• Title/Summary/Keyword: ID-ICP/MS

Search Result 16, Processing Time 0.024 seconds

Development of a Mushroom Powder Certified Reference Material for Element Analysis

  • Betru, Tegegn Gizachew;Yim, Yong-Hyeon;Lee, Kyoung-Seok
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.108-112
    • /
    • 2020
  • A certified reference material (CRM) for the analysis of nutrient elements in an edible mushroom (Ganoderma lyceum) powder has been developed (KRISS CRM 108-10-011). The mass fractions of calcium (Ca), iron (Fe), and zinc (Zn) were measured by isotope dilution inductively coupled plasma mass spectrometry (ID ICP/MS). To dissolve the fungi cell wall of mushroom consisted of chitin fibers, sample preparation method by single reaction chamber type microwave-assisted acid digestion with acid mixtures was optimized. The mean measurement results obtained from 12 sample bottles were used to assign as the certified values for the CRM and the between-bottle homogeneities were evaluated from the relative standard deviations. The certified values were metrologically traceable to the definition of the kilogram in the International System of Units (SI). This CRM is expected to be used for validation of analytical methods or quality control of measurement results in analytical laboratories when they determine the mass fractions of elements in mushroom or other similar samples.

Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS (후 컬럼 동위원소 희석법을 적용한 HPLC-ICP/MS에서의 정량분석에서 내부 표준물을 이용한 정확도와 정밀도의 개선연구)

  • Joo, Mingyu;Park, Myungsun;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.140-146
    • /
    • 2014
  • An internal standard was used in PCID (post column isotope dilution) to improve the accuracy and precision in quantification of various chemical species. The error occurring in the column was the largest in HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry) when PCID and other traditional quantification methods were compared with each other. Internal standard was effective in correcting the loss of sample in the column to improve accuracy and precision. When applied to SeMet, using MeSecys or $Se^{4+}$ as an internal standard, relative errors were reduced from 31% and 13% to less than 1%, while standard deviations were reduced from 5.1% and 6.9% to 1.5% and 0.2%, respectively. Positive aspects of using an internal standard in PCID were compared with other quantitative techniques and discussed in detail.

Quantitative Speciation of Selenium in Human Blood Serum and Urine with AE- RP- and AF-HPLC-ICP/MS

  • Jeong, Ji-Sun;Lee, Jonghae;Pak, Yong-Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3817-3824
    • /
    • 2013
  • Various separation modes in HPLC, such as anion exchange (AE), reversed-phase (RP), and affinity (AF) chromatography were examined for the separation of selenium species in human blood serum and urine. While RP- and AE-HPLC were mainly used for the separation of small molecular selenium species, double column AF-HPLC achieved the separation of selenoproteins in blood serum efficiently. Further, the effluent of AF-HPLC was enzymatically hydrolyzed and then analyzed with RP HPLC for selenoamino acid study. The versatility of the hybrid technique makes the in-depth study of selenium species possible. For quantification, post column isotope dilution (ID) with $^{78}Se$ spike was performed. ORC ICP/MS (octapole reaction cell inductively coupled plasma/mass spectrometry) was used with 4 mL $min^{-1}$ Hydrogen as reaction gas. In urine sample, inorganic selenium and SeCys were identified. In blood serum, selenoproteins GPx, SelP and SeAlb were detected and quantified. The concentration for GPx, SelP and SeAlb was $22.8{\pm}3.4\;ng\;g^{-1}$, $45.2{\pm}1.7\;ng\;g^{-1}$, and $16.1{\pm}2.2\;ng\;g^{-1}$, respectively when $^{80}Se/^{78}Se$ was used. The sum of these selenoproteins ($84.1{\pm}4.4\;ng\;g^{-1}$) agrees well with the total selenium concentration measured with the ID method of $87.0{\pm}3.0\;ng\;g^{-1}$. Enzymatic hydrolysis of each selenium proteins revealed that SeCys is the major amino acid for all three proteins and SeMet is contained in SeAlb only.

Determination of Mercury in Fly Ash by Using Flow Injection Cold Vapor Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Suh, Jung-Ki;Min, Hyung-Sik;Kamruzzaman, Mohammad;Lee, Sang-Hak
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.58-61
    • /
    • 2012
  • A method based on flow injection-isotope dilution-cold vapor-inductively coupled plasma mass spectrometry (FI-IDCV-ICP/MS) has been applied to determine trace level of mercury in fly ash. $^{200}Hg$ isotopic spike was added to 0.25 g of BCR176R fly ash and then decomposed by microwave digestion procedure with acid mixture A (8 mL $HNO_3$ + 2 mL HCl + 2 mL HF) and acid mixture B (8 mL $HNO_3$ + 2 mL $HClO_4$ + 2 mL HF) for applying IDMS. Mercury cold vapor was generated by using reductant solution of 0.2% (w/w) $NaBH_4$ and 0.05% (w/w) NaOH. The measurements of n($^{200}Hg$)/n($^{202}Hg$) isotope ratio was made using a quadrupole ICP/MS system. The accuracy in this method was verified by the analysis of certified reference material (CRM) of fly ash (BCR 176R). The indicative value of Hg in BCR 176R fly ash was $1.60{\pm}0.23$ mg/kg (k = 2). The determined values of Hg in BCR 176R fly ash by the method of FI-CV-ID-ICP/MS described in this paper were $1.60{\pm}0.24$ mg/kg (k = 3.18) and the analysis results were in well agreement with the indicative value within the range of uncertainty.

Measurement of heavy metals in antarctic soil at the king sejong station: application of isotope dilution inductively coupled plasma mass spectrometry (동위원소희석 ICP-MS분석법에 의한 남극 세종기지 주변 토양의 중금속 측정)

  • Suh, Jung-Ki;Hwang, Euijin;Min, Hyung Sik
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.364-374
    • /
    • 2008
  • Antarctic Environmental Monitoring Handbook' was published by COMNAP/SCAR in 2000. The standardized method described in this handbook is recommended for monitoring of antarctic environment. High pressure bomb technique in this guide was used to decompose soil samples. In compliance with this guide book, high pressure bomb technique was applied to decompose the antarctic soil sampled at the King Sejong Station. An Isotope Dilution-Inductively Coupled Plasma-Mass Spectrometry (ID-ICP-MS) was applied to determine mass concentrations of Pb, Cu and Zn in the soil. The accuracy in this method was verified by the analysis of certified reference materials (CRM) of NIST 2702 (marine sediment). The analytical results agreed with certified value within the range from 99.5~100.8%. Matrix separation was necessitated for the determination of Cu and Zn by Chelex 100 ion exchange resin. As a result, the average mass concentrations of Pb, Cu and Zn which are suspected to be caused by anthropogenic pollution were 332.9 mg/kg, 95.6 mg/kg and 115.3 mg/kg, respectively. Those for the metals sampled in the soils of the remote regions from the station were 28.1 mg/kg, 101.8 mg/kg and 115.6 mg/kg, respectively.

Errors in Isotope Dilution Caused by Matrix-induced Mass Bias Effect in Quadrupole Inductively Coupled Plasma-Mass Spectrometry

  • Pak, Yong-Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3482-3488
    • /
    • 2014
  • Matrix-induced mass bias and its effect on the accuracy of isotope ratio measurements have been examined for a quadrupole-based inductively coupled plasma-mass spectrometer (Q ICP-MS). Matrix-induced mass bias effect was directly proportional to % mass difference, and its magnitude varied for element and nebulizer flow rate. For a given element and conditions in a day, the effect was consistent. The isotope ratio of Cd106/Cd114 under $200{\mu}g\;g^{-1}$ U matrix deviated from the natural value significantly by 3.5%. When Cd 111 and Cd114 were used for the quantification of Cd with isotope dilution (ID) method, the average of differences between the calculated and measured concentrations was -0.034% for samples without matrix ($0.076{\mu}g\;g^{-1}$ to $0.21{\mu}g\;g^{-1}$ for the period of 6 months). However, the error was as large as 1.5% for samples with $200{\mu}g\;g^{-1}$ U. The error in ID caused by matrix could be larger when larger mass difference isotopes are used.

Determination of Cadmium, Copper, Lead, Nickel, and Zinc in Sediments by ID-ICP/MS (동위원소희석 질량분석법에 의한 저니토 중의 카드뮴, 구리, 납, 니켈, 아연의 정량)

  • Cho, Kyung-Haeng;Park, Chang-Joon;Suh, Jung-Kee;Han, Myoung-Sub
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.297-303
    • /
    • 2000
  • Isotope-dilution inductively coupled plasma mass spectrometry was used to determine trace amounts of Cd, Cu, Pb, Ni and Zn in sediment. Sediment samples were dissolved by microwave digestion with addition of mixed acid ($HNO_3$, HF and $HClO_4$). Lead was determined after separation of alkaline and alkaline earth metals by an ammonium pyrrolidenedithiocarbarmate (APDC) solvent extraction. The other elements were determined after separation of iron, tin and titanium by hydroxide precipitation. Recovery efficiency of the analyte elements was not satisfactory, but most of matrix elements causing the isobaric interference could be effectively eliminated by the separation. Good agreement was achieved with the certified values in the analysis of the two sediment reference materials.

  • PDF