• 제목/요약/키워드: ICC

검색결과 664건 처리시간 0.026초

Usefulness of intraoperative transcranial sonography in patients with traumatic brain injuries: a comparison with postoperative computed tomography

  • Mahn Jeong Ha;Seung Han Yu;Jung Hwan Lee;Hyuk Jin Choi;Byung Chul Kim
    • Journal of Trauma and Injury
    • /
    • 제36권1호
    • /
    • pp.8-14
    • /
    • 2023
  • Purpose: The aim of this study was to assess the agreement between intraoperative transcranial sonography (TCS) and postoperative computed tomography (CT) in patients with traumatic brain injuries. Methods: We performed a retrospective cross-sectional study of 35 patients who underwent TCS during surgery, among those who presented to a regional trauma center and underwent decompressive craniectomy between January 1, 2017 and April 30, 2020. Results: The mean difference between TCS and CT in measuring the midline shift was -1.33 mm (95% confidence interval, -2.00 to -0.65; intraclass correlation coefficient [ICC], 0.96; P<0.001). An excellent correlation was found between TCS and CT in assessing contralateral subdural hematomas (ICC, 0.96; P<0.001) and focal hematoma lesions (ICC, 0.99; P<0.001). A very good correlation between TCS and CT was found for measurements of ventricle width (ICC, 0.92; P<0.001). Conclusions: TCS during surgery is considered an effective diagnostic tool for the detection of intraoperative parenchymal changes in patients with traumatic brain injuries.

UCP 600에서의 원본서류와 사본의 수리요건에 관한 연구 (A Study on the Acceptance Requirements of an Original" Document and Copies under UCP 600)

  • 허재창
    • 무역상무연구
    • /
    • 제38권
    • /
    • pp.123-152
    • /
    • 2008
  • It is a basic rule in the credit law that original documents are required unless otherwise stipulated by the credit. Due to modern technology enabling documents to be produced in many ways it may not always to decide whether a document is original or a photocopy. In consideration of modern technology and the advent of new methods of document production, ICC has drawn up the provisions on original documents in Article 22 (b) of UCP 400 for the first time. The equivalent provision in UCP 500 is Article 20 (b). As a result of many queries to ICC Banking Commission on what constitutes an "original" documents under UCP 500 and several court cases in connection with original documents, the ICC Banking Commission has issued Decision on original documents in July 1999. Based on this Decision, the ICC dealt it in Article 17 under UCP 600 which came into force on July 1, 2007. There are some changes, replacements and new provisions of UCP 600 concerning original documents and copies. Importers, exporters, insurance companies, other third parties and, above all, banks should pay attention to some changes and implications of UCP 600 concerning original documents and copies. The purpose of this paper is to examine the provisions on original documents and copies under UCP 600. For this purpose, firstly this study deals with the relative provisions on original documents and copies under pre-UCP 600. Secondly this study considers the provisions on original documents and copies under UCP 600. Thirdly this study compares the provisions under pre-UCP 600 with the provisions under UCP 600. Finally this study analyzes the cases decided both home and abroad in connection with original documents. This paper contribute to help the parties to letters of credit to understand the provisions on original documents and copies under UCP 600.

  • PDF

Reliability and Validity of Measurement Using Smartphone-Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion

  • Jeon, In-Cheol;Kwon, Oh-Yun;Weon, Jong-Hyuck;Ha, Sung-Min;Kim, Si-Hyun
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.60-68
    • /
    • 2013
  • The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.

뇌졸중 환자의 수동적 어깨 관절 가동범위 측정에 관한 스마트폰과 측각기의 측정자내, 측정자간 신뢰도 연구 (Intra- and Inter-Rater Reliability of Measuring Passive Range of Shoulder Motion With Smartphone and Goniometer in Patients With Stroke)

  • 박일우;임원빈;박규남;이충휘
    • 한국전문물리치료학회지
    • /
    • 제21권1호
    • /
    • pp.1-12
    • /
    • 2014
  • The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the "Clinometer + bubble level", a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at $90^{\circ}$ abduction; ER90 and internal rotation at $90^{\circ}$ abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75~.87] and excellent in ER90 [ICC (2,1)=.90~.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.

만성 뇌졸중 환자들의 Step Test의 상대적·절대적 신뢰도와 타당도 (The Relative·Absolute Reliability and Validity of Step Test in Patients with Chronic Stroke)

  • 이병권;최현수;안승헌
    • 대한통합의학회지
    • /
    • 제5권1호
    • /
    • pp.43-53
    • /
    • 2017
  • Purpose : To examine the relative absolute reliability and validity of step test (ST) scores in subjects with chronic stroke. Method : A total of 27 stroke patients, participated in the study. A relative reliability index (intraclass correlation coefficient, ICC) was used to examine the level of agreement of inter-rater test-retest reliability for ST score. Absolute reliability indices, including the standard error of measurement(SEM) and the minimal detectable change (MDC), and limits of agreement by Bland and Altman analysis. The validity was demonstrated by spearman correlation of ST score with 10 m Walk Test (10mWT), Fugl-Meyer Assessment-Lower/Extremity (FMA-L/E)-total score, Berg Balance Scale (BBS)-total score. Result : An excellent inter-rater reliability in ST scores was found (paretic, ICC=0.993~0.996; nonparetic, ICC=0.982~0.991). In addition, excellent test-retest reliability was found (paretic, ICC=0.992; nonparetic, ICC=0.967). It all showed acceptable SEM of the ST score as paretic and nonparetic were 0.22 and 0.46 respectively (average score <10 %), and the MDC of the paretic and nonparetic were 0.61 and 1.27 respectively (possible highest score <20 %). indicating that measures had a small and acceptable measurement error. The ST score of paretic and nonparetic were also found to be significantly associated with 10MWT (r=0.77~0.79), FMA-LE scores (r=0.73~0.81) and BBS scores (r=0.72~0.76). Conclusion : The ST showed highly sufficient Inter-rater test-retest agreement and validity and acceptable measurement errors caused by due to chance variation in measurement. It also can be used by clinicians and researchers to assess the balance and mobility performance and monitor functional change in chronic stroke patients.

The Reliability of Thickness Measurement of the Deep Fiber of the Lumbar Multifidus Using Ultrasonography

  • Jung, Doh-Heon;Kim, Su-Jung;Yi, Chung-Hwi;Cynn, Heon-Seock;Choi, Houng-Sik
    • 한국전문물리치료학회지
    • /
    • 제17권4호
    • /
    • pp.49-54
    • /
    • 2010
  • The reliability of the thickness measurement of the lumbar multifidus (LMD using real-time ultrasonography (US) was determined in only the superficial fiber of the lumbar multifidus (SM). However, previous studies have not examined the reliability of the deep fiber of the LM (DM). The purpose of this study was to determine the intrarater and the interrater reliability of the thickness measurements of DM using US. Eleven heathy males participated in the study. The thickness of the DM was measured with an US in the prone position. Reliability was examined using intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and the Bland and Altman plot. ICC(3,1) was used to calculate the interrater reliability of the thickness measurement of DM using the values from both the first and second test sessions. Additionally, ICC(3,1) was used to calculate the intrarater reliability of the measurements over two days using the measurements obtained in test session 1 and lest session 2. The results of this study were as follows: 1) the ICC(3,1) value for interrater reliability was .94 in the first test session, and .93 in the second test session. 2) the ICC(3,1) values for intrarater reliability of the measurements over two days was .90 in both the first examiner and the second examiner. The interrater reliability and interrater reliability of the DM measurements, obtained via the US protocol used in this research was excellent. Therefore, we conclude that the thickness measurement of the DM obtaioned from the US protocol used in this research would be useful for clinician assessment of the thickness of the DM.

국제기술이전계약(國際技術移轉契約)의 몇 가지 주요쟁점 검토 - ICC Model International Technology Transfer Contract(2009)를 중심으로 - (A Study on Several Points at Issue in International Technology Transfer Contract - Focusing on ICC Model International Technology Transfer Contract(2009) -)

  • 오원석
    • 무역상무연구
    • /
    • 제59권
    • /
    • pp.3-26
    • /
    • 2013
  • The purpose of this paper is to examine the several points at issue in international technology transfer contract from licensor's and licensee's perspectives, and to refer them when the licensor and the licensee draw up the contract. This author analyzed the critical points of the related provisions of ICC Model International Technology Transfer Contract(2009) by citing the explanations of the Introduction of the Model Contract. The provisions of the Model Contract are generally divided into two categolies; specific conditions and general conditions. This author selected four topics in the specific conditions; Contents of the Contract, Royalty, Modification and/or Improvements of Products, and Territory and Competition. Likewise this author selected three topics in the general conditions; Resolutions of Disputes, Applicable Law and Taxes. Both parties need to be mindful of the following points in the above topics, when they draw up the contract. First, both parties should make the definitions of special terminologies clear, which are included in the Contract. Second, before the parties sign the Contract, they should check any approvals to be necessary by the both countries' governments. Third, for the calculation of the royalty, they should clear the criteria, the scope, and the object. Fourth, as the local laws or regional laws regarding the territory limitation and taxation are mandatory, any provisions of the Contract should not be inconsistent with them. Therefore, both parties should check before-hand the local laws or rules related with the provisions of the Contract. Fifth, when the parties draw up the Contract, they should examine the Provisions of Dispute Resolution in consideration of the Governing Law. Thus both parties decide to make the technology transfer contract, the three aspects namely profitability, legal conflict with mandatory rules, and sustainability of the business resulting from the Contract should be examined in advance, and then proceed the business using the technology transfer.

  • PDF

Intra- and Inter-rater Reliabilities of Infrasternal Angle Measurement

  • Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • 제27권3호
    • /
    • pp.154-158
    • /
    • 2015
  • Purpose: The purpose of this study was to propose a new reference point for measurement of the infrasternal angle and to investigate the intra- and inter-rater reliabilities of infrasternal angle measurement using photographs. Methods: Twenty-four healthy male college students participated as subjects in this study. Photographs were taken of subjects in two postures, one standing with the shoulders relaxed and one standing with the shoulders at $150^{\circ}$ abduction. All photographs were analyzed using Image J software. Raters used the photographs to measure the infrasternal angle between the xiphoid process, the medial margin of rib and navel on the right and left sides. The reliability of the infrasternal angle measurement was assessed by means of intraclass correlation coefficients [ICC (3,1)]. The level of statistical significance was set at p<0.05. Results: The intra- and inter-rater reliabilities of the infrasternal angle measurement for the right side at rest were excellent (ICC=0.866 and 0.813, respectively), as were those for the left side at rest (ICC=0.919 and 0.846, respectively). At $150^{\circ}$ shoulder abduction, the intra- and inter-rater reliabilities for measurement of the infrasternal angle on the right side were excellent (ICC=0.972 and 0.778, respectively), as were those for the left side (ICC=0.914 and 0.826, respectively). Conclusion: These findings suggest that this technique can be successfully used to measure the infrasternal angle, thus suggesting a new reference point for determining the length of the internal oblique and external oblique muscles in clinical situations.

ICC규정상 ICC수사관에 의한 단속범죄의 한계 (The Statute of the International Criminal Court of the Control Crime Due to the Regulation Coat Investigators of ICC)

  • 유인창
    • 한국콘텐츠학회논문지
    • /
    • 제6권1호
    • /
    • pp.85-92
    • /
    • 2006
  • 집단살해, 인도에 반하는 범죄와 전쟁 범죄가 정당화 될 수 있거나, 방어적인 힘, 자위권, 기타의 방어와 소유권의 방어에 의해 면책될 수 있었던 것은 상당히 부조리하게 보인다. 그럼에도 불구하고, 국제형사재판소의 로마규정 제31조(1)(c)는 형사책임을 제외할만한 근거로서 방어적인 힘을 성문화하고 있다. 이 조항은 논의의 여지가 있고 주로 세계의 여러 가지 국내의 법률 제도 사이에 범죄의 방어에 관해서 존재하는 개념적 차이 때문에 1998년 로마 회의에서 협정하기 상당히 어려웠다. 이 논문은 로마규정 제31조(1)(c)항의 배경과 그 역사, 로마규정의 아래에서 방어적인 힘의 정확한 범위를 차례로 해명하기 위해 분석한다. 그 다음 집단살해죄, 인도에 반하는 죄와 전쟁범죄에서 조항의 적용성을 확인한다. ICC검찰국의 수사관이 실제로 ICC규정상 범죄행위에 대하여 수사를 할 것이다. 수사관이 수사를 할 각 범죄에 대한 구성요건을 살펴볼 것이다.

  • PDF

어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교 (A Comparison of Reliability and Anterior Glide Distance of Humerus Head of Passive Shoulder Internal Rotation Range of Motion Measurement Methods)

  • 김현숙;이원휘;정성대
    • 한국전문물리치료학회지
    • /
    • 제17권3호
    • /
    • pp.1-10
    • /
    • 2010
  • The purpose of this study was to measure intra-rater and inter-rater reliability and range of motion for measurement of passive shoulder internal rotation range of motion and to compare anterior glide distance of humeral head in three methods. Fifty healthy subjects and fifty patients with shoulder musculoskeletal pain were recruited for this study. The subjects' passive shoulder internal rotation range of motion was measured by visual estimation, manual stabilization, and pressure biofeedback unit methods. In two trials, measurements were performed on each subject by two examiners. Intraclass correlation coefficient (ICC(3,1)) was used to determine the reliability of each measurement. The intra-rater reliability of the three methods was excellent (ICC=.77~.93) in both groups. The inter-rater reliability of the visual estimation method was poor (ICC=.20, .29), the manual scapular stabilization method was poor and fair (ICC=.09, .50), and the pressure biofeedback unit method was excellent (ICC .86, .75) in the experimental and control groups. In the experimental group, the difference of examined range of motion by each examiner was significant in the visual estimation method and manual scapular stabilization method, but there was an insignificant difference between the groups is the pressure biofeedback unit method. This result suggests that the intra-rater and inter-rater reliability of a pressure biofeedback unit was better than the other methods. The difference in distance of the anterior glide of humeral head was insignificant among all the methods. The pressure biofeedback unit method was the most reliable method, so it is proposed to be a new and reliable method to measure internal rotation range of motion.