• Title/Summary/Keyword: IEC 1000

Search Result 37, Processing Time 0.02 seconds

Synthesis and Properties of High Voltage Silicone Rubber by Platinum-based Flame Retardant

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.283-292
    • /
    • 2006
  • So that high-strength and electrical properties apply by excellent high voltage insulator electricity material, ATH content and platinum-based flame retardant that influence in flame retardant and tracking characteristic among composite of silicone rubber studied mechanical strength and influence getting to electrical properties. Composition of ${\alpha}$, ${\omega}-vinyl$ poly (dimethyl-methylphenyl) siloxane(VPMPS) of a polymer quantity made doing mole of D4, $D3^{Me,Ph}$ and VMS by 1000:15:0.2 mole ratio and uses basic catalyst tetramethylammonium silanolate(TMAS) and do opening equilibrium polymerization to be used to main polymer for high voltage insulation insulator. Control ATH content and content of platinum-based flame retardant and made high voltage insulation silicone rubber. Measured mechanical strength of making silicone rubber using UTM, and tracking characteristic according to standard of IEC 60587, flame retardant test studied effect that flame retardant characteristic gets in tracking characteristic, measuring according to UL94V method of test.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

Preparation and Characterization of Anion Exchange Membrane Based on Crosslinked Poly(2,6-dimethyl-1,4-phenylene oxide) with Spacer-type Conducting Group (Spacer-type 전도기가 도입된 가교형 poly(2,6-dimethyl-1,4-phenylene oxide) 음이온 교환막의 제조 및 특성평가)

  • Lim, Haeryang;Kim, Tae-Hyun
    • Membrane Journal
    • /
    • v.27 no.5
    • /
    • pp.425-433
    • /
    • 2017
  • As the problems related to the environmental pollution such as carbon dioxide emission are emerging, the need for the renewable energy and environmentally friendly energy is getting intense. Fuel cells are eco-friendly energy generation devices that generate electrical energy and produce water as a sole by-product. Compared to the traditional proton exchange membrane fuel cell (PEMFC), anion exchange membrane alkaline fuel cell (AEMAFC) has a main advantage of possibility to use low cost metal catalysts due to its faster kinetics. The AEM, which conducts $OH^-$ ions, should possess high ion conductivity as well as high chemical stability at high pH conditions. We hereby introduce a crosslinked poly(2,6-dimethyl-1,4-phenylene oxide) having a spacer-type conducting group as novel AEM, and report a high ion conductivity ($67.9mScm^{-1}$ at $80^{\circ}C$) and mechanical properties (Young's modulus : 0.53 GPa) as well as chemical stability (6.8% IEC loss at $80^{\circ}C$ for 1,000 h,) for the developed membrane.

Construction and Performance Evaluation of Digital Radiographic System (이동형 디지털 X선 촬영장치의 구축 및 성능평가)

  • Cho, Hyo-Min;Nam, So-Ra;Lee, Chang-Lae;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

  • PDF

전기용품안전관리법의 전자파 관련 기술기준개정

  • 박상서
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.4
    • /
    • pp.1-69
    • /
    • 1997
  • 국립기술품질원은 최근 전기용품안전관리법에 의한 전기용품기술기준의 내용 중 전자파장해와 관련된 시험기준 및 측정방법을 대폭 개정하였다. 이 개정은 국립기술품질원 고시 제 1997-140호(1997. 7. 9.)에 의해 이루어졌는데 개정내용의 주요골자는 기존 전자파장해 분야의 기준 및 측정방법을 전면적으로 수정, 보완하고 전자파내성분야의 기준 및 측정방법을 신규로 추가 삽입한 것으로 판단된다. 주지하다시피 전자파장해와 관련해서 우리나라의 국가규격은 전파법에 의한 기술규격과 전기용품 안전관리법에 의한 기술규격으로 양분화되어 있다. 전파법에 의한 기술규격은 작년에 정보통신부 고시 제1996-78, -79, -80, -81호(1996. 10. 9.)에 의해 종전의 전자파장해검정규칙에 따른 시험방법을 CISPR에 의한 모든 대상기기에 대해 전자파장해 및 전자파내성 관련 기술기준 및 시험방법을 대폭 개정한바 있으며, 본 전기용품안전관리법에 의한 기술기준 개정은 전자파장해 및 내성에 관련 내용을 최근의 국제기술동향에 부응하도록 망라하여 정리한 것이라는 관점에서는 전파법에 의한 개정내용과 유사한 것으로 여겨지나, 다만 그 대상기기가 전기 용품으로 한정된 것이 다른 것으로 사료된다. 종전의 전기용품안전관리법에 의한 전자파장해 기술규격은 국제규격인 CISPR의 권고사항을 따르되, 국내 산업계의 의견을 반영하여 측정주파수 범위, 기술기준, 측정방법 등의 내용에 있어서 다소의 수정을 가하였으며, 정보기술기기에 대해서는 미국의 FCC기술기준을 위주로 하여 제정된 것이었다. 금번 기술기준 개정은 전자파장해 분야에 있어서 이와 같은 종전의 기술기준을 최초의 CISPR 기술동향을 최대한 여과없이 반영시키도록 수정하였으며, 전자파내성 분야에 대해서는 전체적으로 IEC 1000-4-Series의 내용을 기본으로 하였으나, 여기에 추가적으로 디지털 무선전화기에 대한 방사내성 시험항목을 ENV55024의 내용을 위주로 하여 신규로 작성한 것으로 볼 수 있다. 따라서 기술기준의 개정사항은 주로 전자파장해 분야로 국한되어 있으며, 전자파내성 분야는 신규 제정한 것으로서 본고에서는 종전의 기술기준에서 전자파장해분야의 변경사항과 신규로 제정된 전자파내성 측정방법과 시험기준을 소개하는 거승로 하겠다.

  • PDF

Mitigation of Potential-Induced Degradation (PID) for PERC Solar Cells Using SiO2 Structure of ARC Layer (반사방지막(ARC)의 SiO2 구조에 따른 PERC 태양전지 PID 열화 완화 상관관계 연구)

  • Oh, Kyoung Suk;Park, Ji Won;Chan, Sung Il
    • Current Photovoltaic Research
    • /
    • v.8 no.4
    • /
    • pp.114-119
    • /
    • 2020
  • In this study, Mitigation of Potential-induced degradation (PID) for PERC solar cells using SiO2 Structure of ARC layer. The conventional PID test was conducted with a cell-level test based on the IEC-62804 test standard, but a copper PID test device was manufactured to increase the PID detection rate. The accelerated aging test was conducted by maintaining 96 hours with a potential difference of 1000 V at a temperature of 60℃. As a result, the PERC solar cell of SiO2-Free ARC structure decreased 22.11% compared to the initial efficiency, and the PERC solar cell of the Upper-SiO2 ARC structure decreased 30.78% of the initial efficiency and the PID reliability was not good. However, the PERC solar cell with the lower-SiO2 ARC structure reduced only 2.44%, effectively mitigating the degradation of PID. Na+ ions in the cover glass generate PID on the surface of the PERC solar cell. In order to prevent PID, the structure of SiNx and SiO2 thin films of the ARC layer is important. SiO2 thin film must be deposited on bottom of ARC layer and the surface of the PERC solar cell N-type emitter to prevent surface recombination and stacking fault defects of the PERC solar cell and mitigated PID degradation.

Radionuclide identification method for NaI low-count gamma-ray spectra using artificial neural network

  • Qi, Sheng;Wang, Shanqiang;Chen, Ye;Zhang, Kun;Ai, Xianyun;Li, Jinglun;Fan, Haijun;Zhao, Hui
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.269-274
    • /
    • 2022
  • An artificial neural network (ANN) that identifies radionuclides from low-count gamma spectra of a NaI scintillator is proposed. The ANN was trained and tested using simulated spectra. 14 target nuclides were considered corresponding to the requisite radionuclide library of a radionuclide identification device mentioned in IEC 62327-2017. The network shows an average identification accuracy of 98.63% on the validation dataset, with the gross counts in each spectrum Nc = 100~10000 and the signal to noise ratio SNR = 0.05-1. Most of the false predictions come from nuclides with low branching ratio and/or similar decay energies. If the Nc>1000 and SNR>0.3, which is defined as the minimum identifiable condition, the averaged identification accuracy is 99.87%. Even when the source and the detector are covered with lead bricks and the response function of the detector thus varies, the ANN which was trained using non-shielding spectra still shows high accuracy as long as the minimum identifiable condition is satisfied. Among all the considered nuclides, only the identification accuracy of 235U is seriously affected by the shielding. Identification of other nuclides shows high accuracy even the shielding condition is changed, which indicates that the ANN has good generalization performance.