형 멀티콘센트 개발에 관한 연구)

  • Cho, Won-Seok;Lee, Wi-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.47-54
    • /
    • 2015
  • Normally, multiple socket-outlet is manufactured with soldered, welded permanent connection (termination). Because this procedure is very non-environmental and requires many labor forces, many companies skip this process. To solve this these problems, this research had to design permanent joint type multiple socket-outlet, develop safer multiple socket-outlet than is sold in markets. Progressing this research, we took 3 steps. First, we had to design device for fixing a frame suitable for multiple socket-outlet. Second, this multiple socket-outlet must pass fundamental standards through international standard (IEC 60884-1) and Korean standard (K 60884-1) tests. Third, it had to pass both several mechanical and electrical tests which is more strict than fundamental standards and vibration and impact tests following KS standards for enhancing its safety. After finishing 3 steps, we could obtain objective and fair data, develop environmental permanent joint type multiple socket-outlet without soldering crimped connection.

A New Instrument for Measuring the Optical Properties of Wide-field-of-view Virtual-reality Devices

  • Ahn, Hee Kyung;Lim, Hyun Kyoon;Kang, Pilseong
    • Current Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.392-399
    • /
    • 2022
  • Light-measuring devices (LMDs) are frequently used to measure luminance and color coordinates of displays. However, it is very difficult to use a conventional LMD for measuring the optical properties of virtual-reality (VR) devices with a wide field of view (FOV), because of their confined spaces where the entrance pupil of a LMD is located. In this paper, a new LMD that can measure the optical properties of wide-FOV VR devices, without physical conflict with the goggles of the VR device, is proposed. The LMD is designed to fully satisfy the requirements of IEC 63145-20-10, and a pivot-point correction method for the LMD is applied to improve its accuracy. To show the feasibility of the developed LMD and the correction method, seven VR devices with wide FOV are measured with it. From the results, all of them are successfully measured without any physical conflict, and a comparison to their nominal values shows that the FOVs have been properly measured.

A Dynamic Rating System for Power Cables (I) - Real Time CTM(Conductor Temperature Monitoring) (전력 케이블 실시간 허용전류산정 시스템에 관한 연구 (I) - 실시간 도체 온도 추정 시스템)

  • 남석현;이수길;홍진영;김정년;정성환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.7
    • /
    • pp.414-420
    • /
    • 2003
  • The domestic needs for larger capability of power sources are increasing to cope with the expanding power load which results from the industrial developments & the progressed life style. In summer, the peak load is mainly due to the non-industrial reasons such as air-conditioners and other cooling equipments. To cover the concentrated peak load in stable, the power transmission lines should be more constructed and efficiently operated. The ampacity design of the underground cable system is generally following international standards such as IEC287, IEC60853 and JCS168 which regards the shape of 100% daily full power loads. It is not so efficient to neglect the real shapes of load curves generally below 60~70% of full load. The dynamic (real time) rating system tends to be used with the measured thermal parameters which make it possible to calculate the maximum ampacity within required periods. In this paper, the CTM(Conductor Temperature Monitoring) which is the base of dynamic rating systems for tunnel environment is proposed by a design of lumped thermal network ($\pi$-type thermal model) and distribution temperature sensor attached configuration, including the estimation results of its performances by load cycle test on 345kV single phase XLPE cable.

Questionnaire Development and Survey & Analysis for the Calculation of the Domestic Industrial Customer Interruption Costs (산업수용가의 정전비용 산출을 위한 조사 분석 연구)

  • 박충열;남기영;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.165-170
    • /
    • 2004
  • This paper presents summary results of direct interview survey of Korean industrial customers conducted to evaluate the direct and short duration interruption costs resulting from local random electrical supply interruptions. The cost is evaluated using the questionnaires authors designed, which are mainly on the experience or preparatory actions consumers predicted they would take. Economic evaluation of reliability that traditionally takes into account duration and frequency of interruption does not accurately reflect the lost value or economic impacts of industrial customer, especially large size, caused by any kind of interruption. So, to imply the substantial difference in costs incurred by different customer group, the authors apply the international standards, i.e. IEC, IEEE, to the analysis on the interruption costs.

The Development of Neuromuscular Electrical Stimulation Medical Devices for The Treatment of Non-implantable Urinary Incontinence (비이식형 요실금 치료용 신경근 전기자극 의료기기 개발)

  • Lee, Jae-Yong;Lee, Chang-Doo;Kwon, Ki-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, the neuromuscular electrical stimulation medical devices for non-implantable incontinence treatment other than vaginal insertion type was developed and commercialized. The structure of medical devices for electrical stimulation based on the anatomy of the pelvic floor muscle designed. Then, the optimum parameters that may be effective in pelvic floor muscle electrical stimulation was set. The circuit system based on the optimum parameters were designed and manufactured. The frequency of the pulse voltage for electrical stimulation is 75[Hz], the pulse width is 300[${\mu}s$], the development of medical devices was to have seven program functions to the various treatments. The circuit system of medical devices was composed of microcontroller, comparator and converter. The performance of the developed circuit system in KTC(Korea Testing Certification) were carried out medical equipment inspection test. Test results, test specifications were satisfied with the medical device, the performance was verified to be commercialized as a medical device. The development of medical devices were validated risk assessment and product performance through a software validation. Commercialization of medical equipment was acquired to enable the certification standards of the international standard IEC 60601-1.

Non-equal DC link Voltages in a Cascaded H-Bridge with a Selective Harmonic Mitigation-PWM Technique Based on the Fundamental Switching Frequency

  • Moeini, Amirhossein;Iman-Eini, Hossein;Najjar, Mohammad
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.106-114
    • /
    • 2017
  • In this paper, the Selective Harmonic Mitigation-PWM (SHM-PWM) method is used in single-phase and three-phase Cascaded H-Bridge (CHB) inverters in order to fulfill different power quality standards such as EN 50160, CIGRE WG 36-05, IEC 61000-3-6 and IEC 61000-2-12. Non-equal DC link voltages are used to increase the degrees of freedom for the proposed SHM-PWM technique. In addition, it will be shown that the obtained solutions become continuous and without sudden changes. As a result, the look-up tables can be significantly reduced. The proposed three-phase modulation method can mitigate up to the 50th harmonic from the output voltage, while each switch has just one switching in a fundamental period. In other words, the switching frequency of the power switches are limited to 50 Hz, which is the lowest switching frequency that can be achieved in the multilevel converters, when the optimal selective harmonic mitigation method is employed. In single-phase mode, the proposed method can successfully mitigate harmonics up to the 50th, where the switching frequency is 150 Hz. Finally, the validity of the proposed method is verified by simulations and experiments on a 9-level CHB inverter.

The development standard research for railway safety software (철도 안전 소프트웨어를 위한 개발 기준 연구)

  • Lee, Young-Jun;Kim, Jang-Yoel;Cha, Kyung-Ho;Cheon, Se-Woo;Lee, Jang-Soo;Kwon, Ki-Choon;Jung, Ui-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.968-973
    • /
    • 2007
  • The systems such as the railway control system, satellite control system and nuclear power plant control system are the safety critical systems because the failure of them could lead to risk significant events. These softwares of digital systems must follow the life cycle process from the beginning of software development to guarantee their safety and reliability. The NRC(Nuclear Regulatory Commission) Reg Guide of nuclear fields, the RTCA/DO-178B standard which is used to acquire the certification for software in industrial aero field in European Union and United State, the DEF STAN 00-55 standard for the safety of electronic weapon in England, the IEC 601-1-4 for medical equipment and the IEC 62279 for railway system recommended the development life cycle. This paper introduces the development process and compares each other. Also it indicates applicable development criteria for the software of systems related to railway fields and describes the detailed procedure of development criteria. We describe the procedure to make the software development criteria in nuclear filed. For the software development related to railways, the process from plan phase to maintenance phase must be satisfied. The safety and reliability is guaranteed through these standards.

  • PDF