• 제목/요약/키워드: Hydraulic equipment

검색결과 585건 처리시간 0.029초

환형소결체 하나로 조사시험용 무계장 리그의 차압 및 유동유발 진동시험 (Pressure Drop and Flow-Induced Vibration Test for the HANARO Non-instrumented Irradiation Test Rig of Annular Fuel Pellet)

  • 이강희;김대호;방제건
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.281-286
    • /
    • 2007
  • Needs of fuel's performance evaluation for the dual-cooled fuel pellet (annular shape) necessitate the irradiation test in the test reactor. Irradiation test rig for the HARARO reactor, which is a special-purposed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this paper, pressure drop and flow-induced vibration test for the newly developed non-instrumented test rig were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin. The spectral response characteristics of the flow-induced vibration of the test rid were also discussed.

  • PDF

환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험 (Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor)

  • 이강희;김대호;전태현;김형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.226-229
    • /
    • 2008
  • To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

  • PDF

모의실험장치에서의 기계적인 동요에 대한 단순모사 장치개발 (Development of Simple Simulation by Changing the Stroke of Cylinder for a Oscillation)

  • 설상석;정원지;정동원
    • 한국정밀공학회지
    • /
    • 제33권2호
    • /
    • pp.89-94
    • /
    • 2016
  • Equipments to influence by external force have to take effect mechanical oscillation. These equipments regardless of the movement on the external force such as roll, pitch and heave etc, worked to keep the height of tote are required for activeness and needed a device as equipment's fluctuation for rapidly compensation. Because the actual development of these devices is difficult to cost-effectively, we were developed to compensation simulator scaled down 1/50. In this paper, we were studying kinematic characteristics, designed the simulator to grasp the point and manufactured. This paper was analyzed for confirming the superiority of compensation simulator and set up 50 ton crane in practice.

154kV 주변압기용 가스차단기(GCB) 소손에 따른 원인규명과 항구대책 분석 (A Study on the cause and permanent measures on trouble of the GCB for the Main Tr. of Voltage, 154kV)

  • 전규남;장문성;옥광석;남궁혁;안주훈;정재원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.285-286
    • /
    • 2008
  • The Gas Circuit Breaker for the Main Transformer of voltage, 154kV at the ist Hapcheon hydraulic power station, break down by the falling of a thunderbolt from now, let's improve the efficiency on the maintenance of generating equipment by studying about the cause and the method for this problem.

  • PDF

정수장내 수류에너지를 이용한 액체약품의 효율적인 혼화를 위한 수리해석 (Numerical Study on effective Mixing Chemical Liquid using Hydraulic Energy in a Water Treatment Plant)

  • 송길섭;오석영;박영빈
    • 한국전산유체공학회지
    • /
    • 제7권2호
    • /
    • pp.1-7
    • /
    • 2002
  • The present study is developed device that effectively mixes raw water and chemicals by using the residual head of fluid in the front pipe of flocculation basin, and performed non-dimensional analysis and presented design standard to apply to water plants that have different equipment capacity. The variables for design are a proper ratio between an outer diameter of deflector and a diameter of pipe, a distance between deflector and orifice and a determination of orifice diameter for an optimal mixing. Numerical study has analyzed flow field on a basis of turbulent intensity in an orifice downstream. As Reynolds number of In-Line Orifice was increased from identical design variable, the turbulent intensity of pipe center was no changed almost.

합천수력 154kV 옥외변전소 낙뢰대책 및 접지보강 연구 (A Study on the Lightning Protection and Earthing Supplement for 154kV Switch yard of Hapchon Hydro-Power Station)

  • 남궁혁;전규남;옥광석;최형철;이남형;장정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.83_84
    • /
    • 2009
  • The Gas Circuit Breaker for the Main Transformer in switch yard at the 1st Hapcheon hydraulic power station, has broken down by direct lightning stroke and induced stroke. so, this paper present the stable operation of equipment in switch yard through the improvement of earthing system and the protection to the lightning

  • PDF

Effect of Blade Angle on the Performance of a Cross-Flow Hydro Turbine

  • Choi, Young-Do;Lim, Jae-Ik;Kim, You-Taek;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.413-420
    • /
    • 2008
  • In order to improve the performance of cross-flow hydro turbine, detailed examination of the effect of the turbine configuration on the performance is needed necessarily. Therefore, this study is aimed to investigate the effect of blade angle on the performance of the cross-flow hydro turbine. Analysis of the turbine performance with the variation of the blade angle has been made by using a commercial CFD code. The results show that inlet and outlet angles of runner blade give considerable effect on the performance of the turbine. Pressure on the surface of the runner blade changes remarkably by the blade angle both at the Stages 1 and 2. Moreover, relatively small blade inlet angle is effective to produce higher value of output power. Recirculating flow in the runner passage causes remarkable hydraulic loss.

내부세레이션홈이 존재하는 외치차 단조에 관한 연구 (A Study on the Forging of Gears with lnternal Serrations)

  • 최종용;조해용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.633-637
    • /
    • 1995
  • Numerical calculation tool for forging of gear-like components based on kinematically admissible velocity fields for upper bound method applicable to various deformation features of workpiece in forging processes were suggested. Each one of them deals with unidirectional flow of metal on dies, such as external involute spur gear, sequare spline, internal serrations. A complex calcuation tool of gear-like component forging process was built up by combining these kinematically velocity fields. In this paper, the workpiece with both external and internal teeth is divided into two parts. The deformation of each part is analyzed simultaneously using numerical calculation tool form combined kinematically admissible velocity field. The experimental set-up was installed in a 200 ton hydraulic press. As a result, each kinematically admissible velocity field could be combined with other and the calculated solution are useful to predict the capacity of forging equipment.

  • PDF

3축 로드 시뮬레이터의 구조 및 동적 해석 (Structural and Dynamic Analysis of Three-Axis Road Simulator)

  • 황성호;김화진;박창수;최경락
    • 한국자동차공학회논문집
    • /
    • 제11권5호
    • /
    • pp.105-111
    • /
    • 2003
  • The three-axis road simulator is the test equipment which can simulate the standardized road conditions for the durability evaluation of automotive components such as suspensions. The road load data are collected and acquired from a vehicle test, and then these data are used to simulate road load conditions by the road simulator which consists of hydraulic actuators, link mechanism and servo controller. The link mechanism must be designed in consideration of the dynamic effect and interference during three axes motions in order to generate accurate motions. In this paper, the structural and kinematic analysis of the link mechanism is performed, and these results can be used for developing the three-axis road simulator. The three-axis road simulator provides considerable savings in cost, development time, and testing risk during developing automotive components.

수력발전기 자동동기투입 실패에 관한 고찰 (A Study on Auto synchronization failure of a Generator)

  • 전규남;장문성;이재훈;정재원;안주훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.268-269
    • /
    • 2006
  • Auto-synchonizer is important device to match the voltage, frequency, phase of the generating system to those factors of the transmission line, when the synchronous generator is operated. There were few or no incidents by Synchronization failure at Hapcheon hydraulic power plant, since it was built in 1989. but incidents by Synchronization failure have often happend lately. From now, let's improve the efficiency on the maintenance of generating equipment by studying about the cause and the method for this problem by comparing with the set point of each device of synchronizing system.

  • PDF