• Title/Summary/Keyword: I-131 whole body scan

Search Result 24, Processing Time 0.038 seconds

Optimal Imaging Time for Diagnostic I-123 Whole Body Scan in the Follow-up of Patients with Differentiated Thyroid Cancer: Comparison between 6- and 24-Hour Images of the Same Subjects (분화 갑상선 암의 추적 관찰에서 진단적 I-123 전신 스캔의 최적 영상 시점: 동일 환자에서 6시간과 24시간 영상의 비교)

  • Lee, Hong-Je;Lee, Sang-Woo;Song, Bong-Il;Kang, Sung-Min;Seo, Ji-Hyoung;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.129-136
    • /
    • 2009
  • Purpose: To determine optimal imaging time for diagnostic I-123 whole body scan in the follow-up of patients with differentiated thyroid cancer(DTC), we compared the image quality of 6- and 24-hour images of the same subjects. Materials and Methods: Four hundred ninety-eight patients(M:F = 55:443, Age $47.6{\pm}12.9$ years) with DTC who had undergone total thyroidectomy and I-131 ablation therapy underwent diagnostic whole body scanning 6 hour and 24 hour after oral ingestion of 185 MBq(5 mCi) of I-123. Serum thyroglobulin measurement and ultrasonography of the neck were performed at the time of imaging. In 40 patients underwent additional I-131 therapy, post-therapy I-131 images were obtained and compared with diagnostic I-123 images. Results: In 440 patients(88.4%), 6- and 24-hour diagnostic I-123 images were concordant, and 58 patients(11.6%) showed discordant findings. Among 58 discordant patients, 31 patients showed abnormal tracer uptake on only 6-hour image, which turned out false-positive findings in all cases. In 12 patients with positive findings on only 24-hour image, remnant thyroid tissue(4 patients) and cervical lymph node metastasis(3 patients) were presented. Among 40 patients underwent additional I-131 therapy, 6-hour and 24-hour images were discordant in 13 patients. All 5 patients with abnormal uptake on only 6-hour image revealed false-positive results, whereas most of 24-hour images were concordant with post-therapy I-131 images. Conclusion: I-123 imaging at 24-hour could reduce false-positive findings and improve diagnostic accuracy, compared with 6-hour image in the follow-up of patient with DTC.

Radioiodine Therapy in a Patient with Papillary Thyroid Carcinoma associated with Breast Uptake; Hyperprolactinemia due to Empty Sella Syndrome (유즙분비가 있는 갑상선암 환자에서 I-131 치료)

  • Pai, Moonsun;Park, Chan H.;Suh, Jung-Ho;Kim, Kyung-Rae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.109-113
    • /
    • 1998
  • We report a 37 year-old-female patient with papillary thyroid cancer treated by surgery who demonstrated residual thyroid and bilateral breast uptake on a diagnostic I-131 whole body scan. She had an extrathyroidal extension needing I-131 ablative therapy. Her galactorrhea was investigated and treated with low doses of bromocriptine prior to I-131 therapy. Her galactorrhea was due to the decreased secretion of PIF induced by empty sella.

  • PDF

The Analysis of radioactivity Concentration in drainage when using a radioactive Iodine (방사성옥소 사용 시 배수 중 방사능농도 분석)

  • Lee, Kyung-Jae;Sul, Jin-Hyung;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • Purpose With regard to the use of radioiodine in domestic medical institution, the case of exceeding the allowance of nuclear safety Act about radioactive concentration in drainage was found. Through understanding the cause of exceeding case and analyzing radioactive concentration in drainage, evaluating the relationship of the public waters in surroundings and usefulness. Materials and Methods From November 1, 2014 to April 30th, 2015, the research is aiming at domestic twenty hospitals for six months. By using a HPGe gamma-ray spectrometer(Canberra DSA-1000) and GENIE-2000 Analysis software for comparative analysis, measuring a radioactive concentration of radioiodine in drainage. Consequently, we confirm the excess of radioactive concentration of radioiodine in seven medical institutions. Results Conducting a survey of twenty hospitals and average radioactive concentration of radioiodine in drainage appears $42,100Bq/m^3$. The features of domestic hospitals where show a high radioactive concentration are a number of medical treatment patient when using radioactive iodine and the absence of private rest room. During I-131 whole body scan, the pretreatment procedure of urinating is considered emission of residual Iodine. In public waters, the cause of exceeding detect on radioactive concentration in drainage suppose a diagnostic radioactive iodine. Conclusion We confirm the importance of enhanced education, providing a safety control instructions and installing a private rest rooms for patients who injected a low capacity radioiodine. Also, constructing institutional and legal management system is considered about the Emission management standard in drainage.

Low-dose Radioactive I-131 Therapy after Total Thyroidectomy for Differentiated Thyroid Cancer (갑상선 분화암 수술 후 저용량 방사성 옥소(I-131)요법)

  • Choi Chung-Jin;Jung Sung-Hoo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.214-219
    • /
    • 1998
  • Objectives: To assess the effectiveness of the low-dose(30mCi) I-131 ablation therapy for remnant thyroid tissue following total thyroidectomy for differentiated thyroid cancer. Methods: Between March 1995 and December 1997, forty-eight patients were given ablative doses(30mCi) of I-131 after total thyroidectomy for differentiated thyroid cancer in the presence of I-131 uptake in remnant thyroid tissue. Effective ablation of remnant thyroid tissue was determined by following I-131 whole body scan. if remnant thyroid tissue remained, we repeated the same management at 6 months interval. Results: Thirty-eight(79.1%) patients had papillary, 8(16.7%) follicular, 1(2.1%) medullary and 1(2.1%) Hurthle cell type cancer. Forty-eight patients underwent total thyroidectomy, among those central neck dissection was performed in 35 cases, and modified radical neck dissection in 14 cases. Postoperative complication developed in 8 cases, which included 4 cases of transient hypoparathyroidism, 1 case of permanent hypoparathyroidism, 2 cases of transient recurrent laryngeal nerve palsy, and 1 case of wound hematoma. There were significant remnant thyroid tissue in 46 cases(95.8%) of patients after total thyroidectomy, which could be ablated by low dose(30mCi) I-131. There were no statistical difference between operative procedures and number of treatment of I-131. Conclusions: These results suggested that repeated low-dose(30mCi) I-131 therapy would be needed, therefore, high -dose I-131 therapy could be considered as ablation therapy for the remnant thyroid tissue after total thyroidectomy for differentiated thyroid cancer.

  • PDF

The Accuracy of the Table Movement During a Whole Body Scan (전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구)

  • Lee, Ju-Young;Jung, Woo-Young;Jung, Eun-Mi;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.86-91
    • /
    • 2009
  • Purpose: The whole body scan in Nuclear Medicine is a widely accepted examination and procedure. Especially, it is mainly used in bone, I-131, MIBI, and HMPAO WBC scans. The diverse uses of the whole body scan range from the HMPAO WBC scan with a speed of 13cm/min, to a whole body bone scan using the Onco. Flash technique with a speed of 30cm/min. The accuracy of table movement has a strong correlation with the image quality, and inaccuracy of speed could negatively affect the image quality. The purpose of this study is to evaluate the accuracy of the table movement while considering the influence of the age of the equipment and the variability in the weight of the patients. Material and Methods: The study was conducted using two of Seoul Asan Medical Center's SIEMENS gamma cameras which are commonly used in our whole body study. The first one is the oldest gamma camera, an ECAM plus (installed in 2000), and the last is brand new one, a SYMBIA T2 (installed in 2008). Three trials were conducted with the tables moving at a different speed each time; 10, 15 and 30 cm/min. The tables' speeds were measured by checking how long it took for the table to move 10cm, and this was repeated every 10cm until the table reached 100 cm. With an average body weight of the patients of about 60~70 kg, the table speed was measured with weights of 0 kg, 66 kg and 110 kg placed on the table, then compared among conditions. Results: The coefficient of variance (CV) of the ECAM plus showed 1.23, 1.42, 2.02 respectively when the table movement speeds were set at 10, 15, and 30 centimeters per minute. Under the same conditions, the SYMBIA T2 showed 1.23, 1.83 and 2.28 respectively. As table movement speed more, the variance of CV as the speed increases. When the patient body weight was set to 0, 66 and 110kg, the CV values of both cameras showed 0.96, 1.45, 2.08 (0 Kg), 1.32, 1.72, 2.27 (66 Kg) and 1.37, 1.73, 2.14 (110 Kg). There was no significant difference (p>0.05) in 95 percent of confidence intervals and measured CV values were acceptable. However, the CV value of the SYMBIA T2 was relatively larger than the ECAM plus. Conclusion: The scan speed of the whole body scan is predetermined based on which examination is being performed. It is possible for the accuracy of the speed to be affected, such as the age of the equipment, the state of the bearings or the weight of a patient. These factors can have a negative impact on the diagnostic consistency and the image quality. Therefore, periodic quality control should be needed on the gamma cameras currently being used, focusing on the table movement speed in order to maintain accuracy and reproducibility.

  • PDF

Lung Metastasis of Thyroid Papillary Carcinoma which was Temporarily Treated for Milliary Tuberculosis (파종성 폐결핵으로 오인된 갑상선 유두상암종의 폐전이)

  • Na, Hong-Shik;Lee, Je-Hyuck;Paeng, Jae-Pil;Jung, Kwang-Yoon;Choi, Jong-Ouck
    • Korean Journal of Bronchoesophagology
    • /
    • v.6 no.1
    • /
    • pp.16-20
    • /
    • 2000
  • The patient a 24-year-old male, was shown to have milliary shadows on chest radiographs from the age of 20. He was temporarily treated for pulmonary tuberculosis without success. He had left thyroid mass and lymph node metastases in neck CT scan which was taken after admission but fine needle aspiration result in scanty cellularity. He underwent total thyroidectomy with left modified radical neck dissection and right selective neck dissection under the impression of differentiated thyroid cancer with bilateral neck metastases. Then he underwent 131I ablation treatment and postoperative whole body 131I scintigraphy revealed diffuse intensive uptake in the bilateral lung fields, demonstrating that the pulmonary lesions were metastases of the thyroid cancer.

  • PDF

Comparison of Diagnostic and Post-therapy Radioiodine Scan in Well-Differentiated Thyroid Cancer and the Clinical Outcome (갑상선암 환자에서 방사성옥소 진단스캔과 치료 후 스캔의 비교 및 임상경과)

  • Lee, Seok-Mo;Bae, Sang-Kyun;Yum, Ha-Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose: We compared the first postoperative diagnostic and post-therapy scans of patients who received therapeutic doses of I-131, to investigate the difference in clinical outcomes between patients with concordant findings of diagnostic and post-therapy scans and patients with discrepant (more lesions in post-therapy scan) findings. Materials and Methods: The first postoperative diagnostic and post-therapy radioiodine scans of one hundred forty three patients with well differentiated thyroid carcinoma were reviewed. Diagnostic scans were obtained following ingestion of 185 MBq of I-131 and post-therapy scans were obtained after therapeutic dose of $3.7{\sim}9.3$ GBq of I-131. Successful ablation was defined as no radioiodine uptake on diagnostic radioiodine scan and normal range of serum thyroglobulin level (<10 ng/ml) during serum TSH elevation. Results: Discrepant scan findings were noted in 25 (17.5%) patients. Twenty-two patients (15.4%) showed more lesions in post-therapy scan and 3 patients (2.1%) showed stunning effect. Nine (64.3%) of 14 patients with distant metastasis revealed metastatic lesion(s) only on post-therapy scan. Stunning effect was considered as sublethal damage in 1 patient and treatment by a diagnostic dose in 2 patients. Ablation was achieved in 52.4% (75/143) of all patients. Ablation rate and mean cumulative radioiodine dose were not different statistically between concordant and discrepant groups. Conclusion: There were 17.5% difference between diagnostic and post-therapy scan findings when using 185 MBq of I-131 as a diagnostic dose. However, 64.3% of distant metastases were revealed only on post-therapy scan. Ablation rate and mean cumulative radioiodine dose were not different statistically between concordant and discrepant groups. The stunning effect was considered as not only sublethal damage but also treatment by a small diagnostic dose of radioiodine.

  • PDF

Determination of Therapeutic Dose of I-131 for First High Dose Radioiodine Therapy in Patients with Differentiated Thyroid Cancer: Comparison of Usefulness between Pathological Staging, Serum Thyroglobulin Level and Finding of I-123 Whole Body Scan (분화 갑상선암 수술 후 최초 고용량 방사성옥소 치료시 투여용량 결정: 병리적 병기, 혈청 갑상선글로불린치와 I-123 전신 스캔의 유용성 비교)

  • Jeong, Hwan-Jeong;Lim, Seok-Tae;Youn, Hyun-Jo;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.301-306
    • /
    • 2008
  • Purpose: Recently, a number of patients needed total thyroidectomy and high dose radioiodine therapy (HD-RAI) get increased more. The aim of this study is to evaluate whether pathological staging (PS) and serum thyroglobulin (sTG) level could replace the diagnostic I-123 scan for the determination of therapeutic dose of HD-RAI in patients with differentiated thyroid cancer. Materials and Methods: Fifty eight patients (M:F=13;45, age $44.5{\pm}11.5\;yrs$) who underwent total thyroidectomy and central or regional lymph node dissection due to differentiated thyroid cancer were enrolled. Diagnostic scan of I-123 and sTG assay were also performed on off state of thyroid hormone. The therapeutic doses of I-131 (TD) were determined by the extent of uptakes on diagnostic I-123 scan as a gold standard. PS was graded by the criteria recommended in 6th edition of AJCC cancer staging manual except consideration of age. For comparison of the determination of therapeutic doses, PS and sTG were compared with the results of I-123 scan. Results: All patients were underwent HD-RAI. Among them, five patients (8.6%) were treated with 100 mCi of I-131, fourty three (74.1%) with 150 mCi, six (10.3%) with 180 mCi, three (5.2%) with 200 mCi, and one (1.7%) with 250 mCi, respectively. On the assessment of PS, average TDs were $154{\pm}25\;mCi$ in stage I (n=9), $175{\pm}50\;mCi$ in stage II (n=4), $149{\pm}21\;mCi$ in stage III (n=38), and $161{\pm}20\;mCi$ in stage IV (n=7). The statistical significance was not shown between PS and TD (p=0.169). Among fifty two patients who had available sTG, 25 patients (48.1%) having below 2 ng/mL of sTG were treated with $149{\pm}26\;mCi$ of I-131, 9 patients (17.3%) having $2{\leq}\;sTG\;<5\;ng/mL$ with $156{\pm}17\;mCi$, 5 patients (9.6%) having $5{\leq}\;sTG\;<10\;ng/mL$ with $156{\pm}13\;mCi$, 7 patients (13.5%) having $10{\leq}sTG\;<50\;ng/mL$ with $147{\pm}24\;mCi$, and 6 patients (11.5%) having above 50 ng/mL with $175{\pm}42\;mCi$. The statistical significance between sTG level and TD (p=0.252) was not shown. Conclusion: In conclusion, PS and sTG could not replace the determination of TD using I-123 scan for first HD-RAI in patients with differentiated thyroid cancer.

Ablation of Remnant Thyroid Tissue with I-131 in Well Differentiated Thyroid Cancer After Surgery (분화성 갑상선암에서 수술 후 I-131을 이용한 잔여 갑상선 조직의 제거 성적)

  • Kim, Yu-Kyeong;Lee, Dong-Soo;Cho, Bo-Yeon;Jeong, Jae-Min;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.339-345
    • /
    • 1997
  • To evaluate the effectiveness of I-131 in ablation of residual thyroid tissue, we analyzed 350 patients with thyroid cancer who were treated with various doses of I-131 after surgery for thyroid cancer Two hundred fifty five patients were treated with 1.1GBq(30mCi) of I-131 for ablation of remnant thyroid and one hundred seventeen patients received more than 2.8GBq(75mCi) of I-131. We determined the effectiveness of ablation by following I-131 whole body scan. Absent visible uptake or minimal uptake in thyroid tissue were considered as successful ablation. Of 255 patients who received doses of 30mCi I-131 therapy, 131 patients(51%) showed successful ablation of residual thyroid tissue with $2.6{\pm}1.7$ times of I-131 therapy. Of 117 patients who received doses of the more than 75mCi I-131, 84 patients(72%) had successful remnant thyroid ablation with $1.6{\pm}1.1$ times of I-131 therapy, According to the extent of surgery, successful ablation rates were 78%, 62%, 54%, 33% in patients who underwent total thyroidectomy, subtotal thyroidectomy, lobectomy and isthmectomy, lobectomy or tumorectomy, respectively. This study showed that ablation of remnant thyroid after surgery with 30mCi I-131 was successful only in 50%. Therefore, in cases of patients with high risk for recurrence, we recommend high dose I-131 for ablation of remnant after total thyroidectomy.

  • PDF

The Significance of Serum Thyroid Peroxidase as a New Tumor Marker in Papillary Thyroid Carcinoma after Thyroidectomy (유두상 갑상선암의 수술후 재발예측인자로서 혈청 Thyroid Peroxidase의 의의)

  • Chang Hang-Seok;Na Jae-Wung;Chung Woong-Youn;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.1
    • /
    • pp.46-51
    • /
    • 1999
  • Background: Total thyroidectomy and postoperative radiodiodine ablation therapy in differentiated thyroid carcinomas enhance the reliability of serum thyroglobulin(Tg) levels and radioiodine scan in detecting recurrence or distant metastasis. There have been, however, some limitations in using these methods under certain conditions. Recently, several reports have indicated that thyroid peroxidase(TPO) could be used as an alternative tumor marker. We aimed to estimate the significance of serum TPO levels in differentiated thyroid carcinoma. Materials and Methods: Forty-eight patients who had undergone total thyroidectomy due to papillary thyroid carcinomas and who had been followed-up for at least 3 years were classified into two groups: 27 patients without any evidence of recurrence in group 1; and 20 patients with recurrence or distant metastasis in group 2. All patients were examined by radioiodine scans. Serum Tg, TSH, antithyroglobulin antibody, and TPO were measured and the relationships were statistically analyzed. The sensitivity and specificity of $^{131}I$ scan, serum Tg, and serum TPO were evaluated. Results: Serum Tg levels were $3.81{\pm}5.16ng/mL$ in group 1 and $147.02{\pm}193.75ng/mL$ in group 2. Only 2 patients in group 1 showed Tg levels exceeding 10ng/mL. In contrast, 4 patients in group 2 were under 10ng/mL. Serum antithyroglobulin antibody and TSH levels showed no statistical difference between the two groups. In group 1, 16 patients showed negative serum TPO results, and 4 patients in group 2 showed negative results. There was no correlation among serum Tg levels, antithyroglobulin antibody titers, and serum TPO levels in each group. In group 2, 4 patients with negative serum Tg levels showed positive TPO results and positive whole body scans. Two cases with false negative $^{131}I$ scans showed positive serum TPO and Tg results. In 4 cases showing false negative serum TPO levels, serum Tg levels and $^{131}I$ scans were positive. Conclusion: Serum Tg levels, radioiodine scans, and serum TPO levels can be clinically used as complementary methods in the diagnosis of recurrent or metastatic thyroid carcinomas. Serum TPO levels may be helpful when other methods fail to detect recurrences or distant metastasis in highly suspected patients.

  • PDF