• 제목/요약/키워드: Hydrophobic/Hydrophilic

검색결과 641건 처리시간 0.029초

막증류 담수화를 위한 친수성/소수성 이중 표면 코팅 (Hydrophilic/Hydrophobic Dual Surface Coatings for Membrane Distillation Desalination)

  • 김혜원;이승헌;정성필;변지혜
    • 한국물환경학회지
    • /
    • 제38권3호
    • /
    • pp.143-149
    • /
    • 2022
  • Membrane distillation (MD) has emerged as a sustainable desalination technology to solve the water and energy problems faced by the modern society. In particular, the surface wetting properties of the membrane have been recognized as a key parameter to determine the performance of the MD system. In this study, a novel surface modification technique was developed to induce a Janus-type hydrophilic/hydrophobic layer on the membrane surface. The hydrophilic layer was created on a porous PVDF membrane by vapor phase polymerization of the pyrrole monomer, forming a thin coating of polypyrrole on the membrane walls. A rigid polymeric coating layer was created without compromising the membrane porosity. The hydrophilic coating was then followed by the in-situ growth of siloxane nanoparticles, where the condensation of organosilane provided quick loading of hydrophobic layers on the membrane surface. The composite layers of dual coatings allowed systematic control of the surface wettability of porous membranes. By the virtue of the photothermal property of the hydrophilic polypyrrole layer, the desalination performance of the coated membrane was tested in a solar MD system. The wetting properties of the dual-layer were further evaluated in a direct-contact MD module, exploring the potential of the Janus membrane structure for effective and low-energy desalination.

친수성/소수성 수평 표면상에서의 액적이송 메커니즘 (Droplet Transport Mechanism on Horizontal Hydrophilic/Hydrophobic Surfaces)

  • 명현국
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.513-523
    • /
    • 2014
  • 유체이송 기술은 최근 마이크로 유체시스템 개발에서 핵심문제로 인식되고 있다. 본 연구에서는 최근 저자가 제안한 외부동력을 사용하지 않고 액적을 이송시킬 수 있는 새로운 개념인 친수성/소수성 수평 표면에서의 액적이송을 자체개발 코드(PowerCFD)를 사용하여 수치해석하였다. 수치해석에 사용된 코드는 보존적인 압력기반 유한체적방법에 기초한 비정렬 셀 중심 방법 및 VOF 방법에 체적포착법인 CICSAM을 채용하고 있다. 액적 내 및 주위의 속도벡터, 압력분포 및 전체운동에너지와 같은 수치해석 결과를 제시하고 이 결과들을 통해 액적이송 메커니즘을 규명하였다.

응집제 주입에 따른 NOM과 저압막의 막오염 특성에 관한 연구 (A study on the fouling characteristics of low-pressure membranes and NOM with coagulation pretreatment)

  • 박상혁;홍종현;유명진;구자용
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.237-246
    • /
    • 2010
  • This study was carried out to compare the performances of hydrophobic and hydrophilic membranes in the filtration of the pretreatment waters using coagulants such as PAC and PAHCs, and to investigate the influence of NOM characteristics on the fouling of membranes. As a result, the hydrophobic fraction was more effectively removed by PAHCs, however the transphilic and hydrophilic fraction were more effectively removed by PAC on NOM removal. Raw water showed the highest response in the range of humic substances, and pre-coagulated waters with PAC and PAHCs followed. It was also observed that the fouling effect for a hydrophobic membrane was greater than that of a hydrophilic membrane with a similar pore size, due to fouling caused by adsorption. Foulants causing significant flux decline were alcoholic compounds (polysaccharide-like) and humic substances including aromatic groups. Especially, it appeared that alcoholic compounds such as polysaccharide-like substances which mostly remained after coagulation pretreatment had most influence on fouling. It was found that fouling were influenced by each fraction NOM components depending on coagulants used. And PAHCs was more efficient for membrane fouling than PAC.

Synthesis and Characterization of Sulfonated Poly(arylene ether) Polyimide Multiblock Copolymers for Proton Exchange Membranes

  • Lee, Hae-Seung;Roy Abhishek;Badami Anand S.;McGrath James E.
    • Macromolecular Research
    • /
    • 제15권2호
    • /
    • pp.160-166
    • /
    • 2007
  • Novel multiblock copolymers, based on segmented sulfonated hydrophilic-hydrophobic blocks, were synthesized and investigated for their application as proton exchange membranes. A series of segmented sulfonated poly(arylene ether sulfone)-b-polyimide multiblock copolymers, with various block lengths, were synthesized via the coupling reaction between the terminal amine moieties on the hydrophilic blocks and naphthalene anhydride functionalized hydrophobic blocks. Successful imidization reactions required a mixed solvent system, comprised of NMP and m-cresol, in the presence of catalysts. Proton conductivity measurements revealed that the proton conductivity improved with increasing hydrophilic and hydrophobic block lengths. The morphological structure of the multiblock copolymers was investigated using tapping mode atomic force microscopy (TM-AFM). The AFM images of the copolymers demonstrated well-defined nanophase separated morphologies, with the changes in the block length having a pronounced effect on the phase separated morphologies of the system. The self diffusion coefficient of water, as measured by $^1H$ NMR, provided a better understanding of the transport process. Thus, the block copolymers showed higher values than Nafion, and comparable proton conductivities in liquid water, as well as under partially hydrated conditions at $80^{\circ}C$. The new materials are strong candidates for use in PEM systems.

친수성/소수성 수평 표면상에서의 액적이송에 관한 새로운 개념 (A New Concept to Transport a Droplet on Horizontal Hydrophilic/Hydrophobic Surfaces)

  • 명현국
    • 대한기계학회논문집B
    • /
    • 제38권3호
    • /
    • pp.263-270
    • /
    • 2014
  • 유체이송 기술은 최근 마이크로 유체시스템 개발에서 핵심문제로 인식되고 있다. 본 논문에서는 외부동력을 사용하지 않고 액적을 이송시킬 수 있는 새로운 개념을 제안하고, 수치해석을 통해 증명하였다. 제안된 장치는 표면을 단순하게 친수성과 소수성 표면의 복합표면으로 구성하는 것이다. 새로운 개념을 입증하기 위한 수치해석은 보존적인 압력기반 유한체적방법에 기초한 비정렬 셀 중심 방법 및 VOF 방법에 체적포착법인 CICSAM을 채용하고 있는 자체개발 코드(PowerCFD)를 사용하였다. 연구결과 본 연구에서 제안된 개념이 마이크로 유체시스템에서 액적이송에 대해 우수한 성능을 나타내는 것으로 확인되었다.

Graft copolymerization of GMA and EDMA on PVDF to hydrophilic surface modification by electron beam irradiation

  • Lim, Seung Joo;Shin, In Hwan
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.373-380
    • /
    • 2020
  • This study was carried out to convert the hydrophobic characteristics of PVDF to hydrophilic. Poly(-vinylidene fluorine) (PVDF) was grafted by electron beam irradiation and sulfonated. The grafting degree of modified PVDF increased with the monomer concentration, but not the conversion degree. From the results of FTIR and XPS, it was shown that the amount of converted sulfur increased with the grafting degree. The radiation-induced graft polymerization led to decrease fluorine from 35.7% to 21.3%. Meanwhile, the oxygen and sulfur content increased up to 8.1% and 3.2%. The pore size of modified membranes was shrunken and the roughness sharply decreased after irradiation. The ion exchange capacity and contact angle were investigated to show the characteristics of PVDF. The enhanced ion exchange capacity and lower contact angle of modified PVDF showed that the hydrophilicity played a role in determining membrane fouling. Electron beam irradiation successfully modified the hydrophobic characteristics of PVDF to hydrophilic.

RESEARCH PAPERS : CHARACTERIZATION OF DISSOLVED ORGANIC MATTER IN A SHALLOW EUTROPHIC LAKE AND INFLOWING WATERS

  • 김용환;이선화
    • Environmental Engineering Research
    • /
    • 제7권2호
    • /
    • pp.93-101
    • /
    • 2002
  • The seasonal patterns of dissolved organic matter (DOM) in Lake Kasumigaura, a shallow, eutrophic lake, and serveral DOM sources in its catchment area were investigated. DOM was fractionated using three resin adsorbents into classes: aquatic humic substances (AHS=humic acid+fulvic acid), hydrophobic neutrals (HoN), hydrophilic acids (HiA), bases (BaS) and hydrophilic neutrals (HiN). The DOM produced significantly different fraction distributions depending on the origin of sample. AHS and HiA prevailed over AHS in the lake while AHS and HiA existed at almost the same concentration levels in the rivers. AHS seems to be a more dominant component in rever water than lake water. The dominance of organic acids was also observed in the DOM sources: forest stream (FS), plowed field percolate (PFP), domestic sewage (DS) and sewage treatment plant effluent (STPE).

Methyl- $\beta$ -D-Fructofuranoside 합성을 위한 고정화 전화당 효소의 미소환경 최적화 (Microenvironmental Optimizaton of Immobilized Invertase for Methyl- $\beta$ -D-Fructofuranoside Synthesis)

  • 허주형;안형환
    • 대한안전경영과학회지
    • /
    • 제1권1호
    • /
    • pp.259-272
    • /
    • 1999
  • In order to enhance the selectivity, productivity and yield of methyl fructoside, which was synthesized by enzymatic glycosylation of sucrose and methanol solution, controlling of surface property of solid support using different immobilization procedures optimized microenvironment of immobilized invertase. Silanization and polyethylene imine coating methods were adopted to give a hydrophobic and hydrophilic environment of immobilized invertase. As a result, polyethyleneimine coating method gave higher loading of enzyme, effective activity, and relative activity than silanization method, because it brought on increasing the functional density of amino group and enhancing the conservation of activity by regulating of hydrophilicity. And then, hydrophilic environment was possible to restraint the assessing of methyl fructoside molecule, which was more hydrophobic than sucrose, fructose, and glucose molecule in the reaction mixture, into .the active site of immobilizedinvertase. Consequently, hydrophilic microenvironment of immobilized invertase by polyethyleneimine coating obtained higher yield and productivity with increasing conversion than silanized and native invertase. Thus, this procedure optimized the microenvironment of immobilized invertase suitable for the enzymatic synthesis of methyl fructoside.

  • PDF

환경 및 섬유 특성이 멀티레이어 직물시스템의 투습성에 미치는 영향 (Effects of Relative Humidity and Fiber Properties on the Moisture Permeability of Multilayer Fabric Systems)

  • 이수현;박소현
    • 한국의류산업학회지
    • /
    • 제25권1호
    • /
    • pp.119-126
    • /
    • 2023
  • This study aimed to determine the effects of relative humidity and fiber properties on the moisture permeability of multilayer systems by measuring water vapor transmission in the overlapping condition of various fabrics. The results confirmed that the property of the fabric in contact with the humid environment affects the moisture permeability. If the layer facing the humid environment is hydrophobic and the layer facing the dry environment is superhydrophobic, water vapor transmission increases by up to 17.8% compared to the opposite conditions. Comparing the correction values of the water vapor transmission reflecting the thickness of the specimen under the multilayer condition showed that permeability was higher when the hydrophilic or hydrophobic layer was facing the humid environment. The opposite was true from the "push-pull" effect of absorption mechanism. In the case of moisture permeability, the more hydrophilic the surface facing the humid environment, the more permeable that water vapor diffuses and passes through. It was concluded that the "pull-push" effect, in which water vapor diffuses widely through the hydrophilic facing a humid environment and then passes through the hydrophobic layer, contributes to the improvement of permeability. Permeability differed according to the multilayer overlapping condition. When the relative humidity was high, the "pull-push" effect was insignificant. This is caused by water droplets absorption after the partial migration of water due to condensation. These results suggest that the overlapping conditions and properties of fabrics should vary depending on heavy sweating or not.

막오염에 미치는 유기물 분자량 분포특성 및 화학적 구조특성 (Effect of Organic Melecular Weight and Functional Group on Membrane Fouling)

  • 정철우;손희종;신현준;손인식
    • Korean Chemical Engineering Research
    • /
    • 제45권6호
    • /
    • pp.669-676
    • /
    • 2007
  • 낙동강 매리지역 원수에 대해 유기물 성상분석을 한 결과, 소수성 물질이 43%, 친수성 물질이 39%, 반친수성 물질이 18%를 차지하고 있는 것으로 나타났으며, 각각의 유기물질에 대한 분자량 크기 분포 특성을 살펴보면 소수성 > 반친수성 > 친수성 물질의 순으로 분자량 분포특성을 보였다. 막 공극 크기에 따른 영향을 살펴본 결과 막 공극 크기가 증가할수록 공극 내에서 공극 막힘현상과 공극 흡착현상이 막오염의 주된 메카니즘으로 작용하여 투과 flux 감소율이 크게 나타나는 것으로 조사되었다. 막의 재질에 따른 영향을 살펴본 결과 소수성 막의 경우 친수성 막에 비하여 소수성 상호반응(hydrophobic interaction)에 의하여 유기물에 의한 막 오염 현상이 발생하여 투과 flux 감소율이 더 크게 나타나고 초기 투과 flux 감소율도 빠르게 진행되었다. 원수에 대한 막의 재질과 막의 공극크기에 따른 막오염 메카니즘 분석결과 소수성 재질의 막에서 막표면 오염을 나타내는 Kc, 막의 공극흡착현상을 나타내는 Ks, 막의 공극 막힘현상을 나타내는 Ki 값이 상대적으로 크게 나타났다. 막의 공극 크기에 따른 막 오염 메카니즘 분석결과 막의 100 kDa 이상의 공극이 큰막의 경우에는 소수성 계열의 유기물이 막의 공극 내부에서 막 오염을 유발하였으며, 10 kDa 정도로 공극이 작은 막의 경우 소수성과 친수성 계열 유기물이 막 표면에서 막 오염을 유발하는 메카니즘이 주원인으로 작용하였다