• Title/Summary/Keyword: Hydrogen Removal Rate

Search Result 145, Processing Time 0.023 seconds

Development of Porous Sorbents for Removal of Hydrogen Sulfide from Hot Coal Gases III. Study on Ferrite-type adsorbent for the Removal of Hydrogen Sulfide

  • Kim, Jong-Saeng;Lee, Young-Soo;Lee, Bok-Jae;Yoo, Kyong-Ok
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.39-49
    • /
    • 1991
  • 고온에서 황화수소(H$_{2}$S)를 제거하기 위한 흡착제를 개발할 목적으로 ZnO에 $Fe_{2}O_{3}$를 5~50 atomic %까지 첨가시켜 제조한 다공성 흡착제와 황화수소와의 반응(sulfidation)을 thermogravimetric analyzer (Shimadzu DT-30)로 수행하였으며, 고정층세서 zinc ferrite 흡착제의 흡착능을 측정하였다. 반응온도는723$^{\circ}$K~973$^{\circ}$K범위이며, 반응기체는 황화수소(2vol.%)와 질소와 혼합기체로서 total gas flow rate는 200ml/min으로 고정시켰다. Grain Model을 사용하여 실험데이터를 분석한 결과 전화율이 낮을 때 zinc ferrite와 황화수소 반응의 율속단계는 화학반응이었고 황화수소 농도에 대해 1차 반응이었다. 실험한 흡착제 중 10 atomic %의 $Fe_{2}O_{3}$를 첨가하여 제조한 zinc ferrite형 흡착제가 반응속도, 흡착능, 그리고 재생성면에서 우수한 흡착제로 밝혀졌다.

  • PDF

Characteristics of Hydrogen-sulfide(H2S) removal by a Biofilter with Organic Materials, Peat and Rock wool (유기담체인 Peat 및 Rock wool을 사용한 바이오필터에 의한 황화수소(H2S)의 제거특성)

  • Kim, Nam-jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.3
    • /
    • pp.136-144
    • /
    • 2001
  • Two organic materials, peat and rock wool were used for removal of $H_2S$ by a biofilter inoculated with night soil sludge. By gradually increasing the inlet load of $H_2S$, the complete removal capacity, which was defined as the inlet load of $H_2S$ that was complete removed, and the maximum removal capacity of $H_2S$, which was the value when the removal capacity leveled off for organic materials, were estimated. Both values for Rock wool are larger than peat, based on a unit dry weight of material. By using kinetic analysis, the maximum removal rate of $H_2S$, $V_m$, and the saturation constant, $K_s$, were determined for all packing materials and the values of $V_m$ for rock wool was found to be larger. By using the kinetic parameters, the removal rates for $H_2S$ were compared both packing materials, and rock wool showed better performance for the removal of $H_2S$ in the inlet concentration range of 0~200ppm.

  • PDF

Effects of Mixed Oxidizer on the W-CMP Characteristics (혼합 산화제가 W-CMP 특성에 미치는 영향)

  • 박창준;서용진;김상용;이우선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1181-1186
    • /
    • 2003
  • Chemical Mechanical Polishing (CMP) is an essential dielectric planarization in multilayer microelectronic device fabrication. In the CMP process, it is necessary to minimize the extent of surface defect formation while maintaining good planarity and optimal material removal rates. The polishing mechanism of W-CMP process has been reported as the repeated process of passive layer formation by oxidizer and abrasion action by slurry abrasives. Thus, it is important to understand the effect of oxidizer on W passivation layer, in order to obtain higher removal rate (RR) and very low non-uniformity (NU %) during W-CMP process. In this paper, we compared the effects of oxidizer or W-CMP process with three different kind of oxidizers with 5 wt% hydrogen peroxide such as Fe(NO$_3$)$_3$, H$_2$O$_2$, and KIO$_3$. The difference in removal rate and roughness of W in stable and unstable slurries are believed to caused by modification in the mechanical behavior of Al$_2$O$_3$ particles in presence of surfactant stabilizing the slurry.

Development of a Gliding Arc Plasma Reforming System to Produce Hydrogen Form Biogas (바이오가스 개질을 위한 글라이딩 아크 플라즈마 개질 시스템 개발)

  • Kim, Seong Cheon;Yang, Yoon Cheol;Chun, Young Nam
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.423-429
    • /
    • 2009
  • The purpose of this study is to investigate the optimal condition for the hydrogen-rich gas production and the CO removal by reforming of gliding arc plasma reforming system using biogas. The parametric screening studies were carried out according to changes of steam feed amount, catalyst bed temperature in water gas reactor and catalyst bed temperature, input air flow rate in preferential oxidation reactor. The standard condition is as follows. The steam/carbon ratio, catalyst bed temperature, total gas flow rate, input electric power and biogas composition rate ($CH_4$ : $CO_2$) were fixed 3, $700^{\circ}C$, 16 L/min, 2.4 kW and 6 : 4, respectively. The results are as follow, HTS optimum operating conditions were S/C ratio of 3 and reactor temperature of $500^{\circ}C$. LTS were S/C ratio of 2.9 and temperature of $300^{\circ}C$. Also, PROX I optimum conditions were input air flow rate of 300 mL/min and reactor temperature of $190^{\circ}C$. PROX II were 200 mL/min and $190^{\circ}C$ respectively. After having passed through each reactor, the results were as follows: 55% of $H_{2}$ yield, 0% of CO selectivity, 99% of $CH_4$ conversion rate, 27% of $CO_2$ conversion rate, respectively.

A Study on the Removal of Hydrogen Sulfide by the Manganese Based Sorbents (망만계 탈황제에 의한 황화수소 제거에 관한 연구)

  • 손병현;최성원;김영식;정종현;조상원;오광중
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 1996
  • Experiments have been made to test the practical feasibility of using calcined manganese ore to desulfurize hot reducing gas. In this study, the effects of particle size of sorbents, temperature of sulfidation, flow rate and sorbent characteristics on the $H_2S$ removal efficiency of calcined manganese ore were investigated. Experimental results showed that the removal efficiency of $H_2S$ was optimum when the temperature was about 800$\circ$C and that the smaller particle size the higher the $H_2S$ removal efficiency. When the temperature was above 800$\circ$C, the reactivity of sorbent has lowered because agglomeration of sorbent increased intraparticle transport resistance, and this phenomenon was confirmed by SEM photographs. As the temperature increases, capacity for the $H_2S$ removal was increased but the equilibrium concentration of $H_2S$ was not affective.

  • PDF

Reuse of Hydrogen Sulfide by Ferric Chelate Reaction of Food Waste Anaerobic Digestion Gas, Sulfur Recovery and its Economic Evaluation (킬레이트 착화학반응에 의한 음식물폐기물 혐기소화가스 중 황화수소의 제거와 황회수 및 경제성평가)

  • Park, Young G.;Yang, Youngsun
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.367-374
    • /
    • 2014
  • Several experiments have been done to investigate the removal of hydrogen sulfide ($H_2S$) synthetic gas from biogas streams by means of chemical absorption and chemical reaction with 0.1-1 M Fe/EDTA solution. The roles of Fe/EDTA were studied to enhance the removal efficiency of hydrogen sulfide because of oxidizing by chelate. The motivation of this investigation is first to explore the feasibility of enhancing the toxic gas treatment in the biogas facility. The biogas purification strategy affords many advantages. For instance, the process can be performed under mild environmental conditions and at low temperature, and it removes hydrogen sulfide selectively. The end product of separation is elemental sulfur, which is a stable material that can be easily disposed with minor potential for further pollution. As the Fe-EDTA concentration increased, the conversion rate of hydrogen sulfide increased because of the high stability of Fe-EDTA complex. pH as an important environmental factor was 9.0 for the stability of chemical complex in the oxidation of hydrogen sulfide.

A Study on Biofilter for Hydrogen Sulfide Removal (황화수소 제거를 위한 Biofilter에 관한 연구)

  • Bin, Jeong-In;Lee, Byeong-Heon;Kim, Jung-Gyun;Gwon, Seong-Hyeon;Kim, Sang-Gyu;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.10 no.4
    • /
    • pp.287-292
    • /
    • 2001
  • A packed bed of volcanic rock was used as deodorizing material to remove hydrogen sulfide($H_2$S) from air in a laboratory-scale column, and was inoculated with Thiobacillus sp. as $H_2S$ oxidizer. The effects of volcanic rock particle size distribution on system pressure drop were examined. Various tests have been conducted to evaluate the effect of $H_2S$ inlet concentration and CBCT(Empty Bed Contact Time) on $H_2S$ elimination. The pressure drop for particles of size range from 5.6 to 10 mm was 14 mm$H_2S$/m at a representative gas velocity of 0.25m/s. Biofilter using scoria and Thiobacillus sp. could get the stable removal efficiencies more than 99.9% under $H_2S$ inlet concentrations in the range from 30 to 1,100ppm at a constant gas flow rate of $15.2{\ell}$/min. $H_2S$ removal efficiencies greater than 99% were observed as long as EBCT was longer than 8sec at the 250ppm of $H_2S$ inlet concentration. When EBCT was reduced to 5.5 sec, $H_2S$ removal efficiency decreased by about 12 percent. The maximum $H_2S$ elimination capacity was determined to be 269g-$H_2S/m^3{\cdot}hr$.

  • PDF

Effect of Sulfide Removal on Sulfate Reduction at pH 5 in a Hydrogen Fed Gas-Lift Bioreactor

  • Bijmans, Martijn F.M.;Dopson, Mark;Ennin, Frederick;Lens, Piet N.L.;Buisman, Cees J.N.
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.11
    • /
    • pp.1809-1818
    • /
    • 2008
  • Biotechnological treatment of sulfate- and metal-ions-containing acidic wastewaters from mining and metallurgical activities utilizes sulfate-reducing bacteria to produce sulfide that can subsequently precipitate metal ions. Reducing sulfate at a low pH has several advantages above neutrophilic sulfate reduction. This study describes the effect of sulfide removal on the reactor performance and microbial community in a high-rate sulfidogenic gas-lift bioreactor fed with hydrogen at a controlled internal pH of 5. Under sulfide removal conditions, 99% of the sulfate was converted at a hydraulic retention time of 24 h, reaching a volumetric activity as high as 51 mmol sulfate/l/d. Under nonsulfide removal conditions, <25% of the sulfate was converted at a hydraulic retention time of 24 h reaching volumetric activities of <13 mmol sulfate/l/d. The absence of sulfide removal at a hydraulic retention time of 24 h resulted in an average $H_2S$ concentration of 18.2 mM (584 mg S/I). The incomplete sulfate removal was probably due to sulfide inhibition. Molecular phylogenetic analysis identified 11 separate 16S rRNA bands under sulfide stripping conditions, whereas under nonsulfide removal conditions only 4 separate 16S rRNA bands were found. This shows that a less diverse population was found in the presence of a high sulfide concentration.

The Treatment of Flue SO$_2$ Gas by Cu Powder (I) (구리 분말을 이용한 $SO_2$ 배기가스의 처리(I))

  • 정국삼;김학성;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.1 no.1
    • /
    • pp.27-32
    • /
    • 1986
  • To remove sulfur dioxide from flue gas by the method of metal oxide, copper powder of average diameter $2.4\mu\textrm{m}$and $51\mu\textrm{m}$ were used in a fixed bed reactor over a, temperature range of $300^{\circ}C-500^{\circ}C$. Copper oxide reacts with sulfur dioxide producing cupric sulfate and it can be regenerated from the latter by using hydrogen or methane. Experimental results showed that the reaction rate was increased by the increase of reaction temperature in the range of $300^{\circ}C-422^{\circ}C$ and the removal efficiency of sulfur dioxide was high in case of small size copper particle. However the removal efficiency was decreased at higher temperature due to decomposition of cupric sulfate. The rate controlling step of this reaction was chemical reaction and deactivating catalysts model can be applied to this reaction. The rate constants for this reaction and deactivation are as follows : k=8,367exp(-10,298/RT) Kd=2.23exp(-8,485/RT)

  • PDF

Studies on the Adsorbents for Cigarette Filter I. Effect of Pore Voume Distribution and Specific Area of Adsorbents on the Removal Efficiency of Smoke Components by Triple Filter (담배필터용 흡착제에 관한 연구 제1보. 흡착제의 종류와 동공특성이 담배연기성분 제거능에 미치는 영향)

  • 박태무;이영택;김성한;오영일
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.10 no.1
    • /
    • pp.75-82
    • /
    • 1988
  • Cigarettes were made using a triple filter with several porous materials in its cavity. The removal effect of the adsorbents on carbon monoxide and hydrogen cyanide in cigarette smoke was investigated with the variation of their surface area and pore volume distributions. Several attempts were made to activated coconut shell based char under the fixed steam purging rate. 1. The specific surface area increased in number of micropore. It was found for transitional pore to have a little effect on the total surface area. 2. A Small amount of the particulate matter adsorbed on the adsorbents with transitional pores, Zeolite showed a little effect on the carbon monoxide adsorption though its small pore volume, but there was no significant difference in the adsorption capacity zeolite and the others. 3. In the adsorption for hydrogen cyanide as a vapor phase in cigarette smoke, the adsorption effect of the adsorbents increased remarkably with increasing their surface area and number of micropore. It was considered that the adsorbents with small pore volume like molecular seive 4A, in which the capillary diffusion of adsorbates could not be able, would not be effective for the adsorption of hydrogen cyanide.

  • PDF