• Title/Summary/Keyword: IC Method

Search Result 1,050, Processing Time 0.028 seconds

An Improved PFC & Low Noise Power Supply using Quasi-Resonant Mode Hybrid IC of STR-G9600 (의사공진형 Hybrid IC STR-G9600을 이용한 저 노이즈 역률 개선형 전원 장치)

  • Lee Myung Jun;Ahn Jun Young;Shin Ho Jun;Bae Jun Sung
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.233-236
    • /
    • 2002
  • The solution for PFC(Power Factor Correction), as a regulation in energy Policy, is becoming a hot Issue in every country because of the shortage of electrical energy. Therefore, a new improved idea for PFC problem has been introduced in this study. A lot of merits, effective cost by simple circuit, reduced PCB size, lighter than reactor in the view of weight, lower level of screen noise by leakage inductance in CTV applications, have been stated by comparing to the earlier method of using a Reactor. All test results in this statement were done by using a power device of STR-G9600 series based on the real load condition of color television. furthermore, the study shows that the test results also meets the IEC-1000-3-2 class D, which regulates the PFC when input power of a set is more than 75watts. More improved PFC in other applications hopes to be implemented by using the proposed method.

  • PDF

A prediction of the thermal fatigue life of solder joint in IC package for surface mount (표면실장용 IC 패키지 솔더접합부의 열피로 수명 예측)

  • 윤준호;신영의
    • Journal of Welding and Joining
    • /
    • v.16 no.4
    • /
    • pp.92-97
    • /
    • 1998
  • Because of the low melting temperature of solder, each temperature cycle initiates an irrecoverable creep deformation at the solder interconnection which connects the package body with the PCB. The crack starts and propagates from the position where the creep deformation is maximized. This work has tried to compare and analyze the thermal fatigue life of solder interconnection which is affected by the lead material, the size of die pad, chip thickness, and interface delamination of 48-Pin TSOP under the temperature cycle ($0^{\circ}C$~1$25^{\circ}C$). The crack initiation position and thermal fatigue life which are calculated by using FEA method are well matched with the results of experiments. The thermal Fatigue life of copper lead frame is extended around 3.6 times longer than that of alloy 42 lead frame. It is maximized when the chip size is matched with the length of the lead. It tends to be extended as the thickness of chip got thinner. As the interfacial delamination between die pad and EMC is increased, the thermal fatigue life tends to decrease in the beginning of delamination, and increase after the delamination grew after 45% of the length of die pad.

  • PDF

Design and fabrication of the Built-in Testing Circuit for Improving IC Reliability (IC 신뢰성 향상을 위한 내장형 고장검출 회로의 설계 및 제작)

  • Ryu, Jang-Woo;Kim, Hoo-Sung;Yoon, Jee-Young;Hwang, Sang-Joon;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.5
    • /
    • pp.431-438
    • /
    • 2005
  • In this paper, we propose the built-in current testing circuit for improving reliability As the integrated CMOS circuits in a chip are increased, the testability on design and fabrication should be considered to reduce the cost of testing and to guarantee the reliability In addition, the high degree of integration makes more failures which are different from conventional static failures and introduced by the short between transistor nodes and the bridging fault. The proposed built-in current testing method is useful for detecting not only these failures but also low current level failures and faster than conventional method. In normal mode, the detecting circuit is turned off to eliminate the degradation of CUT(Circuits Under Testing). The differential input stage in detecting circuit prevents the degradation of CUT in test mode. It is expected that this circuit improves the quality of semiconductor products, the reliability and the testability.

Intermediate crack-induced debonding analysis for RC beams strengthened with FRP plates

  • Wantanasiri, Peelak;Lenwari, Akhrawat
    • Structural Engineering and Mechanics
    • /
    • v.56 no.3
    • /
    • pp.473-490
    • /
    • 2015
  • This paper presents the analysis of intermediate crack-induced (IC) debonding failure loads for reinforced concrete (RC) beams strengthened with adhesively-bonded fiber-reinforced polymer (FRP) plates or sheets. The analysis consists of the energy release and simple ACI methods. In the energy release method, a fracture criterion is employed to predict the debonding loads. The interfacial fracture energy that indicates the resistance to debonding is related to the bond-slip relationships obtained from the shear test of FRP-to-concrete bonded joints. The section analysis that considers the effect of concrete's tension stiffening is employed to develop the moment-curvature relationships of the FRP-strengthened sections. In the ACI method, the onset of debonding is assumed when the FRP strain reaches the debonding strain limit. The tension stiffening effect is neglected in developing a moment-curvature relationship. For a comparison purpose, both methods are used to numerically investigate the effects of relevant parameters on the IC debonding failure loads. The results show that the debonding failure load generally increases as the concrete compressive strength, FRP reinforcement ratio, FRP elastic modulus and steel reinforcement ratio increase.

Effect of Cerium Doping on Superconducting Properties of YBCO Film Prepared by TFA-MOD Method (MOD-TFA공정에 의한 YBCO박막 제조 시 cerium첨가효과에 관한 연구)

  • Yi, Keum-Young;Kwon, Youn-Kyung;Kim, Byeong-Joo;Lee, Hee-Gyoun;Hong, Gye-Won;Yoo, Jai-Moo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.33-34
    • /
    • 2006
  • The effects of Ba and Ce addition has been investigated in YBCO prepared by trifluoroacetate (TFA) metalorganic depostition (MOD) method. Precursor solutions with cation ratios of Y:Ba:Cu:Ce = 1:2+x:3:x (x = 0, 0.05, 0.1 and 1.5) have been prepared by adding an excess amount of cerium and barium. Coated film was calcined at lower temperature and conversion heat treatment at temperature of $780{\sim}810^{\circ}C$. It has been shown that the critical current (Ic) of YBCO film was degraded by doping of Ba and Ce atoms. But Ic was increased as the amount of doped Ba and Ce content increased from 5 % to 15 %. It was observed that there was little increase of a flux pinning force with Ba and Ce addition in YBCO film prepared by TFA-MOD process.

  • PDF

Accuracy and Precision of Ion Chromatography/Visible Absorbance Detection for Analyzing Hexavalent Chromium Collected on PVC Filter (Ion Chromatography/Visible Absorbance Detection을 이용한 Cr(VI) 분석의 정확도 및 정밀도 평가)

  • Shin, Yong Chul;Oh, Se Min;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.223-232
    • /
    • 1997
  • The accuracy and precision of a modified method of NIOSH Method 7600 and EPA method 218.6 was determined for analyzing hexavalent chromium, Cr(VI), collected on PVC filter from workplace air. The method was designed to extract from Cr(VI) on PVC filter with a alkali solution, 2% NaOH/3% $Na_2CO_3$, and to analyze it using ion chromatography/visible absorbance detection(IC/VAD). The results and conclusion are as the following. 1. The peak of Cr(VI) was separated sharply on chromatogram and was linearly related with Cr(VI) concentration in sloution. The correlation coefficient was 0.9999 in a calibration curve. The limit of detection was 0.25 $0.25{\mu}g/sample$. 2. The accuracy(% recovery) was 93.3% in a set of sample($9-50{\mu}g$) stored for a day, and 100.1%($10-60{\mu}g$) in another set of samples stored for 2 hours. It is assumed that the difference in recovery by storage time was due to reduction of Cr(VI) to Cr(III). 3. The precision(coefficient of variation, CV) of the method was 0.015 in spiked samples with Cr(VI) standard solution, and 0.010 in spiked samples with plating solution from a chrome electroplating factory. The overall CV in all types of samples was 0.0013. 4. The Cr(VI) was stable in 2% NaOH/3% $Na_2CO_3$ at least for 10 hours. In conclusion, the IC/VAD method is appropriate for determining low-level Cr(VI) in workplace air containing various interferences.

  • PDF

Development of multi filament cable with Bi high-Tc superconducting system (Bi계 고온초전도 다심케이블 제작에 관한 연구)

  • 김민기;강형곤;최효상;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.11a
    • /
    • pp.43-46
    • /
    • 1993
  • Superconducting cable (Ic: 60 A at 77K. 10 filaments) with Bi high-Tc superconducting system was developed by powder - in - tube method. Pressing and sintering process of the cables were repeated for growth of 2223 high-Tc superconducting phase. The cable can be fabricate by twist method that is nessary for high current density and cooled circulative system. This cab1e system can be used for commercial.

  • PDF

The Efficient Memory Mapping of FPGA Implemenation for Real-Time 2-D Discrete Wavelet Transform using Mallat tree algorithm (Mallat tree 방법을 이용한 실시간 2-D DWT의 FPGA 구현을 위한 효율적인 메모리 사상)

  • 김왕현;서영호;김종현;김동욱
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.105-108
    • /
    • 2001
  • This paper proposed an efficient memory scheduling method (E$^2$M$^2$) by which the real-time image compression using 2-dimensional discrete wavelet transform(2-D DWT) is possible in an FPGA chip. In this paper, we assumed that the 2-D DWT was performed as the Mallat-tree. After the memory mapping method was proved in software, the memory controller was designed for an commercial SDRAM IC.

  • PDF

Fast exponentiation with modifed montgonmery modular multiplication (Montgomery 모듈라 곱셈을 변형한 고속 멱승)

  • 하재철;문상재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.1036-1044
    • /
    • 1997
  • We modify the montgomery modeular multikplication to extract the common parts in common-multiplicand multi-plications. Since the modified method computes the common parts in two modular multiplications once rather than twice, it can speed up the exponentiations and reduce the amount of storage tables in m-ary or windowexponentiation. It can be also applied to an exponentiation mehod by folding the exponent in half. This method is well-suited to the memory limited environments such as IC card due to its speed and requirement of small memory.

  • PDF

Efficient Approach to Thermal Modeling for IC Packages (효율적 수치해석기법을 이용한 반도체 페키지의 열방출 해석)

  • Seung Mo Kim;Choon Heung Lee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.2
    • /
    • pp.31-36
    • /
    • 1999
  • An efficient method for thermal modeling of QFP is Proposed. Thermal measurement data are given to verify the method. In parallel with the experiment, an exact full 3-D model calculation is also provided. One fonds that there is an excellent agreement between validation data and the efficient model data.

  • PDF