• Title/Summary/Keyword: IAQ (indoor Air Quality)

Search Result 188, Processing Time 0.026 seconds

The Assessment of Survey on the Indoor Air Quality at Schools in Korea (국내 일부학교 건축물의 실내공기질 평가)

  • Sohn Jong-Ryeul;Roh Young-Man;Son Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

Box Model Approach for Indoor Air Quality (IAQ) Management in a Subway Station Environment

  • Song, Jihan;Pokhrel, Rajib;Lee, Heekwan;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.184-191
    • /
    • 2014
  • Air quality in a subway tunnel has been crucial in most of the subway environments where IAQ could be affected by many factors such as the number of passengers, the amount and types of ventilation, train operation factors and other facilities. A modeling approach has been introduced to manage the general IAQ in a subway station. Field surveys and $CO_2$ measurements were initially conducted to analyze and understand the relationship between indoor and outdoor air quality while considering internal pollution sources, such as passengers and subway trains, etc. The measurement data were then employed for the model development with other statistical information. For the model development, the algorithm of simple continuity was set up and applied to model the subway IAQ concerned, while considering the major air transport through staircases and tunnels. Monitored $CO_2$ concentration on the concourse and platform were correlated with modeling results where the correlation values for the concourse and platform were $R^2=0.96$ and $R^2=0.75$, respectively. It implies that the box modeling approach introduced in this study would be beneficial to predict and control the indoor air quality in subway environments.

Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads (시스템에어컨과 환기시스템 설치 강의실에서 냉방시 열쾌적성 및 실내공기질 연구)

  • Noh Kwang-Chul;Jang Jae-Soo;Oh Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.57-66
    • /
    • 2006
  • The experimental and the numerical study was performed on the comparison of thermal comfort(TC) and indoor air quality(IAQ) in the lecture room for cooling loads when the operating conditions are changed. PMV value and $CO_2$ concentration of the lecture room were measured and compared with the numerical results. The numerical results showed a good agreement with the experimental one and then the numerical tool was used to analyze thermal comfort and IAQ for a couple of operating conditions. As a result it was found that the increment of the discharge angle of system air-conditioner makes TC uniformity worse, but rarely affects IAQ. Also TC and IAQ were hardly affected by the variation of the discharge airflow. Finally it turned out that TC is merely affected by the increment of the ventilation airflow, but the average $CO_2$ concentration can be satisfied with Japanese IAQ standards of classrooms when the ventilation airflow is more than $800m^3/h$ in this study.

Development of an IAQ Index for Indoor Garden Based IoT Applications for Residents' Health Management (실내거주자 건강 관리를 위한 IoT기반 실내정원용 IAQ지수 개발)

  • Lee, Jeong-Hun;An, Sun-Min;Kwak, Min-Jung;Kim, Kwang Jin;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.421-432
    • /
    • 2018
  • Objectives: In this study, we started to develop an indoor garden integrated IoT solution based on IAQ (indoor air quality) and interconnection with an environmental database for smart management of indoor gardens. The purpose of this study was to develop and apply an integrated solution for customized air purification from an indoor garden through big data analysis using IoT technology. Methods: An IoT-based IAQ monitoring system was established in three households within a new apartment building. Based on real-time and long-term data collected, $PM_{2.5}$, $CO_2$, temperature, and humidity changes were compared to those of indoor garden applications and the analyzed results were indexed. Results As a result of the installation, all three households had no results exceeding the standard for indoor air pollution on average $PM_{2.5}$ and $CO_2$ indices. In the case of indoor garden installation, the IAQ index increased to the "Good" section after the installation, and readings in the "Bad" section shown before the installation disappeared. The comfort index also did not dip into the "Uncomfortable" section, where it had been preinstallation, and significantly lowered the average score from "Uncomfortable for sensitive groups" to "Good". Overall, the IAQ composite index for the generation of installations decreased the "Good" interval, but "Bad" did not appear. Conclusions In this study on developing an integrated solution for IAQ based on IoT indoor gardens, big data was analyzed to determine IAQ and comfort indexes and an IAQ composite index. Through this process, it became understood that it is necessary to monitor IAQ based on IoT.

A Finish Material Management Process for Indoor Air Quality -Focused on Apartment Buildings- (실내 공기질을 고려한 마감자재 선정 프로세스 연구 -공동주택을 중심으로-)

  • Kwon, Gi-Deoc;Lee, Dong-Hoon;Lee, Sung-Ho;Zheng, Qi;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.123-130
    • /
    • 2010
  • Indoor air quality has attracted great attention in recent years and thus the importance of managing finishing materials in terms of pollutant source control is being emphasized. Managing the finishing material at the design stage maximizes the efficiency of IAQ control at the following construction stage. However, there are insufficient investigations on the application of a specific finishing material management process, a database management system or a finishing material management process network. As a result, the main purposes of this study comprise comprehensive evaluation of IAQ performance from the selected finishing materials and auxiliary materials, application of the material management system basing on the types and characteristics of toxic substances generated from the indoor finishing materials, investigation of IAQ evaluation standard, and the overall IAQ evaluation method for the design parts. The result of this study will be the basic data to construct DBMS for management of finishing materials with respect to IAQ.

Assessment of Conscious Coginition Degree and Survey on Oxyen Generators using the Indoor Environment (실내환경중의 산소발생기 사용에 대한 인식도 평가)

  • 손종렬;조윤수;이규현;황상용
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.4
    • /
    • pp.64-69
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and office has been concern of people, scientists and related the public. The oxygen in air was very important and essential element in every aspect of life. This study was performed on a questionnaire survey of 400 people about their awareness of indoor air quality, oxygen generators and measured of oxygen concentration in indoor environment. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 80% of them can feel indoor air pollutions degrees directly by particle matters. The control of most important problems of IAQ was the poor ventilation. We know that 22% of the respondents was recognized the oxgen generator. And for the installation of indoor pollution control equipment, 20% of all respondents installed oxygen generators because almost respondents was not satified the trust of ability purified indoor air pollutants. In the experimental results, it was found that the oxygen concentration of sampling sites were in the range of 20~23.5%. Therefore, it was recommended that the government related IAQ was suggested the guideline and control of oxygen generators. Finally, it appeared that the oxygen generators using indoor environment can be applied to new technology for cleaning of indoor air.

Assessment of Indoor Air Quality(IAQ), Comfort and Safety in Metro Subway Station

  • Choi, Gi-Heung
    • International Journal of Safety
    • /
    • v.7 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • With ever increasing number of citizen using subway stations everyday, safety, health and comfort of passengers and occupants (mostly metro personnel) have become important social issues. Considering the fact that various physical variables and pollutants such as particulate, VOCs and biological agents are closely related to indoor air quality (IAQ) which may cause health problems, a method of quantitative assessment using information-theoretic measure on such variables needs to be devised and implemented for comfort, health and safety of passengers and occupants in the subway station. A basic framework for assessing indoor air quality (for comfort and health) and safety in subway station is suggested. In particular, application of information-theoretic measure for the assessment of indoor air quality, comfort and safety in subway station is discussed. Some examples are presented as well.

Architectural Implementation of the Indoor Air Quality in the Elementary School Classroom (학교건물의 실내공기환경 개선방안에 관한 건축계획적 연구)

  • Koo, Jae-Oh;Bae, Sun-Chul;Kim, Gon
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.15-22
    • /
    • 2007
  • Indoor air quality(IAQ) problems are not limited to large office buildings that are inadequately operated. In fact, many school buildings have significant potentials of air pollution and indoor air pollutants may be of particular concern because it is estimated that most young students who are physically weak to the pollutants spend about 90% of their time in classrooms. The goal of the study is to provide academic and architectural information on the major factors that influence indoor air quality in the elementary school. In order to gain a better understanding of IAQ problems in schools, a series of measurement studies of indoor air quality were designed and 3 different elementary school buildings located in Chuncheon were selected. The levels of CO, $CO_2$, and total volatile organic compounds(TVOCs) including formaldehyde(HCHO), major concern of this study, were measured in absence of students after class. As the results, it is noticeable that most indoor air pollution comes from sources inside the building, which are, for example, adhesives, upholstery, manufactured wood products, art and scientific supplies. The level of CO was measured similarly to that of outdoors, which means no impact on the indoor air problems since it is lower than the code. Ventilation played an important role in the level of $CO_2$ of which difference was 1.7 times in rough and 230 % of difference in the level was detected among the 3 school buildings. This concludes that indoor air problems might be result of poor building design with inadequate location of corridors within space organization or occupant activity patterns of ventilation.

The Assessment and Characteristics for Indoor Air Quality in Military Barracks (군 병영시설의 실내 공기질 평가 및 특성)

  • Kim, Suk-Bong;Jeong, Sang-Jo;Baek, Sang-Ho;Kim, Tae-Wook;Park, Young-Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.168-175
    • /
    • 2007
  • In this study, the Indoor Air Quality(IAQ) in military barracks is evaluated and its characteristics is discussed as well. The military barracks of R.O.K Army are categorized into three types and the IAQ in these individual facilities is measured for 24 hours both in summer and winter. Test results show that the particulate matters($PM_{10}$) and carbon dioxide($CO_2$) were the main causes contaminating IAQ in military barracks. While $CO_2$ can be purified by ventilation, adequate facilities have to be installed in case of the new type of combination barracks to remove $PM_{10}$. In addition, to improve the living condition of military barracks and to recover IAQ in new combination style barracks which is planned to complete by 2011, a standard or law regulating IAQ in military barracks has to be established.

The Study On tile Distribution of Indoor Concentration of Microorganism in Commercial Building (다중이용 시설의 실내공기 미생물 오염실태에 관한 연구)

  • Choi, Sang-Gon;Hong, Jin-Kwan;Park, Kyung-Su
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.15-20
    • /
    • 2005
  • Recently, IAQ(indoor air quality) is one of the greatest problems in our modern societies. Although research for IAQ is made rapid progress but microorganism concentration is much to be desired. So we have examined a variety of department store, subway station, underground shopping center, kindergartens, library etc. where people complain about the indoor air quality. The microorganism concentration of indoor air was investigated in this study and the average of total microorganisms was measured. The experimental results show that the ministry of Environment recommendation value (800 $CFU/m^3$)is in need of revision in the naer future.

  • PDF