• Title/Summary/Keyword: IAQ (indoor Air Quality)

Search Result 188, Processing Time 0.029 seconds

Development of Home Indoor Air Quality evaluation program considering planning and construction stage (주거 건물의 설계 및 시공단계를 고려한 실내공기질 평가 프로그램 개발에 관한 연구)

  • Choi, Dong-Hee;Kang, Dong-Hwa;Kim, Sun-Sook;Yeo, Myoung-Seok;Kim, Kwang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.51-56
    • /
    • 2005
  • The objective of this study is to develop Home Indoor Air Quality evaluation prorgram considering planning and construction stage for architects, engineers and occupants to estimate and improve the IAQ of a home. In this study, the IAQ modeling technique was discussed to determine the appropriate modeling of housing unit in Korea. The program algorithm was developed based on the selected model reflecting planning and construction stage. This program can be applied to estimate the IAQ of a home and encourage appropriate action in advance.

  • PDF

Indoor Air Quality and Human Health Risk Assessment for Un-regulated Small-sized Sensitive Population Facilities (소규모 다중이용시설의 실내공기질 실태조사 및 건강위해성평가: 민감군 이용시설을 중심으로)

  • Shin, Hyejin;Park, Woosang;Kim, Bokyung;Ji, Kyunghee;Kim, Ki-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.397-407
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate human health risk assessment of indoor air pollutants at small-sized public-use facilities (e.g., daycare centers, hospital and elderly care facilities) that the susceptible population is mainly used. Methods: To assess indoor air quality (IAQ), the concentrations of indoor air contaminants such as HCHO, benzene, toluene, ethylbenzene, xylene, styrene, PM-10, CO, $NO_2$ and $O_3$ in air samples were measured according to the Indoor Air Quality Standard Method. By conducting the questionnaire survey, the major factors influencing IAQ were identified. Human health risk assessment was carried out in the consideration of type of use (user and worker) at 75 daycare centers, 34 hospitals and 40 elderly care facilities. Results: As a result of measurement of indoor air contaminants, the average concentration of HCHO and TVOCs in hospitals was higher than daycare centers and elderly care facilities, about 8.8 and 23.5% of hospitals were exceeded by IAQ standard. In human health risk assessment, for the user of daycare centers and elderly care facilities, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value. Except for HCHO, other values were determined under acceptable risk. Similarly, for the worker of hospitals, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value and other values were evaluated under acceptable risk. In contrast, the risk levels of other contaminants measured in elderly care facilities were acceptable. In the determination of factors influencing IAQ, the construction year, building type, ventilation time, and the use of air cleaner were identified. Conclusions: This study provides the information for establishing the plans of public health management of IAQ at small-sized public-use facilities that have not yet been placed under the regulation. The findings suggest the consideration of human health risk assessment results for the IAQ standards.

A Study on the Characteristics of Indoor Air Quality in Elevator (엘리베이터 실내공기질의 특성 기초조사)

  • Park, Jeong-Ho;Choo, Yeon-Gyu;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.677-685
    • /
    • 2012
  • The elevator is needed healthy and comfortable indoor air quality (IAQ) for using many people, but we found nothing about IAQ studies of an elevator. In general, air in the elevator car is sucked from the elevator's hoistway straight into the car using a fan. The air sucked into the hoistway may be filled with dust, mold and bacteria. This study was performed to measure of characteristics of indoor air quality (PM10, falling bacteria, $CO_2$, Rn and HCHO) in elevator's hoistway, CAR and lobby of 8 sites (4 apartments and 4 commercial buildings) in Gyeongnam from May, 2010 to January, 2011. With regards to the differences of pollutant distribution among hoistway, CAR, and lobby, the concentration of Rn and HCHO were the highest in hoistway followed by CAR and lobby, and PM10, falling bacteria and $CO_2$ were the highest in CAR followed by hoistway and lobby. Mean concentrations of PM10 were 104.9 ${\mu}g/m^3$ in CAR, 92.3 ${\mu}g/m^3$ in hoistway and 68.2 ${\mu}g/m^3$ in lobby, respectively.

Experimental Study on the Effect of Ventilation System on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 강제환기장치 사용에 따른 실내공기질 개선효과 실증연구)

  • Lee, Gyu-Dong;Park, Young-Sok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.143-146
    • /
    • 2006
  • There has been growing concern regarding IAQ(Indoor Air Quality) recently, and IAQ problems from the air-tightness and use of chemical materials addition to the building materials have become increasingly important factors in the built environment. Ventilation is supposed as the solution of healthy indoor quality, and Korea government requests that all new apartment buildings must have a ventilation system as a matter of duty since January, 2006. The purpose of this study is to investigate the indoor concentration change of VOCs include the Formaldehyde according to many different ventilation supply types. Results showed that the reduction effect of target pollutants by the ventilation system was very slight. The cause of these results was attribute to increase the emission rate of building materials by increasing the ventilation rate.

  • PDF

The Study On the Distribution of Indoor Concentration of Microorganism in Commercial Building (다중이용시설의 실내공기 미생물 오염실태에 관한 연구)

  • Park Kyung-Su;Choi Sang-Gon;Hong Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.620-626
    • /
    • 2006
  • Recently, indoor air quality (IAQ) is one of the greatest problems in our modern societies. Although research for IAQ is made rapid progress but IAQ problems concerning in door microorganism contamination is required to be studied still more. So we have investigated the indoor microorganism concentration of a variety of department store, subway station, underground shopping center, kindergartens, library where people complain about the in-door air quality. The experiment on microorganism concentration of indoor air was carried out and the average of total microorganisms was measured. Comparing the experimental results with existing foreign criterion, the experimental results show that the ministry of environment recommendation microorganism concentration value ($800 CFU/m^3$) is in need of revision in the near future.

A Review of Scientific Evidence on Indoor Air of School Building: Pollutants, Sources, Health Effects and Management

  • Chithra, V.S;Shiva, Nagendra S.M
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.87-108
    • /
    • 2018
  • Schools are one of the critical social infrastructures in a society, the first place for social activity and the most important indoor environment for children besides the home. Poor IAQ in classrooms can increase the chance of long-term and short-term health problems for students and staffs; affects productivity of teachers; and degrade the student learning environment and comfort levels. The primary objective of this paper is to review and summarize available scientific evidence on indoor air quality of schools and related health effects in children. It was found that the indoor air pollutant levels in school buildings varied over a wide range in different parts of the world depending on site characteristics, climatic conditions, outdoor pollution levels, occupant activities, ventilation type and building practices. Among the indoor air pollutants, particulate matter concentrations were found to be very high in many schools. Outdoor pollutant sources also play a major role in affecting the IAQ of the school building. Hence, scientific knowledge on sources of indoor pollutants, quantification of emissions, temporal and spatial dispersion of pollutants, toxicological properties, chemical and morphological characteristics of the pollutants and associated health risk among children in the school buildings are essential to evaluate the adequacy and cost effectiveness of control strategies for mitigating the IAQ issues.

IAQ improvement effect analysis in Dynamic Breathing Building(DBB) (숨쉬는 벽체를 적용한 건물에서의 실내공기질(IAQ) 개선 효과 분석)

  • Park, Yong-Dai;Lee, Jin-Sook;Kang, Eun-Chul;Lee, Euy-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.748-753
    • /
    • 2008
  • In modern buildings, the air-tightness and insulation for energy saving resulted in degradation of Indoor Air Quality(IAQ). It has brought out new diseases such as New Building Syndrome(NBS) and Sick Building Syndrome(SBS) to the tenants of such buildings. As a result, researches on the Dynamic Breathing Building(DBB) are being undertaken to minimize energy loss as well as to improve IAQ. DBB is a state-of-the-art technology to build channels inside the wall so that air migrates between indoor and outdoor, which improves insulation performance and IAQ. This study attempts to evaluate the improvement of DBB employed in real buildings. As analyzing tools, IAQ improvement and particle degradation while were evaluated while the required indoor ventilation rate was satisfied. DBB were installed in the twin test cells at Korea Institute of Energy Research(KIER). From the test, IAQ was compared with outdoor air base on the concentration of particle matter(PM10). As a results, the concentration of particle dust (PM10) within the breathing walls was reduced by 80% at 0.7 ACH, 67% at 2 ACH, 63% at 3 ACH respectively. As ACH is higher, Dnamic Isulation(DI) and normal wall permit more PM10 particles being infiltrated.

  • PDF

A study on Development and Application of Sequential Control Algorithm of Ventilation and Air Cleaning System for Improving Indoor Air Quality in School Classroom (학교교실의 실내공기질 개선을 위한 환기장치 및 공기청정기의 연동제어 알고리즘 개발 및 적용 연구)

  • Park, Hwan-Chul;Lee, Dong-Hyeon;Yee, Jurng-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.187-194
    • /
    • 2020
  • This study presents the energy-saving sequential control algorithm to handle indoor CO2 and PM2.5 for the improvement of the air quality of school classrooms. To solve indoor air quality (IAQ) problems, air cleaning and ventilation systems are mainly used for school classrooms. Although air cleaning is able to collect PM2.5, it is difficult to remove harmful gas substances. The ventilation system is suitable to tackle CO and CO2, the volume ventilation, however, is relatively small. In this paper, to remove CO2 and PM2.5, the pollutant balance equation for improving indoor air quality is reviewed. The sequential control algorithm of the ventilation and air cleaning system with four levels of criteria is introduced for the effective removal of pollutants. The proposed sequential control algorithm confirms that indoor CO2 and PM2.5 can be properly controlled below the standard value. In addition, the sequential operation of air cleaning and ventilation systems has shown significant improvement in IAQ compared to the independent ventilation system operation. Particularly, such systems are efficient when outdoor PM2.5 is high.

A Study on Characteristics of Main Indoor Air Pollutants and Ventilation in Nursery Facilities (어린이집 실내공기 중 주요 오염물질의 특성 및 환기에 관한 연구)

  • Kim, Sang Cheol;Kang, Byeong-Chang;Lee, Sang-Uk;Kim, Gi-Doo;Seo, Won-Ho;Kim, Jong-Heon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.245-250
    • /
    • 2014
  • As the number of nursery facilities and infants who stay there is continuously increasing, IAQ (Indoor Air Quality) of nursery facilities should be managed strictly and thoroughly because infants are more susceptible to infections due to their low resistivity. In this study the characteristics of IAQ and ventilation associated factors were investigaed for suggesting a desirable condition for IAQ management. Environmental factors were not much related to IAQ characteristics rather than internal factors such as structures of the room. And the positive effect of ventilation on IAQ was obvious and seemed to hinge on factors related to window area especially window/wall ratio. Results of this study indicate that the structure with broader window area of a room and frequnet ventilation can be an effective way for keeping IAQ of nursery facilities clean and safe.

Critical Factor on Selection Indoor Air Quality improving alternatives for healthcare projects (병원의 실내 공기 질 솔루션 선택에 영향을 미치는 요인들)

  • Dang Nguyen-Hong Anh;Ahn, Yong-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.63-64
    • /
    • 2023
  • Indoor Air Quality is crucial in hospital projects to ensure the health and safety of patients, staff, and visitors. The research methodology comprises an comprehensive literature review, then a comprehensive questionnaire survey conducted among stakeholders involved in Vietnamese hospital projects. 15 variables were identified and categorized into four distinct groups, elucidating their influence on the adoption of advanced IAQ-enhancing technology. This study uses factor analysis, a mean score method and hypothesis test to analyze the factor result from the survey. two-step process, including an in-depth literature review and questionaire survey. The study's findings culminated in the ranking, examination, and categorization of these 15 variables, which were clustered into four essential categories: economic factors, design elements, governance strategies, and technical requirements. Additionally, the research explored viable solutions to improve indoor air quality in Vietnam's unique environmental context, examining the factors that impact the selection of such solutions. The study's outcomes yield practical recommendations for architects, engineers, and hospital administrators in enhancing IAQ within healthcare facilities. Furthermore, it presents a framework attuned to local environmental factors and building materials, contributing significantly to the existing body of knowledge on IAQ within hospital projects, particularly in the Vietnamese context.

  • PDF