Compensation Algorithm for a Measurement Voltage Transformer (측정용 전압 변성기 오차 보상 알고리즘)

  • Kang, Yong-Cheol;Park, Jang-Min;Lee, Mi-Sun;Jang, Sung-Il;Kim, Yong-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.761-766
    • /
    • 2008
  • This paper describes a compensation algorithm for a measurement voltage transformer (VT) based on the hysteresis characteristics of the core. The error of the VT is caused by the voltages across the primary and secondary windings. The latter depends on the secondary current whilst the former depends on the primary current, i.e. the sum of the exciting current and the secondary current. The proposed algorithm calculates the voltages across the primary and secondary windings and add them to the measured secondary voltage for compensation. To do this, the primary and secondary currents should be estimated. The secondary current is obtained directly from the secondary voltage and used to calculate the voltage across the secondary winding. For the primary current, in this paper, the exciting current is decomposed into the two currents, i.e. the core-loss current and the magnetizing current. The core-loss current is obtained by dividing the primary induced voltage by the core-loss resistance. The magnetizing current is obtained by inserting the flux into the flux-magnetizing current curve. The calculated voltages across the primary and secondary windings are added to the measured secondary current for compensation. The proposed compensation algorithm improves the error of the VT significantly.

Development of the iron-cored electronic current transformer (철심 코어형 전자식 변류기 개발)

  • Kang, Yong-Cheol;Kim, Yeon-Hee;Jang, Sung-Il;Park, Jong-Min;Choi, Jung-Hwan;Kim, Yong-Kyun;Lee, Byung-Sung;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.136-137
    • /
    • 2008
  • A current transformer(CT) should provide the faithful reproduction of the primary current to the measurement or the protection equipments. The exciting current resulting from the hysteresis characteristics of the core causes an error between the primary current and the secondary current of the CT. A compensating algorithm for the secondary current of the current transformer that removes the effects of the hysteresis characteristics of the iron-core has proposed. The core flux linkage is calculated by integrating the measured secondary current, and then inserted into the flux-magnetizing current curve to obtain the magnetizing current. The exciting current at every sampling interval is obtained by summing the core-loss and magnetizing currents and added to the measured current to obtain the correct current. This paper describes the innovative new product of the iron-cored electronic current transformer. This product composes an iron-cored CT and an intelligent electronic device(IED) ported the compensating algorithm. The test results of the iron-cored electronic current transformers in Korea Electro-technology Research Institute(KERI) are presented.

  • PDF

Shape Memory Characteristics and Crystallization Annealing of Amorphous $Ti_{50}-Ni_{30}-Cu_{20}$ Ribbons (비정질 $Ti_{50}-Ni_{30}-Cu_{20}$ 리본의 결정화 열처리와 형상기억특성 변화)

  • Kim, Yoen-Wook;Yun, Young-Mok
    • Journal of Korea Foundry Society
    • /
    • v.28 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • Ti-Ni-Cu alloys are very attractive shape memory alloys for applications as actuators because of a large transformation elongation and a small transformation hysteresis. Rapidly solidified Ti-Ni alloy ribbons have been known to have the shape memory effect and superelasticity superior to the alloy ingots fabricated by conventional casting. In this study, solidification structures and shape memory characteristics of $Ti-Ni_{30}-Cu_{20}$ alloy ribbons prepared by melt spinning were investigated by means of DSC and XRD. Operating parameters to fabricate the amorphous ribbons were the wheel velocity of 55 m/s and the melt spinning temperature of $1500^{\circ}C$. The crystallization temperature was measured to be $440^{\circ}C$. The crystallized ribbons exhibited very fine microstructure after annealing at $440^{\circ}C$ for 10 minutes and $460^{\circ}C$ for 5 minutes and was deformed up to about 6.8% and 6.23% in ductile manner, respectively. Stress-strain curve of the ribbon exhibited a flat stress-plateau at 64 MPa and this is associated with the stress-induced a B2-B19 martensitic transformation. During cycle deformation with the applied stress of 220 MPa, transformation hysteresis and elongation associated with the B2-B19 transformation were observed to be $4.3^{\circ}C$ and 3.6%.

Experimental study on mechanical performances of lattice steel reinforced concrete inner frame with irregular section columns

  • Xue, Jianyang;Gao, Liang;Liu, Zuqiang;Zhao, Hongtie;Chen, Zongping
    • Steel and Composite Structures
    • /
    • v.16 no.3
    • /
    • pp.253-267
    • /
    • 2014
  • Based on the test on a 1/2.5-scaled model of a two-bay and three-story inner frame composed of reinforced concrete beams and lattice steel reinforced concrete (SRC) irregular section columns under low cyclic reversed loading, the failure process and the features of the frame were observed. The subsequence of plastic hinges of the structure, the load-displacement hysteresis loops and the skeleton curve, load bearing capacity, inter-story drift ratio, ductility, energy dissipation and stiffness degradation were analyzed. The results show that the lattice SRC inner frame is a typical strong column-weak beam structure. The hysteresis loops are spindle-shaped, and the stiffness degradation is insignificant. The elastic-plastic inter-story deformation capacity is high. Compared with the reinforced concrete frame with irregular section columns, the ductility and energy dissipation of the structure are better. The conclusions can be referred to for seismic design of this new kind of structure.

Analysis of Reproducing Characteristics in Perpendicular Magnetic Recording System Using Preisach Model (Preisach 모델을 이용한 수직자기기록장치의 재생특성 해석)

  • 박관수;이향범;이택동;장평우
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.1
    • /
    • pp.50-55
    • /
    • 1992
  • Numerical method for analyzing the reading process in magnetic recording system is described. Hysteresis characteristics must be included in numerical analysis not only recording process but also reading process because of hysteretic behavior of recording media. Algorithm which is consisted of finite clement method for numerical analysis and Preisach model considered to be more appropriate method than Stoner-Wohlfarth model with spin curling mode for describing hysteresis characteristics is constructed. Equations to calculate waveform of reproduced voltage is proposed. Then, this is applied to perpendicular magnetic recording systems with pole type head and double layer media. Waveform of magnetic flux density and reproduced voltage induced in head coil is obtained. If the recording current increase in recording process, magnitude of reproduced voltage in reproducing process saturates. From this saturation curve, value of current which produce maximum voltage can be obtained.

  • PDF

Correlations between Electrical Properties and Process Parameters of Silicon Nitride Films Prepared by Low Temperature (100℃) Catalytic CVD

  • Noh, Se Myoung;Hong, Wan-Shick
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.3
    • /
    • pp.209-214
    • /
    • 2015
  • Silicon nitride films were deposited at $100^{\circ}C$ by using the catalytic chemical vapor deposition technique. The source gas mixing ratio, $R_N=[NH_3]/[SiH_4]$, was varied from 10 to 30, and the hydrogen dilution ratio, $R_H=[H_2]/[SiH_4]$, was varied from 20 to 100. The breakdown field strength reached a maximum value at $R_N=20$ and $R_H=20$, whereas the resistivity decreased in the same sample. The relative permittivity had a positive correlation with the breakdown field strength. The capacitance-voltage threshold curve showed an asymmetric hysteresis loop, which became more squared as $R_H$ increased. The width of the hysteresis window showed a negative correlation with the slope of the transition region, implying that the combined effect of $R_N$ and $R_H$ overides the interface defects while creating charge storage sites in the bulk region.

The Influence of Temperature on Low Cycle Fatigue Behavior of Prior Cold Worked 316L Stainless Steel (I) - Monotonic and Cyclic Behavior - (냉간 가공된 316L 스테인리스강의 저주기 피로 거동에 미치는 온도의 영향 (I) - 인장 및 반복 거동 -)

  • Hong, Seong-Gu;Yoon, Sam-Son;Lee, Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.333-342
    • /
    • 2004
  • Tensile and low cycle fatigue (LCF) tests on prior cold worked 316L stainless steel were carried out at various temperatures from room temperature to 650$^{\circ}C$. At all test temperatures, cold worked material showed the tendency of higher strength and lower ductility compared with those of solution treated material. The embrittlement of material occurred in the temperature region from 300$^{\circ}C$ to 600$^{\circ}C$ due to dynamic strain aging. Following initial cyclic hardening for a few cycles, cycling softening was observed to dominate until failure occurred during LCF deformation, and the cyclic softening behavior strongly depended on temperature and strain amplitude. Non-Masing behavior was observed at all test temperatures and hysteresis energy curve method was employed to describe the stress-strain hysteresis loops at half$.$life. The prediction shows a good agreement with the experimental results.

Study on the Performance Improvement of an EQS Device Applied Nuclear Power Plant (원전 EQS 면진장치의 성능개선을 위한 연구)

  • Lee, You In;Lee, Yu Jin;Lee, Hong Pyo;Cho, Myung Sug;Jee, Young Su;Beak, Jun Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 2015
  • This paper presents the performance improvement of an EQS (Eradic Quake System) device applied to a nuclear power plant. For the nuclear facility, the EQS device needs to be ensured to have high quality, flexibility of design and reliability. To improve the reliability of the design, the hysteresis of the device must be exactly predicted. The friction coefficient of PTFE (PolyTetraFluoroEthylene) and the stiffness of the MER-Spring are considered as the factors influencing the hysteresis curve. In this paper, those factors are analysed to predict the behavior of the device and to improve the equipment of the EQS device. The results of the improved EQS device have been verified via a tests to be comparable with the predicted results. The estimation results indicate that considering those factors is more appropriate than the results of the previous design and method.

A Study on the Strength Properties and the Temperature Hysteresis of Winter Concrete according to the difference of Curing Method in Mock-up Test (실물대시험에서의 양생방법 차이에 따른 한중콘크리트의 온도이력 및 강도특성에 관한 연구)

  • Won, Cheol;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.87-94
    • /
    • 2003
  • This study is to investigate the temperature hysteresis and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of refusing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluating in-place concrete strength

Influence Factor on Magnetization Property of Carbonyl Iron-based Magnetorheological Fluids

  • Wang, Daoming;Zi, Bin;Qian, Sen;Qian, Jun;Zeng, Yishan
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.622-628
    • /
    • 2016
  • Magnetization property is a critical factor for magnetorheological fluids (MRFs) to achieve the liquid-solid transition. The main focus of this study is on exploring the influence factors on magnetization properties of MRFs. In this paper, a theoretical analysis is performed to discuss the magnetization characteristics of MRFs firstly. Then, a method for the preparation of carbonyl iron-based MRFs is illustrated and five MRFs samples with various material parameters are prepared. It is succeeded by a series of experiments on testing the hysteresis loop and the magnetization curve of each sample and the influence factors are compared and analyzed. Experimental results indicate that there is basically no hysteresis phenomenon on MRFs which exhibits superparamagnetic behavior at room temperature. A surfactant coating on magnetic particles can slightly improve the MRFs magnetization. Additionally, the magnetic susceptibility and the saturation magnetization both increase with the particle concentration, whereas the influence of particle diameter is relatively very small. Moreover, as the temperature increases, the magnetization decreases and the declining rate accelerates gradually.