• 제목/요약/키워드: ID4

Search Result 764, Processing Time 0.032 seconds

Imaging of Tumor Cell Proliferation using Radiofluorinated Ethyluracil and Deoxyadenosine (Radiofluorinated Ethyluracil과 Deoxyadenosine을 이용한 종양세포 증식의 영상화에 대한 연구)

  • Kim, Chang-Guhn;Yang, David J.;Kim, E. Edmund
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.532-540
    • /
    • 1996
  • 목적 : 종양세포의 증식을 평가하기 위해 radiofluorinated ethyluracil (FEU)과 deoxyadenosine analogue(FAD)를 합성하여 종양의 영상화를 시도하였다. 대상 및 방법 : 5-(2-Fluoroethyl)uracil ([$^{18}F$]FEU)은 2, 4-dimethoxy-5-(2-hydroxyethyl) pyrimidine을 $K^{18}F$와 처리한 후 HBr로 가수분해하여 얻었으며 Fluorodeoxyadenosine은 adenosine의 triacetylated analogue를 $K^{18}F$와 처리하여 얻었다. 생물학적 조직분포는 유방암 세포(13762 NF, 100,000 cells per rat, im)를 쥐에 접종한 후 0.5, 1, 2 및 4시간에 주요장기를 적출하여 %ID/g을 측정하고 자가방사영상은 방사성의약품 투여 45분 후에 얻었다. PET 영상은 VX-2 종양을 접종한 가토를 이용하여 얻었다. In vitro cell proliferation assay는 사람의 말초단핵구를 이용하였다. 결 과 : In vitro assay상 ([$^{18}F$]FEU는 세포증식시 DNA/RNA에 결합함을 시사하였다. ([$^{18}F$]FAD와 ([$^{18}F$]FEU의 종양/비종양 방사능 섭취비는 시간경과에 따라 증가하였으며 ([$^{18}F$]FAD와 ([$^{18}F$]FEU를 이용한 자가방사영상과 ([$^{18}F$]FEU를 이용한 PET 영상에서 종양을 잘 관찰할 수 있었다. 결 론 : ([$^{18}F$]FAD 및 ([$^{18}F$]FEU를 이용하여 종양세포의 증식을 PET 영상에서 평가할 수 있으리라 사료된다.

  • PDF

Performance Characteristics of Air Driven Ejector According to the Position Changes and the Shape of Driving Nozzle (공기구동 이젝터의 노즐 형상과 위치 변화에 따른 성능 특성)

  • Ji, Myoung-Kuk;Kim, Pil-Hwan;Park, Ki-Tae;Utomo, Tony;Chung, Han-Shik;Jeong, Hyo-Min
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.550-556
    • /
    • 2008
  • The aim of this research is to analyze the influence of motive pressure, driving nozzle position and nozzle throat ratio on the performance of ejector. The experiment was conducted in the variation of motive pressure of 0.196, 0.294, 0.392 and 0.490MPa respectively. The position of driving nozzle was varied in difference locations according to mixing tube diameter(0.5d, 1d, 2d, 3d, 4.15d, 5d and 6d). The experimental results show when the nozzle outlet is located at 3d, the flow characteristics change abruptly. It is shown that the suction flow rate and pressure lift ratio of ejector is influenced by the driving nozzle position. At nozzle position location of the Id of mixing tube diameter the performance of ejector gives the best performance.

Iron Deficiency and Early, Low-dose Iron Supplementation in Breast-fed Infants (모유 수유아의 철 결핍과 조기 저용량 철분보충요법의 효과에 대한 연구)

  • Noh, So-Jung;Na, Bo-Mi;Kim, Mi-Jung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.2
    • /
    • pp.169-178
    • /
    • 2008
  • Purpose: The purpose of this study was to determine the efficacy of early low-dose iron supplementation in term breast-fed infants. Methods: Eighty-seven healthy term infants were divided into 3 groups: A, formula-fed; B, breast-fed only; S, breast-fed with iron supplementation (5 mg/day from 2 months of age). We measured ferritin, iron, total iron binding capacity (TIBC), transferrin saturation rate (TFSAT), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and red cell distribution width (RDW) at birth, 6 months of age, and 12 months of age. Results: 1) At 6 months of age, ferritin, iron, TFSAT, and Hb in Group B were the lowest among the 3 groups, whereas TIBC and RDW were the highest. The incidences of iron deficiency (ID) and iron deficiency anemia (IDA) in Group B were 33% and 30%, respectively, significantly higher than those seen in Groups A (5% and 8%, respectively) and S (7% and 5%, respectively). 2) At 12 months of age, ferritin, TFSAT, Hb, MCV, and MCH in Group B were the lowest among the 3 groups, whereas TIBC and RDW were the highest. Iron and Hct did not differ among the 3 groups. The incidences of ID and IDA in Group B were 64% and 50%, respectively, again significantly higher than those seen in Groups A (4% and 3%, respectively) and S (9% and 7%, respectively). Conclusion: The prevalences of ID and IDA were higher in breast-fed infants than in formula-fed infants, even at 6 months of age. Early and low-dose iron supplementation in breast-fed infants improved iron status and lowered the incidence of iron deficiency anemia in early infancy.

  • PDF

Analysis of Long-Term Performance of Geogrids by Considering Interaction among Reduction Factors (감소계수 상호영향을 고려한 지오그리드의 장기성능 해석)

  • Jeon, Han-Yong;Kim, Yuan-Chun;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.7
    • /
    • pp.55-65
    • /
    • 2012
  • Total reduction factor that is used when calculating allowable tensile strength of geogrids is made by multiplying the installation damage reduction factor ($RF_{ID}$), chemical degradation reduction factor ($RF_D$), and creep reduction factor ($RF_{CR}$) etc. In case of a model estimating allowable tensile strength considering reduction factor over the short-term tensile strength of geogrids, it has a limit of not considering interaction force between reduction factors. Junction strength comes to be reduced by installation damages or chemical degradation in the same way as tensile strength. Single junction test method cannot properly test damaged samples and shows large deviations as it does not consider scale effect. Besides, regarding calculating shear strength, no reasonable study on reduction factors was conducted yet. Therefore, in this study, reduction factors that may affect the long-term performance of geogrids were revaluated considering various conditions and accurate long-term allowable tensile strength was calculated considering interrelation between reduction factors. Creep results after installation damage and chemical resistance test showed lower value than calculated value according to GRI GG-4. After the installation damage test and the chemical resistance test, the reduction factor of junction strength was less than that of tensile strength. Shear strength before and after installation damage showed no change or increase.

In Silico Analysis and Molecular Docking Comparison of Mosquito Oviposition Pheromone and Beta-asarone on the Mosquito Odorant Binding Protein-1 (In Silico 분자결합 분석방법을 활용한 MOP와 베타아사론의 열대집모기 후각단백질 활성 부위에 대한 결합 친화도 비교 분석)

  • Kim, Dong-Chan
    • Journal of Life Science
    • /
    • v.28 no.2
    • /
    • pp.195-200
    • /
    • 2018
  • Beta-asarone is the well-known active ingredient of Rhizoma acori graminei. In this study, we investigated and compared the binding affinity of mosquito oviposition pheromone (MOP; (5R,6S)-6-acetoxy-5-hexadecanolide) and beta-asarone on the A domain of the mosquito odorant binding protein 1 (CquiOBP1) by in silico computational docking studies. The three-dimensional crystallographic structure of CquiOBP1 was obtained from the PDB database (PDB ID: 3OGN). In silico computational auto-docking analysis was performed using PyRx, Autodock Vina, Discovery Studio Version 4.5, and the NX-QuickPharm option based on scoring functions. The beta-asarone showed optimum binding affinity (docking energy) with CquiOBP1 as -6.40 kcal/mol as compared to the MOP (-6.00 kcal/mol). Among the interacting amino acids (LEU76, LEU80, ALA88, MET89, HIS111, TRP114, and TYR122), tryptophan 114 in the CquiOBP1 active site significantly interacted with both MOP and beta-asarone. Amino acids substitution (mutation) from non-polar groups to the polar (or charged) groups of the CquiOBP1 dramatically changed the X, Y, Z grid position and binding affinity of both ligands. These results significantly indicated that beta-asarone could be a more potent ligand to the CquiOBP1 than MOP. Therefore, the extract of Rhizoma acori graminei or beta-asarone can be applied to the fields of insecticidal and repellant biomaterial development.

Nonvisibility and robustness evaluation of image watermarking mixed Key and Logo method (키와 로고 방식을 혼합한 이미지 워터마킹의 비가시성과 강인성 평가)

  • Park, Young;Song, Hag-Hyun;Choi, Se-Ha;Lee, Myong-Kil;Kim, Yoon-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.3
    • /
    • pp.464-469
    • /
    • 2002
  • In this research, nonvisibility and robustness of image watermarking mixed Key and Logo method were evaluated. The role of the Key was performed by a personal ID of a copyrighter and the logo images were used as the watermark. The standard image of Lena was used for experimental image and binary images of `Park'with size 32${\times}$32 and 64${\times}$64 were used for the watermark, respectively In order to evaluate nonvisibility of the proposed watermarking scheme, PSNR(Peak Signal to Noise Ratio) of the watermarked image was obtained and for robustness reconstructive rates of the reconstructed watermark were obtained from the watermarked image with image transformation of JPEG lossy compression. The experimental results show that nonvisibility is excellent as PSNR of the watermarked image is 93.75dB and the reconstructive rates of the case of 322${\times}$32 watermark was better than the case of the 64${\times}$64 watermark; average 5.9%, 13.9%, 6.5%, and 4.2% in the case of scale-down rates, rotational rates, impulse noise power density, and JPEG lossy compression rates, respectively.

Isolation and characterization of Bacillus subtilis NO12 from button mushroom substrates (양송이 배지로부터 분리된 Bacillus subtilis NO12의 특성)

  • Kim, Hye Soo;Park, Hyun Young;Lee, Chan-Jung;Kong, Won-Sik;Cho, Soo Jeong
    • Journal of Mushroom
    • /
    • v.15 no.4
    • /
    • pp.249-253
    • /
    • 2017
  • Twelve strains of bacteria with cellulase and xylanase activities were isolated from spent mushroom substrates collected from button mushroom cultivation farm, Buye, Chungcheongnam-do in Korea. Among them, one strain, designated NO12, with higher cellulase and xylanase activities was selected by agar diffusion method. The strain NO12 was identified to be a Bacillus sp. by biochemical characteristics using Bacillus ID kit and MicroLog system. Comparative 16S rDNA gene sequence analysis showed that strain NO12 formed a distinct phylogenetic tree within the genus Bacillus and was most closely related to Bacillus subtilis with 16S rDNA gene sequence similarity of 99.2%. Based on its physiological properties, biochemical characteristics, and phylogenetic distinctiveness, strain NO12 was classified within the genus Bacillus, for which the name Bacillus subtilis NO12 was proposed. The cellulase and xylanase activities of B. subtilis NO12 were slightly increased according to bacterial population from exponential phase to stationary phase in the growth curve for B. subtilis NO12. The xylanase activity continuously increased from the beginning of the exponential phase and exhibited maximum activity in the middle of the exponential phase.

Preliminary Design of the Forced Gas Drying System for Spent Nuclear Fuel Dry Storage (사용후핵연료 건식저장을 위한 기체강제순환 건조장치 예비설계)

  • Chae, Gyung-sun;Shin, Kyung-wook;Park, Byeong-mok;Han, Jae-hyun;Lee, Geon-hui;Park, Jae-seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.403-409
    • /
    • 2017
  • For dry storage of the spent nuclear fuel (SNF) stored in the storage pool of a nuclear power plant, essentially all moisture must be removed to prevent corrosion of the assembly and canister internals and/or degradation of fuel cladding integrity after SNF canister loading operation. R&D work is now in progress on a forced gas drying system that can be used to remove residual water in canisters. In this work, preliminary design is performed to manufacture the forced gas drying system. This process includes a case study of dry methods for canister moisture removal, relative codes and standards, confirmation of adequate dryness, needs analysis at plant sites, and characteristics of SNF stored in pools. Through this preliminary design work, we obtained a conceptual flow diagram and preliminary P&ID of the forced gas drying system. The results of this study can be used to determine details of the design to manufacture the forced gas drying system.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

$^{99m}Tc-Labeling$ of Monoclonal Antibody to Carcinoembryonic Antigen and Biodistribution (항 암태아성항원에 대한 단세포군항체의 $^{99m}Tc$ 표지법개발 및 생체분포)

  • Moon, Dae-Hyuk;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Chung, Hong-Keun;Park, Jae-Gahb
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.380-391
    • /
    • 1992
  • This study was designed to evaluate a direct method of $^{99m}Tc$ labeling using $\beta-mercaptoethanol$ as a reducing agent, and to investigate whether $^{99m}Tc$ labeled specific monoclonal antibody against carcinoembryonic antigen (CEA-92) can be used for the scintigraphic localization of human colon cancer xenograft. Purified CEA-92 IgG was fragmented into F $(ab')_2$ and then labeled with $^{99m}Tc$ by transchelation method using glucarate as a chelator. Labeling efficiency, immunological reactivity and in vitro stability of $^{99m}Tc$ CEA-92 F $(ab')_2$ were measured and then injected intravenously into nude mice bearing human colon cancer (SNU-C4). Scintigrams were obtained at 24 hour after injection. Then nude mice were sacrificed and the radioactivity was measured Labeling efficiency of injected $^{99m}Tc$ CEA-92 F $(ab')_2$, immunoreative fraction and in vitro stability at 24 hour of injected $^{99m}Tc$ CEA-92 F $(ab')_2$ was 45.2%, 32.8% and 57.4%, respectively. At 24 hour after injection, % ID/g in kidney (46.77) showed high uptake, but %ID/g in tumor (1.65) was significantly higher than spleen (0.69), muscle (0.16), intestine (0.45), stomach (0.75), heart (0.48) and blood (0.45). There was no significant difference between tumor and liver (1.81). Tumor contrast as quantitated by tumor to blood ratio of $^{99m}Tc$ CEA-92 F $(ab')_2$ was increased significantly (p<0.005) until 24 hours (3.70), and there was no statistical differece from tumor to blood ratio of I-131 CEA-92 F $(ab')_2$. The scintigram demonstrated localization of radioactivity over transplanted tumor, but significant background radioactivity was also noted over kidney and abdomen. It is concluded that CEA-92 F $(ab')_2$ can be labeled with $^{99m}Tc$ by a direct transchelation method using $\beta-mercaptoethanol$ as a reducing agent and $^{99m}Tc$ labeled CEA-92 F $(ab')_2$ can be used for the scintigraphic localization of human colon cancer xenograft in nude mice model.

  • PDF