• Title/Summary/Keyword: IC Method

Search Result 1,050, Processing Time 0.032 seconds

Rapid Analytical Method of Nitrite and Nitrate in Fish by Ion Chromatography

  • Oh, Myung-Cheol;Oh, Chang-Kyung;Kim, Soo-Hyun
    • Preventive Nutrition and Food Science
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 1996
  • Rapid analytical method was investigated to determine precursors of N-nitrosamine such an nitrite and nitrate in squid(Illex illecebrosus and Sepiell maindroni), codfish(Gadus marcrocephalus)and flatfish(Paralichthys olivaceus) by ion chromatography(IC) and colorimetric methods. Recoveries of nitrite and nitrate in fish tissues were 89~98.7% and 94.1~99.8% for IC, and 98.4~103.7% and 67.7~102.2% for colori-metric method, respectively. Using IC, nitrite was not detected and nitrate was 0.89~1.23mg/kg, while using colorimetric method, nitrite and nitrate were NO~0.08mg/kg and 0.3~0.42mg/kg, respectively. Therefore, the IC method showed better recoveries, and was applicable to extract nitrite and nitrate simultaneously, and is simpler compared with colorimetric method in analyzing nitrite and nitrate from fish tissues.

  • PDF

Modified LOGIT(MLOGIT) Transformation: Prediction of $IC_{50}$ Value from Two Arbitrary Concentration Data

  • 유성은;차옥자
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.2
    • /
    • pp.110-112
    • /
    • 1995
  • A LOGIT transformation is a method to estimate IC50 values with two arbitrary concentration data when complete dose response curves(DRCs) are not available. We propose a modified LOGIT transformation (MLOGIT) which predicts IC50 values more accurately than the conventional LOGIT method.

Fault Tree Analysis and Fault Modes and Effect Analysis for Security Evaluation of IC Card Payment Systems (IC카드 지불결제 시스템의 보안성 평가를 위한 고장트리 분석(FTA)과 고장유형과 영향 분석(FMEA))

  • Kim, Myong-Hee;Jin, Eun-Ji;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.1
    • /
    • pp.87-99
    • /
    • 2013
  • The demands of IC card payment system has been increased according to the rapid advancement of the IT convergence application technologies. Recently IC card payment systems are in demands of the usage space at anytime and anywhere by developing the wireless communication technology and its related multimedia processing technology. Therefore the security of IC card payment system becomes more important and necessary. There are many fault analysis methods to evaluate the security and safety of information systems according to their characteristics and usages. However, the only assessment method to evaluate the security of information systems is not enough to analyse properly on account of the various types and characteristics of information systems by the progress of IT convergence and their applications. Therefore, this paper proposes an integrative method of the Fault Tree Analysis (FTA) and Fault Modes and Effect Analysis/Criticality (FMEA/C) based on criticality to evaluate and improve the security of IC card payment system as an illustration.

A Study on the Application Method of Various Digital Image Processing in the IC Package (IC-패키지에 대한 각종 디지탈 화상처리 기술의 적용방법에 대한 연구)

  • Kim, Jae-Yeol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.12 no.4
    • /
    • pp.18-25
    • /
    • 1993
  • This paper is to aim the microdefect evaluation of If package into a quantitative from NDI's image processing of ultrasonic wave. (1) Automatically repeated discrimination analysis method can be devided in the category of all kind of defects on IC package, and also can be possible to have a sampling of partial delamination. (2) It is possible that the information of edge section in silicon chip surrounding can be extractor by the partial image processing of IC package. Also, the crack detection is possible between the resin part and lead frame.

  • PDF

A Study on the Small Signal Modeling of Smart Power IC

  • Xu, Hai;Kim, Hee-Jun;Cho, Kyu-Min
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1140-1141
    • /
    • 2007
  • A method of modeling the Smart Power IC is presented in this paper, which is based on the IC's typical operation characteristics and small signal frequency response data. Using the least square identification, the IC's dynamic mathematical model, which is expressed as transfer function, can be synthesized from the experimentally obtained gain and phase data. The practicability and effectiveness of the method are verified by means of experiments.

  • PDF

On the Linear Harmonic Analysis of Engine Exhaust and Intake Systems

  • Peat, Keith
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.27-33
    • /
    • 2001
  • Linear harmonic analysis is a convenient and generally accurate method to use for the acoustic analysis of intake and exhaust silencers for IC engines. The major uncertainty in this form of modelling is the characterisation of the source, which is inherently nonlinear and time-variant. Experimental methods are generally used to determine the source characteristics, and in particular the indirect method is most suitable for an IC-engine source. With reference to an idealised linear time-variant source, it is found that the characteristics of a time-variant source as determined by the indirect method have no physical relevance. The direct method of experimental measurement appears to have some advantage over the indirect method, although in practice it is difficult to apply to an IC engine source. Again, an idealised linear time-variant source can be used to indicate that the characteristics of a time-variant source as determined by the direct method also have no physical relevance. Strangely, these meaningless measured source properties can nevertheless be used to accurately predict the radiated noise from an IC engine and silencer system.

  • PDF

Comparison of Analysis Methods for Ammonia from Swine Production Facilities

  • Kim, Ki Y.;Choi, Hong L.;Kim, Chi N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.11
    • /
    • pp.1608-1614
    • /
    • 2004
  • This study was performed to evaluate the accuracy, validation and applicability of UV spectrophotometer (UV), Ion Chromatography (IC), and Detector tube (DT) methods for measuring ammonia (NH3) concentration in a swine confinement house and swine slurry storage tank. The mean values of $NH_{3}$ emitted from the house and slurry were 5.333 ppm and 42.192 ppm for the IC method; 4.13 ppm and 36.29 ppm for the Detector tube; and 5.417 ppm and 34.193 ppm for the UV method. The accuracy and the correlation of an ammonia level analyzed by the IC method compared to the UV method were 98% and 0.998($R^{2}$) in the swine confinement house and 94% and 0.997($R^{2}$) in the swine slurry storage tank. On the other hand, those of ammonia level measured by the Detector tube compared to the UV method were 77% and 0.957($R^{2}$) in the swine confinement house and 82% and 0.941($R^{2}$) in the swine slurry storage tank. This indicated that the accuracy and the correlation of the IC method compared to the UV method were higher than those of the Detector tube method compared to the UV method. Therefore, it was concluded that the IC method was more accurate in measuring ammonia concentration in a swine house and a swine slurry storage tank. The Detector tube method should not be applied to the swine slurry storage tank in which ammonia concentration is generally higher than 30 ppm because low accuracy is caused by a gross space between scales inscribed in the Detector tube.

Determination of Mode I Fracture Toughness of Fiber Reinforced Composites by the Elastic Work Factor (섬유강화 복합재의 $G_ {IC}$ 결정을 위한 일인자방법)

  • Lee, Gyeong-Yeop;Go, Seung-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.11
    • /
    • pp.3491-3497
    • /
    • 1996
  • The work factor approach was applied to determine $G_ {IC}$ of fiber reinforced composites (AS4/3501) from a single unidirectional (0-deg) DCB specimen. Elastic work factors of DCB specimen for three different symmetrical staking sequences were derived from a simple bending theory and a finite element method. The results showed that elastic work factors calculated from both methods were comparable each other. In particular, the elastic work factor of DCB specimen with symmetrical stacking sequence is independent of stacking sequence. The $G_ {IC}$ determined from the work factor approach was compared with that determined by the compliance method. The results showed that the work factor approach and the compliance method produce comparable results of $G_ {IC}$. Thus, $G_ {IC}$ can be determined from a single DCB specimen using the work factor approach.

Prediction of crack propagation path in IC package by BEM (경계요소법에 의한 반도체 패키지의 균열진전경로 예측)

  • Song, Chun-Ho;Chung, Nam-Yong
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.286-291
    • /
    • 2001
  • Applications of bonded dissimilar materials such as IC package, ceramic/metal and resin/metal bonded joints, are very increasing in various industry fields. It is very important to analyze the thermal stress and stress singularity at interface edges in bonded joints of dissimilar materials. In orer to understand the package crack emanating from the edge of Die pad and Resin, fracture mechanics of bonded dissimilar materials and material properties are obtained. In this paper, the thermal stress and its singularity index for the IC package were analyzed using 2-dimensional elastic boundary element method. Crack propagation angle and path by thermal stress were numerically simulated with boundary element method.

  • PDF

A Study on the Elasto-Plastic Fracture Toughness $J_IC$ Evaluation of Carbon Steel (탄소강의 탄소성파괴인성 $J_IC$ 평가에 관한 연구)

  • Kim, Hei-Song;Ahn, Byoung-Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.3
    • /
    • pp.90-99
    • /
    • 1989
  • In this study, J-integral values obtained by various methods, i.e, R-Curve, Unloading Compliance, Strectched Zone Width [SZW], and Acoustic Emission [AE] methods are investigated. Elasto-plastic fracture toughness [$J_IC$] estimations by R-curve method are overestimated than those by SZW method, and those by unloading compliance method is around middle value of them. And the difference between them is little. The $J_IC$ value by AE method was almost agreed with that by SZW, and then proved to be useful. Crack propagation mechanism on fractography is a stable ductile fracture. For the identification of ductile fracture, both fractography analysis and AE method were applied to estimate the characteristics more precisely.

  • PDF