• Title/Summary/Keyword: ICD-10

Search Result 183, Processing Time 0.026 seconds

Research about chief complaint and principal diagnosis of patients who visited the university hospital emergency room (응급의료센터를 내원한 환자의 주증상과 주진단 분포에 관한 연구)

  • Lee, Kyung Sook
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.347-352
    • /
    • 2012
  • As medical treatment is developing with technology, the men's average life expectancy is extended. Therefore, primary medical care becomes emphasized in order to reduce the medical expenses in the long term by satisfying individual's life being healthy. The date for this thesis was collected from January 2011 to June 2011. 889 patients who visited the university hospital emergency room and hospitalized in internal medicine, were picked as the research subjects and they were targeted to be recorded the distribution of chief complaint and principal diagnosis of the patients. Also, this record was used to apply to the standard Classification of Diseases(as known as ICD) and the method of detailed classification of the primary medical care(as known as ICPC) to compare each other. In order to analysis, frequency analysis was used to see vital statistics and the cross tabulations were used to see the distribution of chief complaint according to ICD and ICPC. Results of the research were Abdominal pain(17.7%), Dyspnea(13.5%), Fever (12.5%), and Haematemesis (9.8%), and those symptoms represented the 54.5% of overall chief complaints that is treated in primary care. Therefore, it is acceptable to use the classification of the primary medical care at doc-in-a-box. Also, in case of diagnosis of abdominal pain, it is classified to R10 in ICD and 116 patients(18.7%) belonged to it, but according to ICPC, it is subdivided to Epigastric(11.5%) and General(5.8%). ICPC classification, which is focused to primary medical care is more detailed than ICD classification. Because the data that is collected for this thesis is from only one hospital, it is hard to represent to all the cases, but ICPC in emergency medical care, it has more classification available and it can subdivide the patients effectively, so it is meaningful.

Intellectual Capital Disclosure and Its Determinants: Empirical Evidence from Listed Pharmaceutical and Chemical Industry of Bangladesh

  • Rahman, Md. Musfiqur;Sobhan, Raihan;Islam, Md. Shafiqul
    • Asian Journal of Business Environment
    • /
    • v.9 no.2
    • /
    • pp.35-46
    • /
    • 2019
  • Purpose - The purpose of this study is to find out the intellectual capital disclosure (ICD) and its determinants in the pharmaceutical and chemical industry of Bangladesh. Research design, data, and methodology - This research study is conducted on the listed firms of pharmaceutical and chemical industry in Bangladesh during the period of 2016 to 2017. This study develops a self-structured intellectual capital disclosure index; and the proxies of determinants of ICD are used as board characteristics (board size, independent directors and female directors), ownership structures (institutional ownership and director ownership), and firm characteristics (firm size, leverage and performance). The study uses a content analysis to analyze the extent of ICD and a pooled cross-sectional method to find the determinants of ICD. Research Findings - This study finds that intellectual capital disclosure is positively associated with firm size, leverage, and firm performance and negatively associated with director ownership and institutional ownership. This study also finds that there is no significant association of ICD with independent director or female director. Conclusions - The study recommends that the regulatory authority should develop mandatory guidelines on ICD for ensuring proper and consistent disclosure about the intellectual capitals. Besides, the companies should include a separate section in the annual reports to disclose the measurement and management of intellectual capital.

The Impact of Intellectual Capital Disclosure on Firm Performance: Empirical Evidence from Pharmaceutical and Chemical Industry of Bangladesh

  • RAHMAN, Md. Musfiqur;SOBHAN, Raihan;ISLAM, Md. Shafiqul
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.2
    • /
    • pp.119-129
    • /
    • 2020
  • The main purpose of this study is to examine the impact of intellectual capital disclosure (ICD) on firm performance in the pharmaceutical and chemical industry of Bangladesh. In this study, 21 listed pharmaceutical and chemical companies have been selected as sample for 2016 and 2017. This study used the intellectual capital disclosure index developed by Rahman, Sobhan, and Islam. Return on assets and return on equity have been used as the proxy variable of firm performance. In this study, content analysis is performed to assess the level of disclosure regarding intellectual capital and pooled cross-sectional analysis is used to assess the relationship between ICD and firm performance. The study has found a positive and significant relationship between ICD and firm performance. Besides, an in-depth analysis of this study shows that all the components of ICD namely internal capital disclosure, external capital disclosure, and human capital disclosure are also positively and significantly associated with firm performance. The study suggests the development of an intellectual capital disclosure framework by the regulatory authority for mandatory compliance. This will improve the quality and quantity of ICD in the annual reports. Besides, firms should more emphasize on ICD which will help to improve their performance.

The Extent of Intellectual Capital Disclosure and Corporate Governance Mechanism to Increase Market Value

  • SOLIKHAH, Badingatus;WAHYUDIN, Agus;RAHMAYANTI, Anggraeni Anisa Wara
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.119-128
    • /
    • 2020
  • The aim of this paper is to investigate the level of intellectual capital disclosure (ICD) in commercial banks listed on the Indonesian Stock Exchange. This paper also observed the effects of ICD and corporate governance mechanism on market value. This study uses content analysis techniques to measure ICD. The paper provides a novel approach to measure the ICD quality in developing countries using a four-numerical coding system. Secondary data were obtained from the financial statements and annual reports of the banks for the period 2011-2014. The data from 31 banks were analyzed using ordinary least square regression. The study reports that the quality of intellectual capital disclosure in Indonesian commercial banks increase steadily. Narrative disclosure dominates the report of intellectual capital in Indonesian banks. The results indicate that the size of audit committee, frequency of audit committee meeting, and intellectual capital disclosure affect positively the market value. Overall, the results indicate intellectual capital disclosure is associated with the market capitalization; these findings indicate that the ICD is a consideration in a stock investment decision. While regulations in Indonesia regarding intellectual capital reporting are not conclusive yet, the information needs of stakeholders have encouraged companies to expand voluntary disclosure.

Intrapericardial Implantation of an Implantable Cardioverter-Defibrillator in a Child

  • Seong, Yong-Won;Kim, Woong-Han;Yoo, Jae-Suk;Kim, Hye-Seon;Min, Byoung-Ju;Lee, Young-Ok
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.61-63
    • /
    • 2011
  • Implantable cardioverter defibrillator (ICD) can be a crucial therapeutic modality for pediatric patients with congenital heart disease, Brugada syndrome, long QT syndrome and cardiomyopathy. Because transvenous implantation of ICD is mostly unfeasible for pediatric patients due to anatomical and technical limitations, epicardial patch type or subcutaneous type ICD have been used. Implantation of these alternative ICDs, however, was reported to be frequently associated with significant complications. We report a case of successful intrapericardial implantation of a single coil-type ICD through the transverse sinus in a 27 month-old child weighing lesser than 10 kg, and it was inferred from this experience that this alternative technique may decrease complications and morbidities after ICD implantation in children.

The Clinical Indication of Low-Level Laser Therapy Using ICD-10 (ICD-10 분류로 살펴본 저단계 레이저 치료 임상 논문 고찰)

  • Han, Hyeun-jin;Kang, Ki-wan;Kang, Sei-young;Kim, Lak-hyung;Jang, In-soo
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.4
    • /
    • pp.561-569
    • /
    • 2015
  • Objectives The purpose of this study was to improve the knowledge of the low-level laser therapy (LLLT) field and to review research reports on LLLT to understand the current situation with respect to the clinical indication and current research trends.Methods A survey was carried out on the subject of low-level laser therapy to September 2012, using the PubMed search engine. Selected literature was checked by two reviewers and was classified according to the International Classification of Diseases 10th (ICD-10) over 10 years.Results We selected 469 studies in total, of which 142 were case reports, 118 were case-controlled trials, and 209 were randomized controlled trials of LLLT. According to the ICD-10 classification of diseases, the K code and M code being the most common, 399 studies have been published in the last 10 years. This shows that the study and clinical indications of low-level laser therapy have rapidly increased over the past 10 years.Conclusions Low-level laser therapy has been used most frequently with respect to dentistry and pain and musculoskeletal disorders. Recently, interest in and research into LLLT has increased for various diseases. With the establishment of standard conditions for low-level laser therapy, supported by aggressive clinical utilization and systematic clinical research, LLLT will be a very useful treatment and a useful alternative method in many medical fields.

Brachial plexus impingement secondary to implantable cardioverter defibrillator: A case report

  • Jumper, Natalie;Radotra, Ishan;Witt, Paulina;Campbell, Niall G;Mishra, Anuj
    • Archives of Plastic Surgery
    • /
    • v.46 no.6
    • /
    • pp.594-598
    • /
    • 2019
  • Overall complication rates of 9.1% have been reported following implantable cardioverter defibrillator (ICD) placement. Brachial plexus injury is infrequently reported in the literature. We describe a 26-year-old female experiencing left arm nerve pain, a positive Tinel's sign, numbness in the median nerve distribution of the hand and biceps muscle weakness following revision ICD via subclavian vein approach. Nerve conduction studies identified severe partial left brachial plexopathy, which remained incompletely resolved with conservative management. Surgical exploration revealed lateral cord impingement by the ICD generator and a loop of the ICD lead, along with fibrosis, necessitating surgical neurolysis and ICD generator repositioning. As increasing numbers of patients undergo cardiac device implantation, it is incumbent on practitioners to be aware of potential increases in the prevalence of this complication.

Integrated Communication Design Strategies for the Revised Marketing Environment (마케팅환경 변화에 따른 통합커뮤니케이션디자인 전략)

  • Yang, Jae-Bum
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.5
    • /
    • pp.113-121
    • /
    • 2008
  • Researcher tried to argue the possibility of application of visual communication design adapting the marketing environment change on this paper. What is ICD (Integrated Communication Design)? This is a new attempt to treat these common marketing methods, such as, C, I, B, I, TV commercials, newspaper commercials, posters, brochures, DM, package designing, POP, outdoor visual information, web sites etc, as a whole. And no longer treat them as separate pieces as we were doing previously. So I started this research with positive analysis which already has been theoretically discussed based on the documents and researches on the same subject. Through this attempt I tried to examine the possibility of application of ICD. Conclusively, I developed and suggest named the ICD model, by which we could explain the current marketing communication design effort more holistically then ever.

Disagreement of ICD-10 Codes Between a Local Hospital Information System and a Cancer Registry

  • Sriplung, Hutcha;Kantipundee, Tirada;Tassanapitak, Cheamjit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.259-263
    • /
    • 2015
  • Background: In the field of cancer, the ICD-10 coding convention is based on the site of a neoplasm in the body and usually ignores the morphology, thus the same code may be assigned to tumors of different morphologic types in an organ. Nowadays, all general (provincial) and center hospitals in Thailand are equipped with the hospital information system (HIS) database. Objective: This study aimed to find the characteristics and magnitude of agreement represented by the positive predictive value (PPV) of provisional cancer diagnoses in the HIS database in Pattani Hospital in Thailand in comparison with the final cancer diagnosis of the ICD-10 codes generated from a well established cancer registry in Songklanagarind Hospital, the medical school hospital of Prince of Songkla University. Materials and Methods: Data on cancer patients residing in Pattani province who visited Pattani Hospital from January 2007 to May 2011 were obtained from the HIS database. The ICD-10 codes of the HIS computer database of Pattani Hospital were compared against the ICD-10 codes of the same person recorded in the hospital-based cancer registry of Songklanagarind Hospital. The degree of agreement or positive predictive value (PPV) was calculated for each sex and for both sexes combined. Results: A total of 313 cases (15.9%) could be matched in the two databases. Some 222 cases, 109 males and 113 females, fulfilled the criteria of referral from Pattani to Songklanagarind Hospitals. Of 109 male cancer cases, 76 had the same ICD-10 codes in both hospitals, thus, the PPV was 69.7% (95%CI: 60.2-78.2%). Agreement in 76 out of 113 females gave a PPV of 67.3% (95%CI: 57.8-75.8%). The two percentages were found non-significant with Fisher's exact p-value of 0.773. The PPV for combined cases of both sexes was 68.5% (95%CI: 61.9-74.5%). Conclusions: Changes in final diagnosis in the referral system are common, thus the summary statistics of a hospital without full investigation facilities must be used with care, as the statistics are biased towards simple diseases able to be investigated by available facilities. A systematic feedback of patient information from a tertiary to a referring hospital should be considered to increase the accuracy of statistics and to improve the comprehensive care of cancer patients.

Identifying Adverse Events Using International Classification of Diseases, Tenth Revision Y Codes in Korea: A Cross-sectional Study

  • Ock, Minsu;Kim, Hwa Jung;Jeon, Bomin;Kim, Ye-Jee;Ryu, Hyun Mi;Lee, Moo-Song
    • Journal of Preventive Medicine and Public Health
    • /
    • v.51 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Objectives: The use of administrative data is an affordable alternative to conducting a difficult large-scale medical-record review to estimate the scale of adverse events. We identified adverse events from 2002 to 2013 on the national level in Korea, using International Classification of Diseases, tenth revision (ICD-10) Y codes. Methods: We used data from the National Health Insurance Service-National Sample Cohort (NHIS-NSC). We relied on medical treatment databases to extract information on ICD-10 Y codes from each participant in the NHIS-NSC. We classified adverse events in the ICD-10 Y codes into 6 types: those related to drugs, transfusions, and fluids; those related to vaccines and immunoglobulin; those related to surgery and procedures; those related to infections; those related to devices; and others. Results: Over 12 years, a total of 20 817 adverse events were identified using ICD-10 Y codes, and the estimated total adverse event rate was 0.20%. Between 2002 and 2013, the total number of such events increased by 131.3%, from 1366 in 2002 to 3159 in 2013. The total rate increased by 103.9%, from 0.17% in 2002 to 0.35% in 2013. Events related to drugs, transfusions, and fluids were the most common (19 446, 93.4%), followed by those related to surgery and procedures (1209, 5.8%) and those related to vaccines and immunoglobulin (72, 0.3%). Conclusions: Based on a comparison with the results of other studies, the total adverse event rate in this study was significantly underestimated. Improving coding practices for ICD-10 Y codes is necessary to precisely monitor the scale of adverse events in Korea.