• 제목/요약/키워드: Hyper-spectral camera

검색결과 5건 처리시간 0.023초

Radiometric Calibration Method with Compensation of Nonlinearity of Detector for Hyper-Spectral Camera

  • Yang, Ji-Hyeon;Choi, Byung-In;Park, Hee Duk;Kim, Sohyun;Park, Yong Chan
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권10호
    • /
    • pp.27-34
    • /
    • 2017
  • In this paper, we propose a novel radiometric calibration method which can effectively compensate the nonlinearity of the detector for hyper-spectral camera. In general, the detector of hyper-spectral camera can produce nonlinear output depending on radiance and integral time. The conventional radiometric calibration methods extract the imprecise radiance profile from the spectral profile of the target due to this nonlinearity. In our proposed method, we use a quadratic equation instead of a linear equation to describe the relation between output of detector and radiance. Then, we use a fractional function to compensate variation of integration time. Thus, our proposed method can extract more precise spectral profile of radiance than conventional radiometric calibration method.

FPD용 컬러 필터의 수지 얼룩 결함 형상화에 관한 연구 (A Study on the Visualization of Suzi Mora Defect of FPD Color Filter)

  • 권오민;이정섭;박덕천;주효남;김준식
    • 제어로봇시스템학회논문지
    • /
    • 제15권8호
    • /
    • pp.761-771
    • /
    • 2009
  • Detecting defects on FPD (Flat Panel Display) color filter before the full panel is made is important to reduce the manufacturing cost. Among many types of defects, the low contrast blemish such as Suzi Mura is difficult to detect using standard CCD cameras. Even skilled inspectors in the inspection line can hardly identify such defects using bare eyes. To overcome this difficulty, point spectrometer has been used to analyze the spectrum to differentiate such defects from normal color filters. However, scanning ever increasing-size color filters by a point spectrometer takes too long time to be used in real production line. We propose a system using a spectral camera which can be viewed as a line scan camera composed of an array of point spectrometers. Three types of lighting system that exhibit different illumination spectrums are devised together with a calibration method of the proposed spectral camera system. To visualize the defect areas, various processing algorithms to identify and to enhance the small differences in spectrum between defective and normal areas are developed. Experiments shows 85% successful visualization. of real samples using the proposed system.

Development of High Speed Satellite Data Acquisition System

  • Choi, Wook-Hyun;Park, Sang-Jin;Seo, In-Seok;Park, Won-Kyu
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.280-282
    • /
    • 2003
  • The downlink data rates of the space-born payloads such as high-resolution optical cameras, synthetic aperture radars (SAR) and hyper-spectral sensors are being rapidly increased. For example, the image transmission rates of KOMPSAT-2 MSC(Multi-Spectral Camera) is 320Mbps even if on-board image compression scheme is used.[1] In the near future, the data rates are expected to be a level 500${\sim}$600Mbps because the required resolution will be higher and the swath width will be increased. This paper describes many techniques they enable 500Mbps data receiving and archiving system.

  • PDF

Survey of Electro-Optical Infrared Sensor for UAV

  • Jang, Seung-Won;Kim, Joong-Wook
    • 항공우주산업기술동향
    • /
    • 제6권1호
    • /
    • pp.124-134
    • /
    • 2008
  • The rising demand for the high efficiency and high covertness in UAV motivates the miniature design of the high performing mission sensors, or payloads. One of the promising payload sensors, EO/IR sensor has evolved satisfying its demands and became the main stand-alone mission sensor for 200kg-range UAV. One aspect in development of EO/IR sensor concerns lack of specification criterions to represent its performance. Even though the high demand and competition among each manufacturer caused EO/IR features subject to rapid change collateral to new technology, the datasheets maintained the conventional outdated formats which leave some of the major components in ambiguity. Making comparisons or predicting actual performance with such datasheets is hardly worthwhile; yet, they could be important reference guide for the potential customers what to expect for the upcoming EO/IR. According to UAS Roadmap 2007-2032 published by DoD, one of the main potential customers as well as a main investor of EO/IR technology, EO/IR is expected to play key roll in solving urgent problems, such as see and avoid system. This paper will examine the recent representative EO/IR specialized in UAS missions through datasheets to find out current trend and eventually extrapolate the possible future trend.

  • PDF

드론 장착 다중분광 카메라, 소형 필드 초분광계, 휴대용 잎 반사계로부터 관측된 서로 다른 공간규모의 광화학반사지수 평가 (Assessment of Photochemical Reflectance Index Measured at Different Spatial Scales Utilizing Leaf Reflectometer, Field Hyper-Spectrometer, and Multi-spectral Camera with UAV)

  • 류재현;오도혁;장선웅;정회정;문경환;조재일
    • 대한원격탐사학회지
    • /
    • 제34권6_1호
    • /
    • pp.1055-1066
    • /
    • 2018
  • 식생의 광학적 특성을 기반으로 만들어진 식생지수들은 식물의 생물생산량뿐만 아니라 생리적 활성을 나타내고 있다. 식생지수의 활용은 위성에 장착된 다중분광 광학 센서의 발달에 힘입은 바가 크지만, 관측 공간규모에 따라 식생지수의 민감도가 달라질 수 있어 여러 규모에서의 비교 관측이 요구된다. 특히 광화학반사지수(PRI, Photochemical Reflectance Index)는 광합성능과 식물 스트레스 탐지에 유용한 것으로 알려져 있지만 올바른 해석을 위한 다양한 공간규모에서의 선행연구가 드물다. 본 연구에서는 드론에 장착된 다중분광 카메라, 소형 필드 초분광계, 휴대용 잎 반사계를 이용해 마늘 작물을 대상으로 서로 다른 공간규모의 PRI를 평가하였다. 잎 규모에서 하루 중 PRI는 잎의 윗면이 향하는 방위에 따라 서로 다른 시간에 최저값을 보였으며, 이는 어떤 순간에 잎마다 다른 광이용효율(LUE, Light Use Efficiency) 상태라는 것을 의미한다. 잎 규모에서는 식생피복율에 영향을 받지 않으므로 PRI 생물계절적 변화는 생육 초기에 개체 및 군락 규모보다 값이 높게 나타났다. 개체 및 군락 규모에서 PRI는 생물량을 나타내는 NDVI(Normalized Difference Vegetation Index)와는 달리 공간적 변동성이 크게 나타났다. 반면, 지상의 개체들 규모의 식생지수를 드론 영상의 관측 지점 값과 비교해 보면 NDVI에 비해 PRI가좀더 좋은 일치도를 보였다. 이러한 결과는 서로 다른 공간규모에서 관측된 PRI를 이해하고 활용하는데 도움이 될 것이다.