• Title/Summary/Keyword: I-P Curve

Search Result 303, Processing Time 0.027 seconds

A Study on Optimum Design for Railway Alignment in Curve (곡선부 최적 선형 설계기법에 관한 연구)

  • Um, Ju-Hwan;Yang, Sin-Chu;Kim, Eun-Kyum
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.4
    • /
    • pp.597-603
    • /
    • 2009
  • In this study, Based on the optimization developed in Um et al. (2009), optimum design method of the alignment when building new lines and renewing existing ones is presented. The object function used for optimization is passenger comfort ($P_{CT}$) which was proposed in BSI (2006). Other aspects of track/vehicle interaction will be treated in boundary conditions. And track/vehicle interaction analysis is peformed using KTX-II model. From the analysis results, it was found that the optimum alignments are affected by the angle (I) between adjacent straight lines and $R-L_t$ combinations. Also the dynamic analysis confirms well the results from the simplified analysis. However, In the most cases, the $P_{CT}$ values in the dynamic analysis are higher than the simplified $P_{CT}$ values. If both methods are used when optimizing the alignment, it will be possible to design the alignments more rapidly and reliably.

Comparison of Fatigue Strength Criteria for TiNi/Al6061-T6 and TiNi/Al2024-T4 Shape Memory Alloy Composite (TiNi/Al6061-T6과 TiNi/Al2024-T4 형상기억복합재료에 대한 피로강도기준의 비교)

  • Jo, Young-Jik;Park, Young-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.2
    • /
    • pp.99-107
    • /
    • 2009
  • This study produced a design curve and fatigue limit for a variation in volume ratio and reduction ratio of TiNi/Al composites. In many cases, stress-life curve does not indicate fatigue limit, so it was presented by probabilistic-stress-life curve. Goodman diagram was used to analyze the fatigue strength of materials with a finite life determined by repeated load and the fatigue strength of endurance limit with an infinite life. The fatigue experiment was conducted using the scenk-type plane bending specimen in same shape. The result of the fatigue test, which had been conducted under consistent stress amplitude, was examined. (i) The optimal condition for TiNi/Al in accordance with hot pressing (ii) Impacts of fatigue limit caused by a variation in reduction ratio and volume ratio of TiNi/Al composites (iii) Probability distribution for fatigue limit of TiNi/Al2024 and TiNi/Al6061.

Maximum Power Point Tracking Method Without Input side Voltage and current Sensor of DC-DC Converter for Thermoelectric Generation (열전발전을 위한 DC-DC Converter의 입력측 전압·전류 센서없는 최대전력점 추적방식)

  • Kim, Tae-Kyung;Park, Dae-Su;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.569-575
    • /
    • 2020
  • Recently, research on renewable energy technologies has come into the spotlight due to rising concerns over the depletion of fossil fuels and greenhouse gas emissions. Demand for portable electronic and wearable devices is increasing, and electronic devices are becoming smaller. Energy harvesting is a technology for overcoming limitations such as battery size and usage time. In this paper, the V-I characteristic curve and internal resistance of thermal electric devices were analyzed, and MPPT control methods were compared. The Perturbation and Observation (P&O) control method is economically inefficient because two sensors are required to measure the voltage and current of a Thermoelectric Generator(TEG). Therefore, this paper proposes a new MPPT control method that tracks MPP using only one sensor for the regulation of the output voltage. The proposed MPPT control method uses the relationship between the output voltage of the load and the duty ratio. Control is done by periodically sampling the output voltage of the DC-DC converter to increase or decrease the duty ratio to find the optimal duty ratio and maintain the MPP. A DC-DC converter was designed using a cascaded boost-buck converter, which has a two-switch topology. The proposed MPPT control method was verified by simulations using PSIM, and the results show that a voltage, current, and power of V=4.2 V, I=2.5 A, and P=10.5 W were obtained at the MPP from the V-I characteristic curve of the TEG.

Measurement of Phosphorus Buffering Power in Various Soils using Desorption Isotherm (탈착 등온식을 이용한 토양 중 인산 완충력 측정)

  • Lee, Jin-Ho;Doolittle, James J.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.4
    • /
    • pp.220-227
    • /
    • 2004
  • Phosphorus desorption study is essential to understanding P behavior in agricultural and environmental soils because phosphorus is considered as two different aspects, a plant nutrient versus an environmental contaminant. This study was conducted to determine soil P buffering power related to P desorption quantity intensity (Q/I) parameters, $Q_{max}$(an index of P release capacity) and $l_0$(an index of the intensity factor), and to investigate the characteristics of relationship between the P desorption Q/I parameters and the soil properties. Soil samples were prepared with treatments of 0 and $100mg\;P\;kg^{-1}$ applied as $KH_2PO_4$ solution. The P desorption Q/I curves were obtained by a procedure using anion exchange resin beads and described by an empirical equation ($Q=aI^{-1}+bln(I+1)+c$). The P desorption Q/I curves for the high available P (${\g}20mg\;kg^{-1}$ of Olsen P) soils were characteristic concave trends with or without soil P enrichment, whereas for the low available P (${\lt}20mg\;kg^{-1}$ of Olsen P) soils, the anticipated Q/I concave curves could not be obtained without a proper amount of P addition. When the soils were enriched in phosphates, the values of desorbed solid phase labile P and solution P, such as $Q_{max}$ and $I_0$ respectively, were increased, but the ratio of $Q_{max}$ versus $I_0$ was decreased. Thus, the slope of desorption Q/I curve represented as phosphorus buffering power, $|BP_0|$, is decreased. The $|BP_0|$ values of the high available P soils ranged between 48 and $61L\;kg^{-1}$ in the P untreated samples and between 18 and $44L\;kg^{-1}$ in the P enriched samples. Overall $|BP_0|$ values of both low and high available P soils treated with $l00mg\;P\;kg^{-1}$ ranged between 14 and $79L\;kg^{-1}$. The $Q_{max}$, values ranged between 71.4 and $173.1mg\;P\;kg^{-1}$, and the lo values ranged between 0.98 and $3.82mg\;P\;L^{-1}$ in the P enriched soils. The $Q_{max}$ and $I_0$ values that control the P buffering power may be not specifically related to a specific soil property, but those values were complicatedly related to soil pH, clay content, soil organic matter content, and lime. Also, phosphorus release activity, however, markedly depended on the desorbability of the applied P as well as the native labile P.

Carrier Lfetime and Anormal Cnduction Penomena in Silicon Epitaxial Layer-substrate Junction (Epitaxial에 의한 Si epi층의 케리어 수명과 P-N접합의 이상전도현상)

  • 성영권;민남기;김승배
    • 전기의세계
    • /
    • v.26 no.5
    • /
    • pp.83-89
    • /
    • 1977
  • This paper described the minority carrier lifetime in Si epitaxial layer, and also the voltage (V) versus current (I) characteristics of high resistivity Si epitaxial layer0substrate junction. The measured lifetime in Si epi-layer was much shorter than in bulk, and the temperature dependence of lifetime was found to agree well with Shockley-Read model of recombination which applies to high resistivity n-type materials. The V-I curve showed; an ohmic region (I.var.V), a sublinear region (I.var.V$^{1}$2/), a space charge limited current region (I.var.V$^{2}$), and finally a negative resistance region. We investigated these phenomena by the theory of the relaxation semiconductor.

  • PDF

Analytical Study on the Fire Resistance of SC Composite Column (SC 합성기둥의 내화성능에 대한 해석연구)

  • Lim, Yoon Hee;Kang, Seong Deok;Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.335-344
    • /
    • 2007
  • The steel-concrete composite column (i.e., the SC composite column) supports large-gravity loads and simplifies the installation and removal of the work in pouring the concrete. The column takes advantage of the in-plant prefabrication of steel, the speed of erection of a steel structure, and the fire resistance of steel. This paper presents the results of a parametric study using heat transfer analysis and a P-M interaction curve, and compares these results with the experimental results to check the accuracy of the proposed parametric studies. The parametric studies, such as the study of the concrete ratio of an area and the fire protection thickness, provide information on the fire resistance of SC composite columns.

Resistance of Cementitious Binders against a Fall in the pH at Corrosion Initiation

  • Song, Ha-Won;Jung, Min-Sun;Ann, Ki Yong;Lee, Chang-Hong
    • Corrosion Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.110-115
    • /
    • 2009
  • At the onset of corrosion of steel in concrete, hydrogen ions usually evolve in the process of electrochemical reaction, thereby decreasing the pH of the pore solution, which can be buffered by cement hydration products, as being representatively illustrated by calcium hydroxide. Hence, a fall in the pH is dependent on properties of cement hydration (i.e. hydration products and degree of hydration). The present study tested acid neutralization capacity (ANC) of cementitious binders of OPC(Ordinary Portland Cement), 30% PFA(Pulverized Fuel Ash), 60% GGBS(Ground Granulated Blast Furnace Slag), 10% SF(Silica Fume) to quantify the resistance of cement matrix to a pH fall. Cement pastes were cast at 0.4 of a free W/C ratio with 1.5% chlorides by weight of binder in cast. Powder samples obtained crushed and ground specimen after 200 days of curing were diluted in still water combined with different levels of 1M nitric acid solution, ranging from 0.5 to 20 mol/kg. Then, the pH of diluted solution was monitored until any further change in the pH did not take place. It was seen that the pH of the diluted solution gradually decreased as the molar amount of nitric acid increased. At some particular values of the pH, however, a decrease in the pH was marginal, which can be expressed in the peak resistances to a pH fall in the ANC curve. The peaks occurred at the variations in the pH, depending on binder type, but commonly at about 12.5 in the pH, indicate a resistance of precipitated calcium hydroxide. The measurement of water soluble chloride at the end of test showed that the amount of free chloride was significantly increased at the pH corresponding to the peaks in the ANC curve, which may reflect the adsorption of hydration products to chlorides.

Automatic P/PI Speed Controller Design for Industry Servo Drives (산업용 서보 구동 시스템을 위한 자동 P/PI 속도 제어기 설계)

  • 배상규;석줄기;김경태;이동춘
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.616-623
    • /
    • 2003
  • Conventional P/PI speed controller of today's servo drives should be manually tuned the controller switching set-point by trial-and-errors, which may translate the drive system down-time and loss of productivity. The adjustable drive performance is heavily dependent on the quality of the expert knowledge and becomes inadequate in applications where the operating conditions change in a wide range, i.e., tracking command, acceleration/deceleration time, and load disturbances. In this paper, the demands on simple controls/setup are discussed for industry servo drives. Analyzing the frequency content of motor torque command, P/PI control mode switching is automatically performed with some prior knowledge of the mechanical dynamics. The dynamic performance of the proposed scheme assures a desired tracking response curve with minimal oscillation and settling time over the whole operating conditions. For comprehensive comparison of traditional P/PI control scheme, extensive test is carried out on actual servo system.

Establishment of a Tm-shift Method for Detection of Cat-Derived Hookworms

  • Fu, Yeqi;Liu, Yunqiu;Abuzeid, Asmaa M.I.;Huang, Yue;Zhou, Xue;He, Long;Zhao, Qi;Li, Xiu;Liu, Jumei;Ran, Rongkun;Li, Guoqing
    • Parasites, Hosts and Diseases
    • /
    • v.57 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • Melting temperature shift ($T_m-shift$) is a new detection method that analyze the melting curve on real-time PCR thermocycler using SYBR Green I fluorescent dye. To establish a $T_m-shift$ method for the detection of Ancylostoma ceylanicum and A. tubaeforme in cats, specific primers, with GC tail of unequal length attached to their 5' end, were designed based on 2 SNP loci (ITS101 and ITS296) of the internal transcribed spacer 1 (ITS1) sequences. The standard curve of $T_m-shift$ was established using the standard plasmids of A. ceylanicum (AceP) and A. tubaeforme (AtuP). The $T_m-shift$ method stability, sensitivity, and accuracy were tested with reference to the standard curve, and clinical fecal samples were also examined. The results demonstrated that the 2 sets of primers based on the 2 SNPs could accurately distinguish between A. ceylanicum and A. tubaeforme. The coefficient of variation (CV) of $T_m$- values of AceP and AtuP was 0.07% and 0.06% in ITS101 and was 0.06% and 0.08% in ITS296, respectively. The minimum detectable DNA concentration was $5.22{\times}10^{-6}$ and $5.28{\times}10^{-6}ng/{\mu}l$ samples of AceP and AtuP, respectively. The accuracy of $T_m-shift$ method reached 100% based on examination of 10 hookworm DNA samples with known species. In the clinical detection of hookworm in 69 stray cat fecal sample, the $T_m-shift$ detection results were consistent with the microscopic examination and successfully differentiated between the 2-hookworm species. In conclusion, the developed method is a rapid, sensitive and accurate technique and can provide a promising tool for clinical detection and epidemiological investigation of cat-derived hookworms.

Fabrication and Characteristics of the Controlled Inversion Devices (제어 반전 소자의 제조 및 그 특성)

  • 김진섭;이우일
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.1
    • /
    • pp.45-49
    • /
    • 1983
  • The four-layered(metal/insulator/n epi-layer/p+) controlled inversion devices have been fabricated. The I-V curve showed two characteristic states―an On state and an OFF state which were separated by a negative resistance region. The switching voltage and the holding voltage were about 5.0V and 2.5V, respectively. The switching voltage of the device was decreased by photo illumination while the holding voltage remained unaffected.

  • PDF